JKJohn P. Kizito

John P. Kizito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


John P. Kizito has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical Investigation of Heat Transfer Augmentation in Axial and Parallel Rotating Channels with Inserts

    by Kofi Yeboah Asante, Abraham Adu-Mills, Yashitha Thuraka, Obed Y. W. Abotsi, Richard Opoku, John P. Kizito

    Rotating cooling channels are an effective way to enhance convective heat transfer in high-speed, high-power-density electric machines. This study numerically investigates the flow and heat transfer in axial and parallel rotating channels across a range of axial Reynolds numbers (Rea = 5000–25,000) and rotation numbers (N = 1–3). The numerical study is conducted using three-dimensional RANS simulations with the realizable k-ϵ model, validated against established rotating pipe correlations. Parallel rotation consistently produces higher heat transfer enhancement than axial rotation under identical operating conditions, with the Nusselt number (Nu) increasing with the eccentricity ratio (H/D). The largest enhancement is observed for the parallel configuration at H/D = 8, where Nu increases by 88% compared to the axial case at Rea = 5000 and N = 3, resulting from amplified centrifugal forces that generate intense secondary vortices. The effect of a Kenics static mixer is also evaluated in both configurations. The insert enhances Nu by 17–38% in axial channels, where rotational effects alone are insufficient to promote strong secondary flow, but produces only marginal gains of 0–8% in parallel channels at H/D = 8, despite a significant increase in pressure drop. Thermal Performance Factor (TPF) analysis against the stationary pipe benchmark reveals that all empty pipe rotating configurations achieve TPF > 1, reaching a maximum of 1.47 for the parallel H/D = 8 configuration at Rea = 5000 and N = 3, while all Kenics-equipped configurations produce TPF < 1 throughout the study. The scientific contribution of this study is twofold. First, the Kenics mixer provides substantial heat-transfer enhancement that is strongest in axial channels and diminishes with increasing eccentricity (0–8% at H/D = 8). Second, despite this heat-transfer enhancement, the Kenics-equipped configurations yield TPF < 1 in every case examined, meaning Nu gains do not offset the associated pressure penalty on a performance-weighted basis. By contrast, the empty rotating configurations—particularly parallel rotation at high eccentricity—achieve TPF > 1 up to 1.47 (H/D = 8, Rea = 5000, N = 3). These results indicate that rotation alone is the preferred augmentation strategy when overall thermo-hydraulic performance is the design objective, while Kenics inserts should be reserved for applications where maximum heat-transfer enhancement is prioritized over the pressure penalty.

  • Open Access

    Numerical Investigation of Heat Transfer Enhancement Using Novel “Ram-Horn” Internal Fins in a Tube

    by Abraham Adu-Mills, Kofi Yeboah Asante, Yashitha Thuraka, John P. Kizito

    Most passive heat exchanger tube inserts only raise the Nusselt number by dramatically increasing friction, and studies on fin inserts have generally focused on low turbulent Reynolds numbers used in plant equipment. In this study, we numerically investigate a ram-horn internal fin whose branch radii follow a Fibonacci spiral, implemented in a 25 mm inner-diameter copper tube and solved using computational fluid dynamics software (ANSYS FLUENT 2026) with conjugate heat transfer for Re = 10,000–100,000. The fin number (N = 4, 6, 8) and stem height–diameter ratio (s/D = 0.06, 0.08, 0.1) were individually varied to examine their effects on the Nu, f, and heat retention values. Water was used as the working fluid, entering the tube at 350 K and 4 bar, and a 50,000 W/m2 outer-wall flux was imposed. Mesh independence and turbulent viscosity ratio sensitivity analyses were performed, with the results favoring the SST k–ω turbulence model. The plain tube sat close to the Petukhov friction factor correlation and agreed well with the Dittus–Boelter correlation, validating the plain pipe case. The results indicate that the proposed horn-like fins pin coherent vortices to the wall, increasing the near-fin turbulent kinetic energy. The thermal performance factor peaked at 1.46 (N = 6, s/D = 0.06, Re = 80,000), where the Nusselt number was 110% above that of the plain tube; heat retained by the fluid also rose by 14%. Constant pumping power analysis showed a 28% maximum heat transfer improvement when all finned pipe cases were examined. A multiple regression analysis yielded a correlation equation between Nu, Re, Pr, s/D, and N, which achieved R2 = 0.992.

  • Open Access

    A Two-Species Finite Volume Scalar Model for Modeling the Diffusion of Poly(lactic-co-glycolic acid) into a Coronary Arterial Wall from a Single Half-Embedded Drug Eluting Stent Strut

    by Rodward L. Hewlin, Maegan Edwards, John P. Kizito

    This paper outlines the methodology and results for a two-species finite volume scalar computational drug transport model developed for simulating the mass transport of Poly(lactic-co-glycolic acid (PLGA)) from a half-embedded single strut implanted in a coronary arterial vessel wall. The mathematical drug transport model incorporates the convection-diffusion equation in scalar form (dimensionless) with a two-species (free-drug and bound-drug) mass transport setup, including reversible equilibrium reaction source terms for the free and bound-drug states to account for the pharmaco-kinetic reactions in the arterial wall. The relative reaction rates of the added source terms control the interconversion of the drug between the free and bound-drug states. The model is solved by a 2D finite-volume method for discretizing and solving the free and bound drug transport equations with anisotropic vascular drug diffusivities. This model is an improvement over previously developed models using the finite-difference and finite element method. A dimensionless characteristic scaling pre-analysis was conducted a priori to evaluate the significance of implementing the reaction source terms in the transport equations. This paper reports the findings of an investigation of the interstitial flow profile into the arterial wall and the free and bound drug diffusion profiles with a parametric study of varying the polymer drug concentration (low and high), tortuosity, porosity, and Peclet and DamKöhler numbers over the course of 400 h (16.67 days). The results also reveal how a single species drug delivery model that neglects both a reversible binding reaction source term and the porosity and tortuosity of the arterial wall cannot accurately predict the distribution of both the free and bound drug.


  • 2-kV 1-MW 20000-r/min Integrated Modular Motor Drive for Electrified Aircraft Propulsion

    by Jin Wang, Thomas M. Jahns, Patrick McCluskey, John Kizito, Bulent Sarlioglu, Robert Borjas, James A. Swanke, Yizhou Cong, Zhaoxi Yao, Hao Zeng, et al.

    The fight against global climate change demands the electrification of aircraft propulsion. One of the most significant and distinct challenges that future multi-megawatt electrified propulsion will face is high voltage at high altitudes, which could cause significant partial discharge and reduce the reliability of the propulsion system. Recognizing this challenge, a multi-disciplinary research team has proposed, designed, built, and preliminarily tested a 2-kV 1-MW 20,000 RPM integrated modular motor drive (IMMD) with an unprecedented weight power density of 9 kW/kg. This paper presents the architecture, major design approaches, test results of associated power electronics systems at the rated voltage and current, and preliminary test results of the full IMMD prototype. Full power and system-level altitude tests of the IMMD are already planned at the National Aeronautics and Space Administration (NASA’s) test facility.


  • Electromechanical actuator fan failure analysis and safety-critical design

    by W. Wu, Y. R. Lin, L. C. Chow, E. Gyasi, J. P. Kizito, Q. H. Leland

    The aim of this study is to use fault tree analysis to gain a better overall understanding of how to improve the reliability of a fan cooling system used to prevent electromechanical actuation systems (EMAs) from overheating. It is critical to manage the waste heat generated by EMAs on aircraft during all flight missions because EMA failure due to overheating could lead to an aircraft catastrophic failure. Heat generation by high-power-density power electronic devices and EMA motors has reached a heat flux density that thermal management of EMA by natural convection is not feasible, forced air cooling is needed. Since EMA motors and power electronic drives must operate at various altitudes and temperature throughout a flight mission, there is a need to develop a variable-speed fan that can operate efficiently and reliably over a wide range of pressure and temperature. To prevent EMAs from overheating and bring EMA failure probability to an acceptable level, a sturdy cooling fan which can operate under variable body forces due to aircraft maneuvering is required.


  • Open Access

    THERMAL ANALYSIS AND FLOW VISUALIZATION OF A FLAT LOOP HEAT PIPE

    by John P. Kizito, Monir Hossain

    A premiere free-access and peer-reviewed frontier journal site, serving the needs of the thermal-fluids community. See the latest research or submit an article. Quickly share your research with the global thermal-fluids community, for increased citations and impact at no cost.

  • STIRRING FREE SURFACE FLOWS DUE TO HORIZONTAL CIRCULATORY OSCILLATION OF A PARTIALLY FILLED CONTAINER

    by Hyeun Min Kim, John P. Kizito

    Mixing in a partially filled beaker or conical flask using oscillator shaker tables is routinely used for cultivation of biological cells. The present study seeks to gain a better understanding of fluid flow inside a beaker on a shaker table and the fluid motion influence on the mixing of cells within the fluid medium used for their cultivation. The imposed oscillatory motion on the beaker induces free surface deformations, which may cause laminar and low shear flow environments thus uniformly mixing the fluid medium. The low shear and uniformly mixed cell culture medium are requirements necessary for optimum cellular growth. In this study, fluid flow due to periodic and horizontal circulatory oscillations at a beaker boundary has been analyzed both numerically and experimentally. A partially filled beaker was modeled as a circular cylinder, and the cell culture medium was modeled as an incompressible fluid with a free and deformable liquid interface. The three-dimensional numerical model that can resolve the free surface deformation was based on finite difference scheme based on the “Marker-and-Cell” method. The method was used to determine the free surface deformation, its coupling to the flow dynamics within the beaker, and the resulting stirring effects. To verify the numerical model and validate the results, a simple flow visualization experiment was performed using an ion laser sheet to optically section flow chamber and reveal the flow pattern. The flow patterns obtained using numerical simulations were similar to those obtained experimentally through flow visualization. This study provides useful information that can be used to optimize the operation of a shaker table necessary to mix uniformly the cell culture, ensuring cell growth. In addition, this model can be extended to study the mixing processes in any chemical reactions within a partially filled container subjected to oscillatory forces.


  • Spray Cooling With Ammonia on Microstructured Surfaces: Performance Enhancement and Hysteresis Effect

    by Huseyin Bostanci, Daniel P. Rini, John P. Kizito, Louis C. Chow

    Experiments were performed to investigate spray cooling on microstructured surfaces. Surface modification techniques were utilized to obtain microscale indentations and protrusions on the heater surfaces. A smooth surface was also tested to have baseline data for comparison. Tests were conducted in a closed loop system with ammonia using RTI’s vapor atomized spray nozzles. Thick film resistors, simulating heat source, were mounted onto 1×2 cm2 heaters, and heat fluxes up to 500 W/cm2 (well below critical heat flux limit) were removed. Two nozzles each spraying 1 cm2 of the heater area used 96 ml/cm2 min(9.7 gal/in.2 h) liquid and 13.8 ml/cm2 s(11.3 ft3/in.2 h) vapor flow rate with only 48 kPa (7 psi) pressure drop. Comparison of cooling curves in the form of surface superheat (ΔTsat=Tsurf−Tsat) versus heat flux in the heating-up and cooling-down modes (for increasing and decreasing heat flux conditions) demonstrated substantial performance enhancement for both microstructured surfaces over smooth surface. At 500 W/cm2, the increases in the heat transfer coefficient for microstructured surfaces with protrusions and indentations were 112% and 49% over smooth surface, respectively. Moreover, results showed that smooth surface gives nearly identical cooling curves in the heating-up and cooling-down modes, while microstructured surfaces experience a hysteresis phenomenon depending on the surface roughness level and yields lower surface superheat in the cooling-down mode, compared with the heating-up mode, at a given heat flux. Microstructured surface with protrusions was further tested using two approaches to gain better understanding on hysteresis. Data indicated that microstructured surface helps retain the established three-phase contact lines, the regions where solid, liquid, and vapor phases meet, resulting in consistent cooling curve and hysteresis effect at varying heat flux conditions (as low as 25 W/cm2 for the present work). Data also confirmed a direct connection between hysteresis and thermal history of the heater.


  • Characteristic Timescales for Adherent Mammalian Cells

    by John Kizito, Karen Barlow, Simon Ostrach