MBMohamed Salem Badawi

Mohamed Salem Badawi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohamed Salem Badawi has a total of 96 co-authors. Here are the top co-authors by number of shared publications:

  • Ahmed M. El-Khatib

    Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria, Egypt

    10 shared publications
  • Abouzeid. A. Thabet

    Department of Medical Equipment Technology, Faculty of Allied Medical Sciences, Pharos University in Alexandria, Alexandria, Egypt

    9 shared publications
  • Mahmoud Ibrahim Abbas

    Physics Department, Faculty of Science, Alexandria University, 21511, Alexandria, Egypt

    9 shared publications
  • Mona M. Gouda

    Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria, Egypt

    7 shared publications
  • Abouzeid A. Thabet

    Department of Biomedical Equipment Technology, Faculty of Applied Health Sciences Technology, Pharos University, Alexandria, Egypt + Department of Educational Studies, University of Technology and Applied Sciences, Khasab, Oman

    6 shared publications
  • Mohamed E. Krar

    Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria, Egypt

    4 shared publications

Latest Publications

  • Mechanical Properties of Bi 2 O 3 / CuO Polypropylene Composite

    by Mona Shebly, M. Y. El Sayed, Amro Obeid, Mohamed S. Badawi, K. Habanjar, R. Awad

    A new class of polypropylene (PP) composites reinforced with binary oxide fillers (Bi 2 O 3 ‐CuO) was synthesized via compression molding. To the best of our knowledge, this is the first report on Bi 2 O 3 ‐CuO/PP composites, exploring both bulk and nanoparticle forms of the oxide fillers. Various amounts (5, 10, 15, and 20 wt%) of bulk and nanoparticles (Bi 2 O 3 ‐CuO) obtained via a mechanical process were used as fillers in PP. The prepared PP composites were characterized using X‐ray diffraction (XRD), ultraviolet–visible spectroscopy (UV–vis), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and energy‐dispersive X‐ray spectroscopy (EDX). Structural characterization via XRD, UV–vis, FTIR, and SEM/EDX confirmed the successful dispersion and morphological integration of the oxide fillers within the PP matrix. The mechanical properties of the composites were investigated using Vickers microhardness and tensile stress–strain tests. They were significantly enhanced with increasing filler content, particularly with nano‐sized fillers. Vickers microhardness increased by up to 32.44% for nano‐filled composites, and tensile tests showed improvements in Young's modulus, ultimate tensile strength, and toughness, especially at high strain rates. The nanocomposite containing 20 wt% filler exhibited the highest mechanical performance, suggesting optimal dispersion, interfacial adhesion, and load transfer. These results indicate the strong potential of Bi 2 O 3 ‐CuO nanofillers in engineering PP‐based composites with superior structural and functional properties.


  • Open Access

    Direct analytical efficiency assessment of the NaI(Tl) gamma-ray detector (Romashka)

    by Abouzeid A. Thabet, Ayman Hamzawy, Ivan N. Ruskov, Mohamed S. Badawi, Ivan A. Sirakov, Yuri N. Kopatch, Dimitar N. Grozdanov, Bohaysa A. Salem

    The present study focuses on the analytical and numerical calculations of the solid angle, effective solid angle, efficiency, and gamma-ray average path length within the detector materials as a function of the source position. This analysis is conducted for a Romashka module of the 4p NaI(Tl) gamma-ray detector array (NaGRaDA). NaGRaDA comprises 2 x 2p gamma-ray detector modules, with each module consisting of six NaI(Tl) crystals arranged in a compact configuration resembling a Daisy flower (known as Romashka in Russian). Each of the twelve scintillators has a unique design, distinguishing them in shape and size from conventional scintillation detectors. This type of 4p multi-detector system is applicable for measuring gamma radiation from samples exhibiting very low activity. It is employed in neutron activation analysis and prompt-gamma neutron activation analysis. Furthermore, this system can be instrumental in the experimental investigation of the characteristics of neutron-induced nuclear reactions. The results obtained throuh direct analytical and numerical methods will be compared with the upcoming comprehensive characterization of the upgraded and modernized Romashka NaGRaDA. This comparison will utilize GEANT4 simulations along-side standard point-type gamma-ray sources.


  • Open Access

    Gamma-ray attenuation characteristics of polypropylene filled with nano-sized and bulk Bi2O3 and CuO

    by Mona M. Gouda, Mona Shebly, Khulud Habanjar, Amro Obeid, Ramadan Awad, Mohamed S. Badawi

    Polypropylene was produced using compression molding and combined with bulk Bi2O3/CuO, and Bi2O3/CuO nanocomposites at various filler weight fractions (0%, 5%, 10%, 15%, and 20%). Gamma-ray energies from four radioactive sources (241Am, 133Ba, 137Cs, and 60Co), ranging from 59.53 keV to 1332.5 keV, were used to evaluate the radiation attenuation capabilities of the new PP/Bi2O3/CuO polymer composite. Parameters such as the mass attenuation coefficients, total molecular cross-section, effective atomic cross-section, total electronic cross-section, electron density, effective atomic number, half-value layer, tenth value layer, and relaxation length were examined. The results underscored the significant influence of both the size and weight fraction of Bi2O3/CuO fillers on the gamma-ray shielding ability of the polypropylene composite, particularly at lower gamma-ray energy levels. Pure lead, a traditional and widely used shielding material, was used as a reference to assess the effectiveness of the polypropylene composite's half-value layer. Polypropylene composites incorporating nano-sized Bi2O3/CuO exhibited notable improvements in attenuation parameters, highlighting their potential for radiation protection and gamma-ray shielding applications.


  • Assessment of X-ray shielding properties of polystyrene incorporated with different nano-sizes of PbO

    by Ahmad Firas Osman, Hanna El Balaa, Omar El Samad, Ramadan Awad, Mohamed S. Badawi

    PbO (lead oxide) particles with different sizes were incorporated into polystyrene (PS) with various weight fractions (0, 10, 15, 25, 35%). These novel PS/PbO nano-composites were produced by roll mill mixing and compressing molding techniques and then investigated for radiation attenuation of X-rays (N-series/ISO 4037) typically used in radiology. Properties of the PbO particles were studied by X-ray diffraction (XRD). Filler dispersion and elemental composition of the prepared nano-composites were characterized using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), revealing better filler distribution and fewer agglomerations with smaller PbO particle size. Linear and mass attenuation coefficients (μ and μm), total molecular and atomic cross-sections (σmol and σatm), as well as effective atomic number and electron density (Zeff and Neff), were calculated for the energy range N40 to N200. The influence of PbO weight percentage on the enhancement of the shielding parameters of the nano-composites was expected; however, the effect of PbO particle size was surprising. Linear and mass attenuation coefficients for PS/PbO composites increased gradually with increasing PbO concentrations, and composites with a small size of nanoparticles showed best performance. In addition, increasing PbO concentration raised the effective atomic number Zeff of the composite. Hence, the electron density Neff increased, which provided a higher total interaction cross-section of X-rays with the composites. Maximum radiation shielding was observed for PS/PbO(B). It is concluded that this material might be used in developping low-cost and lightweight X-ray shielding to be used in radiology.


  • Open Access

    Hybrid analytical method for calibrating a standard NaI(Tl) gamma-ray scintillation detector using a lateral hexagonal radioactive source

    by Mohamed S. Badawi, A. Hamzawy, Abouzeid A. Thabet

    In various fields of radiation and nuclear physics, research and its applications help in the management and control of human activities, especially in the analysis of nuclear waste and measurement of low activity environmental samples. The current study uses a hybrid analytical technique and a 152Eu lateral hexagonal radioactive source to calibrate a standard cylindrical NaI(Tl) γ-ray scintillation detector. The technique is a combination of experimental measurements and theoretical calculations because for each environmental and/or radioactive waste sample, a separate reference calibration source equivalent to samples of different compositions is required, which needs additional funding. This method is suitable for any source–detector geometry. It can be used to calculate the geometric, total, and full-energy peak efficiency and the P/T ratio using the model probability of detecting γ-radiation photons, in particular from a lateral hexagonal radioactive source. The detection probability can be mainly influenced by the direction of the γ-quantum motion. This can help build more realistic and complex models than the typical point source case, where simple integration is used to numerically calculate the efficiency of the detection system. Using this method, the self-attenuation and coincidence-summing effect can be calculated for any gamma source matrices. The results obtained can show how useful this technique can be for calibrating complex gamma-ray detectors with any type of gamma-ray source.


  • Open Access

    Analytical computation technique for calculation the effective geometrical solid angle and the efficiency of cubic scintillation crystal with side cylindrical hole

    by Mohamed S. Badawi, Abouzeid A. Thabet

    In the gamma-ray spectroscopy field, the radiometric examination for small quantities of natural samples is extremely significant. Therefore, the gamma-ray spectrometry calibration process must be prepared with good precision for several energies, matrices of sources or samples, and source-to-detector shapes. This manuscript considers a new uncomplicated analytical computation technique to calculate the effective geometrical solid angle and the efficiency of cubic scintillation crystal with a side cylindrical hole. The computations can be done by using a simple method, with a few essential limitations, that describes radioactive point sources located inside the side cylindrical hole and a high-efficiency cubic NaI(Tl) detector, come together with a low background as well. The technique stands on a trouble-free solid angle analytical formula for the detection system, using an accurate relation for the detector cavity, united with rough formulas controlling the interactions in the gamma-ray source and the materials introduced in between the source and the gamma-ray spectrometry. This new technique is not restricted to certain sources, because several source shapes can correspond to a homogeneous huge number of point sources and the detector geometry can be represented as a set of border points. The technique simply can be useful to obtain the full-energy peak efficiency in the future, challenging developments for low-energy gamma-ray spectroscopy.


  • Open Access

    Effect of PbO incorporation with different particle size on X-ray attenuation of polystyrene

    by Ahmad Firas Osman, Balaa Hanna El, Samad Omar El, Zainab Alsayed, Ramadan Awad, Mohamed S. Badawi

    Lead oxide (PbO) bulk and nanoparticles of two different sizes (A = 78 nm and B = 54 nm) are incorporated separately into the polystyrene matrix at various concentrations (0, 10, 15, 25, and 35 %) using roll mill mixing and compressing molding techniques. The X-ray narrow-spectrum series (N-series / ISO 4037-1) is then used to investigate the radiation attenuation capability of the novel polymer composite PS/PbO, as well as the effect of varying PbO particle sizes on shielding performance. The filler dispersion and chemical elemental analysis of the synthesized composite are investigated using scanning electron microscopy and energy-dispersive X-ray spectroscopy. To determine the mass attenuation coefficients ?m, samples with various thicknesses of the synthesized composite are examined using a range of X-ray energies, and the experimental data are compared to theoretical values from NIST databases (XCOM and FFAST). The results indicate that either increasing the filler weight percentage or, decreasing the filler particle size, enhanced the attenuation parameters throughout all energies. The composite containing the smallest nanosize of PbO exhibited the maximum radiation shielding efficacy among all combinations and therefore, might be used to develop low-cost and lightweight X-ray shields.


  • Open Access

    Study of mathematical functions to fit detector efficiency curve in gamma ray energy range from 59.54 keV up to 1408.01 keV

    by Abouzeid A. Thabet, Bohaysa A. Salem, Mohamed S. Badawi

    Recently, there have been several significant improvements in the area of the radiation detection system and its instruments, especially those using scintillation or semiconductor gamma ray detectors. Scientists and technicians are interested in studying this progress, which can be useful for the detector's operation and its basic properties, such as energy, shape, and efficiency calibration. In this work, an extended study of various mathematical formulas was conducted to obtain the efficiency best-fitting function, that covers the measured values from low to high energy regions. They can be used to represent the efficiency of a high-purity germanium detector in the regions where accuracy and maximum speed in optimizing the calibration process are very important for gamma spectroscopy. Determination of the activity of environmental samples mainly depends on the efficiency calibration curve of the detection system. The gamma ray energy in the range from 59.54 up to 1408.01 keV used in this work was obtained by using a set of standard radioactive gamma ray sources of certified intensity. The current data analysis shows that most of the mathematical formulas, which represent the fitting curve for the detector full-energy peak efficiency, were quite agreeable with the experimental results.