Reda Elshafey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Reda Elshafey has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Abd-Elgawad Radi
Department of Chemistry, Faculty of Science, Damietta University, 34517 Damietta, Egypt
5 shared publications - Mohamed Siaj
Department of Chemical Engineering and Biotechnological Engineering, Université de Sherbrooke, 2500 Boulevard de l’Université, Sherbrooke, QC J1K 2R1, Canada
4 shared publications - Ana C. Tavares
Centre Énergie Matériaux Télécommunications, Institut National de la Recherche Scientifique, 1650 Boulevard Lionel-Boulet, Varennes, QC J3X 1P7, Canada
3 shared publications Mohammed Zourob
Centre of Biomedical Engineering, Cranfield University, Cranfield, Bedfordshire MK43 0AL, U.K.
3 shared publications- Talaat A. Hegazy
Environmental Science Department, Faculty of Science, Damietta University, New Damietta, Egypt
3 shared publications Waganat Fakherel-Dien Ashour
Department of Chemistry, Faculty of Science, Damietta University, 34517 Damietta, Egypt
2 shared publications
Latest Publications
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 077518
Poly-Eriochrome Black T Decorated with Nickel Hydroxide Nanoparticles Modified Electrode for the Electrochemical Detection of Streptomycin and Probing its Interaction with Double-stranded DNA
We present a simple platform of poly-eriochrome Black T decorated with nickel hydroxide nanoparticles (Ni(OH)2NPs/PEBT) for the electrocatalytic oxidation of streptomycin (STRP) and probing its interaction with double-stranded DNA (ds-DNA). The electropolymerized eriochrome Black T modified glassy carbon electrode (GCE) was used to stabilize and synthesize Ni(OH)2NPs. The oxidation of STRP on Ni(OH)2NPs/PEBT/GCE mainly proceeded as a surface mechanism with the contribution of a diffusion-controlled process. A significant catalytic oxidation current of STRP was measured from an alkaline medium. It showed a dependence on the STRP concentrations in the range of 0.1 to 1.0 mM with a detection limit of 0.04 mM. The sensor has shown good recovery (85.3% to 90.2%, with RSD range of 1.27 to 8.83%) for the detection of STRP in diluted human serum. The interaction of STRP with ds-DNA was investigated from phosphate buffer pH 7.4 (0.2 M) using different electrode modifications (PEBT/GCE, and Ni(OH)2NPs/PEBT) in addition to bare GCE using voltammetric and impedance techniques. The binding constant of the STRP-DNA complex was calculated. Under the studied conditions, the interaction of ds-DNA with STRP in solution or on the surface of PEBT/GCE demonstrates their binding in intercalative and electrostatic modes.
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 077518
Poly-Eriochrome Black T Decorated with Nickel Hydroxide Nanoparticles Modified Electrode for the Electrochemical Detection of Streptomycin and Probing its Interaction with Double-stranded DNA
We present a simple platform of poly-eriochrome Black T decorated with nickel hydroxide nanoparticles (Ni(OH)2NPs/PEBT) for the electrocatalytic oxidation of streptomycin (STRP) and probing its interaction with double-stranded DNA (ds-DNA). The electropolymerized eriochrome Black T modified glassy carbon electrode (GCE) was used to stabilize and synthesize Ni(OH)2NPs. The oxidation of STRP on Ni(OH)2NPs/PEBT/GCE mainly proceeded as a surface mechanism with the contribution of a diffusion-controlled process. A significant catalytic oxidation current of STRP was measured from an alkaline medium. It showed a dependence on the STRP concentrations in the range of 0.1 to 1.0 mM with a detection limit of 0.04 mM. The sensor has shown good recovery (85.3% to 90.2%, with RSD range of 1.27 to 8.83%) for the detection of STRP in diluted human serum. The interaction of STRP with ds-DNA was investigated from phosphate buffer pH 7.4 (0.2 M) using different electrode modifications (PEBT/GCE, and Ni(OH)2NPs/PEBT) in addition to bare GCE using voltammetric and impedance techniques. The binding constant of the STRP-DNA complex was calculated. Under the studied conditions, the interaction of ds-DNA with STRP in solution or on the surface of PEBT/GCE demonstrates their binding in intercalative and electrostatic modes.
- 18 June 2022
- Published by Springer Nature in Electrocatalysis
- Vol. 13 (5) , 653-662
Glycerol Electrocatalytic Oxidation on Nickel Hydroxide Nanoparticles/Poly-Eriochrome Black T Modified Electrode
- 18 June 2022
- Published by Springer Nature in Electrocatalysis
- Vol. 13 (5) , 653-662
Glycerol Electrocatalytic Oxidation on Nickel Hydroxide Nanoparticles/Poly-Eriochrome Black T Modified Electrode
- 1 March 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 813, 171-177
Electrochemical impedance sensor for herbicide alachlor based on imprinted polymer receptor
- 1 March 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 813, 171-177
Electrochemical impedance sensor for herbicide alachlor based on imprinted polymer receptor
- 2 February 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (9) , 2733-2740
Au nanoparticle decorated graphene nanosheets for electrochemical immunosensing of p53 antibodies for cancer prognosis
The accurate quantification of the level of p53 antibodies in serum is crucial for cancer prognosis. We report a novel and sensitive label-free immunosensor based on gold nanoparticles (Au NPs) self-assembled onto electrochemically reduced graphene oxide (ERGO) for the detection of p53 antibodies. An electrografted p-aminophenol organic layer was used to immobilize graphene oxide (GO) onto the surface of screen printed carbon electrodes (SPCE). The Au NP/ERGO hybrid interface provides a large surface area for the effective immobilization of p53 antigens, as well as it ascertains the bioactivity and stability of immobilized p53 antigens. Scanning electron microscope, Raman and X-ray photoelectron spectroscopies were used to monitor the sensor fabrication and cyclic voltammetry was used to quantify the extent of Au NPs’ surface coverage by p53 antigens. Square wave voltammetry (SWV) of a [Fe(CN)6]3−/4− couple was employed to investigate the immunosensor fabrication and to monitor the binding events between p53 antigens and p53 antibodies. Under optimized experimental conditions, the biosensor displayed good sensitivity and specificity. The p53 antibodies were detected in a concentration as low as 0.088 pg mL−1 with a linear range from 0.1 pg mL−1 to 10 ng mL−1. The high sensitivity of the immunosensor may derive from the high loading of p53 antibodies on Au NPs which increases the number of binding events.
- 2 February 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (9) , 2733-2740
Au nanoparticle decorated graphene nanosheets for electrochemical immunosensing of p53 antibodies for cancer prognosis
The accurate quantification of the level of p53 antibodies in serum is crucial for cancer prognosis. We report a novel and sensitive label-free immunosensor based on gold nanoparticles (Au NPs) self-assembled onto electrochemically reduced graphene oxide (ERGO) for the detection of p53 antibodies. An electrografted p-aminophenol organic layer was used to immobilize graphene oxide (GO) onto the surface of screen printed carbon electrodes (SPCE). The Au NP/ERGO hybrid interface provides a large surface area for the effective immobilization of p53 antigens, as well as it ascertains the bioactivity and stability of immobilized p53 antigens. Scanning electron microscope, Raman and X-ray photoelectron spectroscopies were used to monitor the sensor fabrication and cyclic voltammetry was used to quantify the extent of Au NPs’ surface coverage by p53 antigens. Square wave voltammetry (SWV) of a [Fe(CN)6]3−/4− couple was employed to investigate the immunosensor fabrication and to monitor the binding events between p53 antigens and p53 antibodies. Under optimized experimental conditions, the biosensor displayed good sensitivity and specificity. The p53 antibodies were detected in a concentration as low as 0.088 pg mL−1 with a linear range from 0.1 pg mL−1 to 10 ng mL−1. The high sensitivity of the immunosensor may derive from the high loading of p53 antibodies on Au NPs which increases the number of binding events.
- 1 June 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 68, 295-302
DNA aptamers selection and characterization for development of label-free impedimetric aptasensor for neurotoxin anatoxin-a
- 1 June 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 68, 295-302
DNA aptamers selection and characterization for development of label-free impedimetric aptasensor for neurotoxin anatoxin-a
- 14 August 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (18) , 9196-9203
In Vitro Selection, Characterization, and Biosensing Application of High-Affinity Cylindrospermopsin-Targeting Aptamers
Contamination of freshwater with cyanotoxin cylindrospermopsin (CYN) represents a significant global concern for public health. The sensitive detection of CYN is necessary to effectively manage and control the treatment of water resources. Here we report a novel, highly sensitive label-free aptasensor for CYN analysis, using aptamers as specific receptors. We have selected the DNA aptamers from a diverse random library using the in vitro screening SELEX approach. The aptamers exhibited high affinity for CYN with Kd of nanomolar range. One aptamer exhibited conformational change upon CYN recognition (CD analysis) and was used to fabricate the label-free impedimetric aptasensor for CYN. A self-assembled monolayer from a disulfide-derivatized aptamer was formed on a gold electrode to fabricate the aptasensor. Upon CYN capturing to the aptasensor surface, a marked drop in the electron transfer resistance was obtained, which was used as the principle of detection of CYN. This resulted from the aptamer’s conformational change induced by CYN recognition. The present aptasensor could detect CYN with the limit of detection as low as 100 pM and a wide linear range of 0.1 to 80 nM. When mounted on the gold surface, the aptamer exhibited a lower dissociation constant for CYN than that observed in the fluorescence assay, implying that the anchoring of the aptamer on the Au surface improved its affinity to CYN. Moreover, the aptasensor showed high specificity toward other coexistent cyanobacterial toxins of microcystin-LR and Anatoxin-a. Further biosensor designs will be generated using those aptamers for simple and sensitive CYN monitoring.
- 14 August 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (18) , 9196-9203
In Vitro Selection, Characterization, and Biosensing Application of High-Affinity Cylindrospermopsin-Targeting Aptamers
Contamination of freshwater with cyanotoxin cylindrospermopsin (CYN) represents a significant global concern for public health. The sensitive detection of CYN is necessary to effectively manage and control the treatment of water resources. Here we report a novel, highly sensitive label-free aptasensor for CYN analysis, using aptamers as specific receptors. We have selected the DNA aptamers from a diverse random library using the in vitro screening SELEX approach. The aptamers exhibited high affinity for CYN with Kd of nanomolar range. One aptamer exhibited conformational change upon CYN recognition (CD analysis) and was used to fabricate the label-free impedimetric aptasensor for CYN. A self-assembled monolayer from a disulfide-derivatized aptamer was formed on a gold electrode to fabricate the aptasensor. Upon CYN capturing to the aptasensor surface, a marked drop in the electron transfer resistance was obtained, which was used as the principle of detection of CYN. This resulted from the aptamer’s conformational change induced by CYN recognition. The present aptasensor could detect CYN with the limit of detection as low as 100 pM and a wide linear range of 0.1 to 80 nM. When mounted on the gold surface, the aptamer exhibited a lower dissociation constant for CYN than that observed in the fluorescence assay, implying that the anchoring of the aptamer on the Au surface improved its affinity to CYN. Moreover, the aptasensor showed high specificity toward other coexistent cyanobacterial toxins of microcystin-LR and Anatoxin-a. Further biosensor designs will be generated using those aptamers for simple and sensitive CYN monitoring.
- 1 January 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 39 (1) , 220-225
Label-free impedimetric immunosensor for ultrasensitive detection of cancer marker Murine double minute 2 in brain tissue
- 1 January 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 39 (1) , 220-225
Label-free impedimetric immunosensor for ultrasensitive detection of cancer marker Murine double minute 2 in brain tissue
- 18 September 2012
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 67 (11) , 890-894
Electrochemical study of vinylsulphone azo dye Reactive Black 5 and its determination at a glassy carbon electrode
The electrochemical oxidation of vinylsulphone azo dye, Reactive Black 5 ( RB5), at a glassy carbon electrode has been carried out in phosphate buffer solutions in the pH range 2.85–11.79 employing...
- 18 September 2012
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 67 (11) , 890-894
Electrochemical study of vinylsulphone azo dye Reactive Black 5 and its determination at a glassy carbon electrode
The electrochemical oxidation of vinylsulphone azo dye, Reactive Black 5 ( RB5), at a glassy carbon electrode has been carried out in phosphate buffer solutions in the pH range 2.85–11.79 employing...