ABAnthony A. Birch

Anthony A. Birch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anthony A. Birch has a total of 127 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Model Predictive Valve Control to Assist Lung Pressure Profile Tracking

    by M. C. Thompson, C. T. Freeman, N. O’bRien, A.-M. Hughes, R. Marchbanks, A. Birch

    In U.K. 60 000 people have a brain tumor and typically are unaware of its presence until symptoms occur. Currently, there is no mass screening available due to limitations in diagnostic techniques. Measurement of intracranial pressure (ICP) [via tympanic membrane displacement (TMD)] is a potential low-cost, accessible solution; however, pressure fluctuations degrade its accuracy. This article solves the problem by assisting participants to precisely track airway pressure profiles. This stabilizes intrathoracic pressure, significantly reducing the fluctuations and enabling accurate diagnosis of ICP. This article develops and evaluates the first model of lung pressure tracking to embed volitional control action. A clinically feasible identification approach is then derived, together with a novel model predictive control (MPC) framework, embedding a valve control subsystem. Results with ten participants confirm that tracking is improved by an average of 22%.

  • Open Access

    Pulsatile tympanic membrane displacement is associated with cognitive score in healthy subjects

    by Anthony A. Birch, Wahbi K. El-Bouri, Robert J. Marchbanks, Laura A. Moore, Cherith M. Campbell-Bell, Christopher M. Kipps, Diederik O. Bulters


  • Open Access

    Estimating confidence intervals for cerebral autoregulation: a parametric bootstrap approach

    by Jack E D Bryant, Anthony A Birch, Ronney B Panerai, Dragana Nikolic, Diederik Bulters, David M Simpson

    Cerebral autoregulation (CA) refers to the ability of the brain vasculature to control blood flow in the face of changing blood pressure. One of the methods commonly used to assess cerebral autoregulation, especially in participants at rest, is the analysis of phase derived from transfer function analysis (TFA), relating arterial blood pressure (ABP) to cerebral blood flow (CBF). This and other indexes of CA can provide consistent results when comparing groups of subjects (e.g. patients and healthy controls or normocapnia and hypercapnia) but can be quite variable within and between individuals. The objective of this paper is to present a novel parametric bootstrap method, used to estimate the sampling distribution and hence confidence intervals (CIs) of the mean phase estimate in the low-frequency band, in order to optimise estimation of measures of CA function and allow more robust inferences on the status of CA from individual recordings. A set of simulations was used to verify the proposed method under controlled conditions. In 20 healthy adult volunteers (age 25.53.5 years), ABP and CBF velocity (CBFV) were measured at rest, using a Finometer device and Transcranial Doppler (applied to the middle cerebral artery), respectively. For each volunteer, five individual recordings were taken on different days, each approximately 18 min long. Phase was estimated using TFA. Analysis of recorded data showed widely changing CIs over the duration of recordings, which could be reduced when noisy data and frequencies with low coherence were excluded from the analysis (Wilcoxon signed rank test p = 0.0065). The TFA window-lengths of 50s gave smaller CIs than lengths of 100s ( p < 0.001) or 20s ( p < 0.001), challenging the usual recommendation of 100s. The method adds a much needed flexible statistical tool for CA analysis in individual recordings.


  • Open Access

    A vascular subtraction method for improving the variability of evoked tympanic membrane displacement measurements

    by Cherith M Campbell-Bell, Sammy J Sharif, Tianyu Zhang, Diederik O Bulters, Robert J Marchbanks, Anthony A Birch

    Objective . Evoked tympanic membrane displacement (TMD) measurements show a correlation with intracranial pressure (ICP). Attempts to use these measurements for non-invasive monitoring of ICP in patients have been limited by high measurement variability. Pulsing of the tympanic membrane at the cardiac frequency has been shown to be a significant source of the variability. In this study we describe a post processing method to remove the cardiac pulse waveform and assess the impact of this on the measurement and its repeatability. Approach . Three-hundred and sixteen healthy volunteers were recruited for evoked TMD measurements. The measurements were quantified by V m , defined as the mean displacement between the point of maximum inward displacement and the end of the stimulus. A sample of spontaneously pulsing TMDs was measured immediately before the evoked measurements. Simultaneous recording of the ECG allowed a heartbeat template to be extracted from the spontaneous data and subtracted from the evoked data. Intra-subject repeatability of V m was assessed from 20 repeats of the evoked measurement. Results with and without subtraction of the heartbeat template were compared. The difference was tested for significance using the Wilcoxon sign rank test. Main results . In left and right ears, both sitting and supine, application of the pulse correction significantly reduced the intra-subject variability of V m ( p value range 4.0 × 10 −27 to 2.0 × 10 −31 ). The average improvement was from 98 ± 6 nl to 56 ± 4 nl. Significance . The pulse subtraction technique substantially improves the repeatability of evoked TMD measurements. This justifies further investigations to assess the use of TMD measurements in clinical applications where non-invasive tracking of changes in ICP would be useful.


  • Vasomotion Drives Periarterial Drainage of Aβ from the Brain

    by Roxana O. Carare, Roxana Aldea, Diederik Bulters, Aiman Alzetani, Anthony A. Birch, Giles Richardson, Roy O. Weller


  • Quantifying the contribution of intracranial pressure and arterial blood pressure to spontaneous tympanic membrane displacement

    by Wahbi K. El-Bouri, Dario Vignali, Konstantina Iliadi, Diederik Bulters, Robert J Marchbanks, Anthony A Birch, David M Simpson

    Objective : Although previous studies have shown associations between patient symptoms/outcomes and the spontaneous tympanic membrane displacement (spTMD) pulse amplitude, the contribution of the underlying intracranial pressure (ICP) signal to the spTMD pulse remains largely unknown. We have assessed the relative contributions of ICP and arterial blood pressure (ABP) on spTMD at different frequencies in order to determine whether spTMD contains information about the ICP above and beyond that contained in the ABP. Approach : Eleven patients, who all had invasive ICP and ABP measurements in situ , were recruited from our intensive care unit. Their spTMD was recorded and the power spectral densities of the three signals, as well as coherences between the signals, were calculated in the range 0.1–5 Hz. Simple and multiple coherences, coupled with statistical tests using surrogate data, were carried out to quantify the relative contributions of ABP and ICP to spTMD. Main results : Most power of the signals was found to predominate at respiration rate, heart rate, and their harmonics, with little outside of these frequencies. Analysis of the simple coherences found a slight preference for ICP transmission, beyond that from ABP, to the spTMD at lower frequencies (7/11 patients at respiration, 7/10 patients at respiration 1st harmonic) which is reversed at the higher frequencies (2/11 patients at heart rate and its 1st harmonic). Both ICP and ABP were found to independently contribute to the spTMD. The multiple coherence reinforced that ICP is preferentially being transmitted at respiration and respiration 1st harmonic. Significance : Both ABP and ICP contribute independently to the spTMD signal, with most power occurring at clear physiological frequencies—respiration and harmonics and heart rate and harmonics. There is information shared between the ICP and spTMD that is not present in ABP. This analysis has indicated that lower frequencies appear to favour ICP as the driver for spTMD.


  • Does the Variability of Evoked Tympanic Membrane Displacement Data (V m) Increase as the Magnitude of the Pulse Amplitude Increases?

    by Sammy J. Sharif, Cherith M. Campbell-Bell, Diederik O. Bulters, Robert J. Marchbanks, Anthony A. Birch

    Objectives: Evoked tympanic membrane displacement (TMD) measurements, quantified by Vm, record small volume changes in the ear canal following stimulation of the acoustic reflex. Vm shows a correlation with intracranial pressure (ICP) and has been proposed as an option to non-invasively measure ICP. The spontaneous pulsing of the tympanic membrane, driven by the cardiovascular pulse, may contaminate the recordings and contribute to high measurement variability in some subjects. This study hypothesised that the larger the spontaneous vascular pulse, the larger the variability in Vm. Materials and methods: Spontaneous and evoked TMD data from each ear in the sitting and supine position were recorded from 100 healthy volunteers using the MMS-14 CCFP analyser. ECG was also recorded to identify each heartbeat. Using bespoke software written in Matlab, spontaneous data were analysed to produce average pulse amplitude (PA) waveforms and evoked data were analysed to calculate average Vm and its standard deviation. Averaged spontaneous PA was plotted against Vm variability and Pearson’s correlation coefficient was calculated to test for a significant linear relationship. Results: There was a strong positive correlation between PA and Vm variability in all conditions: left sitting, r = 0.758; left supine, r = 0.665; right sitting, r = 0.755; right supine, r = 0.513. All were significant at p < 0.001. Conclusion: This study shows that large Vm variability is associated with a large spontaneous vascular pulse. This suggests that efforts to reduce vascular pulsing from recordings, either by a subtraction technique during post-processing or ECG-gating of the evoking stimulus, may improve reliability of the Vm measurement.


  • Refining non-invasive techniques to measure intracranial pressure: comparing evoked and spontaneous tympanic membrane displacements

    by Laurie Christopher Finch, Robert J Marchbanks, Diederik Bulters, Anthony A Birch

    Objective : Tympanic membrane displacements (TMDs) are used to non-invasively gauge inner-ear fluid pressure. Inner-ear fluid pressure equalizes with intracranial pressure (ICP) via the cochlear aqueduct and therefore TMDs can indirectly evaluate ICP. We studied the relationship between two TMD modalities, evoked and spontaneous. Evoked TMD is a reflex response to an auditory stimulus and the established stapes-footplate mechanism explains how evoked TMDs change with ICP. Spontaneous TMD refers to a pulsatile TMD waveform expressed in the form of pulse amplitudes (TMD-PAs), the origins of which are poorly understood. We investigated whether both modalities respond similarly to an ICP change, suggesting a common mechanism. Approach : ICP was manipulated in 20 healthy volunteers by a postural change from sitting (lower ICP) to supine (higher ICP). Differences between paired sitting and supine TMD results generated ΔEvoked and ΔSpontaneous values. Main results : Evoked TMDs became more inward on lying supine while spontaneous TMDs became more outward. There was no evidence of a correlation between ΔEvoked and ΔSpontaneous (Right ears: r = −0.38, p = 0.10, 95% CI −0.75 to 0.21; Left ears: r = 0.34, p = 0.16, 95% CI −0.17 to 0.75). Significance : This suggests the stapes-footplate mechanism is not the primary mechanism explaining how spontaneous TMDs respond to changing ICP.


  • Reference intervals for the evoked tympanic membrane displacement measurement: a non-invasive measure of intracranial pressure*

    by Cherith M Campbell-Bell, Anthony A Birch, Dario Vignali, Diederik Bulters, Robert J Marchbanks

    Objective : Evoked tympanic membrane displacement (TMD) is a non-invasive technique for assessing intracranial pressure (ICP). The aim of this study was to define reference intervals (RIs) in the healthy population. Approach : Measurements were made in 154 healthy adults. Results were quantified by V m , which is the most frequently described TMD measurement. Distributions were determined for sitting and supine posture. Differences between right and left ears were explored using a Wilcoxon signed-rank test. Postural changes were used to assess pressure transfer between the cerebral spinal fluid (CSF) and the perilymph. Main results : The range in which 95% of scores fall is −283 to 722 nl ( M = 132 nl) left sitting, −232 to 623 nl ( M = 97 nl) right sitting, −543 to 717 nl ( M = 37 nl) left supine and −584 to 504 nl ( M = −15 nl) right supine. No significant difference was seen between the left and right ears in the sitting position; a significant difference was seen in the supine position. A significant effect of posture was seen for both the left and right ears. Postural changes indicated pressure transfer between the CSF and perilymph more often in the right ear (75.3%) than the left (61.9%). Pressure transfer could not be assumed in either ear for 13.4% of participants. Significance : We present the largest dataset of evoked TMD in healthy individuals and the first set of RIs for V m . A patient cohort with both invasive ICP and evoked TMD measurements is needed to validate the technique for clinical use.


  • Open Access

    Coherent averaging of pseudorandom binary stimuli: is the dynamic cerebral autoregulatory response symmetrical?

    by Emmanuel Katsogridakis, David M Simpson, Glen Bush, Lingke Fan, Anthony A Birch, Robert Allen, John F Potter, Ronney B Panerai

    Objective: Previous studies on cerebral autoregulation have shown the existence of hemispheric symmetry, which may be altered in stroke and traumatic brain injury. There is a paucity of data however on whether the response is symmetrical between those disturbances that cause cerebral hyperperfusion, to those that cause hypoperfusion. Our aim was to investigate whether the responses of cerebral autoregulation to haemodynamic stimuli of different directions are symmetrical. Approach: Using a previously described assessment method, we employed coherent averaging of the cerebral blood flow velocity (CBFV) responses to thigh cuff inflation and deflation, as driven by pseudorandom binary sequences, whilst simultaneously altering the inspired CO2. The symmetry of the autoregulatory response was assessed with regards to two parameters, its speed and gain. Using the first harmonic method, critical closing pressure (CrCP) and resistance area product (RAP) were estimated, and the gain of the autoregulatory response was calculated by performing linear regression between the coherent averages of arterial blood pressure (ABP) and CBFV, ABP and CrCP and finally ABP and RAP. A two-way repeated measures ANOVA was used to assess for the effect of the direction of change in ABP and the method of CO2 administration. Main results: Our results suggest that whilst the direction of ABP change does not have a significant effect, the effect of CO2 administration method is highly significant (p < 10−4). Significance: This is the first report to demonstrate the symmetry of the autoregulatory response to stimuli of different directions as well as the short term dynamics of RAP and CrCP under intermittent and constant hypercapnia. As haemodynamic stimulus direction does not appear to have an influence, our findings validate previous work done using different assessment methods.