Sam Khamis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sam Khamis has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Eli Carmeli
University of Haifa
7 shared publications - Barry Danino
Department of Pediatric Orthopedics, Dana Children’s Hospital, Tel-Aviv Sourasky Medical Center, 6, Weizmann St., Tel-Aviv 64239, Israel
4 shared publications Barry Danino
Department of Pediatric Orthopedics, Dana Children’s Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel; Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
3 shared publicationsShlomo Hayek
Department of Pediatric Orthopaedics, Dana Children’s Hospital, Tel Aviv Sourasky Medical Center (Affiliated to Sackler faculty of medicine, Tel Aviv University), Tel Aviv, Israel
3 shared publications- Dror Ovadia
Department of Pediatric Orthopedics, Dana Children’s Hospital, Tel Aviv Sourasky Medical Center, 6, Weizmann St., Tel Aviv 64239, Israel
2 shared publications - Moran Arad
Gait and Motion Analysis Laboratory, Department of Pediatric Orthopedics, Dana Children’s Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
2 shared publications
Latest Publications
- Open Access
- 24 April 2024
- Published by University Clinical Centre Tuzla in Central European Journal of Paediatrics
- Vol. 20 (1) , 51-56
The Foot-Gotten Variable – Modified Assessment for Measuring the Rotational Profile
The Foot-Gotten Variable – Modified Assessment for Measuring the Rotational Profile
- 24 April 2024
- Published by University Clinical Centre Tuzla in Central European Journal of Paediatrics
- Vol. 20 (1) , 51-56
Open AccessThe Foot-Gotten Variable – Modified Assessment for Measuring the Rotational Profile
The Foot-Gotten Variable – Modified Assessment for Measuring the Rotational Profile
- Open Access
- 18 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10898
Identifying Running Deviations in Long Distance Runners Utilizing Gait Profile Analysis: A Case Control Study
Objective: The goal of this study was to utilize Gait Profile Score (GPS) and Gait Deviation Index (GDI), to assess its capability of differentiating between injured and non-injured runners. Design: In total, 45 long-distance runners (15 non-injured, 30 injured), diagnosed with one of the following running related injuries, patella femoral pain syndrome, iliotibial pain syndrome, and medial tibial stress syndrome, were recruited. Methods: Data were obtained from a running analysis gait laboratory equipped with eight infrared motion-capturing cameras and a conventional treadmill. Running kinematics were recorded according to the Plug-In Gait model, measuring running deviations of the pelvis and lower extremities at a sampling rate of 200 Hz. GPS and GDI were calculated integrating pelvis and lower limb kinematics. Movement Analysis Profile results were compared between injured and non-injured runners. The non-parametric two-sample Wilcoxson test determined whether significant kinematic differences were observed. Results: Total GPS score significantly differed between the injured and non-injured runners. Not all running kinematics expressed by GDI differed between groups. Conclusions: GPS score was capable of discriminating between the injured and non-injured runners’ groups. This new running assessment method makes it possible to identify running injuries using a single numerical value and evaluate movements in individual joints.
- 18 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10898
Open AccessIdentifying Running Deviations in Long Distance Runners Utilizing Gait Profile Analysis: A Case Control Study
Objective: The goal of this study was to utilize Gait Profile Score (GPS) and Gait Deviation Index (GDI), to assess its capability of differentiating between injured and non-injured runners. Design: In total, 45 long-distance runners (15 non-injured, 30 injured), diagnosed with one of the following running related injuries, patella femoral pain syndrome, iliotibial pain syndrome, and medial tibial stress syndrome, were recruited. Methods: Data were obtained from a running analysis gait laboratory equipped with eight infrared motion-capturing cameras and a conventional treadmill. Running kinematics were recorded according to the Plug-In Gait model, measuring running deviations of the pelvis and lower extremities at a sampling rate of 200 Hz. GPS and GDI were calculated integrating pelvis and lower limb kinematics. Movement Analysis Profile results were compared between injured and non-injured runners. The non-parametric two-sample Wilcoxson test determined whether significant kinematic differences were observed. Results: Total GPS score significantly differed between the injured and non-injured runners. Not all running kinematics expressed by GDI differed between groups. Conclusions: GPS score was capable of discriminating between the injured and non-injured runners’ groups. This new running assessment method makes it possible to identify running injuries using a single numerical value and evaluate movements in individual joints.
- 15 January 2021
- Published by SAGE Publications in Technology and Health Care
- Vol. 29 (1) , 175-185
Dynamic leg length measurement is a valid method for detecting anatomic leg length discrepancy
BACKGROUND: Even though the importance of leg length discrepancy (LLD), with its potential of causing several pathological conditions or gait deviations, is well known, measuring LLD is still challenging with limited reliability and validity. OBJECTIVE: To assess the capability of the dynamic leg length (DLL) measurement in detecting the presence of anatomic LLD. METHODS: A lower limb x-ray was performed on 15 participants with suspected LLD in addition to a gait analysis study using a motion analysis system to measure DLL (the absolute distance from the hip joint centre to the heel, to the ankle joint centre and to the forefoot). Average DLLs were compared between sides for symmetry by the paired t-test at 51 sample points during the gait cycle in conjunction with the differences between the sides based on the maximal stance phase and minimal swing phase DLLs. Differences were correlated with anatomic LLD by Pearson correlation. RESULTS: No significant differences in DLLs between sides throughout the gait cycle were found. Significant differences between sides were found between the maximal stance and minimal swing phase DLLs. CONCLUSIONS: DLL measurement is capable of detecting an anatomic leg length difference based on functional changes in leg length and functional discrepancy.
- 15 January 2021
- Published by SAGE Publications in Technology and Health Care
- Vol. 29 (1) , 175-185
Dynamic leg length measurement is a valid method for detecting anatomic leg length discrepancy
BACKGROUND: Even though the importance of leg length discrepancy (LLD), with its potential of causing several pathological conditions or gait deviations, is well known, measuring LLD is still challenging with limited reliability and validity. OBJECTIVE: To assess the capability of the dynamic leg length (DLL) measurement in detecting the presence of anatomic LLD. METHODS: A lower limb x-ray was performed on 15 participants with suspected LLD in addition to a gait analysis study using a motion analysis system to measure DLL (the absolute distance from the hip joint centre to the heel, to the ankle joint centre and to the forefoot). Average DLLs were compared between sides for symmetry by the paired t-test at 51 sample points during the gait cycle in conjunction with the differences between the sides based on the maximal stance phase and minimal swing phase DLLs. Differences were correlated with anatomic LLD by Pearson correlation. RESULTS: No significant differences in DLLs between sides throughout the gait cycle were found. Significant differences between sides were found between the maximal stance and minimal swing phase DLLs. CONCLUSIONS: DLL measurement is capable of detecting an anatomic leg length difference based on functional changes in leg length and functional discrepancy.
- Open Access
Measuring Dynamic Leg Length during Normal Gait
Dynamic leg length [DLL] is a resultant factor of anatomic leg length and lower limb movement that is measured by the distance from the hip to the heel, ankle, and forefoot during the gait cycle. The aim of this study was to present DLL measurement during normal gait. Forty healthy participants underwent a gait evaluation using a motion analysis system. The average DLLs were compared between sides during the gait cycle using the paired t-test at 51 sample points. Time of maximal and minimal DLLs and the ratio between maximal and minimal DLLs during the gait cycle were calculated. DLLs were found to be consistent, indicated by a within standard deviation of 0.103]. DLL patterns and time of maximal and minimal DLLs were established. The ratio between maximal DLLs during the stance phase and minimal DLLs during the swing phase was also defined and found to be symmetrical. Normative data of DLL measures were set with respect to magnitude and pattern during the gait cycle. These data might serve as a reference for abnormal gait deviation reflected by abnormal DLLs, thus promoting a new perspective in gait analysis.
Open AccessMeasuring Dynamic Leg Length during Normal Gait
Dynamic leg length [DLL] is a resultant factor of anatomic leg length and lower limb movement that is measured by the distance from the hip to the heel, ankle, and forefoot during the gait cycle. The aim of this study was to present DLL measurement during normal gait. Forty healthy participants underwent a gait evaluation using a motion analysis system. The average DLLs were compared between sides during the gait cycle using the paired t-test at 51 sample points. Time of maximal and minimal DLLs and the ratio between maximal and minimal DLLs during the gait cycle were calculated. DLLs were found to be consistent, indicated by a within standard deviation of 0.103]. DLL patterns and time of maximal and minimal DLLs were established. The ratio between maximal DLLs during the stance phase and minimal DLLs during the swing phase was also defined and found to be symmetrical. Normative data of DLL measures were set with respect to magnitude and pattern during the gait cycle. These data might serve as a reference for abnormal gait deviation reflected by abnormal DLLs, thus promoting a new perspective in gait analysis.
- Open Access
- 18 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1979
Correlation between Gait Asymmetry and Leg Length Discrepancy—What Is the Role of Clinical Abnormalities?
Reducing the effect of leg length discrepancy (LLD) on gait abnormalities while other abnormal conditions such as spasticity, joint contractures or weak muscle strength are exhibited is challenging. This study aimed to evaluate the impact of mild LLD on lower limb biomechanics, on participants with anatomic LLD with and without other clinical abnormalities. A motion capture system was utilized on 32 participants to measure lower limb kinematics and dynamic leg length (DLL) throughout the gait cycle, calculated as the absolute distance from the hip joint center, either to the heel, ankle joint center, or forefoot. The Pearson correlation coefficient found that LLD was associated with 5 kinematic variables only when LLD appeared with no other clinical abnormalities present (r = 0.574 – 0.846, p < 0.05). When clinical abnormalities were present, the random forest classification accuracy was lower (64% versus 80%), implying that the used kinematics are low predictors for anatomic LLD, revealing a higher asymmetrical clearance index (the difference between the maximal stance phase and the minimal contra-lateral swing phase DLL) and a different kinematic variable importance index. Clinical abnormalities in pathological gait will in all probability significantly affect gait deviations, affirming mild anatomic LLD as inconsequential. A functional measurement can offer a better estimate as to the side and extent of the functional discrepancy.
- 18 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (10) , 1979
Open AccessCorrelation between Gait Asymmetry and Leg Length Discrepancy—What Is the Role of Clinical Abnormalities?
Reducing the effect of leg length discrepancy (LLD) on gait abnormalities while other abnormal conditions such as spasticity, joint contractures or weak muscle strength are exhibited is challenging. This study aimed to evaluate the impact of mild LLD on lower limb biomechanics, on participants with anatomic LLD with and without other clinical abnormalities. A motion capture system was utilized on 32 participants to measure lower limb kinematics and dynamic leg length (DLL) throughout the gait cycle, calculated as the absolute distance from the hip joint center, either to the heel, ankle joint center, or forefoot. The Pearson correlation coefficient found that LLD was associated with 5 kinematic variables only when LLD appeared with no other clinical abnormalities present (r = 0.574 – 0.846, p < 0.05). When clinical abnormalities were present, the random forest classification accuracy was lower (64% versus 80%), implying that the used kinematics are low predictors for anatomic LLD, revealing a higher asymmetrical clearance index (the difference between the maximal stance phase and the minimal contra-lateral swing phase DLL) and a different kinematic variable importance index. Clinical abnormalities in pathological gait will in all probability significantly affect gait deviations, affirming mild anatomic LLD as inconsequential. A functional measurement can offer a better estimate as to the side and extent of the functional discrepancy.
- 27 June 2018
- Published by Elsevier in Gait & Posture
- Vol. 65, 261-262
P 019 - The effect of simulated leg length discrepancy on lower limb biomechanics during gait
- 27 June 2018
- Published by Elsevier in Gait & Posture
- Vol. 65, 261-262
P 019 - The effect of simulated leg length discrepancy on lower limb biomechanics during gait
- 1 January 2018
- Published by Elsevier in European Journal of Paediatric Neurology
- Vol. 22 (1) , 7-16
Is functional electrical stimulation an alternative for orthotics in patients with cerebral palsy? A literature review
- 1 January 2018
- Published by Elsevier in European Journal of Paediatric Neurology
- Vol. 22 (1) , 7-16
Is functional electrical stimulation an alternative for orthotics in patients with cerebral palsy? A literature review
- 4 December 2017
- Published by Taylor & Francis in Measurement in Physical Education and Exercise Science
- Vol. 22 (2) , 145-153
Measuring clearance mechanics based on dynamic leg length
The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant asymmetry was observed during stance, initial and terminal swing phases, where the hemiplegic limb was found shorter by using a paired t-test at 51 sample points (p < .05). The hemiplegic side was restricted in achieving maximal length during terminal swing. The ratio between the maximal dynamic leg length during the stance phase to minimal dynamic leg length during the swing phase was found higher on the non-involved side and lower on the hemiplegic side (p < .05). Quantifying clearance mechanics based on dynamic leg length can provide an additional insight into the analysis of gait patterns and might assist in detecting time of abnormal kinematic deviations.
- 4 December 2017
- Published by Taylor & Francis in Measurement in Physical Education and Exercise Science
- Vol. 22 (2) , 145-153
Measuring clearance mechanics based on dynamic leg length
The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant asymmetry was observed during stance, initial and terminal swing phases, where the hemiplegic limb was found shorter by using a paired t-test at 51 sample points (p < .05). The hemiplegic side was restricted in achieving maximal length during terminal swing. The ratio between the maximal dynamic leg length during the stance phase to minimal dynamic leg length during the swing phase was found higher on the non-involved side and lower on the hemiplegic side (p < .05). Quantifying clearance mechanics based on dynamic leg length can provide an additional insight into the analysis of gait patterns and might assist in detecting time of abnormal kinematic deviations.
- Open Access
- 8 September 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (9) , 926
Detecting Anatomical Leg Length Discrepancy Using the Plug-in-Gait Model
Leg length discrepancy (LLD) is a significant factor influencing several pathological conditions. Gait analysis is based on biomechanical gait models calculating joint kinematics; however, no previous study has validated its ability to detect anatomical LLD. The aim of the present study was to compare the validity of the Vicon® Plug-in-Gait-model (PGM) in measuring femur and tibia segmental length discrepancy with measurements attained by X-ray. Fifteen participants with suspected leg length discrepancies underwent a lower limb X-ray and a standing calibration trial using a motion analysis system (Vicon®, Oxford Metrics, UK). Femur and tibia segment lengths were deducted from both measurements. No differences were found when measuring the discrepancies between sides for the femur (p = 0.3) and tibia (p = 0.45) segmental length. A high correlation was found between methods (r = 0.808–0.962, p < 0.001), however, a significant difference was observed when measuring the femur and tibia length (p < 0.0001). PGM was found to be a valid model in detecting segmental length discrepancy when based on the location of the joint centers compared to X-ray. A variance was noted in the femur and tibial segmental length. The impact of this inconsistency in segmental length on kinematics and kinetics should be further evaluated.
- 8 September 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (9) , 926
Open AccessDetecting Anatomical Leg Length Discrepancy Using the Plug-in-Gait Model
Leg length discrepancy (LLD) is a significant factor influencing several pathological conditions. Gait analysis is based on biomechanical gait models calculating joint kinematics; however, no previous study has validated its ability to detect anatomical LLD. The aim of the present study was to compare the validity of the Vicon® Plug-in-Gait-model (PGM) in measuring femur and tibia segmental length discrepancy with measurements attained by X-ray. Fifteen participants with suspected leg length discrepancies underwent a lower limb X-ray and a standing calibration trial using a motion analysis system (Vicon®, Oxford Metrics, UK). Femur and tibia segment lengths were deducted from both measurements. No differences were found when measuring the discrepancies between sides for the femur (p = 0.3) and tibia (p = 0.45) segmental length. A high correlation was found between methods (r = 0.808–0.962, p < 0.001), however, a significant difference was observed when measuring the femur and tibia length (p < 0.0001). PGM was found to be a valid model in detecting segmental length discrepancy when based on the location of the joint centers compared to X-ray. A variance was noted in the femur and tibial segmental length. The impact of this inconsistency in segmental length on kinematics and kinetics should be further evaluated.
- 1 September 2017
- Published by Elsevier in Gait & Posture
- Vol. 57, 115-123
Relationship and significance of gait deviations associated with limb length discrepancy: A systematic review
- 1 September 2017
- Published by Elsevier in Gait & Posture
- Vol. 57, 115-123
Relationship and significance of gait deviations associated with limb length discrepancy: A systematic review