Latest Publications

  • Cybersecurity of Protection Systems in Digital Substations: A Systematic Survey on Vulnerabilities and Defenses

    by Ali Doostmohammadi, Amir Ameli, Mohsen Ghafouri, Mohammadreza F. M. Arani, Ehab F. El-Saadany

  • Open Access

    Protecting Local Wireless Charging Stations Against Cyber-Physical Attacks by Weaponized EVs

    by Samaneh Yazdanipour, Mohammadreza Fakhari Moghaddam Arani, Amir Abiri Jahromi, V. S. R. Varaprasad Oruganti, Sheldon S. Williamson

    Wireless charging stations are gaining attention due to their ability to reduce the weight and size of the battery in the electric vehicles and increase the battery life time. Wireless charging stations are also an attractive technology for autonomous vehicle charging as they do not need human intervention. Although the design of wireless charging stations has been investigated thoroughly, the cyber-physical security posture of wireless charging stations has remained underexplored. In this paper, we examine the vulnerability of wireless charging stations to cyber-physical attacks by weaponized electric vehicles. In this paper, a weaponized EV is defined as a vehicle intentionally modified with a rogue device connected to its internal communication network capable of injecting falsified information into the electric vehicle communication controller, point-to-point communication channels, and the battery management system. Small-signal modelling is used to study the dynamics of cyber-physical systems in wireless charging, while phasor circuit analysis is used to evaluate the impact of cyber-physical attacks on wireless charging stations. A mitigation strategy is further proposed to improve the resilience of the wireless charging stations to cyber-physical attacks. Time domain simulations are employed to test and verify the analyses and the proposed mitigation strategy.

  • Open Access

    A scalable game-theoretic framework for secure and decentralized energy sharing in renewable energy communities

    by Saber Ghashghaei, Giuseppe Sciumé, Eleonora Riva Sanseverino, Salvatore Favuzza, Mohammadreza Fakhri Moghaddam Arani

  • Open Access

    Quantum Computing Threats to IEC 62351 Cryptographic Algorithms: An In-Depth Analysis

    by Brian Goncalves, Arash Mahari, Atefeh Mashatan, Mohammadreza F. M. Arani, Marthe Kassouf

    Quantum computing, power systems, and communication represent three distinct fields that converge to address the complexities involved in the quantum cybersecurity of power systems. Quantum computers present a serious threat to cybersecurity by potentially affecting traditional encryption methods, which could compromise sensitive data and disrupt the integrity of secure communications. As communication and data transformation serve as the backbone of modern power grid monitoring, control, and protection systems, the growing awareness of cyber-vulnerabilities in power grids has made cybersecurity a pressing concern. The IEC 62351 standard family has been developed to provide security recommendations for various power system communication protocols and is emerging as a leading cybersecurity standard for power systems. However, the vulnerabilities of these standards to quantum threats have yet to be fully explored. This article conducts a comprehensive analysis of security threats and vulnerabilities in modern power systems against quantum attacks. It systematically reviews the security considerations outlined in IEC 62351 for safeguarding various aspects, such as IEC 61850 messages, key management, XML file security, and TCP/IP profiles. The analysis reveals that almost all encryption algorithms mandated and recommended by IEC 62351 are vulnerable to quantum attacks such as Grover's and Shor's algorithms.

  • Open Access

    Pole Slipping in Droop-Based Grid-Forming Inverters

    by Negar Karimipour, Hansi Wijayalath Arachchilage, Amir Abiri Jahromi, Behrooz Bahrani, Mohammadreza F. M. Arani

    Integration of grid-forming inverter-based resources is considered as a viable solution to address the challenges associated with the dynamics of power systems with high penetration levels of inverter-based resources. Yet, various aspects of dynamic behaviour of grid-forming inverters during disturbances have remained unknown. This paper for the first time introduces the concept of pole slipping in grid forming inverters, referring to the loss of synchronism where the inverter’s internal phase angle deviates beyond 180° with respect to the grid, similar to synchronous generators losing step. It is revealed that this event in grid forming inverters can be stable or unstable. The differences between stable and unstable pole slipping are highlighted. The determining factors for the occurrence of stable and unstable pole slipping in grid forming inverters and equipment-level implications of pole slipping are identified and studied. A solution is proposed to mitigate stable and unstable pole slipping in grid-forming inverters by adjusting the operating reference power during the disturbance. The validity of the proposed concept of pole slipping in grid forming inverters and the proposed solution is tested and verified through extensive time-domain simulations and experimental results. The results verify that pole slipping is more likely to happen in high short circuit ratios (SCRs). It is revealed that unstable pole slipping does not occur at SCRs lower than 3.5. Simulation and experimental results demonstrate that a phase jump as small as 10° may lead to instability in a grid with SCRs equal or higher than 10. This is while in lower SCRs such phase jumps result in long fault recovery without causing pole slipping.


  • Open Access

    A cumulative sum-based protection method for inverter-interfaced microgrids

    by Behzad Asle Mohammad Alizadeh, Mohammadreza F․m․ Arani, Seyed Fariborz Zarei


  • Top Cited Papers

    Cyber-Physical Interdependence for Power System Operation and Control

    by Ioannis Zografopoulos, Ankur Srivastava, Charalambos Konstantinou, Junbo Zhao, Amir Abiri Jahromi, Astha Chawla, Bang Nguyen, Bu Siqi, Chendan Li, Fei Teng, et al.

    This paper summarizes the technical endeavors undertaken by the Task Force (TF) on Cyber-Physical Interdependence for Power System Operation and Control. The TF was established to investigate the cyber-physical interdependence of critical power system elements and their influence on the operation and control of energy systems. State-of-the-art analysis techniques, including co-simulation and digital twin technologies, are employed to address various layers of interdependence between cyber and physical systems, facilitating the identification of potential threats and vulnerabilities. The paper examines prospective trajectories for resilient cyber-physical systems and outlines the educational and workforce training imperatives for addressing cybersecurity threats in contemporary power systems. Furthermore, concluding remarks and future recommendations are provided to mitigate the inherent vulnerabilities within the extensively interoperable grid infrastructure.


  • False Data Injection Attack Detection and Localization Framework in Power Distribution Systems Using a Novel Ensemble of CNNs and Explainable Artificial Intelligence

    by Mohammad Reza Dehbozorgi, Mohammad Rastegar, Mohammadreza Fakhari Moghaddam Arani

    Cyber-physical power systems are vulnerable to cyber-attacks, especially false data injection attacks (FDIAs). FDIAs against distribution system state estimation (DSSE), which alter state estimation (SE) by changing meter readings, have received researchers' attention in recent years. A common defense against FDIAs in the literature is the use of labeled data to train classifiers as FDIA detectors. However, this approach's performance can be limited by the highly imbalanced nature of FDIA datasets. The black box characteristics of the machine learning models can make them hard to trust and adopt in important applications. Hence, we propose an innovative explainable artificial intelligence (XAI)-enhanced ensemble-based detection and localization model that leverages convolutional neural networks (CNNs) and support vector machine (SVM). The ensemble model uses SVM to merge various spatiotemporal CNNs' outputs. Training these CNNs on under-sampled subsets of the majority class and using their ensemble addresses class imbalance. This paper leverages XAI to enhance the interpretability of the detection process and improve localization accuracy. The localization process uses the outputs of an XAI technique, gradient-weighted class activation mapping, to aid the majority-voting-based localization ensemble model. Our model can also detect FDIAs during the distribution feeder's topology changes. Extensive simulations on IEEE 13-bus and IEEE 123-bus feeders prove the proposed under-sampling-based detection approach as an alternative to prevalent over-sampling methods like generative adversarial networks (GANs), offering a novel solution to class imbalance challenges. The paper also provides a comprehensive analysis of the proposed spatiotemporal model's performance, demonstrating its superiority over temporal CNNs.


  • Open Access

    Investigating Disturbance‐Induced Misoperation of Grid‐Following Inverter‐Based Resources

    by Negar Karimipour, Mohammadreza F. M. Arani, Amir Abiri Jahromi

    The rapid integration of grid‐following inverter‐based resources (GFL‐IBRs) has increased the importance of their dynamic behaviour during disturbances. Simultaneously, there are increasing number of reports about the misoperation or inadvertent disconnection of GFL‐IBRs during disturbances. This paper attempts to shed light on one of the potential root causes of disturbance‐induced misoperations of GFL‐IBRs. A framework is presented to quantify voltage drop and voltage phase angle jump that appear at the terminals of GFL‐IBRs immediately after the inception of various events in the grid such as faults, and tripping of generators and transmission lines. We demonstrate voltage drop and voltage phase angle jump in the upstream grid due to various disturbances may transform into severe voltage drop and voltage phase angle jump at the terminals of GFL‐IBRs. The combination of voltage drop and voltage phase angle jump that appear at the terminals of GFL‐IBRs is identified as one of the root causes of their misoperation. Therefore, system‐wide studies are required to evaluate the dynamic performance of GFL‐IBRs rather than sole compliance with standards. The importance of system‐wide studies is demonstrated through IEEE 39‐bus test system. The impact of voltage drop and voltage phase angle jump in the upstream grid on the dynamic performance of GFL‐IBRs is demonstrated using electromagnetic transient studies.