Vyacheslav V. Komarov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vyacheslav V. Komarov has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
V. P. Meshchanov
NIKA-SVCh Scientific-Industrial Enterprise, 410040, Saratov, Russia
3 shared publicationsA. I. Korchagin
Mytishchi Scientific-Research Institute of Radiometric Devices, 141002, Mytishchi, Moscow oblast, Russia
2 shared publicationsValeriy P. Meschanov
JSC NIKA-SVCH, Saratov, Russian Federation
2 shared publications- Valeriy P. Meschanov
«Научно-производственное предприятие «НИКА-СВЧ
2 shared publications - Vil Baiburin
Yuri Gagarin State Technical University of Saratov
2 shared publications A. A. Lopatin
Research and Production Enterprise “NIKA-SVCh
1 shared publication
Latest Publications
- 1 January 2025
- Published by Publishing house "Radiotekhnika" in Radioengineering
- p. 184-188
Electrodynamic modeling of the operating chamber of a microwave sterilizer with slot excitation element
Sterilization of surgery instruments in an important preliminary stage of any medical operation. Microwave energy can be successfully used for these purposes. The distribution of electromagnetic fields of different modes in the rectangular cavity chamber of a microwave sterilizer mainly depends on the excitation element of the resonator. At the same time, the influence of the shape and location of this element in the design of the sterilizer remains poorly understood. Analysis of electromagnetic fields near the surface of metal objects irradiated with microwave energy for various options for placing a slot excitation element on the walls of the operating chamber was the goal of this work. Using a 3-D numerical model based on the finite element method, the tangential component of the electric field above the surface of a metal plate irradiated with a microwave energy in the operating chamber of a microwave sterilizer was investigated. In this case, the plate is placed in a plastic container with an immersion medium (water), the electrophysical properties of which depend on the temperature. The factors that have the greatest influence on the magnitude of the field strength in the interaction region have been established. The obtained numerical data can be used to reduce the metal consumption of the waveguide excitation element of the operating chamber of the sterilizer, which is currently used, and at the same time to increase the efficiency of microwave decontamination of pathological microflora during sterilization of medical instruments.
- 1 January 2025
- Published by Publishing house "Radiotekhnika" in Radioengineering
- p. 184-188
Electrodynamic modeling of the operating chamber of a microwave sterilizer with slot excitation element
Sterilization of surgery instruments in an important preliminary stage of any medical operation. Microwave energy can be successfully used for these purposes. The distribution of electromagnetic fields of different modes in the rectangular cavity chamber of a microwave sterilizer mainly depends on the excitation element of the resonator. At the same time, the influence of the shape and location of this element in the design of the sterilizer remains poorly understood. Analysis of electromagnetic fields near the surface of metal objects irradiated with microwave energy for various options for placing a slot excitation element on the walls of the operating chamber was the goal of this work. Using a 3-D numerical model based on the finite element method, the tangential component of the electric field above the surface of a metal plate irradiated with a microwave energy in the operating chamber of a microwave sterilizer was investigated. In this case, the plate is placed in a plastic container with an immersion medium (water), the electrophysical properties of which depend on the temperature. The factors that have the greatest influence on the magnitude of the field strength in the interaction region have been established. The obtained numerical data can be used to reduce the metal consumption of the waveguide excitation element of the operating chamber of the sterilizer, which is currently used, and at the same time to increase the efficiency of microwave decontamination of pathological microflora during sterilization of medical instruments.
- Open Access
- 31 December 2022
- Published by Povolzhskiy State University of Telecommunications and Informatics in Physics of Wave Processes and Radio Systems
- Vol. 25 (4) , 52-58
Modeling of electrodynamic parameters of microwave sterilizer
For the sterilization of medical instruments, a technology for their immersion heat treatment with intense microwave radiation at the frequency of 2,45 GHz is analyzed. The advantages of this technology in comparison with traditional methods are shown. An electromagnetic model of a microwave sterilizer for surgical tools was built, taking into account the temperature dependence of the complex dielectric permittivity of the immersion medium (water). A rectangular cavity with a waveguide excitation was used as its basic unit. With the help of a numerical model on the finite element method, the values of the reflected and absorbed power, as well as the heating rate of water in the sterilizer for an operating power of 600 W, were determined. The analysis of thermal processes, performed according to a simplified method, showed a rather high efficiency of such device, which provides a high heating rate at a given frequency.
- 31 December 2022
- Published by Povolzhskiy State University of Telecommunications and Informatics in Physics of Wave Processes and Radio Systems
- Vol. 25 (4) , 52-58
Open AccessModeling of electrodynamic parameters of microwave sterilizer
For the sterilization of medical instruments, a technology for their immersion heat treatment with intense microwave radiation at the frequency of 2,45 GHz is analyzed. The advantages of this technology in comparison with traditional methods are shown. An electromagnetic model of a microwave sterilizer for surgical tools was built, taking into account the temperature dependence of the complex dielectric permittivity of the immersion medium (water). A rectangular cavity with a waveguide excitation was used as its basic unit. With the help of a numerical model on the finite element method, the values of the reflected and absorbed power, as well as the heating rate of water in the sterilizer for an operating power of 600 W, were determined. The analysis of thermal processes, performed according to a simplified method, showed a rather high efficiency of such device, which provides a high heating rate at a given frequency.
- Open Access
- 29 October 2022
- Published by Russian Research Anti-Plague Institute Microbe in Problems of Particularly Dangerous Infections
- No. 3,p. 70-74
Exposure of Food Samples to Pulsed Microwave Radiation to Increase their Microbiological Safety and Shelf Life
The aim of the study was to increase the efficiency of decontamination of biological material and media (by the example of food products) by pulsed (non-thermal) radio emission and asses the prospects of its application in medicine and biology.Materials and methods. To achieve the goal an experimental setup has been designed, manufactured and tested, which makes it possible to study the process of exposure of biological materials and media to pulsed (non-thermal) radio emission, in particular, by the example of food products. The basis of the method is optimum control of the electro-physical parameters of the irradiating radio signal, depending on the type of the irradiated object. We used pulsed magnetrons with operating frequency of (2.45±0.05) GHz, authorized for bio-medical research, generating pulsed radiation with an adjustable power within the range of 0.1...10 kW. The pulse repetition rate with a duty cycle of 500...10000 is 0.1...5 kHz. The setup has an operating chamber into which the test sample is placed, as well as additional elements of magnetron protection and measuring the parameters of the microwave power incident on biological object.Results and discussion. The setup has been successfully used to irradiate various food samples with pathogenic micro flora (Salmonella spp. etc.) with pulsed microwave radiation. In particular, as shown by the studies, the arithmetic mean number of pathogenic bacteria in the irradiated samples of minced meat decreased by 27.5 times after 28 days of storage as compared to the control group of non-irradiated samples. Preliminary conducted experiments in the field of investigating the effect of microwave radiation on the process of cell division and other aspects of electromagnetic field influence on pathological microorganisms confirm the prospects and the expediency of continuing the ongoing studies in medicine and biology.
- 29 October 2022
- Published by Russian Research Anti-Plague Institute Microbe in Problems of Particularly Dangerous Infections
- No. 3,p. 70-74
Open AccessExposure of Food Samples to Pulsed Microwave Radiation to Increase their Microbiological Safety and Shelf Life
The aim of the study was to increase the efficiency of decontamination of biological material and media (by the example of food products) by pulsed (non-thermal) radio emission and asses the prospects of its application in medicine and biology.Materials and methods. To achieve the goal an experimental setup has been designed, manufactured and tested, which makes it possible to study the process of exposure of biological materials and media to pulsed (non-thermal) radio emission, in particular, by the example of food products. The basis of the method is optimum control of the electro-physical parameters of the irradiating radio signal, depending on the type of the irradiated object. We used pulsed magnetrons with operating frequency of (2.45±0.05) GHz, authorized for bio-medical research, generating pulsed radiation with an adjustable power within the range of 0.1...10 kW. The pulse repetition rate with a duty cycle of 500...10000 is 0.1...5 kHz. The setup has an operating chamber into which the test sample is placed, as well as additional elements of magnetron protection and measuring the parameters of the microwave power incident on biological object.Results and discussion. The setup has been successfully used to irradiate various food samples with pathogenic micro flora (Salmonella spp. etc.) with pulsed microwave radiation. In particular, as shown by the studies, the arithmetic mean number of pathogenic bacteria in the irradiated samples of minced meat decreased by 27.5 times after 28 days of storage as compared to the control group of non-irradiated samples. Preliminary conducted experiments in the field of investigating the effect of microwave radiation on the process of cell division and other aspects of electromagnetic field influence on pathological microorganisms confirm the prospects and the expediency of continuing the ongoing studies in medicine and biology.
- 22 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 75-77
Reflection and Transmission Properties of a Rectangular Waveguide with Capacitive Post
The propagation and scattering characteristics of S/C-band standard rectangular waveguide WR187 with a metal capacitive post are investigated numerically by means of a 3-D finite element model. A preliminary testing of this model was carried out using experimental data taken from the literature. The occurrence of single transmission zeros in the frequency response was found for some values of the post height.
- 22 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 75-77
Reflection and Transmission Properties of a Rectangular Waveguide with Capacitive Post
The propagation and scattering characteristics of S/C-band standard rectangular waveguide WR187 with a metal capacitive post are investigated numerically by means of a 3-D finite element model. A preliminary testing of this model was carried out using experimental data taken from the literature. The occurrence of single transmission zeros in the frequency response was found for some values of the post height.
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (9) , 2845-2849
Experimental Study of Nano-Structural Coatings Formed by Microwave Plasma
A novel microwave plasma (MP) torch on a rectangular waveguide with two magnetron sources 2.45 GHz and an experimental setup are designed to perform hydroxyapatite (HA) coatings on metallic and dielectric substrates. Operating regimes of a such torch are investigated. Experimental studies have proved the advantages of this method of HA coating in comparison with analogous techniques. The proposed design is suitable for application in other technologies of different materials processing. Results obtained in the present study help to better understand the processes of nano-structural layer formation on solid substrates.
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (9) , 2845-2849
Experimental Study of Nano-Structural Coatings Formed by Microwave Plasma
A novel microwave plasma (MP) torch on a rectangular waveguide with two magnetron sources 2.45 GHz and an experimental setup are designed to perform hydroxyapatite (HA) coatings on metallic and dielectric substrates. Operating regimes of a such torch are investigated. Experimental studies have proved the advantages of this method of HA coating in comparison with analogous techniques. The proposed design is suitable for application in other technologies of different materials processing. Results obtained in the present study help to better understand the processes of nano-structural layer formation on solid substrates.
- 14 July 2022
- Published by Springer Nature in Journal of Computational Electronics
- Vol. 21 (5) , 1166-1173
Scattering characteristics of metal circular wire gratings in microwave and terahertz ranges
- 14 July 2022
- Published by Springer Nature in Journal of Computational Electronics
- Vol. 21 (5) , 1166-1173
Scattering characteristics of metal circular wire gratings in microwave and terahertz ranges
- Open Access
- 9 February 2022
- Published by Taylor & Francis in Journal of Electromagnetic Waves and Applications
- Vol. 36 (11) , 1604-1612
Extension of operating ranges of coaxial matched loads
The new coaxial matched load design with chip resistor and stepped transformer is described in this study. The proposed structure exhibits lower reflection and a wider range of operating frequencies than standard coaxial loads. Electromagnetic energy is absorbed in this design by a tantalum resistor on an Al2O3 substrate, which makes the manufacturing process simple and inexpensive. The reflection characteristics of the load under study were simulated numerically using a simplified model that included only the main parts of the load structure. Additional experimental studies made it possible to find the dimensions of the chip and other parts of the load design that provide improved electromagnetic characteristics.
- 9 February 2022
- Published by Taylor & Francis in Journal of Electromagnetic Waves and Applications
- Vol. 36 (11) , 1604-1612
Open AccessExtension of operating ranges of coaxial matched loads
The new coaxial matched load design with chip resistor and stepped transformer is described in this study. The proposed structure exhibits lower reflection and a wider range of operating frequencies than standard coaxial loads. Electromagnetic energy is absorbed in this design by a tantalum resistor on an Al2O3 substrate, which makes the manufacturing process simple and inexpensive. The reflection characteristics of the load under study were simulated numerically using a simplified model that included only the main parts of the load structure. Additional experimental studies made it possible to find the dimensions of the chip and other parts of the load design that provide improved electromagnetic characteristics.
- 1 February 2022
- Published by Pleiades Publishing Ltd in Technical Physics Letters
- Vol. 48 (2) , 19-22
An Atmospheric-Pressure Waveguide Microwave Plasmatron with Power Summing in the Plasma-Formation Zone
The design of an atmospheric-pressure plasmatron on a rectangular waveguide with a two-sided microwave energy supply to the interaction domain is considered. It is shown that the use of two magnetron sources makes it possible to obtain a stable discharge in the plasmatron, providing a continuous input of power into the gas flow. Results of studying the operating modes of the microwave plasmatron, which prove its advantages over analogs, are presented.
- 1 February 2022
- Published by Pleiades Publishing Ltd in Technical Physics Letters
- Vol. 48 (2) , 19-22
An Atmospheric-Pressure Waveguide Microwave Plasmatron with Power Summing in the Plasma-Formation Zone
The design of an atmospheric-pressure plasmatron on a rectangular waveguide with a two-sided microwave energy supply to the interaction domain is considered. It is shown that the use of two magnetron sources makes it possible to obtain a stable discharge in the plasmatron, providing a continuous input of power into the gas flow. Results of studying the operating modes of the microwave plasmatron, which prove its advantages over analogs, are presented.
- 1 February 2021
- Published by Pleiades Publishing Ltd in Journal of Communications Technology and Electronics
- Vol. 66 (2) , 136-139
Breakdown-Strength Enhancement of Coaxial-to-Waveguide Adapters
An improved structure of a high-power adapter is proposed for broadband matching of coaxial transmission lines and rectangular waveguides with a narrow side wall that are network used in space communication systems. Numerical simulation and optimization of such a microwave two-port are performed with the aid of the finite-element method in a frequency interval of 2.5–4.9 GHz. The sizes of a modified coaxial-to-waveguide adapter that provide the desired electrodynamic characteristics in the specified frequency interval are determined.
- 1 February 2021
- Published by Pleiades Publishing Ltd in Journal of Communications Technology and Electronics
- Vol. 66 (2) , 136-139
Breakdown-Strength Enhancement of Coaxial-to-Waveguide Adapters
An improved structure of a high-power adapter is proposed for broadband matching of coaxial transmission lines and rectangular waveguides with a narrow side wall that are network used in space communication systems. Numerical simulation and optimization of such a microwave two-port are performed with the aid of the finite-element method in a frequency interval of 2.5–4.9 GHz. The sizes of a modified coaxial-to-waveguide adapter that provide the desired electrodynamic characteristics in the specified frequency interval are determined.
- 1 January 2021
- Published by Ioffe Institute Russian Academy of Sciences in Письма в журнал технической физики
- Vol. 47 (18) , 36
Волноводный СВЧ-плазмотрон атмосферного давления с суммированием мощности в зоне формирования плазмы
The design of an atmospheric pressure plasmatron on a rectangular waveguide with a two-sided microwave energy supply to the interaction domain is considered. It is shown that the use of two magnetron sources makes it possible to obtain a stable discharge in the plasmatron, providing a continuous input of power into the gas flow. The results of studies of the operating modes of the microwave plasmatron, which prove its advantages over analogs, are presented.
- 1 January 2021
- Published by Ioffe Institute Russian Academy of Sciences in Письма в журнал технической физики
- Vol. 47 (18) , 36
Волноводный СВЧ-плазмотрон атмосферного давления с суммированием мощности в зоне формирования плазмы
The design of an atmospheric pressure plasmatron on a rectangular waveguide with a two-sided microwave energy supply to the interaction domain is considered. It is shown that the use of two magnetron sources makes it possible to obtain a stable discharge in the plasmatron, providing a continuous input of power into the gas flow. The results of studies of the operating modes of the microwave plasmatron, which prove its advantages over analogs, are presented.