Kurosh Darvish
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kurosh Darvish has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
Kaveh Laksari
Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA
17 shared publicationsSoroush Assari
16 shared publications- Mehdi Shafieian
Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
14 shared publications Mobin Rastgar Agah
Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA
7 shared publicationsAli Hemmasizadeh
Department of Mechanical Engineering, College of Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, United States
6 shared publicationsMichael Autieri
Department of Physiology, School of Medicine, Temple University, 3500 N. Broad Street, Philadelphia, PA 19140, United States
5 shared publications
Latest Publications
- Open Access
- 1 July 2018
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 3 (3)
Plantar Plate Reconstruction for Stage IV Plantar Plate Tear Using Flexor Tendon Tenodesis
Category: Lesser Toes Introduction/Purpose: Outcomes of the surgical treatment of dislocated lesser toes have improved significantly over the past few years due to the development of techniques to repair plantar plate tears through a dorsal incision. However, treatment of stage 4 tears with no reparable plantar plate can be challenging. The current treatment involves flexor to extensor tendon transfer, requiring multiple incisions and surgical time. An alternative approach is presented, using the same modern techniques of plantar plate repair, but reconstructing the plantar plate using a flexor tendon tenodesis to the plantar base of the proximal phalanx. Methods: Four fresh frozen cadaver foot and ankle specimens were used to determine the stability of this new technique. A simulated Lachman’s test was performed on the 2nd, 3 rd, and 4th metatarsophalangeal joints utilizing a force measurement instrument with displacement control on specimens with an intact plantar plate, an excised plantar plate, and following a flexor tenodesis reconstruction. Results: The intact plantar plate force was 9.0+2.6kN for 2 mm displacement, and following excision of the plantar plate, the force reduced to 1.3+0.4kN. The flexor tenodesis reconstruction improved the force to 6.0+1.9kN. Conclusion: Plantar plate reconstruction with a flexor tenodesis to the proximal phalanx resulted in stability equal to 53% of the intact plantar plate, for the shear displacements between 2 to 6 mm. This procedure may be an alternative treatment option in patients with Stage 4 irreparable plantar plate tears.
- 1 July 2018
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 3 (3)
Open AccessPlantar Plate Reconstruction for Stage IV Plantar Plate Tear Using Flexor Tendon Tenodesis
Category: Lesser Toes Introduction/Purpose: Outcomes of the surgical treatment of dislocated lesser toes have improved significantly over the past few years due to the development of techniques to repair plantar plate tears through a dorsal incision. However, treatment of stage 4 tears with no reparable plantar plate can be challenging. The current treatment involves flexor to extensor tendon transfer, requiring multiple incisions and surgical time. An alternative approach is presented, using the same modern techniques of plantar plate repair, but reconstructing the plantar plate using a flexor tendon tenodesis to the plantar base of the proximal phalanx. Methods: Four fresh frozen cadaver foot and ankle specimens were used to determine the stability of this new technique. A simulated Lachman’s test was performed on the 2nd, 3 rd, and 4th metatarsophalangeal joints utilizing a force measurement instrument with displacement control on specimens with an intact plantar plate, an excised plantar plate, and following a flexor tenodesis reconstruction. Results: The intact plantar plate force was 9.0+2.6kN for 2 mm displacement, and following excision of the plantar plate, the force reduced to 1.3+0.4kN. The flexor tenodesis reconstruction improved the force to 6.0+1.9kN. Conclusion: Plantar plate reconstruction with a flexor tenodesis to the proximal phalanx resulted in stability equal to 53% of the intact plantar plate, for the shear displacements between 2 to 6 mm. This procedure may be an alternative treatment option in patients with Stage 4 irreparable plantar plate tears.
- 1 June 2017
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 32 (6) , 2017-2022
Broach Handle Design Changes Force Distribution in the Femur During Total Hip Arthroplasty
- 1 June 2017
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 32 (6) , 2017-2022
Broach Handle Design Changes Force Distribution in the Femur During Total Hip Arthroplasty
- 23 March 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 231 (4) , 326-336
Mechanical behavior of porcine thoracic aorta in physiological and supra-physiological intraluminal pressures
Understanding the mechanical behavior of aorta under supra-physiological loadings is an important aspect of modeling tissue behavior in various applications that involve large deformations. Utilizing inflation–extension experiments, the mechanical behavior of porcine descending thoracic aortic segments under physiological and supra-physiological intraluminal pressures was investigated. The pressure was changed in the range of 0–70 kPa and the deformation of the segment was determined in three dimensions using a custom-made motion capture system. An orthotropic Fung-type constitutive model was characterized by implementing a novel computationally efficient framework that ensured material stability for numerical simulations. The nonlinear rising trend of circumferential stretch ratio from outer toward inner wall was significantly increased at higher pressures. The increase in from physiological pressure (13 kPa) to 70 kPa was 13% at the outer wall and 22% at the inner wall; in this pressure range, the longitudinal stretch ratio increased 20%. A significant nonlinearity in the material behavior was observed as in the same pressure range, and the circumferential and longitudinal Cauchy stresses at the inner wall were increased 16 and 18 times, respectively. The overall constitutive model was verified in several loading paths in the space to confirm its applicability in multi-axial loading conditions.- 23 March 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 231 (4) , 326-336
Mechanical behavior of porcine thoracic aorta in physiological and supra-physiological intraluminal pressures
Understanding the mechanical behavior of aorta under supra-physiological loadings is an important aspect of modeling tissue behavior in various applications that involve large deformations. Utilizing inflation–extension experiments, the mechanical behavior of porcine descending thoracic aortic segments under physiological and supra-physiological intraluminal pressures was investigated. The pressure was changed in the range of 0–70 kPa and the deformation of the segment was determined in three dimensions using a custom-made motion capture system. An orthotropic Fung-type constitutive model was characterized by implementing a novel computationally efficient framework that ensured material stability for numerical simulations. The nonlinear rising trend of circumferential stretch ratio from outer toward inner wall was significantly increased at higher pressures. The increase in from physiological pressure (13 kPa) to 70 kPa was 13% at the outer wall and 22% at the inner wall; in this pressure range, the longitudinal stretch ratio increased 20%. A significant nonlinearity in the material behavior was observed as in the same pressure range, and the circumferential and longitudinal Cauchy stresses at the inner wall were increased 16 and 18 times, respectively. The overall constitutive model was verified in several loading paths in the space to confirm its applicability in multi-axial loading conditions.- 1 February 2017
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 42 (2) , 87-95
Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study
- 1 February 2017
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 42 (2) , 87-95
Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study
- 18 July 2016
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 31 (4) , 861-872
Simulation and experimental studies in needle–tissue interactions
This work aims to introduce a new needle insertion simulation to predict the deflection of a bevel-tip needle inside soft tissue. The development of such a model, which predicts the steering behavior of the needle during needle-tissue interactions, could improve the performance of many percutaneous needle-based procedures such as brachytherapy and thermal ablation, by means of the virtual path planning and training systems of the needle toward the target and thus reducing possible incidents of complications in clinical practices. The Arbitrary–Lagrangian–Eulerian (ALE) formulation in LS-DYNA software was used to model the solid–fluid interactions between the needle and tissue. Since both large deformation and fracture of the continuum need to be considered in this model, applying ALE method for fluid analysis was considered a suitable approach. A 150 mm long needle was used to bend within the tissue due to the interacting forces on its asymmetric bevel tip. Three experimental cases of needle steering in a soft phantom were performed to validate the simulation. An error measurement of less than 10 % was found between the predicted deflection by the simulations and the one observed in experiments, validating our approach with reasonable accuracy. The effect of the needle diameter and its bevel tip angle on the final shape of the needle was investigated using this model. To maneuver around the anatomical obstacles of the human body and reach the target location, thin sharp needles are recommended, as they would create a smaller radius of curvature. The insertion model presented in this work is intended to be used as a base structure for path planning and training purposes for future studies.
- 18 July 2016
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 31 (4) , 861-872
Simulation and experimental studies in needle–tissue interactions
This work aims to introduce a new needle insertion simulation to predict the deflection of a bevel-tip needle inside soft tissue. The development of such a model, which predicts the steering behavior of the needle during needle-tissue interactions, could improve the performance of many percutaneous needle-based procedures such as brachytherapy and thermal ablation, by means of the virtual path planning and training systems of the needle toward the target and thus reducing possible incidents of complications in clinical practices. The Arbitrary–Lagrangian–Eulerian (ALE) formulation in LS-DYNA software was used to model the solid–fluid interactions between the needle and tissue. Since both large deformation and fracture of the continuum need to be considered in this model, applying ALE method for fluid analysis was considered a suitable approach. A 150 mm long needle was used to bend within the tissue due to the interacting forces on its asymmetric bevel tip. Three experimental cases of needle steering in a soft phantom were performed to validate the simulation. An error measurement of less than 10 % was found between the predicted deflection by the simulations and the one observed in experiments, validating our approach with reasonable accuracy. The effect of the needle diameter and its bevel tip angle on the final shape of the needle was investigated using this model. To maneuver around the anatomical obstacles of the human body and reach the target location, thin sharp needles are recommended, as they would create a smaller radius of curvature. The insertion model presented in this work is intended to be used as a base structure for path planning and training purposes for future studies.
- 1 July 2016
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 134 (7) , 763-9
Association of Football Subconcussive Head Impacts With Ocular Near Point of Convergence
Research from JAMA Ophthalmology — Association of Football Subconcussive Head Impacts With Ocular Near Point of Convergence
- 1 July 2016
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 134 (7) , 763-9
Association of Football Subconcussive Head Impacts With Ocular Near Point of Convergence
Research from JAMA Ophthalmology — Association of Football Subconcussive Head Impacts With Ocular Near Point of Convergence
- 1 February 2016
- Published by World Scientific Pub Co Pte Ltd in International Journal of Applied Mechanics
- Vol. 08 (01)
Mechanical Instability of Aorta due to Intraluminal Pressure
- 1 February 2016
- Published by World Scientific Pub Co Pte Ltd in International Journal of Applied Mechanics
- Vol. 08 (01)
Mechanical Instability of Aorta due to Intraluminal Pressure
- 1 November 2015
- Published by Elsevier in Clinical Biomechanics
- Vol. 30 (9) , 966-970
Comparison of crossed screw versus plate fixation for radial neck fractures
- 1 November 2015
- Published by Elsevier in Clinical Biomechanics
- Vol. 30 (9) , 966-970
Comparison of crossed screw versus plate fixation for radial neck fractures