Franklin N. Tessler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Franklin N. Tessler has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
William D. Middleton
Department of Radiology, Washington University School of Medicine, St. Louis, Missouri
10 shared publicationsEdward G. Grant
Department of Radiology, Keck School of Medicine, Los Angeles, California
7 shared publicationsJenny K. Hoang
Department of Radiology and Radiological Science, Johns Hopkins School of Medicine, Baltimore, Maryland, USA
7 shared publications- Jenny K. Hoang
Duke University Medical Center, Durham, North Carolina
5 shared publications - Benjamin Wildman-Tobriner
Department of Radiology, Duke University School of Medicine, Durham, NC
2 shared publications - Cosimo Durante
Department of Translational and Precision Medicine, Sapienza University of Rome, 00185 Rome, Italy
2 shared publications
Latest Publications
- Top Cited Papers
- 1 October 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 309 (1) , e231481
International Expert Consensus on US Lexicon for Thyroid Nodules
Multiple US-based systems for risk stratification of thyroid nodules are in use worldwide. Unfortunately, the malignancy probability assigned to a nodule varies, and terms and definitions are not consistent, leading to confusion and making it challenging to compare study results and craft revisions. Consistent application of these systems is further hampered by interobserver variability in identifying the sonographic features on which they are founded. In 2018, an international multidisciplinary group of 19 physicians with expertise in thyroid sonography (termed the International Thyroid Nodule Ultrasound Working Group) was convened with the goal of developing an international system, tentatively called the International Thyroid Imaging Reporting and Data System, or I-TIRADS, in two phases: (phase I) creation of a lexicon and atlas of US descriptors of thyroid nodules and (phase II) development of a system that estimates the malignancy risk of a thyroid nodule. This article presents the methods and results of phase I. The purpose herein is to show what has been accomplished thus far, as well as generate interest in and support for this effort in the global thyroid community.
- 1 October 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 309 (1) , e231481
Top Cited PapersInternational Expert Consensus on US Lexicon for Thyroid Nodules
Multiple US-based systems for risk stratification of thyroid nodules are in use worldwide. Unfortunately, the malignancy probability assigned to a nodule varies, and terms and definitions are not consistent, leading to confusion and making it challenging to compare study results and craft revisions. Consistent application of these systems is further hampered by interobserver variability in identifying the sonographic features on which they are founded. In 2018, an international multidisciplinary group of 19 physicians with expertise in thyroid sonography (termed the International Thyroid Nodule Ultrasound Working Group) was convened with the goal of developing an international system, tentatively called the International Thyroid Imaging Reporting and Data System, or I-TIRADS, in two phases: (phase I) creation of a lexicon and atlas of US descriptors of thyroid nodules and (phase II) development of a system that estimates the malignancy risk of a thyroid nodule. This article presents the methods and results of phase I. The purpose herein is to show what has been accomplished thus far, as well as generate interest in and support for this effort in the global thyroid community.
- 1 June 2022
- Published by SAGE Publications in Thyroid®
- Vol. 32 (6) , 675-681
An International Survey on Utilization of Five Thyroid Nodule Risk Stratification Systems: A Needs Assessment with Future Implications
Background: Multiple ultrasound-based risk stratification systems (RSSs) for thyroid nodules are used worldwide. Variations in structure, performance, and recommendations are confusing for physicians and patients and complicate management decisions. The goal of this study was to determine the factors that are associated with choice of RSS and barriers to RSS use. These results are intended to inform development of a universal international thyroid ultrasound RSS. Methods: An online survey with questions about usage of RSSs, ultrasound practice and volumes, training, specialty, practice type, and geographic region was made available to members of five professional societies via email. Subgroup analysis was performed to identify the factors that governed use of one or more of five leading RSSs: American Association of Clinical Endocrinology (AACE), American College of Endocrinology (ACE), and Associazione Medici Endocrinologi (AME) Medical Guidelines, American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (ACR TI-RADS), American Thyroid Association (ATA) Guidelines, European Thyroid Association TIRADS (EU-TIRADS), and Korean Society of Thyroid Radiology/Korean Thyroid Association TIRADS (K-TIRADS). Results: There were 875 respondents from 52 countries (response rate not estimated due to overlapping society membership). More than seven specialties were represented, with most (538; 61.5%) in endocrinology. The choice of RSS was strongly associated with medical specialty and geographic region. Out of 692 respondents who indicated that their practice used an RSS, 213 (30.8%) used more than one. The specialties that were more likely to use multiple RSSs were surgery and others (40%), followed by endocrinology (33.0%), and radiology or nuclear medicine (17%) (p <0.001). Out of 271 (31.0%) respondents who indicated that they do not personally use an RSS, the majority (168; 62%) preferred to describe the specific sonographic characteristics/features that they believe are most relevant in a nodule. Conclusions: Almost one-third of respondents indicated use of more than one RSS in practice, potentially leading to confusion, and a similar proportion reported not using a RSS for various reasons. A unified international system that addresses their concerns and simplifies risk classification of thyroid nodules may benefit practitioners and patients. This is particularly important as newer thyroid management options gain acceptance.
- 1 June 2022
- Published by SAGE Publications in Thyroid®
- Vol. 32 (6) , 675-681
An International Survey on Utilization of Five Thyroid Nodule Risk Stratification Systems: A Needs Assessment with Future Implications
Background: Multiple ultrasound-based risk stratification systems (RSSs) for thyroid nodules are used worldwide. Variations in structure, performance, and recommendations are confusing for physicians and patients and complicate management decisions. The goal of this study was to determine the factors that are associated with choice of RSS and barriers to RSS use. These results are intended to inform development of a universal international thyroid ultrasound RSS. Methods: An online survey with questions about usage of RSSs, ultrasound practice and volumes, training, specialty, practice type, and geographic region was made available to members of five professional societies via email. Subgroup analysis was performed to identify the factors that governed use of one or more of five leading RSSs: American Association of Clinical Endocrinology (AACE), American College of Endocrinology (ACE), and Associazione Medici Endocrinologi (AME) Medical Guidelines, American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (ACR TI-RADS), American Thyroid Association (ATA) Guidelines, European Thyroid Association TIRADS (EU-TIRADS), and Korean Society of Thyroid Radiology/Korean Thyroid Association TIRADS (K-TIRADS). Results: There were 875 respondents from 52 countries (response rate not estimated due to overlapping society membership). More than seven specialties were represented, with most (538; 61.5%) in endocrinology. The choice of RSS was strongly associated with medical specialty and geographic region. Out of 692 respondents who indicated that their practice used an RSS, 213 (30.8%) used more than one. The specialties that were more likely to use multiple RSSs were surgery and others (40%), followed by endocrinology (33.0%), and radiology or nuclear medicine (17%) (p <0.001). Out of 271 (31.0%) respondents who indicated that they do not personally use an RSS, the majority (168; 62%) preferred to describe the specific sonographic characteristics/features that they believe are most relevant in a nodule. Conclusions: Almost one-third of respondents indicated use of more than one RSS in practice, potentially leading to confusion, and a similar proportion reported not using a RSS for various reasons. A unified international system that addresses their concerns and simplifies risk classification of thyroid nodules may benefit practitioners and patients. This is particularly important as newer thyroid management options gain acceptance.
- 12 November 2019
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 48 (1) , 7-8
Re: ACR TI‐RADS: An advance in the management of thyroid nodules or Pandora's box of surveillance?
- 12 November 2019
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 48 (1) , 7-8
Re: ACR TI‐RADS: An advance in the management of thyroid nodules or Pandora's box of surveillance?
- Top Cited Papers
- 1 September 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 292 (3) , 695-701
Management of Thyroid Nodules Seen on US Images: Deep Learning May Match Performance of Radiologists
A deep convolutional neural network that uses American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) features for training achieves similar sensitivity and specific... BackgroundManagement of thyroid nodules may be inconsistent between different observers and time consuming for radiologists. An artificial intelligence system that uses deep learning may improve ra...
- 1 September 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 292 (3) , 695-701
Top Cited PapersManagement of Thyroid Nodules Seen on US Images: Deep Learning May Match Performance of Radiologists
A deep convolutional neural network that uses American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) features for training achieves similar sensitivity and specific... BackgroundManagement of thyroid nodules may be inconsistent between different observers and time consuming for radiologists. An artificial intelligence system that uses deep learning may improve ra...
- 1 July 2019
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 39 (4) , 1017-1018
Recognizing and Minimizing Artifacts at CT, MRI, US, and Molecular Imaging
Understanding the physical principles and technical assumptions that underlie image production can help radiologists eliminate or minimize common imaging artifacts and improve diagnostic accuracy.
- 1 July 2019
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 39 (4) , 1017-1018
Recognizing and Minimizing Artifacts at CT, MRI, US, and Molecular Imaging
Understanding the physical principles and technical assumptions that underlie image production can help radiologists eliminate or minimize common imaging artifacts and improve diagnostic accuracy.
- 1 July 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 292 (1) , 112-119
Using Artificial Intelligence to Revise ACR TI-RADS Risk Stratification of Thyroid Nodules: Diagnostic Accuracy and Utility
Artificial intelligence modeling suggests that the American College of Radiology Thyroid Imaging Reporting and Data System may be modified to improve ease of use while also improving specificity. BackgroundRisk stratification systems for thyroid nodules are often complicated and affected by low specificity. Continual improvement of these systems is necessary to reduce the number of unnecess...
- 1 July 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 292 (1) , 112-119
Using Artificial Intelligence to Revise ACR TI-RADS Risk Stratification of Thyroid Nodules: Diagnostic Accuracy and Utility
Artificial intelligence modeling suggests that the American College of Radiology Thyroid Imaging Reporting and Data System may be modified to improve ease of use while also improving specificity. BackgroundRisk stratification systems for thyroid nodules are often complicated and affected by low specificity. Continual improvement of these systems is necessary to reduce the number of unnecess...
- 1 May 2019
- Published by Elsevier in Endocrine Practice
- Vol. 25 (5) , 503-505
Commentary on a Direct Comparison of the Ata and Ti-Rads Ultrasound Scoring Systems
- 1 May 2019
- Published by Elsevier in Endocrine Practice
- Vol. 25 (5) , 503-505
Commentary on a Direct Comparison of the Ata and Ti-Rads Ultrasound Scoring Systems
- 1 August 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 288 (2) , 635
Guidelines for Biopsy of Thyroid Nodules
- 1 August 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 288 (2) , 635
Guidelines for Biopsy of Thyroid Nodules
- Top Cited Papers
- 1 April 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 287 (1) , 29-36
Thyroid Imaging Reporting and Data System (TI-RADS): A User’s Guide
The purpose of this article is to present our perspective and provide practical advice to ultrasonography practitioners who adopt the American College of Radiology Thyroid Imaging Reporting and Data System. In 2017, the Thyroid Imaging Reporting and Data System (TI-RADS) Committee of the American College of Radiology (ACR) published a white paper that presented a new risk-stratification system for classifying thyroid nodules on the basis of their appearance at ultrasonography (US). In ACR TI-RADS, points in five feature categories are summed to determine a risk level from TR1 to TR5. Recommendations for biopsy or US follow-up are based on the nodule’s ACR TI-RADS level and its maximum diameter. The purpose of this article is to offer practical guidance on how to implement and apply ACR TI-RADS based on the authors’ experience with the system.© RSNA, 2018
- 1 April 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 287 (1) , 29-36
Top Cited PapersThyroid Imaging Reporting and Data System (TI-RADS): A User’s Guide
The purpose of this article is to present our perspective and provide practical advice to ultrasonography practitioners who adopt the American College of Radiology Thyroid Imaging Reporting and Data System. In 2017, the Thyroid Imaging Reporting and Data System (TI-RADS) Committee of the American College of Radiology (ACR) published a white paper that presented a new risk-stratification system for classifying thyroid nodules on the basis of their appearance at ultrasonography (US). In ACR TI-RADS, points in five feature categories are summed to determine a risk level from TR1 to TR5. Recommendations for biopsy or US follow-up are based on the nodule’s ACR TI-RADS level and its maximum diameter. The purpose of this article is to offer practical guidance on how to implement and apply ACR TI-RADS based on the authors’ experience with the system.© RSNA, 2018