Kostadin Kostadinov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kostadin Kostadinov has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- T. Tiankov
Institute of Mechanics, Bulgarian Academy of Sciences, Sofia, Bulgaria
6 shared publications D. Chakarov
Institute of Mechanics, Bulgarian Academy of Sciences, Sofia, Bulgaria
5 shared publications- Vladimir Kotev
Mathematics, University of National and World Economy
3 shared publications A. Shulev
Institute of Mechanics, Bulgarian Academy of Sciences, Sofia, Bulgaria
2 shared publicationsAssen Shulev
Institute of Mechanics, Bulgarian Academy of Sciences, Sofia, Bulgaria
2 shared publicationsDaniel Dantchev
Institute of Mechanics, Bulgarian Academy of Sciences, Bulgaria
2 shared publications
Latest Publications
- 2 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 296-300
Registration approach of viruses by using the electromagnetic echo effect
Early identification of viruses is extremely important for efficient disease management and control. A new approach for creating virus sensors based on the Electromagnetic echo effect (EMEE) is proposed. An important feature is that the signal from EMEE is highly dependent on the state of the studied sample. This makes it possible to control ongoing reactions, even if they are invisible to the human eye or other equipment. We demonstrate the applicability of the approach for registering a reaction occurring in the presence of an avian coronavirus that causes infectious bronchitis, strain Massachusetts. The same approach can be effectively utilized for quick detection of the presence of other types of viruses as well bio samples, thus enabling reliable control of their spreading in the environment or patient diagnosis.
- 2 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 296-300
Registration approach of viruses by using the electromagnetic echo effect
Early identification of viruses is extremely important for efficient disease management and control. A new approach for creating virus sensors based on the Electromagnetic echo effect (EMEE) is proposed. An important feature is that the signal from EMEE is highly dependent on the state of the studied sample. This makes it possible to control ongoing reactions, even if they are invisible to the human eye or other equipment. We demonstrate the applicability of the approach for registering a reaction occurring in the presence of an avian coronavirus that causes infectious bronchitis, strain Massachusetts. The same approach can be effectively utilized for quick detection of the presence of other types of viruses as well bio samples, thus enabling reliable control of their spreading in the environment or patient diagnosis.
- 30 January 2021
- Published by Prof. Marin Drinov Publishing House of BAS (Bulgarian Academy of Sciences)
- Vol. 74 (1) , 145-154
Analysis of the Antioxidant Capacity of Lettuce Growth at Different Fertilizer Regimes
- 30 January 2021
- Published by Prof. Marin Drinov Publishing House of BAS (Bulgarian Academy of Sciences)
- Vol. 74 (1) , 145-154
Analysis of the Antioxidant Capacity of Lettuce Growth at Different Fertilizer Regimes
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 350-353
Formation of Nanosized Needle Structures in Ultra-Thin Organic Film for Biosensor Application
Biosensors are a promising field driven by research and industry needs. Large number of applications require highly selective and sensitive fast acting biosensors. We target water quality monitoring, cancer research and drug discovery applications. In the biosensor development crucial is the active bioreceptor layer which interacts with the analyte. Here we propose ultra-thin organic films prepared by the Langmuir-Blodgett method from a fluorescently labelled phospholipid. The average thickness of the layer is 3 nm suggesting fast reaction times. From this layer protrude stable over time around 10 nm high spikes with diameters typically from 50 to 300 nm. Thus a well-developed 3D structure is achieved which should yield increased sensor sensitivity for advanced chemical sensor applications.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 350-353
Formation of Nanosized Needle Structures in Ultra-Thin Organic Film for Biosensor Application
Biosensors are a promising field driven by research and industry needs. Large number of applications require highly selective and sensitive fast acting biosensors. We target water quality monitoring, cancer research and drug discovery applications. In the biosensor development crucial is the active bioreceptor layer which interacts with the analyte. Here we propose ultra-thin organic films prepared by the Langmuir-Blodgett method from a fluorescently labelled phospholipid. The average thickness of the layer is 3 nm suggesting fast reaction times. From this layer protrude stable over time around 10 nm high spikes with diameters typically from 50 to 300 nm. Thus a well-developed 3D structure is achieved which should yield increased sensor sensitivity for advanced chemical sensor applications.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 19-25
CARS detection with diode lasers in digital holographic microscopy
The subject of this paper is coherent anti-Stokes Raman scattering (CARS) detection of different groups at molecular level in cells with low-energy CW diode lasers in parallel and simultaneously with holographic recording. This is essential for the non-invasive 3D reconstruction and markers free labeling of biological objects. A laboratory version of the diode lasers microscopic system with attachment for spectral detection is presented. Experimental results for parallel holographic recording of fixed cells and detection of CARS signals from different groups at molecular level, including - (S-H), (C-H) and (=(CH)) are obtained. They shows an advantage of the used phase-stepping algorithm (PSA) over a Fast Fourier Transform (FFT) algorithm for phase retrieval. The sensitivity of the CARS detection with diode lasers is estimated and compared for the same objects with a standard Raman micro spectrometer. The developed system is compact, suitable to perform measurement in real-time operation mode, and promising for markers free labeling of holographical reconstructed 3D images of the cells with parallel recorded 2D pictures of the CARS signals.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 19-25
CARS detection with diode lasers in digital holographic microscopy
The subject of this paper is coherent anti-Stokes Raman scattering (CARS) detection of different groups at molecular level in cells with low-energy CW diode lasers in parallel and simultaneously with holographic recording. This is essential for the non-invasive 3D reconstruction and markers free labeling of biological objects. A laboratory version of the diode lasers microscopic system with attachment for spectral detection is presented. Experimental results for parallel holographic recording of fixed cells and detection of CARS signals from different groups at molecular level, including - (S-H), (C-H) and (=(CH)) are obtained. They shows an advantage of the used phase-stepping algorithm (PSA) over a Fast Fourier Transform (FFT) algorithm for phase retrieval. The sensitivity of the CARS detection with diode lasers is estimated and compared for the same objects with a standard Raman micro spectrometer. The developed system is compact, suitable to perform measurement in real-time operation mode, and promising for markers free labeling of holographical reconstructed 3D images of the cells with parallel recorded 2D pictures of the CARS signals.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1-5
A smart LIDAR based on compact Nd:YAG laser for atmospheric fine particulate matter
A Smart LIDAR system based on an innovative Nd:YAG laser designed for operation at three wavelengths (1064 nm, 532 nm and 355 nm) is presented. The repetition rate of the emitting module of up to 4 kHz allows for the basic version of the described system to achieve a spatial resolution of 187.5 cm. The system is a smart mobile device/unit ideally suited for: (i) studies of time-vertical variation of atmospheric fine particulate matter, (ii) 3D reconstruction of plumes from stationary and mobile sources, e.g., emitted by industrial stacks of industrial plants, ships, airplanes, vehicles, etc. Preliminary results with the proposed systems operating at 532 nm and 355 nm are reported here.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1-5
A smart LIDAR based on compact Nd:YAG laser for atmospheric fine particulate matter
A Smart LIDAR system based on an innovative Nd:YAG laser designed for operation at three wavelengths (1064 nm, 532 nm and 355 nm) is presented. The repetition rate of the emitting module of up to 4 kHz allows for the basic version of the described system to achieve a spatial resolution of 187.5 cm. The system is a smart mobile device/unit ideally suited for: (i) studies of time-vertical variation of atmospheric fine particulate matter, (ii) 3D reconstruction of plumes from stationary and mobile sources, e.g., emitted by industrial stacks of industrial plants, ships, airplanes, vehicles, etc. Preliminary results with the proposed systems operating at 532 nm and 355 nm are reported here.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 136-140
Model-based design optimization of soft fiber-reinforced bending actuators
In this paper we present an analytical model for soft fiber-reinforced bending actuators consisting of a single air chamber made of elastomeric material and reinforced with an inextensible fiber winding. The model explicitly links the input pressure applied to the actuator to the resulting bending angle in free space and to the contact force when the actuator tip is in contact with an external rigid obstacle. The model predictions are compared to available experimental data for hemi-circular actuator with uniform wall thicknesses. The validated model is then used for design optimization of actuator's wall thicknesses which represent key geometric parameters. The model predicts that for a fixed air chamber radius, actuator with optimized wall thicknesses requires about 48 % lower input pressure to achieve a prescribed bending angle compared to non-optimized actuator with uniform wall thicknesses. In addition, the optimized actuator generates about 18 % stronger contact force between the distal tip and a rigid obstacle compared to the contact force generated by actuator with uniform wall thicknesses.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 136-140
Model-based design optimization of soft fiber-reinforced bending actuators
In this paper we present an analytical model for soft fiber-reinforced bending actuators consisting of a single air chamber made of elastomeric material and reinforced with an inextensible fiber winding. The model explicitly links the input pressure applied to the actuator to the resulting bending angle in free space and to the contact force when the actuator tip is in contact with an external rigid obstacle. The model predictions are compared to available experimental data for hemi-circular actuator with uniform wall thicknesses. The validated model is then used for design optimization of actuator's wall thicknesses which represent key geometric parameters. The model predicts that for a fixed air chamber radius, actuator with optimized wall thicknesses requires about 48 % lower input pressure to achieve a prescribed bending angle compared to non-optimized actuator with uniform wall thicknesses. In addition, the optimized actuator generates about 18 % stronger contact force between the distal tip and a rigid obstacle compared to the contact force generated by actuator with uniform wall thicknesses.
- 19 April 2016
- Published by Taylor & Francis
- p. 385-408
Impedance-Controlled Mechatronic Systems for Autonomous Intelligent Devices
- 19 April 2016
- Published by Taylor & Francis
- p. 385-408
Impedance-Controlled Mechatronic Systems for Autonomous Intelligent Devices
- 26 February 2014
- Published by IGI Global Scientific Publishing
- p. 612-628
On the Forces between Micro and Nano Objects and a Gripper
The authors study the van der Waals force FvdW, between the gripper jaw and an object – cubical, spherical and conical in shape, situated at a distance L of closest approach from it. The generic and most general case is considered, when the materials of the working jaw of the gripper and the particle are made of different materials strongly preferring the liquid phase of the fluid being at temperature T and chemical potentialm. The contributions due to the standard van der Waals, as well as of the retarded (Casimir) van der Waals interactions are considered. They concluded that FvdW strongly depends on the contrast, at given fixed T and m, between the physical properties of the fluid and the material of the arms of the gripper and the particle. In addition, as expected, FvdW strongly depends on the shape of the object, its size, and the distance L between it and the working jaw of the gripper. Their approach can be applied to any nonpolar fluid.
- 26 February 2014
- Published by IGI Global Scientific Publishing
- p. 612-628
On the Forces between Micro and Nano Objects and a Gripper
The authors study the van der Waals force FvdW, between the gripper jaw and an object – cubical, spherical and conical in shape, situated at a distance L of closest approach from it. The generic and most general case is considered, when the materials of the working jaw of the gripper and the particle are made of different materials strongly preferring the liquid phase of the fluid being at temperature T and chemical potentialm. The contributions due to the standard van der Waals, as well as of the retarded (Casimir) van der Waals interactions are considered. They concluded that FvdW strongly depends on the contrast, at given fixed T and m, between the physical properties of the fluid and the material of the arms of the gripper and the particle. In addition, as expected, FvdW strongly depends on the shape of the object, its size, and the distance L between it and the working jaw of the gripper. Their approach can be applied to any nonpolar fluid.
- 1 July 2013
- Published by IGI Global Scientific Publishing in International Journal of Intelligent Mechatronics and Robotics
- Vol. 3 (3) , 77-98
A Robot for Cell Injection
This work deals with modelling and experimenting of a compliant serial-parallel robot. Using Pseudo-Rigid-Body Modelling (PRBM) of elastic structures, a kinematics and stiffness model of a serial-parallel structure has been built. Several approaches for pre-tensioning of a parallel structure with elastic joints were developed in order to eliminate backlashes and improve the performance of its actuators. In this work a robot is designed to inject biological cells with size in the range of 10-30µm. The approaches used for pre-tensioning of the robot have been analysed and subjected to numerical evaluation. Assessing the mechanical parameters of the tensed manipulator has been performed using the following methods: PRBM and Finite Element Analysis (FEA). An experimental set-up for testing a robot prototype has been developed, using an optical system and correlation technique for digital image processing. The experimental results obtained are compared to data received from the numerical experiment.
- 1 July 2013
- Published by IGI Global Scientific Publishing in International Journal of Intelligent Mechatronics and Robotics
- Vol. 3 (3) , 77-98
A Robot for Cell Injection
This work deals with modelling and experimenting of a compliant serial-parallel robot. Using Pseudo-Rigid-Body Modelling (PRBM) of elastic structures, a kinematics and stiffness model of a serial-parallel structure has been built. Several approaches for pre-tensioning of a parallel structure with elastic joints were developed in order to eliminate backlashes and improve the performance of its actuators. In this work a robot is designed to inject biological cells with size in the range of 10-30µm. The approaches used for pre-tensioning of the robot have been analysed and subjected to numerical evaluation. Assessing the mechanical parameters of the tensed manipulator has been performed using the following methods: PRBM and Finite Element Analysis (FEA). An experimental set-up for testing a robot prototype has been developed, using an optical system and correlation technique for digital image processing. The experimental results obtained are compared to data received from the numerical experiment.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 335-338
Force sensor for cell injection and characterization
This paper presents the basics idea and principles of a force sensor for cell injection and characterization of mechanical properties of cells. It utilizes fluidics, piezo resistive MEMS, and piezo actuated mechanics to provide sub-micronewton sensitivity in vertical injection mode. The prototyping, calibration and investigation of the proposed sensor are also presented in brief. Main advantages and drawbacks are also discussed.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 335-338
Force sensor for cell injection and characterization
This paper presents the basics idea and principles of a force sensor for cell injection and characterization of mechanical properties of cells. It utilizes fluidics, piezo resistive MEMS, and piezo actuated mechanics to provide sub-micronewton sensitivity in vertical injection mode. The prototyping, calibration and investigation of the proposed sensor are also presented in brief. Main advantages and drawbacks are also discussed.