Alejandro A. Espinoza Orias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alejandro A. Espinoza Orias has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Nozomu Inoue
Department of Orthopedic Surgery, Rush University Medical Center, Chicago, USA
10 shared publications Howard S. An
Department of Orthopedic Surgery Rush University Medical Center Chicago Illinois USA
6 shared publicationsNozomu Inoue
Department of Orthopedic Surgery Rush University Medical Center Chicago Illinois USA
4 shared publicationsShane J. Nho
Department of Orthopedic Surgery Rush University Medical Center Chicago Illinois USA
4 shared publicationsAlexander C. Newhouse
Department of Orthopedic Surgery Rush University Medical Center Chicago Illinois USA
3 shared publications- Dino Samartzis
Department of Orthopedic Surgery, Rush University Medical Center, Chicago, USA
3 shared publications
Latest Publications
- 12 November 2025
- Published by SAGE Publications in HIP International
- Vol. 36 (1) , 4-11
Robotic reaming, multiple screw fixation results in significantly improved initial acetabular cup stability
Background: This study aimed to compare the biomechanical performance of cups implanted with manual versus robotic reaming, single versus sequential reaming, as well as no screws, 1 screw and 2 screws. Methods: A total of 48, 56-mm diameter 3D-printed porous acetabular cups were impacted into separate polyurethane foam bone models reamed with either manual or robotic arm reaming, and either single or sequential reaming techniques. Simultaneous torsion-compression loading yielded torque at failure, angular displacement at failure and torsional stiffness of acetabular cups fixed with either 0, 1 or 2 acetabular screws. Results: Overall, torsional stiffness for robotically-reamed cups (both sequential and single) was 45% higher than those reamed via manual instrumentation (3609.0 vs. 2484.6 N·m/rad; p < 0.0001). With increasing number of acetabular screws, the torque at failure (zero screws: 60.1 N·m vs. 1 screw 67.0 N·m vs. 2 screws 97.9 N·m; p < 0.001) and angular displacement at failure (0 screws: 2.0° vs. 1 screw 1.7° vs. 2 screws 5.3°; p < 0.001) increased. There was no difference in the torque, angular displacement at failure or torsional stiffness observed between cups reamed via single or sequential reaming (all p > 0.05). Neither torque nor angular displacement showed differences at failure (all p > 0.05). Conclusions: Robotically-reamed cups demonstrated nearly 50% greater torsional stiffness than those reamed manually, suggesting that robotic reaming results in fewer deviations in sphericity, thereby optimising the congruency of the acetabulum-cup interface.
- 12 November 2025
- Published by SAGE Publications in HIP International
- Vol. 36 (1) , 4-11
Robotic reaming, multiple screw fixation results in significantly improved initial acetabular cup stability
Background: This study aimed to compare the biomechanical performance of cups implanted with manual versus robotic reaming, single versus sequential reaming, as well as no screws, 1 screw and 2 screws. Methods: A total of 48, 56-mm diameter 3D-printed porous acetabular cups were impacted into separate polyurethane foam bone models reamed with either manual or robotic arm reaming, and either single or sequential reaming techniques. Simultaneous torsion-compression loading yielded torque at failure, angular displacement at failure and torsional stiffness of acetabular cups fixed with either 0, 1 or 2 acetabular screws. Results: Overall, torsional stiffness for robotically-reamed cups (both sequential and single) was 45% higher than those reamed via manual instrumentation (3609.0 vs. 2484.6 N·m/rad; p < 0.0001). With increasing number of acetabular screws, the torque at failure (zero screws: 60.1 N·m vs. 1 screw 67.0 N·m vs. 2 screws 97.9 N·m; p < 0.001) and angular displacement at failure (0 screws: 2.0° vs. 1 screw 1.7° vs. 2 screws 5.3°; p < 0.001) increased. There was no difference in the torque, angular displacement at failure or torsional stiffness observed between cups reamed via single or sequential reaming (all p > 0.05). Neither torque nor angular displacement showed differences at failure (all p > 0.05). Conclusions: Robotically-reamed cups demonstrated nearly 50% greater torsional stiffness than those reamed manually, suggesting that robotic reaming results in fewer deviations in sphericity, thereby optimising the congruency of the acetabulum-cup interface.
- 21 February 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (6) , 2079-2091
Characterization of bone & cartilage endplate junction in the human lumbar spine: novel ultrastructural insights & association with elemental composition, vascularity and degeneration
Objective Intervertebral disc (IVD)-related pathology is associated with integrity of cartilaginous endplate (CEP), bony endplate (BEP) and their junction. However, ultrastructural details of the CEP, BEP and IVD and their interplay with disc degenerative features such as fissures and calcification are understudied. The current study aimed to ultra structurally explore CEP-BEP junction to IVD features. Methods Fifty-nine lumbar motion segments from 13 male human cadavers (range, 21–80 years of age) were analyzed macroscopically, histologically and through scanning electron microscope. The fissures present in CEP & IVD and gaps at the junction of CEP-BEP & CEP-IVD were measured and correlated with calcification, vascular channels and disc degeneration. Energy-dispersive X-ray analysis (EDX) provided the elemental composition of the CEP, BEP and IVD. Results Ultrastructural analysis revealed gaps at the CEP-BEP junction which were occasionally bridged by fine fibrillar adhesions. These junctional gap-width were in significant positive correlation with age (p = 0.001), spinal-level (p = 0.01), severity of disc degeneration (p < 0.001) and IVD calcification (p < 0.001). The vascular channels of BEP around the CEP were in significant positive correlation with age (p = 0.003), junctional gap-width (p < 0.001) & severity of disc degeneration (p < 0.001). EDX distribution of calcium in CEP was also associated significantly with junctional gap-width & vascularity (p = 0.03, p = 0.04, respectively). Conclusion This is the first study to ultrastructurally assess and map lumbar CEP, BEP and IVD in humans, noting discovery of specific phenotypic patterns of intradiscal calcification, fissures, vascularity and degeneration severity as associated with novel anatomical structures of “adhesion bridges and gaps” which are implicated in marked inflammation and pain.
- 21 February 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (6) , 2079-2091
Characterization of bone & cartilage endplate junction in the human lumbar spine: novel ultrastructural insights & association with elemental composition, vascularity and degeneration
Objective Intervertebral disc (IVD)-related pathology is associated with integrity of cartilaginous endplate (CEP), bony endplate (BEP) and their junction. However, ultrastructural details of the CEP, BEP and IVD and their interplay with disc degenerative features such as fissures and calcification are understudied. The current study aimed to ultra structurally explore CEP-BEP junction to IVD features. Methods Fifty-nine lumbar motion segments from 13 male human cadavers (range, 21–80 years of age) were analyzed macroscopically, histologically and through scanning electron microscope. The fissures present in CEP & IVD and gaps at the junction of CEP-BEP & CEP-IVD were measured and correlated with calcification, vascular channels and disc degeneration. Energy-dispersive X-ray analysis (EDX) provided the elemental composition of the CEP, BEP and IVD. Results Ultrastructural analysis revealed gaps at the CEP-BEP junction which were occasionally bridged by fine fibrillar adhesions. These junctional gap-width were in significant positive correlation with age (p = 0.001), spinal-level (p = 0.01), severity of disc degeneration (p < 0.001) and IVD calcification (p < 0.001). The vascular channels of BEP around the CEP were in significant positive correlation with age (p = 0.003), junctional gap-width (p < 0.001) & severity of disc degeneration (p < 0.001). EDX distribution of calcium in CEP was also associated significantly with junctional gap-width & vascularity (p = 0.03, p = 0.04, respectively). Conclusion This is the first study to ultrastructurally assess and map lumbar CEP, BEP and IVD in humans, noting discovery of specific phenotypic patterns of intradiscal calcification, fissures, vascularity and degeneration severity as associated with novel anatomical structures of “adhesion bridges and gaps” which are implicated in marked inflammation and pain.
- Open Access
Gut microbiome dysbiosis is associated with lumbar degenerative spondylolisthesis in symptomatic patients
Background: Lumbar degenerative spondylolisthesis (LDS), characterized as degeneration of the intervertebral disc and structural changes of the facet joints, is a condition with varying degrees of instability that may lead to pain, canal stenosis, and subsequent surgical intervention. However, the etiology of LDS remains inconclusive. Gut microbiome dysbiosis may stimulate systemic inflammation in various disorders. However, the role of such dysbiosis upon spine health remains under‐studied. The current study assessed the association of gut microbiome dysbiosis in symptomatic patients with or without LDS.Methods: A cross‐sectional analysis within the framework of a prospective study was performed. DNA was extracted from fecal samples collected from adult symptomatic patients with (n = 21) and without LDS (n = 12). Alpha and beta diversity assessed differences in fecal microbial community between groups. Taxon‐by‐taxon analysis identified microbial features with differential relative abundance between groups. Subject demographics and imaging parameters were also assessed.Results: There was no significant group differences in age, sex, race, body mass index, smoking/alcohol history, pain profiles, spinopelvic alignment, and Modic changes (p >0.05). LDS subjects had significantly higher disc degeneration severity (p = 0.018) and alpha diversity levels compared to non‐LDS subjects (p = 0.002–0.003). Significant differences in gut microbial community structure were observed between groups (p = 0.046). Subjects with LDS exhibited distinct differences at the phylum level, with a significantly higher Firmicutes to Bacteroidota ratio compared to non‐LDS (p = 0.003). Differential relative abundance analysis identified six taxa with significant differences between the two groups, with LDS demonstrating an increase in putative pro‐inflammatory bacteria (Dialister, CAG‐352) and a decrease in anti‐inflammatory bacteria (Slackia, Escherichia‐Shigella).Conclusion: This study is the first to report a significant association of gut microbiome dysbiosis and LDS in symptomatic patients, noting pro‐inflammatory bacterial taxa. This work provides a foundation for future studies addressing the role of the gut microbiome in association with spine health and disease.
Open AccessGut microbiome dysbiosis is associated with lumbar degenerative spondylolisthesis in symptomatic patients
Background: Lumbar degenerative spondylolisthesis (LDS), characterized as degeneration of the intervertebral disc and structural changes of the facet joints, is a condition with varying degrees of instability that may lead to pain, canal stenosis, and subsequent surgical intervention. However, the etiology of LDS remains inconclusive. Gut microbiome dysbiosis may stimulate systemic inflammation in various disorders. However, the role of such dysbiosis upon spine health remains under‐studied. The current study assessed the association of gut microbiome dysbiosis in symptomatic patients with or without LDS.Methods: A cross‐sectional analysis within the framework of a prospective study was performed. DNA was extracted from fecal samples collected from adult symptomatic patients with (n = 21) and without LDS (n = 12). Alpha and beta diversity assessed differences in fecal microbial community between groups. Taxon‐by‐taxon analysis identified microbial features with differential relative abundance between groups. Subject demographics and imaging parameters were also assessed.Results: There was no significant group differences in age, sex, race, body mass index, smoking/alcohol history, pain profiles, spinopelvic alignment, and Modic changes (p >0.05). LDS subjects had significantly higher disc degeneration severity (p = 0.018) and alpha diversity levels compared to non‐LDS subjects (p = 0.002–0.003). Significant differences in gut microbial community structure were observed between groups (p = 0.046). Subjects with LDS exhibited distinct differences at the phylum level, with a significantly higher Firmicutes to Bacteroidota ratio compared to non‐LDS (p = 0.003). Differential relative abundance analysis identified six taxa with significant differences between the two groups, with LDS demonstrating an increase in putative pro‐inflammatory bacteria (Dialister, CAG‐352) and a decrease in anti‐inflammatory bacteria (Slackia, Escherichia‐Shigella).Conclusion: This study is the first to report a significant association of gut microbiome dysbiosis and LDS in symptomatic patients, noting pro‐inflammatory bacterial taxa. This work provides a foundation for future studies addressing the role of the gut microbiome in association with spine health and disease.
- 2 April 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (9) , 2017-2025
3.0T magnetic resonance imaging‐based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography‐based models
This study aimed to compare three‐dimensional (3D) proximal femoral and acetabular surface models generated from 3.0T magnetic resonance imaging (MRI) to the clinical gold standard of computed tomography (CT). Ten intact fresh‐frozen cadaveric hips underwent CT and 3.0T MRI scans. The CT‐ and MRI‐based segmented models were superimposed using a validated 3D–3D registration volume‐merge method to compare them. The least surface‐to‐surface distance between the models was calculated by a point‐to‐surface calculation algorithm using a custom‐written program. The variables of interest were the signed and absolute surface‐to‐surface distance between the paired bone models. One‐sample t‐tests were performed using a signed and absolute test value of 0.16 mm and 0.37 mm, respectively, based on a previous study that validated 1.5T MRI bone models by comparison with CT bone models. For the femur, the average signed and absolute surface‐to‐surface distance was 0.18 ± 0.09 mm and 0.30 ± 0.06 mm, respectively. There was no difference in the signed surface‐to‐surface distance and the 0.16 mm test value (t = 0.650, p = 0.532). However, the absolute surface‐to‐surface difference was less than the 0.37 mm test value (t = −4.025, p = 0.003). For the acetabulum, the average signed and absolute surface‐to‐surface distance was −0.06 ± 0.06 mm and 0.26 ± 0.04 mm, respectively. The signed (t = −12.569, p < 0.001) and absolute (t = −8.688, p < 0.001) surface‐to‐surface difference were less than the 0.16 mm and 0.37 mm test values, respectively. Our data shows that 3.0T MRI bone models are more similar to CT bone models than previously validated 1.5T MRI bone models. This is likely due to the higher resolution of the 3T data.
- 2 April 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (9) , 2017-2025
3.0T magnetic resonance imaging‐based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography‐based models
This study aimed to compare three‐dimensional (3D) proximal femoral and acetabular surface models generated from 3.0T magnetic resonance imaging (MRI) to the clinical gold standard of computed tomography (CT). Ten intact fresh‐frozen cadaveric hips underwent CT and 3.0T MRI scans. The CT‐ and MRI‐based segmented models were superimposed using a validated 3D–3D registration volume‐merge method to compare them. The least surface‐to‐surface distance between the models was calculated by a point‐to‐surface calculation algorithm using a custom‐written program. The variables of interest were the signed and absolute surface‐to‐surface distance between the paired bone models. One‐sample t‐tests were performed using a signed and absolute test value of 0.16 mm and 0.37 mm, respectively, based on a previous study that validated 1.5T MRI bone models by comparison with CT bone models. For the femur, the average signed and absolute surface‐to‐surface distance was 0.18 ± 0.09 mm and 0.30 ± 0.06 mm, respectively. There was no difference in the signed surface‐to‐surface distance and the 0.16 mm test value (t = 0.650, p = 0.532). However, the absolute surface‐to‐surface difference was less than the 0.37 mm test value (t = −4.025, p = 0.003). For the acetabulum, the average signed and absolute surface‐to‐surface distance was −0.06 ± 0.06 mm and 0.26 ± 0.04 mm, respectively. The signed (t = −12.569, p < 0.001) and absolute (t = −8.688, p < 0.001) surface‐to‐surface difference were less than the 0.16 mm and 0.37 mm test values, respectively. Our data shows that 3.0T MRI bone models are more similar to CT bone models than previously validated 1.5T MRI bone models. This is likely due to the higher resolution of the 3T data.
- 27 September 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (2) , 223-233
3-dimensionally printed patient-specific glenoid drill guides vs. standard nonspecific instrumentation: a randomized controlled trial comparing the accuracy of glenoid component placement in anatomic total shoulder arthroplasty
- 27 September 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (2) , 223-233
3-dimensionally printed patient-specific glenoid drill guides vs. standard nonspecific instrumentation: a randomized controlled trial comparing the accuracy of glenoid component placement in anatomic total shoulder arthroplasty
- 21 October 2022
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (6) , 1256-1265
Noninvasive shape‐fitting method quantifies cam morphology in femoroacetabular impingement syndrome: Implications for diagnosis and surgical planning
There are considerable limitations associated with the standard 2D imaging currently used for the diagnosis and surgical planning of cam‐type femoroacetabular impingement syndrome (FAIS). The aim of this study was to determine the accuracy of a new patient‐specific shape‐fitting method that quantifies cam morphology in 3D based solely on preoperative MRI imaging. Preoperative and postoperative 1.5T MRI scans were performed on n = 15 patients to generate 3D models of the proximal femur, in turn used to create the actual and the virtual cam. The actual cams were reconstructed by subtracting the postoperative from the preoperative 3D model and used as reference, while the virtual cams were generated by subtracting the preoperative 3D model from the virtual shape template produced with the shape‐fitting method based solely on preoperative MRI scans. The accuracy of the shape‐fitting method was tested on all patients by evaluating the agreement between the metrics of height, surface area, and volume that quantified virtual and actual cams. Accuracy of the shape‐fitting method was demonstrated obtaining a 97.8% average level of agreement between these metrics. In conclusion, the shape‐fitting technique is a noninvasive and patient‐specific tool for the quantification and localization of cam morphology. Future studies will include the implementation of the technique within a clinically based software for diagnosis and surgical planning for cam‐type FAIS.
- 21 October 2022
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (6) , 1256-1265
Noninvasive shape‐fitting method quantifies cam morphology in femoroacetabular impingement syndrome: Implications for diagnosis and surgical planning
There are considerable limitations associated with the standard 2D imaging currently used for the diagnosis and surgical planning of cam‐type femoroacetabular impingement syndrome (FAIS). The aim of this study was to determine the accuracy of a new patient‐specific shape‐fitting method that quantifies cam morphology in 3D based solely on preoperative MRI imaging. Preoperative and postoperative 1.5T MRI scans were performed on n = 15 patients to generate 3D models of the proximal femur, in turn used to create the actual and the virtual cam. The actual cams were reconstructed by subtracting the postoperative from the preoperative 3D model and used as reference, while the virtual cams were generated by subtracting the preoperative 3D model from the virtual shape template produced with the shape‐fitting method based solely on preoperative MRI scans. The accuracy of the shape‐fitting method was tested on all patients by evaluating the agreement between the metrics of height, surface area, and volume that quantified virtual and actual cams. Accuracy of the shape‐fitting method was demonstrated obtaining a 97.8% average level of agreement between these metrics. In conclusion, the shape‐fitting technique is a noninvasive and patient‐specific tool for the quantification and localization of cam morphology. Future studies will include the implementation of the technique within a clinically based software for diagnosis and surgical planning for cam‐type FAIS.
- 12 September 2022
- Published by ASM International
- p. 402-415
Personalized Surgical Instruments
- Open Access
- 7 April 2022
- Published by Springer Nature in Journal of Bio- and Tribo-Corrosion
- Vol. 8 (2) , 1-14
Corrosion Behavior of Selective Laser Melting (SLM) Manufactured Ti6Al4V Alloy in Saline and BCS Solution
The frequency of surgeries involving the use of metal implants in orthopedic medicine to replace degenerative or fractured joints is increasing, and it is therefore important to optimize the lifespan and quality of these implants. Advances in additive manufacturing (AM), or 3D printing, are creating new opportunities to personalize implants in ways that reduce mechanical stress at the joint implant interface and improve bone ingrowth and implant stability; however, it is not well understood if and to what degree the AM process alters the corrosion behavior of the materials it produces. In this study, six Ti6Al4V prints manufactured via a selective laser melting (SLM) method were examined regarding their corrosion behavior in both saline and bovine calf serum (BCS) solutions. Ecorr and Icorr values were comparable between the CM-Ti6Al4V control and SLM-EDM surfaces; however, SLM surfaces were found to have more narrow passivation behavior evidenced by significant decreases in Epass values relative to CM-Ti6Al4V. We believe this is a consequence of microstructural differences between CM-Ti6Al4V and SLM-Ti6Al4V. Specifically, the SLM-Ti6Al4V demonstrated a dominant α′ martensitic microstructure and decreased vanadium-rich β-phase. BCS solution had a detrimental effect on potential parameters, Ecorr and OCP, decreasing these values relative to their saline counterparts. Increased surface roughness of the SLM-printed surface seemed to amplify the effects of the BCS solution. Furthermore, modest decreases in Epass and Ipass were observed in BCS solution, suggesting that the presence of protein may also interfere with passivation behavior. These findings have implications for how SLM-Ti6Al4V implants will perform in vivo and could possibly influence implant longevity and performance.
- 7 April 2022
- Published by Springer Nature in Journal of Bio- and Tribo-Corrosion
- Vol. 8 (2) , 1-14
Open AccessCorrosion Behavior of Selective Laser Melting (SLM) Manufactured Ti6Al4V Alloy in Saline and BCS Solution
The frequency of surgeries involving the use of metal implants in orthopedic medicine to replace degenerative or fractured joints is increasing, and it is therefore important to optimize the lifespan and quality of these implants. Advances in additive manufacturing (AM), or 3D printing, are creating new opportunities to personalize implants in ways that reduce mechanical stress at the joint implant interface and improve bone ingrowth and implant stability; however, it is not well understood if and to what degree the AM process alters the corrosion behavior of the materials it produces. In this study, six Ti6Al4V prints manufactured via a selective laser melting (SLM) method were examined regarding their corrosion behavior in both saline and bovine calf serum (BCS) solutions. Ecorr and Icorr values were comparable between the CM-Ti6Al4V control and SLM-EDM surfaces; however, SLM surfaces were found to have more narrow passivation behavior evidenced by significant decreases in Epass values relative to CM-Ti6Al4V. We believe this is a consequence of microstructural differences between CM-Ti6Al4V and SLM-Ti6Al4V. Specifically, the SLM-Ti6Al4V demonstrated a dominant α′ martensitic microstructure and decreased vanadium-rich β-phase. BCS solution had a detrimental effect on potential parameters, Ecorr and OCP, decreasing these values relative to their saline counterparts. Increased surface roughness of the SLM-printed surface seemed to amplify the effects of the BCS solution. Furthermore, modest decreases in Epass and Ipass were observed in BCS solution, suggesting that the presence of protein may also interfere with passivation behavior. These findings have implications for how SLM-Ti6Al4V implants will perform in vivo and could possibly influence implant longevity and performance.
- Open Access
- 4 November 2021
- Published by SAGE Publications in Global Spine Journal
- Vol. 13 (7) , 1803-1811
Computed Tomography Osteoabsorptiometry Evaluation of Cervical Endplate Subchondral Bone Mineral Density
Basic Science. Poor subchondral bone mineral density (sBMD) has been linked with subsidence of cervical interbody devices or grafts, which are traditionally placed centrally on the endplates. Considering that sBMD reflects long-term stress distributions, we hypothesize that the cervical uncovertebral joints are denser than the central endplate region. This study sought to investigate density distributions using computed tomography osteoabsorptiometry (CT-OAM). Twelve human cervical spines from C3–C7 (60 vertebrae, 120 endplates) were imaged with CT and segmented to create 3D reconstructions. The superior and inferior endplates were isolated, and the sBMD of the whole endplate, endplate center, and uncus was evaluated using CT-OAM. Density distributions were compared across the subaxial cervical spine. The uncinate region of the inferior and superior endplates was significantly denser than the central endplate across all vertebral levels (P < .01). When comparing sBMD of the whole inferior and superior endplates, the superior endplate was significantly denser than the inferior endplate (P < .0001). However, the inferior uncus was denser than the superior uncus (P = .035). When assessing sBMD by vertebral level, peak densities were observed at C4 and C5, while C7 was, on average, significantly less dense than all other vertebrae. The subchondral bone of the cervical uncovertebral joints is significantly denser than the central endplates. While the superior endplate in its entirety is denser than the inferior endplate, the inverse was true for the uncovertebral joints. This study serves as a basis for future investigations of new implant designs and their implications on subsidence.
- 4 November 2021
- Published by SAGE Publications in Global Spine Journal
- Vol. 13 (7) , 1803-1811
Open AccessComputed Tomography Osteoabsorptiometry Evaluation of Cervical Endplate Subchondral Bone Mineral Density
Basic Science. Poor subchondral bone mineral density (sBMD) has been linked with subsidence of cervical interbody devices or grafts, which are traditionally placed centrally on the endplates. Considering that sBMD reflects long-term stress distributions, we hypothesize that the cervical uncovertebral joints are denser than the central endplate region. This study sought to investigate density distributions using computed tomography osteoabsorptiometry (CT-OAM). Twelve human cervical spines from C3–C7 (60 vertebrae, 120 endplates) were imaged with CT and segmented to create 3D reconstructions. The superior and inferior endplates were isolated, and the sBMD of the whole endplate, endplate center, and uncus was evaluated using CT-OAM. Density distributions were compared across the subaxial cervical spine. The uncinate region of the inferior and superior endplates was significantly denser than the central endplate across all vertebral levels (P < .01). When comparing sBMD of the whole inferior and superior endplates, the superior endplate was significantly denser than the inferior endplate (P < .0001). However, the inferior uncus was denser than the superior uncus (P = .035). When assessing sBMD by vertebral level, peak densities were observed at C4 and C5, while C7 was, on average, significantly less dense than all other vertebrae. The subchondral bone of the cervical uncovertebral joints is significantly denser than the central endplates. While the superior endplate in its entirety is denser than the inferior endplate, the inverse was true for the uncovertebral joints. This study serves as a basis for future investigations of new implant designs and their implications on subsidence.