Anthony N. Sinclair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anthony N. Sinclair has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Farhang Honarvar
NDE Lab, Faculty of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
6 shared publications - Sina Sodagar
Faculty of Mechanical Engineering, K. N. Toosi University of Technology, Pardis St., Molla Sadra Ave., Vanak Sq., Postal code 1999143344, 16579 Tehran, Iran
3 shared publications - Tobin Filleter
Department of Mechanical & Industrial Engineering, University of Toronto, Toronto, Canada
3 shared publications - Samaneh Hosseingholizadeh
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON, Canada
2 shared publications - Thomas Coyle
Department of Materials Science and Engineering, University of Toronto, Toronto, ON M5S 3E4, Canada
2 shared publications - Andrey M. Chertov
University of Windso
1 shared publication
Latest Publications
- Open Access
- 29 July 2026
- Published by Springer Nature in Discover Mechanical Engineering
- Vol. 5 (1) , 143
Effects of handle vibration on handgrip strength of operators of a diesel powered single axle tractor
- 29 July 2026
- Published by Springer Nature in Discover Mechanical Engineering
- Vol. 5 (1) , 143
Open AccessEffects of handle vibration on handgrip strength of operators of a diesel powered single axle tractor
- Open Access
Natural Frequency Transmissibility for Detection of Cracks in Horizontal Axis Wind Turbine Blades
Defects on horizontal axis wind turbine blades are difficult to identify and monitor with conventional forms of non-destructive examination due to the blade’s large size and limited accessibility during continuous operation. This article examines both strain and acceleration transmissibility as methods of continuous damage detection on wind turbine blades. A scaled 117 cm offshore wind turbine blade was first designed, 3D printed, and modelled numerically in ANSYS. Transverse cracks were deliberately introduced to the blade at 10 cm intervals along its leading edge. Subsequent changes in the transmissibility, relative to an undamaged baseline model, were measured using different variable combinations at the blade’s first three natural frequencies. Experimental results indicated that strain transmissibility was able to locate a 1.0 cm defect at a range of 70–110 cm from the blade hub using the amplitudes of the first natural frequency of vibration. The numerical model was able to simulate the strain experimental results and was determined to be valid for future defect characterization. Acceleration transmissibility was unable to experimentally identify defects sized at 1.0 cm and below but was able to identify 1.0 cm sized defects numerically. It was concluded that transmissibility is viable for continuous damage detection on blades but that further research into other defect types and locations is required prior to conducting full-scale testing.
Open AccessNatural Frequency Transmissibility for Detection of Cracks in Horizontal Axis Wind Turbine Blades
Defects on horizontal axis wind turbine blades are difficult to identify and monitor with conventional forms of non-destructive examination due to the blade’s large size and limited accessibility during continuous operation. This article examines both strain and acceleration transmissibility as methods of continuous damage detection on wind turbine blades. A scaled 117 cm offshore wind turbine blade was first designed, 3D printed, and modelled numerically in ANSYS. Transverse cracks were deliberately introduced to the blade at 10 cm intervals along its leading edge. Subsequent changes in the transmissibility, relative to an undamaged baseline model, were measured using different variable combinations at the blade’s first three natural frequencies. Experimental results indicated that strain transmissibility was able to locate a 1.0 cm defect at a range of 70–110 cm from the blade hub using the amplitudes of the first natural frequency of vibration. The numerical model was able to simulate the strain experimental results and was determined to be valid for future defect characterization. Acceleration transmissibility was unable to experimentally identify defects sized at 1.0 cm and below but was able to identify 1.0 cm sized defects numerically. It was concluded that transmissibility is viable for continuous damage detection on blades but that further research into other defect types and locations is required prior to conducting full-scale testing.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 544-552
An Ultrasonic Adaptive Beamforming Method and Its Application for Trans-Skull Imaging of Certain Types of Head Injuries; Part II: Reception Mode and Adaptive Imaging
Objective: Background theory and a new algorithm for single-point adaptive focusing in transmission mode through ultrasonic barriers via one-dimensional phased arrays were reported in part I. In this paper the algorithm is further extended and implemented into a full adaptive beamforming process, including complete transmission and reception modes. Methods: Corrected time delay patterns, adapted to the local acoustical and geometrical properties of the barrier, are calculated and applied in both modes. Further, an adaptive imaging process is also developed that implements the proposed beamforming process for two-dimensional imaging through randomly shaped multilayered phase-aberrating structures. The method is optimized for the case of human skull as the ultrasound barrier and its application for transcranial imaging is discussed. Results: Laboratory results of adaptive imaging through realistic skull-mimicking phantoms are presented. The algorithms are implemented on a 64-channel ultrasound open-source phased array platform controlling a standard 128-element biomedical phased array. Irregularly shaped reflectors with characteristic dimensions of the order of ∼0.5mm to ∼4.5mm were used as targets behind the skull phantoms in our experiments. Minimum and maximum distortional target displacements of 2.2mm and 25.3mm (in 12cm depth) were observed in sonograms when uncompensated time delays were used. By contrast, the positioning errors ranged from 0.0 to 0.9 mm when our algorithm was employed. Conclusion and Significance: The adaptive imaging results demonstrate strong potential of the proposed technique for diagnostic imaging of acoustically reflective head injuries directly through intact human skull.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 544-552
An Ultrasonic Adaptive Beamforming Method and Its Application for Trans-Skull Imaging of Certain Types of Head Injuries; Part II: Reception Mode and Adaptive Imaging
Objective: Background theory and a new algorithm for single-point adaptive focusing in transmission mode through ultrasonic barriers via one-dimensional phased arrays were reported in part I. In this paper the algorithm is further extended and implemented into a full adaptive beamforming process, including complete transmission and reception modes. Methods: Corrected time delay patterns, adapted to the local acoustical and geometrical properties of the barrier, are calculated and applied in both modes. Further, an adaptive imaging process is also developed that implements the proposed beamforming process for two-dimensional imaging through randomly shaped multilayered phase-aberrating structures. The method is optimized for the case of human skull as the ultrasound barrier and its application for transcranial imaging is discussed. Results: Laboratory results of adaptive imaging through realistic skull-mimicking phantoms are presented. The algorithms are implemented on a 64-channel ultrasound open-source phased array platform controlling a standard 128-element biomedical phased array. Irregularly shaped reflectors with characteristic dimensions of the order of ∼0.5mm to ∼4.5mm were used as targets behind the skull phantoms in our experiments. Minimum and maximum distortional target displacements of 2.2mm and 25.3mm (in 12cm depth) were observed in sonograms when uncompensated time delays were used. By contrast, the positioning errors ranged from 0.0 to 0.9 mm when our algorithm was employed. Conclusion and Significance: The adaptive imaging results demonstrate strong potential of the proposed technique for diagnostic imaging of acoustically reflective head injuries directly through intact human skull.
- 10 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 58 (5) , 1-11
Enhancement of Defect Characterization With AC Magnetic Flux Leakage: Far-Side Defect Shape Estimation and Sensor Lift-Off Compensation
One of the most common methods for performing non-destructive testing (NDT) of the steel tank floors in aboveground storage tanks is dc magnetic flux leakage (MFL). This test method gives an estimate of the defect depth and width based on the MFL signal strength and its peak location, respectively. A key limitation is that the signal strength depends on not only the defect depth and width but also various other factors including a defect’s wall profile and sensor lift-off. Moreover, in a practical MFL test, the sensor lift-off changes due to surface roughness and uneven steel plate surface in tank floors. We present an ac MFL system to increase the accuracy of defect characterization by: 1) distinguishing between two common defect shapes located on the far side of the steel plate used in a typical above storage tank (AST) floor: lake-shaped and rectangular defects and 2) developing a sensor lift-off compensation scheme based on ac signal phase. Simulation results show that skewness of the ac MFL can be used to distinguish between far-side lake-shaped and rectangular defects. AC MFL signal phase is shown to be a suitable compensator for the dependence of signal strength on unintended variations in sensor lift-off. The simulation results have been validated through experiments.
- 10 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 58 (5) , 1-11
Enhancement of Defect Characterization With AC Magnetic Flux Leakage: Far-Side Defect Shape Estimation and Sensor Lift-Off Compensation
One of the most common methods for performing non-destructive testing (NDT) of the steel tank floors in aboveground storage tanks is dc magnetic flux leakage (MFL). This test method gives an estimate of the defect depth and width based on the MFL signal strength and its peak location, respectively. A key limitation is that the signal strength depends on not only the defect depth and width but also various other factors including a defect’s wall profile and sensor lift-off. Moreover, in a practical MFL test, the sensor lift-off changes due to surface roughness and uneven steel plate surface in tank floors. We present an ac MFL system to increase the accuracy of defect characterization by: 1) distinguishing between two common defect shapes located on the far side of the steel plate used in a typical above storage tank (AST) floor: lake-shaped and rectangular defects and 2) developing a sensor lift-off compensation scheme based on ac signal phase. Simulation results show that skewness of the ac MFL can be used to distinguish between far-side lake-shaped and rectangular defects. AC MFL signal phase is shown to be a suitable compensator for the dependence of signal strength on unintended variations in sensor lift-off. The simulation results have been validated through experiments.
- Open Access
Influence of Magnetostriction Induced by the Periodic Permanent Magnet Electromagnetic Acoustic Transducer (PPM EMAT) on Steel
The periodic permanent magnet electromagnetic acoustic transducer (PPM EMAT) is a sensor that can generate and receive shear horizontal (SH) waves without direct contact with the inspected medium using the Lorentz mechanism. However, the PPM EMAT experiences high signal variance on ferromagnetic steel under specific conditions, such as a change in signal amplitude when the sensor is moved in the direction of SH wave propagation. Magnetostriction effects are hypothesized to be the cause of these anomalous behaviors; the objective of this paper is to determine the relative strengths of the magnetostriction and Lorentz wave generation mechanisms for this type of EMAT on steel. This goal is accomplished through the use of a second EMAT, which induces only magnetostriction (MS-EMAT), to calibrate a novel semi-empirical magnetostriction model. It is found that magnetostriction effects reduce the amplitude of the SH wave generated by this particular PPM EMAT transmitter by an average of 29% over a range of input currents. It is also determined that magnetostriction is significant only in the investigated PPM EMAT transmitter, not the receiver. In terms of practical application, it is shown that the MS-EMAT is less sensitive to changes in the static and dynamic fields than PPM EMATs at specific operating points; this makes the MS-EMAT a viable alternative for nondestructive evaluation despite lower amplitudes.
Open AccessInfluence of Magnetostriction Induced by the Periodic Permanent Magnet Electromagnetic Acoustic Transducer (PPM EMAT) on Steel
The periodic permanent magnet electromagnetic acoustic transducer (PPM EMAT) is a sensor that can generate and receive shear horizontal (SH) waves without direct contact with the inspected medium using the Lorentz mechanism. However, the PPM EMAT experiences high signal variance on ferromagnetic steel under specific conditions, such as a change in signal amplitude when the sensor is moved in the direction of SH wave propagation. Magnetostriction effects are hypothesized to be the cause of these anomalous behaviors; the objective of this paper is to determine the relative strengths of the magnetostriction and Lorentz wave generation mechanisms for this type of EMAT on steel. This goal is accomplished through the use of a second EMAT, which induces only magnetostriction (MS-EMAT), to calibrate a novel semi-empirical magnetostriction model. It is found that magnetostriction effects reduce the amplitude of the SH wave generated by this particular PPM EMAT transmitter by an average of 29% over a range of input currents. It is also determined that magnetostriction is significant only in the investigated PPM EMAT transmitter, not the receiver. In terms of practical application, it is shown that the MS-EMAT is less sensitive to changes in the static and dynamic fields than PPM EMATs at specific operating points; this makes the MS-EMAT a viable alternative for nondestructive evaluation despite lower amplitudes.
- Open Access
Sensors for Ultrasonic Nondestructive Testing (NDT) in Harsh Environments
In this special issue of Sensors, seven peer-reviewed manuscripts appear on the topic of ultrasonic transducer design and operation in harsh environments: elevated temperature, high gamma and neutron fields, or the presence of chemically aggressive species. Motivations for these research and development projects are strongly focused on nuclear power plant inspections (particularly liquid-sodium cooled reactors), and nondestructive testing of high-temperature piping installations. It is anticipated that we may eventually see extensive use of permanently mounted robust transducers for in-service monitoring of petrochemical plants and power generations stations; quality control in manufacturing plants; and primary and secondary process monitoring in the fabrication of engineering materials.
Open AccessSensors for Ultrasonic Nondestructive Testing (NDT) in Harsh Environments
In this special issue of Sensors, seven peer-reviewed manuscripts appear on the topic of ultrasonic transducer design and operation in harsh environments: elevated temperature, high gamma and neutron fields, or the presence of chemically aggressive species. Motivations for these research and development projects are strongly focused on nuclear power plant inspections (particularly liquid-sodium cooled reactors), and nondestructive testing of high-temperature piping installations. It is anticipated that we may eventually see extensive use of permanently mounted robust transducers for in-service monitoring of petrochemical plants and power generations stations; quality control in manufacturing plants; and primary and secondary process monitoring in the fabrication of engineering materials.
- Open Access
Dry Coupling of Ultrasonic Transducer Components for High Temperature Applications
The viability for dry coupling of piezoelectric ultrasonic transducer components was investigated, using a thin foil of annealed silver as a filler material/coupling agent at each component interface. Criteria used for room temperature evaluation were centered on signal-to-noise ratio (SNR) and echo bandwidth, for a Li-Nb based transducer operating in pulse-echo mode. A normal clamping stress of only 25 MPa, applied repeatedly over three loading cycles on a precisely-aligned transducer stack, was sufficient to yield backwall echoes with a SNR greater than 25 dB, and a 3 dB bandwidth of approximately 65%. This compares to a SNR of 32 dB and a 3 dB bandwidth of 65%, achievable when all transducer interfaces were coupled with ultrasonic gel. The respective roles of a soft filler material, alignment of transducer components, cyclic clamping, component roughness, and component flatness were evaluated in achieving this high efficiency dry coupling, with transducer clamping forces far lower than previously reported. Preliminary high temperature tests indicate that this coupling method is suitable for high temperature and achieves signal quality comparable to that at room temperature with ultrasonic gel.
Open AccessDry Coupling of Ultrasonic Transducer Components for High Temperature Applications
The viability for dry coupling of piezoelectric ultrasonic transducer components was investigated, using a thin foil of annealed silver as a filler material/coupling agent at each component interface. Criteria used for room temperature evaluation were centered on signal-to-noise ratio (SNR) and echo bandwidth, for a Li-Nb based transducer operating in pulse-echo mode. A normal clamping stress of only 25 MPa, applied repeatedly over three loading cycles on a precisely-aligned transducer stack, was sufficient to yield backwall echoes with a SNR greater than 25 dB, and a 3 dB bandwidth of approximately 65%. This compares to a SNR of 32 dB and a 3 dB bandwidth of 65%, achievable when all transducer interfaces were coupled with ultrasonic gel. The respective roles of a soft filler material, alignment of transducer components, cyclic clamping, component roughness, and component flatness were evaluated in achieving this high efficiency dry coupling, with transducer clamping forces far lower than previously reported. Preliminary high temperature tests indicate that this coupling method is suitable for high temperature and achieves signal quality comparable to that at room temperature with ultrasonic gel.
- 5 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (4) , 1-7
Evaluation of a Magnetic Dipole Model in a DC Magnetic Flux Leakage System
One of the most common methods for performing non-destructive testing in steel tank floors is DC magnetic flux leakage (MFL). The magnetic dipole method is the most widely used mathematical technique to predict the MFL from defects in such structures. However, due to the complexity of an exact analytical description of an MFL system, researchers often make coarse approximations for the profile of the magnetic surface charge density σₘ, orientation of the magnetic field H, and variation of relative permeability μ r. In this paper, the validity of these approximations is evaluated for 2-D rectangular defects in a steel plate, by comparing model predications with finite element results. The primary sources of deviation between the approximate solutions and true MFL profiles were found to be caused by assumptions that 1) σₘ on the specimen surface adjacent to a flaw is zero. This assumption is equivalent to treating the orientation of H to be parallel to the specimen surface, even at locations in close proximity to a flaw and 2) local variation in permeability around the defect can be ignored. This approximation was found to cause an underestimation of σₘ and, consequently, the predicted MFL. In contrast, approximating σₘ to be zero at the bottom of a flaw, and approximating uniform distribution for σ ₘ on the vertical defect sides of a slot defect was found to generate only minor errors in an estimate of flux leakage.
- 5 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (4) , 1-7
Evaluation of a Magnetic Dipole Model in a DC Magnetic Flux Leakage System
One of the most common methods for performing non-destructive testing in steel tank floors is DC magnetic flux leakage (MFL). The magnetic dipole method is the most widely used mathematical technique to predict the MFL from defects in such structures. However, due to the complexity of an exact analytical description of an MFL system, researchers often make coarse approximations for the profile of the magnetic surface charge density σₘ, orientation of the magnetic field H, and variation of relative permeability μ r. In this paper, the validity of these approximations is evaluated for 2-D rectangular defects in a steel plate, by comparing model predications with finite element results. The primary sources of deviation between the approximate solutions and true MFL profiles were found to be caused by assumptions that 1) σₘ on the specimen surface adjacent to a flaw is zero. This assumption is equivalent to treating the orientation of H to be parallel to the specimen surface, even at locations in close proximity to a flaw and 2) local variation in permeability around the defect can be ignored. This approximation was found to cause an underestimation of σₘ and, consequently, the predicted MFL. In contrast, approximating σₘ to be zero at the bottom of a flaw, and approximating uniform distribution for σ ₘ on the vertical defect sides of a slot defect was found to generate only minor errors in an estimate of flux leakage.
- Open Access
- 23 December 2018
- Published by MDPI AG in Instruments
- Vol. 3 (1) , 2
Brazing Strategies for High Temperature Ultrasonic Transducers Based on LiNbO3 Piezoelectric Elements
Long-term installation of ultrasonic transducers in high temperature environments allows for continuous monitoring of critical components and processes without the need to halt industrial operations. Transducer designs based on the high-Curie-point piezoelectric material lithium niobate have been shown to both be effective and stable at extreme temperatures for long-term installation. In this study, several brazing techniques are evaluated, all of which aim to provide both mechanical bonding and acoustic coupling directly to a bare lithium niobate piezoelectric element. Two brazing materials—a novel silver-copper braze applied in a reactive air environment and an aluminum-based braze applied in a vacuum environment—are found to be suitable for ultrasound transmission at elevated temperatures. Reliable wide-bandwidth and low-noise ultrasound transmission is achieved between room temperature and 800 °C.
- 23 December 2018
- Published by MDPI AG in Instruments
- Vol. 3 (1) , 2
Open AccessBrazing Strategies for High Temperature Ultrasonic Transducers Based on LiNbO3 Piezoelectric Elements
Long-term installation of ultrasonic transducers in high temperature environments allows for continuous monitoring of critical components and processes without the need to halt industrial operations. Transducer designs based on the high-Curie-point piezoelectric material lithium niobate have been shown to both be effective and stable at extreme temperatures for long-term installation. In this study, several brazing techniques are evaluated, all of which aim to provide both mechanical bonding and acoustic coupling directly to a bare lithium niobate piezoelectric element. Two brazing materials—a novel silver-copper braze applied in a reactive air environment and an aluminum-based braze applied in a vacuum environment—are found to be suitable for ultrasound transmission at elevated temperatures. Reliable wide-bandwidth and low-noise ultrasound transmission is achieved between room temperature and 800 °C.
- 1 January 2017
- Published by AIP Publishing
Resolution of overlapping ultrasonic echoes using consistent frequency domain amplitude-phase relationships
We introduce a new post-processing ultrasonic echo identification algorithm for the special case of two overlapping echoes. Compared to dictionary-based deconvolution, the algorithm has a reduced solution space and can reconstruct echoes that have a better fit with the acquired data. We have tested the algorithm using a synthetic test case using two dissimilar echoes and the algorithm was able to reconstruct the constituent echoes with good accuracy.
- 1 January 2017
- Published by AIP Publishing
Resolution of overlapping ultrasonic echoes using consistent frequency domain amplitude-phase relationships
We introduce a new post-processing ultrasonic echo identification algorithm for the special case of two overlapping echoes. Compared to dictionary-based deconvolution, the algorithm has a reduced solution space and can reconstruct echoes that have a better fit with the acquired data. We have tested the algorithm using a synthetic test case using two dissimilar echoes and the algorithm was able to reconstruct the constituent echoes with good accuracy.