Justin Konkle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Justin Konkle has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Patrick William Goodwill
Magnetic Insight Inc
13 shared publications Bo Zheng
7 shared publicationsSteven M. Conolly
6 shared publicationsKuan Lu
5 shared publicationsSteven Conolly
UC-Berkeley
4 shared publicationsEmine U. Saritas
University of California, Berkeley; Department of Bioengineering, USA
3 shared publications
Latest Publications
- Open Access
- 17 March 2026
- Published by Springer Nature in Research Square
Magnetic Particle Imaging in Human Subjects
Magnetic Particle Imaging (MPI) is a tracer-based medical imaging modality that detects magnetic nanoparticles with no background tissue signal. MPI acquires quantitative, high-sensitivity tomographic images of shelf-stable magnetic tracers that safely produce signals in vivo for weeks or even months. These features can fill capability gaps in medical imaging for applications benefiting from tracer specificity with an extended imaging window. Despite two decades of preclinical validation and multiple published human-scale imagers, MPI has not previously been demonstrated in human subjects. Here we report MPI imaging in two subjects following subcutaneous administration of magnetic tracer in the scalp and foot. Our results showed quantitative and longitudinal visualization of lymphatic drainage for up to six months, with supporting validation in a mouse model. Imaging in human subjects required the development and verification of a novel clinical imager, including magnetostimulation threshold testing of all magnetic fields used in imaging sequences. To understand MPI in the context of existing medical imaging technologies, we benchmarked MPI imaging performance against SPECT using lymphatic system phantom models. These findings demonstrate that MPI can translate from animals to human subjects, and establish MPI as a new tool for longitudinal tracer imaging in medicine. The addition of MPI to the clinical imaging toolbox could enable new approaches and capabilities for diagnosis, real-time interventions, and treatment monitoring across a broad range of clinical applications.
- 17 March 2026
- Published by Springer Nature in Research Square
Open AccessMagnetic Particle Imaging in Human Subjects
Magnetic Particle Imaging (MPI) is a tracer-based medical imaging modality that detects magnetic nanoparticles with no background tissue signal. MPI acquires quantitative, high-sensitivity tomographic images of shelf-stable magnetic tracers that safely produce signals in vivo for weeks or even months. These features can fill capability gaps in medical imaging for applications benefiting from tracer specificity with an extended imaging window. Despite two decades of preclinical validation and multiple published human-scale imagers, MPI has not previously been demonstrated in human subjects. Here we report MPI imaging in two subjects following subcutaneous administration of magnetic tracer in the scalp and foot. Our results showed quantitative and longitudinal visualization of lymphatic drainage for up to six months, with supporting validation in a mouse model. Imaging in human subjects required the development and verification of a novel clinical imager, including magnetostimulation threshold testing of all magnetic fields used in imaging sequences. To understand MPI in the context of existing medical imaging technologies, we benchmarked MPI imaging performance against SPECT using lymphatic system phantom models. These findings demonstrate that MPI can translate from animals to human subjects, and establish MPI as a new tool for longitudinal tracer imaging in medicine. The addition of MPI to the clinical imaging toolbox could enable new approaches and capabilities for diagnosis, real-time interventions, and treatment monitoring across a broad range of clinical applications.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2319-2329
A Physics-Based Computational Forward Model for Efficient Image Reconstruction in Magnetic Particle Imaging
This article derives and implements a computational physics model for model-based image reconstruction in magnetic particle imaging (MPI) applications. To our knowledge, this is the first ever computationally tractable model-based image reconstruction in MPI, which is neither constructed from calibration or simulation experiments or limited to specific scan acquisition geometries. The derived model results in a system constructed from a series of fast linear transforms, each of which incorporate the individual components from the paramagnetic model. These include the field free point velocity and location, gradient strength, receive coil sensitivity, and receive chain filtering. Each of these modeling components are amendable to any changes in the acquisition parameters. This allows us to adopt a computationally tractable system matrix modeling approach to MPI for any scan specific parameters at very high pixel resolutions. The model is derived from first principles, and it results from taking the fundamental MPI signal theory and decomposing these modeling equations into the series of linear transforms acting on a pixelated image. Each transform is formally defined in matrix form but implemented in a matrix-free fashion with fast and/or sparse operations. For these reasons, our new model should be a fundamental tool in the future of computational imaging in MPI. We demonstrate our new method on a variety of pre-clinical and simulated data sets, and these results confirm that our method is both efficient and accurate.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2319-2329
A Physics-Based Computational Forward Model for Efficient Image Reconstruction in Magnetic Particle Imaging
This article derives and implements a computational physics model for model-based image reconstruction in magnetic particle imaging (MPI) applications. To our knowledge, this is the first ever computationally tractable model-based image reconstruction in MPI, which is neither constructed from calibration or simulation experiments or limited to specific scan acquisition geometries. The derived model results in a system constructed from a series of fast linear transforms, each of which incorporate the individual components from the paramagnetic model. These include the field free point velocity and location, gradient strength, receive coil sensitivity, and receive chain filtering. Each of these modeling components are amendable to any changes in the acquisition parameters. This allows us to adopt a computationally tractable system matrix modeling approach to MPI for any scan specific parameters at very high pixel resolutions. The model is derived from first principles, and it results from taking the fundamental MPI signal theory and decomposing these modeling equations into the series of linear transforms acting on a pixelated image. Each transform is formally defined in matrix form but implemented in a matrix-free fashion with fast and/or sparse operations. For these reasons, our new model should be a fundamental tool in the future of computational imaging in MPI. We demonstrate our new method on a variety of pre-clinical and simulated data sets, and these results confirm that our method is both efficient and accurate.
- Open Access
Multichannel joint image reconstruction allows for artifact-free focused small field of view magnetic particle imaging
Magnetic Particle Imaging (MPI) directly detects superparamagnetic iron oxide (SPIO) labeled cells. We have used MPI to detect SPIO-labeled dendritic cells (DC) migrated to the popliteal lymph nodes (pLN) after injection into the hind footpads. However, in some cases the low pLN signal could not be resolved from nearby higher footpad signal where window leveling to pLN signal oversaturated the footpad signal. The same limitation occurs when SPIO is injected intravenously, accumulates in the liver, and prevents isolation of regions of interest with lower signals. Previous studies have reported on the issue of resolving a wide range of differing iron concentration. A small focused field of view (FOV), to exclude high sources of nearby signal cannot be performed with the standard reconstruction algorithm equipped on the MomentumTM MPI scanner because it is assumed that there is no signal at the edge of the FOV and these values are set to zero for each line along the transmit axis. However, when there is signal at the FOV edge, an inverted negative artifact is created. The multichannel joint reconstruction method uses an iterative reconstruction technique to recover edge information using information from an orthogonal axis, preventing this artifact and allowing the user to prescribe a small FOV on the region of interest. Here we describe the implementation of this method to isolate and quantify low regions of MPI signal from higher regions.
Open AccessMultichannel joint image reconstruction allows for artifact-free focused small field of view magnetic particle imaging
Magnetic Particle Imaging (MPI) directly detects superparamagnetic iron oxide (SPIO) labeled cells. We have used MPI to detect SPIO-labeled dendritic cells (DC) migrated to the popliteal lymph nodes (pLN) after injection into the hind footpads. However, in some cases the low pLN signal could not be resolved from nearby higher footpad signal where window leveling to pLN signal oversaturated the footpad signal. The same limitation occurs when SPIO is injected intravenously, accumulates in the liver, and prevents isolation of regions of interest with lower signals. Previous studies have reported on the issue of resolving a wide range of differing iron concentration. A small focused field of view (FOV), to exclude high sources of nearby signal cannot be performed with the standard reconstruction algorithm equipped on the MomentumTM MPI scanner because it is assumed that there is no signal at the edge of the FOV and these values are set to zero for each line along the transmit axis. However, when there is signal at the FOV edge, an inverted negative artifact is created. The multichannel joint reconstruction method uses an iterative reconstruction technique to recover edge information using information from an orthogonal axis, preventing this artifact and allowing the user to prescribe a small FOV on the region of interest. Here we describe the implementation of this method to isolate and quantify low regions of MPI signal from higher regions.
- Top Cited Papers
- 1 April 2013
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 229, 116-126
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
- 1 April 2013
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 229, 116-126
Top Cited PapersMagnetic Particle Imaging (MPI) for NMR and MRI researchers
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
A 7 T/M 3D X-space MPI mouse and rat scanner
This prototype system has already produced high quality images with spatial resolutions very similar to the theoretically predicted resolution across mouse and rat sized FOVs. We have imaged both plastic and biological imaging phantoms, as well as ex vivo mice (not shown). Some early images are shown below in Fig. 1b-c. Imaging times are comparable to micro-MRI: full mouse and rat images (up to 12 cm × 5 cm × 5 cm) require between 2-5 minutes per image.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
A 7 T/M 3D X-space MPI mouse and rat scanner
This prototype system has already produced high quality images with spatial resolutions very similar to the theoretically predicted resolution across mouse and rat sized FOVs. We have imaged both plastic and biological imaging phantoms, as well as ex vivo mice (not shown). Some early images are shown below in Fig. 1b-c. Imaging times are comparable to micro-MRI: full mouse and rat images (up to 12 cm × 5 cm × 5 cm) require between 2-5 minutes per image.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Towards multidimensional x-space magnetic particle imaging for improved resolution
In this work,a method to achieve higher, more isotropic resolution for x-space MPI through analyzing various FFP trajectories and developing multidimensional transmit/receive hardware was presented. However, many parameters remain to be optimized for this technique, including the various tradeoffs between pFOV coverage, scanning speed, and resolution. Additional hardware challenges include precise control of the FFP through controlling the phase of the transmit fields and compensating for received particle signal based the anisotropic sensitivity profiles of the transmit and receive coils.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Towards multidimensional x-space magnetic particle imaging for improved resolution
In this work,a method to achieve higher, more isotropic resolution for x-space MPI through analyzing various FFP trajectories and developing multidimensional transmit/receive hardware was presented. However, many parameters remain to be optimized for this technique, including the various tradeoffs between pFOV coverage, scanning speed, and resolution. Additional hardware challenges include precise control of the FFP through controlling the phase of the transmit fields and compensating for received particle signal based the anisotropic sensitivity profiles of the transmit and receive coils.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Twenty-fold acquisition time improvement in 3D projection reconstruction MPI
Summary form only given. Magnetic Particle Imaging (MPI) commonly utilizes a Field Free Point (FFP) magnetic field gradient to localize magnetic nanoparticles [12]. With the benefits of two orders of magnitude reduced acquisition time or one order of magnitude signal-to-noise ratio (SNR) improvement, a gradient called a Field Free Line (FFL), which localizes particles to a line instead of a point, has been theoretically developed [3-6], and experimentally demonstrated [4,6]. In this work, we use a FFL with sample rotation and projection reconstruction to demonstrate experimental images with a 20 fold improvement in acquisition time compared to the first projection reconstruction (PR) MPI results [6]. To gain this 20 fold speed up, we implement a z direction focus field coil configuration instead of the previously utilized translation stage. Our imaging system included a 2.3 T/m permanent magnet FFL, a solenoidal drive coil, two focus field x and z direction electromagnet pairs with Helmholtz configurations, a solenoidal receive coil with a gradiometer configuration, and a motor driven rotary table (see Figure 1). The system drive coil was excited to create a 22.9 kHz drive field with a 1.3 cm z partial field of view (FOV). The x slow shift (focus) field operated with a 3.3 Hz triangle wave, which produced a 5 cm x FOV. A linear ramp z focus field traversed 6 cm in 3 s, once per projection image. The drive and z shift fields summed, producing a 7.3 cm z FOV. There were 20 x axis traversals (10 cycles) per projection image. With this sequence, we acquired 40 images at linearly spaced angles over 180 degrees. The image acquisition time was 2.1 min. We collected all the necessary projection data to produce a MPI tomographic 3D volume using the above parameters. Images were reconstructed using x-space reconstruction with filtered backprojection (FBP) [5-6]. The final imaging volume was limited by bore size and the z slow shift magnets to a 4.8 cm by 4.8 cm by 7.3 cm 3D volume. The 3D volume was exported in DICOM file format and subsequently imported to Osirix (Pixmeo, Switzerland) where maximum intensity projection (MIP) images were rendered. To test our imaging sytem, we have designed a phantom with a 3D distribution of magnetic nanoparticles (see Figure 1). Polyurethane tubing with inner diameter 1.6 mm (outer diameter 3.2) filled with 43 mM Fe Micromod Nanomag-D-spio was wrapped around a cylindrical piece of acrylic with a 3.4 cm outer diameter. Resulting MIP images illustrate the ability of the FFL imager to accurately resolve nanoparticle distributions in 3D. The MIP image can be rotated to any orientation, and two such views are shown in Figure 1. In previous work, an image with a similar FOV would have taken 39 min using a translation stage [6]. The two minute acquisiton time using electromagnetic z shift demonstrates an approximately 20 fold improvement in acquisition time.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Twenty-fold acquisition time improvement in 3D projection reconstruction MPI
Summary form only given. Magnetic Particle Imaging (MPI) commonly utilizes a Field Free Point (FFP) magnetic field gradient to localize magnetic nanoparticles [12]. With the benefits of two orders of magnitude reduced acquisition time or one order of magnitude signal-to-noise ratio (SNR) improvement, a gradient called a Field Free Line (FFL), which localizes particles to a line instead of a point, has been theoretically developed [3-6], and experimentally demonstrated [4,6]. In this work, we use a FFL with sample rotation and projection reconstruction to demonstrate experimental images with a 20 fold improvement in acquisition time compared to the first projection reconstruction (PR) MPI results [6]. To gain this 20 fold speed up, we implement a z direction focus field coil configuration instead of the previously utilized translation stage. Our imaging system included a 2.3 T/m permanent magnet FFL, a solenoidal drive coil, two focus field x and z direction electromagnet pairs with Helmholtz configurations, a solenoidal receive coil with a gradiometer configuration, and a motor driven rotary table (see Figure 1). The system drive coil was excited to create a 22.9 kHz drive field with a 1.3 cm z partial field of view (FOV). The x slow shift (focus) field operated with a 3.3 Hz triangle wave, which produced a 5 cm x FOV. A linear ramp z focus field traversed 6 cm in 3 s, once per projection image. The drive and z shift fields summed, producing a 7.3 cm z FOV. There were 20 x axis traversals (10 cycles) per projection image. With this sequence, we acquired 40 images at linearly spaced angles over 180 degrees. The image acquisition time was 2.1 min. We collected all the necessary projection data to produce a MPI tomographic 3D volume using the above parameters. Images were reconstructed using x-space reconstruction with filtered backprojection (FBP) [5-6]. The final imaging volume was limited by bore size and the z slow shift magnets to a 4.8 cm by 4.8 cm by 7.3 cm 3D volume. The 3D volume was exported in DICOM file format and subsequently imported to Osirix (Pixmeo, Switzerland) where maximum intensity projection (MIP) images were rendered. To test our imaging sytem, we have designed a phantom with a 3D distribution of magnetic nanoparticles (see Figure 1). Polyurethane tubing with inner diameter 1.6 mm (outer diameter 3.2) filled with 43 mM Fe Micromod Nanomag-D-spio was wrapped around a cylindrical piece of acrylic with a 3.4 cm outer diameter. Resulting MIP images illustrate the ability of the FFL imager to accurately resolve nanoparticle distributions in 3D. The MIP image can be rotated to any orientation, and two such views are shown in Figure 1. In previous work, an image with a similar FOV would have taken 39 min using a translation stage [6]. The two minute acquisiton time using electromagnetic z shift demonstrates an approximately 20 fold improvement in acquisition time.
- 1 January 2013
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 58 (6) , 565-576
Twenty-fold acceleration of 3D projection reconstruction MPI
We experimentally demonstrate a 20-fold improvement in acquisition time in projection reconstruction (PR) magnetic particle imaging (MPI) relative to the state-of-the-art PR MPI imaging results. We achieve this acceleration in our imaging system by introducing an additional Helmholtz electromagnet pair, which creates a slow shift (focus) field. Because of magnetostimulation limits in humans, we show that scan time with three-dimensional (3D) PR MPI is theoretically within the same order of magnitude as 3D MPI with a field free point; however, PR MPI has an order of magnitude signal-to-noise ratio gain.
- 1 January 2013
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 58 (6) , 565-576
Twenty-fold acceleration of 3D projection reconstruction MPI
We experimentally demonstrate a 20-fold improvement in acquisition time in projection reconstruction (PR) magnetic particle imaging (MPI) relative to the state-of-the-art PR MPI imaging results. We achieve this acceleration in our imaging system by introducing an additional Helmholtz electromagnet pair, which creates a slow shift (focus) field. Because of magnetostimulation limits in humans, we show that scan time with three-dimensional (3D) PR MPI is theoretically within the same order of magnitude as 3D MPI with a field free point; however, PR MPI has an order of magnitude signal-to-noise ratio gain.
- 16 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 32 (2) , 338-347
Projection Reconstruction Magnetic Particle Imaging
We acquire the first experimental 3-D tomographic images with magnetic particle imaging (MPI) using projection reconstruction methodology, which is similar to algorithms employed in X-ray computed tomography. The primary advantage of projection reconstruction methods is an order of magnitude increase in signal-to-noise ratio (SNR) due to averaging. We first derive the point spread function, resolution, number of projections required, and the SNR gain in projection reconstruction MPI. We then design and construct the first scanner capable of gathering the necessary data for nonaliased projection reconstruction and experimentally verify our mathematical predictions. We demonstrate that filtered backprojection in MPI is experimentally feasible and illustrate the SNR and resolution improvements with projection reconstruction. Finally, we show that MPI is capable of producing three dimensional imaging volumes in both phantoms and postmortem mice.
- 16 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 32 (2) , 338-347
Projection Reconstruction Magnetic Particle Imaging
We acquire the first experimental 3-D tomographic images with magnetic particle imaging (MPI) using projection reconstruction methodology, which is similar to algorithms employed in X-ray computed tomography. The primary advantage of projection reconstruction methods is an order of magnitude increase in signal-to-noise ratio (SNR) due to averaging. We first derive the point spread function, resolution, number of projections required, and the SNR gain in projection reconstruction MPI. We then design and construct the first scanner capable of gathering the necessary data for nonaliased projection reconstruction and experimentally verify our mathematical predictions. We demonstrate that filtered backprojection in MPI is experimentally feasible and illustrate the SNR and resolution improvements with projection reconstruction. Finally, we show that MPI is capable of producing three dimensional imaging volumes in both phantoms and postmortem mice.
- Top Cited Papers
- 3 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 31 (5) , 1076-1085
Projection X-Space Magnetic Particle Imaging
Projection magnetic particle imaging (MPI) can improve imaging speed by over 100-fold over traditional 3-D MPI. In this work, we derive the 2-D x-space signal equation, 2-D image equation, and introduce the concept of signal fading and resolution loss for a projection MPI imager. We then describe the design and construction of an x-space projection MPI scanner with a field gradient of 2.35 T/m across a 10 cm magnet free bore. The system has an expected resolution of 3.5 × 8.0 mm using Resovist tracer, and an experimental resolution of 3.8 × 8.4 mm resolution. The system images 2.5 cm × 5.0 cm partial field-of views (FOVs) at 10 frames/s, and acquires a full field-of-view of 10 cm × 5.0 cm in 4 s. We conclude by imaging a resolution phantom, a complex “Cal” phantom, mice injected with Resovist tracer, and experimentally confirm the theoretically predicted x-space spatial resolution.
- 3 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 31 (5) , 1076-1085
Top Cited PapersProjection X-Space Magnetic Particle Imaging
Projection magnetic particle imaging (MPI) can improve imaging speed by over 100-fold over traditional 3-D MPI. In this work, we derive the 2-D x-space signal equation, 2-D image equation, and introduce the concept of signal fading and resolution loss for a projection MPI imager. We then describe the design and construction of an x-space projection MPI scanner with a field gradient of 2.35 T/m across a 10 cm magnet free bore. The system has an expected resolution of 3.5 × 8.0 mm using Resovist tracer, and an experimental resolution of 3.8 × 8.4 mm resolution. The system images 2.5 cm × 5.0 cm partial field-of views (FOVs) at 10 frames/s, and acquires a full field-of-view of 10 cm × 5.0 cm in 4 s. We conclude by imaging a resolution phantom, a complex “Cal” phantom, mice injected with Resovist tracer, and experimentally confirm the theoretically predicted x-space spatial resolution.