Martin Necas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Martin Necas has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Kara Prout
Ultrasound Department Waikato Hospital Hamilton New Zealand
4 shared publications - Nicole Curtis
Department of Ultrasound Radiology Waikato Hospital Pembroke Street Hamilton 3204 New Zealand
3 shared publications - Wendy Wackrow
Ultrasound Department Waikato Hospital Hamilton New Zealand
3 shared publications - Danielle Mourits
Health New Zealand | Te Whatu Ora, Waikato, Department of Ultrasound, Level 1, Reception D Mead Clinical Centre, Waikato Hospital Hamilton New Zealand
2 shared publications - Elizabeth Lewis
Ultrasound Department Waikato Hospital Hamilton New Zealand
2 shared publications - Emma Manunui
Ultrasound Department Waikato Hospital Hamilton New Zealand
2 shared publications
Latest Publications
- Open Access
- 23 March 2026
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (3) , 281-290
Complaints Involving Sonographers: What Three Decades of Cases From A Public New Zealand Database Can Teach Us
Introduction: Sonographers are health providers who perform highly complex psychomotor, cognitive, interpretive and reporting tasks, all of which carry a risk of error. Such errors may lead to health consumer complaints. The purpose of this review was to analyse all published complaints from the Health and Disability Commissioner (HDC) database. Method: The HDC case database was searched for all cases including the term ‘sonographer’. The cases were extracted, tabulated and analysed. Results: Fifty‐three cases contained the term ‘sonographer’, but the sonographer was under investigation in only 15 cases. The majority of cases involved sonographers working in the private sector. The HDC raised concerns regarding the sonographer's practice in nine of the fifteen cases (60%). The most common issue was an undetected congenital foetal anomaly. Six cases revolved around the sonographer performing a suboptimal examination that did not adhere to accepted guidelines. The sonographers' response to complaints was characterised by acceptance of responsibility, sadness, regret and apology in all but one case. Conclusions: Complaints involving sonographers in New Zealand are rare, totalling 15 in the last 31 years and averaging 1.5 per cases per year over the last decade. In clinical settings where radiologists are reporting on the work performed by the sonographer, both the radiologist and the sonographer share collective responsibility for the content of the report.
- 23 March 2026
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (3) , 281-290
Open AccessComplaints Involving Sonographers: What Three Decades of Cases From A Public New Zealand Database Can Teach Us
Introduction: Sonographers are health providers who perform highly complex psychomotor, cognitive, interpretive and reporting tasks, all of which carry a risk of error. Such errors may lead to health consumer complaints. The purpose of this review was to analyse all published complaints from the Health and Disability Commissioner (HDC) database. Method: The HDC case database was searched for all cases including the term ‘sonographer’. The cases were extracted, tabulated and analysed. Results: Fifty‐three cases contained the term ‘sonographer’, but the sonographer was under investigation in only 15 cases. The majority of cases involved sonographers working in the private sector. The HDC raised concerns regarding the sonographer's practice in nine of the fifteen cases (60%). The most common issue was an undetected congenital foetal anomaly. Six cases revolved around the sonographer performing a suboptimal examination that did not adhere to accepted guidelines. The sonographers' response to complaints was characterised by acceptance of responsibility, sadness, regret and apology in all but one case. Conclusions: Complaints involving sonographers in New Zealand are rare, totalling 15 in the last 31 years and averaging 1.5 per cases per year over the last decade. In clinical settings where radiologists are reporting on the work performed by the sonographer, both the radiologist and the sonographer share collective responsibility for the content of the report.
- Open Access
- 11 March 2026
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (3) , 259-262
Diagnostic Performance of Ultrasound in Adult Appendicitis. A Retrospective Review of 331 Cases
Introduction: Definitive and accurate diagnosis of acute appendicitis is essential to reduce morbidity, yet ultrasound demonstrates variable performance which has generally improved over time with advancing technology and user expertise. This study aimed to evaluate the diagnostic accuracy of ultrasound for appendicitis in adults in our institution and document alternative diagnoses detected. Methods: We conducted a retrospective review of all abdominal ultrasound examinations performed between January 2021 and December 2021 for patients ≥ 16 years where appendicitis was a clinical query. Reports were categorised as positive or negative based on standardised interpretive phrases. Clinical records, operative findings, histology and follow‐up determined true outcomes. Inconclusive examinations (non‐visualised appendix) were classified as negative for analysis. Results: The cohort comprised 331 patients (92% female; mean age 28 years). Appendicitis prevalence was 16% (53/331). For the detection of appendicitis, ultrasound demonstrated sensitivity of 60%, specificity 98%, PPV 82% and NPV 93%. Alternative diagnoses ( n = 108) were more frequent than appendicitis by 2:1 and included haemorrhagic ovarian events, hydrosalpinx, mesenteric adenitis and other gynaecological or abdominal pathologies. Conclusions: Ultrasound demonstrated modest sensitivity but high specificity for diagnosing appendicitis in adults, consistent with international data when inconclusive cases are included. This shows that in the absence of any ultrasound features, appendicitis is unlikely. Alternative findings were twice as common as appendicitis, highlighting the value of ultrasound as a primary imaging modality for the assessment of patients with right lower quadrant pain.
- 11 March 2026
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (3) , 259-262
Open AccessDiagnostic Performance of Ultrasound in Adult Appendicitis. A Retrospective Review of 331 Cases
Introduction: Definitive and accurate diagnosis of acute appendicitis is essential to reduce morbidity, yet ultrasound demonstrates variable performance which has generally improved over time with advancing technology and user expertise. This study aimed to evaluate the diagnostic accuracy of ultrasound for appendicitis in adults in our institution and document alternative diagnoses detected. Methods: We conducted a retrospective review of all abdominal ultrasound examinations performed between January 2021 and December 2021 for patients ≥ 16 years where appendicitis was a clinical query. Reports were categorised as positive or negative based on standardised interpretive phrases. Clinical records, operative findings, histology and follow‐up determined true outcomes. Inconclusive examinations (non‐visualised appendix) were classified as negative for analysis. Results: The cohort comprised 331 patients (92% female; mean age 28 years). Appendicitis prevalence was 16% (53/331). For the detection of appendicitis, ultrasound demonstrated sensitivity of 60%, specificity 98%, PPV 82% and NPV 93%. Alternative diagnoses ( n = 108) were more frequent than appendicitis by 2:1 and included haemorrhagic ovarian events, hydrosalpinx, mesenteric adenitis and other gynaecological or abdominal pathologies. Conclusions: Ultrasound demonstrated modest sensitivity but high specificity for diagnosing appendicitis in adults, consistent with international data when inconclusive cases are included. This shows that in the absence of any ultrasound features, appendicitis is unlikely. Alternative findings were twice as common as appendicitis, highlighting the value of ultrasound as a primary imaging modality for the assessment of patients with right lower quadrant pain.
- 16 December 2025
- Published by Wiley in Sonography
- Vol. 13 (1)
Ultrasound Assessment for Chronic Venous Insufficiency: Introducing an Evidence‐Based Clinical Guideline for Sonographers
Chronic venous disease (CVD) is a prevalent vascular disease. Duplex ultrasound (US) is considered the first‐choice imaging modality for evaluating venous anatomy and hemodynamics in patients with CVD. In Australia and New Zealand, chronic venous insufficiency (CVI), often referred to as venous insufficiency (VI) scans, is primarily performed by medical sonographers. Currently, inconsistency in the performance and reporting of CVI ultrasound presents a challenge, and a practical solution to this dilemma is a clinical guideline to assist sonographers in making appropriate, consistent, and evidence‐based decisions throughout the scanning and reporting process. The aim of this article is to introduce a new guideline for sonographers on how to perform duplex US assessment for CVD, to provide a brief overview of its development and the methodology used, to explain its contents, and outline how it can be effectively used clinically to promote standardized practices and maintain the integrity of duplex US examinations. This guideline fills a critical gap by offering clear, evidence‐informed recommendations and general guidance on scanning techniques, interpretation, and reporting of sonographic findings.
- 16 December 2025
- Published by Wiley in Sonography
- Vol. 13 (1)
Ultrasound Assessment for Chronic Venous Insufficiency: Introducing an Evidence‐Based Clinical Guideline for Sonographers
Chronic venous disease (CVD) is a prevalent vascular disease. Duplex ultrasound (US) is considered the first‐choice imaging modality for evaluating venous anatomy and hemodynamics in patients with CVD. In Australia and New Zealand, chronic venous insufficiency (CVI), often referred to as venous insufficiency (VI) scans, is primarily performed by medical sonographers. Currently, inconsistency in the performance and reporting of CVI ultrasound presents a challenge, and a practical solution to this dilemma is a clinical guideline to assist sonographers in making appropriate, consistent, and evidence‐based decisions throughout the scanning and reporting process. The aim of this article is to introduce a new guideline for sonographers on how to perform duplex US assessment for CVD, to provide a brief overview of its development and the methodology used, to explain its contents, and outline how it can be effectively used clinically to promote standardized practices and maintain the integrity of duplex US examinations. This guideline fills a critical gap by offering clear, evidence‐informed recommendations and general guidance on scanning techniques, interpretation, and reporting of sonographic findings.
- 21 May 2025
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 28 (2) , e70009
Comparison of Carotid Artery Peak Systolic Velocity Measurement Guided by 2‐Dimensional Versus 3‐Dimensional X‐Plane Colour Doppler Ultrasound
Introduction: Characterisation of carotid artery stenosis by Doppler ultrasound relies on peak systolic velocity (PSV) measurements and velocity ratios. The site of PSV sampling is conventionally guided by 2‐dimensional (2D) colour Doppler in the longitudinal plane only. The recently introduced Philips eXL14‐3 MHz matrix array transducer (Philips Ultrasound, Bothell, WA, USA) allows visualisation of colour Doppler in longitudinal and transverse planes simultaneously (3D). We compared PSV measurements of the mid common carotid artery (mCCA) obtained using conventional 2D guidance versus 3D ultrasound guidance in a series of 100 carotid arteries.Method: This was a single centre prospective study of 100 mCCA velocity measurements. All ultrasound examinations were performed by a single qualified vascular sonographer. 2D‐guided and 3D‐guided PSV measurements were made. Sample volume adjustments made by the sonographer were recorded.Results: The average difference in PSV across the 100 sample sets was 0.3 ± 5.9 SD cms−1. Comparing 3D versus 2D guided measurements, 45 samples showed an increase in PSV measurement, with an average of 5.0 cms−1; 51 samples showed a decrease in PSV, with an average of −3.8 cms−1 and 4 samples did not show any change. The fitted T‐ and normal distribution coefficients for the 2D and 3D samples for both the PSV and TAPV were equivalent. The F‐tests of the horizontal and vertical adjustments of sample volume in 3D indicate there is little to no relationship between sample gate adjustment and resultant velocity measurements.Conclusion: No significant difference was observed in PSV measurements of the mCCA when using 3D versus conventional 2D ultrasound guidance.
- 21 May 2025
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 28 (2) , e70009
Comparison of Carotid Artery Peak Systolic Velocity Measurement Guided by 2‐Dimensional Versus 3‐Dimensional X‐Plane Colour Doppler Ultrasound
Introduction: Characterisation of carotid artery stenosis by Doppler ultrasound relies on peak systolic velocity (PSV) measurements and velocity ratios. The site of PSV sampling is conventionally guided by 2‐dimensional (2D) colour Doppler in the longitudinal plane only. The recently introduced Philips eXL14‐3 MHz matrix array transducer (Philips Ultrasound, Bothell, WA, USA) allows visualisation of colour Doppler in longitudinal and transverse planes simultaneously (3D). We compared PSV measurements of the mid common carotid artery (mCCA) obtained using conventional 2D guidance versus 3D ultrasound guidance in a series of 100 carotid arteries.Method: This was a single centre prospective study of 100 mCCA velocity measurements. All ultrasound examinations were performed by a single qualified vascular sonographer. 2D‐guided and 3D‐guided PSV measurements were made. Sample volume adjustments made by the sonographer were recorded.Results: The average difference in PSV across the 100 sample sets was 0.3 ± 5.9 SD cms−1. Comparing 3D versus 2D guided measurements, 45 samples showed an increase in PSV measurement, with an average of 5.0 cms−1; 51 samples showed a decrease in PSV, with an average of −3.8 cms−1 and 4 samples did not show any change. The fitted T‐ and normal distribution coefficients for the 2D and 3D samples for both the PSV and TAPV were equivalent. The F‐tests of the horizontal and vertical adjustments of sample volume in 3D indicate there is little to no relationship between sample gate adjustment and resultant velocity measurements.Conclusion: No significant difference was observed in PSV measurements of the mCCA when using 3D versus conventional 2D ultrasound guidance.
- 24 February 2025
- Published by Wiley in Sonography
- Vol. 12 (2) , 198-204
The Accuracy of Sonographers' Reports in a High‐Risk Obstetric Service: Is the Input of Radiologists Necessary?
Introduction: Sonographers demonstrate high accuracy in the interpretation and independent reporting of diagnostic ultrasound examinations. This raises important questions about whether sonographers need to be routinely supervised by radiologists. The aim of this study was to compare obstetric reports independently issued by sonographers with final reports issued by radiologists in a large tertiary teaching hospital.Methods: This study was a retrospective sequential review of obstetric ultrasound reports on high‐risk antenatal clinic patients and obstetric inpatients between 19 August 2024 and 11 October 2024. Sonographers performed the required examinations and independently issued their reports directly to clinicians. At a later time, radiologists reviewed the sonographers' reports and authorised final reports. Any differences between the sonographers' and radiologists' reports were analyzed.Results: Of the 650 reports issued by sonographers, 269 (41%) contained abnormal findings, most commonly abnormal growth, fluid volume, or Doppler parameters. Radiologists agreed with the sonographers' clinical interpretation in 649(99.8%) of cases. Radiologists detected no single error in the sonographers' interpretation of fetal viability, growth, amniotic fluid, Doppler parameters, fetal abnormalities, utero‐placental abnormalities, or adnexal abnormality. The involvement of radiologists in the verification/authorization of sonographers' reports resulted in the introduction of one new interpretive error and 13 new interpretive discrepancies. Sonographers committed a small number of spelling (12), transcription (7), wrong word errors (2) and one wrong patient error (1). Radiologists did not detect the majority of these errors.Conclusion: Independent reporting of obstetric ultrasound examinations by sonographers is safe and effective. We recommend that sonographers authorize obstetric reports independently.
- 24 February 2025
- Published by Wiley in Sonography
- Vol. 12 (2) , 198-204
The Accuracy of Sonographers' Reports in a High‐Risk Obstetric Service: Is the Input of Radiologists Necessary?
Introduction: Sonographers demonstrate high accuracy in the interpretation and independent reporting of diagnostic ultrasound examinations. This raises important questions about whether sonographers need to be routinely supervised by radiologists. The aim of this study was to compare obstetric reports independently issued by sonographers with final reports issued by radiologists in a large tertiary teaching hospital.Methods: This study was a retrospective sequential review of obstetric ultrasound reports on high‐risk antenatal clinic patients and obstetric inpatients between 19 August 2024 and 11 October 2024. Sonographers performed the required examinations and independently issued their reports directly to clinicians. At a later time, radiologists reviewed the sonographers' reports and authorised final reports. Any differences between the sonographers' and radiologists' reports were analyzed.Results: Of the 650 reports issued by sonographers, 269 (41%) contained abnormal findings, most commonly abnormal growth, fluid volume, or Doppler parameters. Radiologists agreed with the sonographers' clinical interpretation in 649(99.8%) of cases. Radiologists detected no single error in the sonographers' interpretation of fetal viability, growth, amniotic fluid, Doppler parameters, fetal abnormalities, utero‐placental abnormalities, or adnexal abnormality. The involvement of radiologists in the verification/authorization of sonographers' reports resulted in the introduction of one new interpretive error and 13 new interpretive discrepancies. Sonographers committed a small number of spelling (12), transcription (7), wrong word errors (2) and one wrong patient error (1). Radiologists did not detect the majority of these errors.Conclusion: Independent reporting of obstetric ultrasound examinations by sonographers is safe and effective. We recommend that sonographers authorize obstetric reports independently.
- 30 September 2024
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 28 (1) , e12406
Klebsiella liver phlegmon mimicking a solid liver tumour
Introduction: This case examines the sonographic and clinical challenge of diagnosing a Klebsiella pnumoniae pyogenic liver abscess with systemic metastatic infection.Case Description: The patient in this case study is an 81‐year‐old man who presented with intermittent rigors. Following radiological and clinical assessments, a Klebsiella pnumoniae pyogenic liver abscess, with evidence of systemic metastatic infection, was diagnosed. Sonographic features of the liver abscess were atypical for a cystic lesion and instead appeared as a solid mass, raising the possibility of malignancy. Treatment of intravenous ceftriaxone infusions resulted in full resolution of the liver lesion.Discussion: The discussion criticises the terminology when describing hepatic lesions, which result from a Klebsiella pnumoniae infection. The term hepatic phlegmon is appropriate when a liver lesion caused by bacterial infection demonstrates a solid appearance on radiologic imaging. The term hepatic abscess is appropriate in cases where liver lesions caused by bacterial infection demonstrate a fluid filled core on radiologic imaging. Differentiation of these terms is important when treating the underlying lesion as a phlegmon, in contrast to an abscess, cannot be drained because it contains no pus. The variable sonographic appearances of Klebsiella pnumoniae pyogenic abscesses were also examined. Despite reported sonographic appearances in the literature, none are sufficient to distinguish a pyogenic liver abscess from malignancy without further investigation.Conclusion: Ultrasound operators should be aware of the variable sonographic appearances of a Klebsiella pnumoniae liver abscess and how these features, combined with non‐homogenous terminology, can obfuscate the correct diagnosis.
- 30 September 2024
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 28 (1) , e12406
Klebsiella liver phlegmon mimicking a solid liver tumour
Introduction: This case examines the sonographic and clinical challenge of diagnosing a Klebsiella pnumoniae pyogenic liver abscess with systemic metastatic infection.Case Description: The patient in this case study is an 81‐year‐old man who presented with intermittent rigors. Following radiological and clinical assessments, a Klebsiella pnumoniae pyogenic liver abscess, with evidence of systemic metastatic infection, was diagnosed. Sonographic features of the liver abscess were atypical for a cystic lesion and instead appeared as a solid mass, raising the possibility of malignancy. Treatment of intravenous ceftriaxone infusions resulted in full resolution of the liver lesion.Discussion: The discussion criticises the terminology when describing hepatic lesions, which result from a Klebsiella pnumoniae infection. The term hepatic phlegmon is appropriate when a liver lesion caused by bacterial infection demonstrates a solid appearance on radiologic imaging. The term hepatic abscess is appropriate in cases where liver lesions caused by bacterial infection demonstrate a fluid filled core on radiologic imaging. Differentiation of these terms is important when treating the underlying lesion as a phlegmon, in contrast to an abscess, cannot be drained because it contains no pus. The variable sonographic appearances of Klebsiella pnumoniae pyogenic abscesses were also examined. Despite reported sonographic appearances in the literature, none are sufficient to distinguish a pyogenic liver abscess from malignancy without further investigation.Conclusion: Ultrasound operators should be aware of the variable sonographic appearances of a Klebsiella pnumoniae liver abscess and how these features, combined with non‐homogenous terminology, can obfuscate the correct diagnosis.
- 25 December 2023
- Published by Wiley in Sonography
- Vol. 11 (2) , 136-138
Hypoechoic liver in a fetus with trisomy 21 but without transient abnormal myelopoiesis at birth
- 25 December 2023
- Published by Wiley in Sonography
- Vol. 11 (2) , 136-138
Hypoechoic liver in a fetus with trisomy 21 but without transient abnormal myelopoiesis at birth
- 21 June 2023
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 26 (3) , 191-198
Transient intussusception – What the sonographer needs to know
Intussusception is typically considered an acute emergency; however, the increased utilisation of medical imaging has revealed that intussusceptions can also be transient, asymptomatic and possibly physiologic. Sonographers should be aware of three categories of intussusceptions: (i) persistent intussusceptions resulting in acute abdomen and requiring urgent intervention, (ii) transient symptomatic intussusceptions which may be amenable to a ‘wait‐and‐see’ strategy and (iii) transient asymptomatic intussusceptions which almost always involve the small bowel. In particular, the incidental discovery of enteroenteric intussusceptions in children should not be confused with acute pathology. In adults, sonographers should be mindful of the frequent presence of pathological lead points and further investigations may be warranted. In this literature review, we provide an overview of transient intussusceptions, highlight important differences between children and adults and describe sonographic appearances of various intussusceptions and their mimics.
- 21 June 2023
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 26 (3) , 191-198
Transient intussusception – What the sonographer needs to know
Intussusception is typically considered an acute emergency; however, the increased utilisation of medical imaging has revealed that intussusceptions can also be transient, asymptomatic and possibly physiologic. Sonographers should be aware of three categories of intussusceptions: (i) persistent intussusceptions resulting in acute abdomen and requiring urgent intervention, (ii) transient symptomatic intussusceptions which may be amenable to a ‘wait‐and‐see’ strategy and (iii) transient asymptomatic intussusceptions which almost always involve the small bowel. In particular, the incidental discovery of enteroenteric intussusceptions in children should not be confused with acute pathology. In adults, sonographers should be mindful of the frequent presence of pathological lead points and further investigations may be warranted. In this literature review, we provide an overview of transient intussusceptions, highlight important differences between children and adults and describe sonographic appearances of various intussusceptions and their mimics.
- 6 March 2023
- Published by Wiley in Sonography
- Vol. 10 (2) , 57-65
The accuracy of sonographers in reporting abnormal ultrasound findings: A prospective study comparing sonographers' and radiologists' reports in 1000 hospital patients
Introduction: The aim of this study was to compare the ultrasound (US) findings independently reported by sonographers with final reports issued by radiologists in a complex working environment of an acute and inpatient US service in a large tertiary teaching hospital.Methods: This study was a prospective review of 1000 unique hospital patients who received 1142 US examinations. Sonographers performed the requested examinations and reported their findings independently before consulting with radiologists. Radiologists reviewed the sonographers' findings, consulted with sonographers, and issued their final reports. Any disagreements between the findings of the sonographer and radiologist were captured, analysed and separated into errors or discrepancies according to commonly accepted definitions. Patient outcomes were determined from electronic clinical records.Results: Examinations were performed by a team of 11 sonographers with a median of 9.5 years of experience and standard US qualifications. Sonographers independently reported 1484 abnormal findings in 268 categories. Radiologists were in complete agreement in 93.6% of cases, 5.3% cases included minor discrepancies and 1.1% of cases contained errors of which sonographers were responsible for 9 and radiologists 7. The severity of errors was comparable between sonographers and radiologists.Conclusion: Sonographers and radiologists demonstrate a high degree of agreement in reporting abnormal US findings. Sonographers and radiologists committed a comparable number of errors, and the error severity scores were also comparable. The customary, routine involvement of a radiologist in the second reading and reporting of all US examinations is unnecessary.
- 6 March 2023
- Published by Wiley in Sonography
- Vol. 10 (2) , 57-65
The accuracy of sonographers in reporting abnormal ultrasound findings: A prospective study comparing sonographers' and radiologists' reports in 1000 hospital patients
Introduction: The aim of this study was to compare the ultrasound (US) findings independently reported by sonographers with final reports issued by radiologists in a complex working environment of an acute and inpatient US service in a large tertiary teaching hospital.Methods: This study was a prospective review of 1000 unique hospital patients who received 1142 US examinations. Sonographers performed the requested examinations and reported their findings independently before consulting with radiologists. Radiologists reviewed the sonographers' findings, consulted with sonographers, and issued their final reports. Any disagreements between the findings of the sonographer and radiologist were captured, analysed and separated into errors or discrepancies according to commonly accepted definitions. Patient outcomes were determined from electronic clinical records.Results: Examinations were performed by a team of 11 sonographers with a median of 9.5 years of experience and standard US qualifications. Sonographers independently reported 1484 abnormal findings in 268 categories. Radiologists were in complete agreement in 93.6% of cases, 5.3% cases included minor discrepancies and 1.1% of cases contained errors of which sonographers were responsible for 9 and radiologists 7. The severity of errors was comparable between sonographers and radiologists.Conclusion: Sonographers and radiologists demonstrate a high degree of agreement in reporting abnormal US findings. Sonographers and radiologists committed a comparable number of errors, and the error severity scores were also comparable. The customary, routine involvement of a radiologist in the second reading and reporting of all US examinations is unnecessary.
- Open Access
- 1 March 2022
- Published by Wiley in Sonography
- Vol. 9 (1) , 3-6
Routine disclosure statements about ultrasound examinations during Covid-19 pandemic are unhelpful and should be avoided COMMENT
- 1 March 2022
- Published by Wiley in Sonography
- Vol. 9 (1) , 3-6
Open AccessRoutine disclosure statements about ultrasound examinations during Covid-19 pandemic are unhelpful and should be avoided COMMENT