Erik Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Erik Su has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Aliaksei Pustavoitau
Department of Anesthesiology and Critical Care Medicine, Johns Hopkins School of Medicine, Baltimore, MD, USA
4 shared publications Bereketeab Haileselassie
Division of Critical Care Medicine, Department of Pediatrics, Stanford University School of Medicine, Stanford, CA
3 shared publicationsSarah Ginsburg
Division of Pediatric Critical Care Medicine, University of Texas Southwestern, Dallas, TX
3 shared publicationsAhmed Veten
Division of Pediatric Critical Care Medicine, Department of Pediatrics, Yale School of Medicine, New Haven, CT
2 shared publicationsAkira Nishisaki
Department of Anesthesiology and Critical Care Medicine, Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA
2 shared publicationsBoran Li
Divisions of Pediatric Critical Care and Cardiology, Department of Pediatrics, Mount Sinai Hospital, New York, NY
2 shared publications
Latest Publications
- 4 November 2026
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
Peripheral IV Catheter Longevity With Ultrasound Guidance in the PICU: Single-Center Retrospective Cohort, 2016–2018
OBJECTIVES: To compare associated outcomes between ultrasound-guided peripheral IV catheter (USGPIV) insertion and device longevity in critically ill children. DESIGN: Retrospective observational cohort study. SETTING: Tertiary medical-surgical pediatric PICU with cardiac patients. PATIENTS: Patients admitted to the PICU requiring peripheral vascular access between January 1, 2016, and October 1, 2018. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We identified patients who underwent USGPIV and landmark-guided peripheral IV catheters (LMGPIV) placed within 2 weeks of a USGPIV, and made comparisons between the procedures. There were 507 USGPIV and 292 LMGPIV placements. Of these, 334 USGPIV and 278 LMGPIV had longevity data. Log-rank analysis with median (interquartile range, IQR) data showed an associated greater catheter longevity in USGPIVs vs. LMGPIVs, respectively: 5 days (IQR, 2–9 d) vs. 3 days (IQR, 1–4 d), p value of less than 0.001. When restricted to either patients admitted with cardiac disease or those with known difficult vascular access, the association between USGPIVs and LMGPIVs and greater longevity remained, respectively: cardiac cases, 5 days (IQR, 2–9 d) vs. 3 days (IQR, 2–6 d); p = 0.038 and difficult access, 5 days (IQR, 2–9 d) vs. 2 days (IQR, 1–4 d), p value of less than 0.001. CONCLUSIONS: In this single-center experience of using USGPIV placement over 28 months (2016–2018), USGPIV placement was associated with greater catheter longevity. These findings suggest that USGPIV placement is potentially a means for improving PIV insertion and maintenance.
- 4 November 2026
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
Peripheral IV Catheter Longevity With Ultrasound Guidance in the PICU: Single-Center Retrospective Cohort, 2016–2018
OBJECTIVES: To compare associated outcomes between ultrasound-guided peripheral IV catheter (USGPIV) insertion and device longevity in critically ill children. DESIGN: Retrospective observational cohort study. SETTING: Tertiary medical-surgical pediatric PICU with cardiac patients. PATIENTS: Patients admitted to the PICU requiring peripheral vascular access between January 1, 2016, and October 1, 2018. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We identified patients who underwent USGPIV and landmark-guided peripheral IV catheters (LMGPIV) placed within 2 weeks of a USGPIV, and made comparisons between the procedures. There were 507 USGPIV and 292 LMGPIV placements. Of these, 334 USGPIV and 278 LMGPIV had longevity data. Log-rank analysis with median (interquartile range, IQR) data showed an associated greater catheter longevity in USGPIVs vs. LMGPIVs, respectively: 5 days (IQR, 2–9 d) vs. 3 days (IQR, 1–4 d), p value of less than 0.001. When restricted to either patients admitted with cardiac disease or those with known difficult vascular access, the association between USGPIVs and LMGPIVs and greater longevity remained, respectively: cardiac cases, 5 days (IQR, 2–9 d) vs. 3 days (IQR, 2–6 d); p = 0.038 and difficult access, 5 days (IQR, 2–9 d) vs. 2 days (IQR, 1–4 d), p value of less than 0.001. CONCLUSIONS: In this single-center experience of using USGPIV placement over 28 months (2016–2018), USGPIV placement was associated with greater catheter longevity. These findings suggest that USGPIV placement is potentially a means for improving PIV insertion and maintenance.
- 5 February 2026
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 27 (2) , 228-234
Good Practice Concepts in Pediatric Critical Care Point-of-Care Ultrasound: A Modified Delphi Consensus Initiative
OBJECTIVE: We assembled a workgroup within the Pediatric Research Collaborative on Critical UltraSound (PeRCCUS), a subgroup of the Pediatric Acute Lung Injury and Sepsis Investigators (PALISI), to define early guidance for point-of-care ultrasound (POCUS) institutional practice and foster future comprehensive guidelines for its broad adoption in pediatric critical care medicine. DESIGN: A modified Delphi method was used for creating the statements. The first meeting was an open proposal session for workgroup members to suggest items for consideration. This was followed by a cycle of voting for levels of agreement along a 7-point Likert-type scale. Items were reviewed, with only items receiving a score of greater than or equal to 6 progressing to the next stage of voting and lower-scoring items reconsidered, with only consensus items proceeding to the next stage for additional rounds of voting until consensus was reached. SETTING: Multi-institutional, multidisciplinary, workgroup of experts on POCUS organized within PeRCCUS as a subgroup of PALISI. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Consensus was obtained for 25 recommendations across five domains: clinical application, quality assurance, equipment, education, and research. CONCLUSIONS: We report consensus recommendations for institutions on clinical use, educational programs, quality assurance, technical requirements, and future research opportunities for the adoption of pediatric critical care medicine POCUS.
- 5 February 2026
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 27 (2) , 228-234
Good Practice Concepts in Pediatric Critical Care Point-of-Care Ultrasound: A Modified Delphi Consensus Initiative
OBJECTIVE: We assembled a workgroup within the Pediatric Research Collaborative on Critical UltraSound (PeRCCUS), a subgroup of the Pediatric Acute Lung Injury and Sepsis Investigators (PALISI), to define early guidance for point-of-care ultrasound (POCUS) institutional practice and foster future comprehensive guidelines for its broad adoption in pediatric critical care medicine. DESIGN: A modified Delphi method was used for creating the statements. The first meeting was an open proposal session for workgroup members to suggest items for consideration. This was followed by a cycle of voting for levels of agreement along a 7-point Likert-type scale. Items were reviewed, with only items receiving a score of greater than or equal to 6 progressing to the next stage of voting and lower-scoring items reconsidered, with only consensus items proceeding to the next stage for additional rounds of voting until consensus was reached. SETTING: Multi-institutional, multidisciplinary, workgroup of experts on POCUS organized within PeRCCUS as a subgroup of PALISI. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Consensus was obtained for 25 recommendations across five domains: clinical application, quality assurance, equipment, education, and research. CONCLUSIONS: We report consensus recommendations for institutions on clinical use, educational programs, quality assurance, technical requirements, and future research opportunities for the adoption of pediatric critical care medicine POCUS.
- 5 February 2026
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 27 (2) , 235-243
Proposing Entrustable Professional Activities for Pediatric Critical Care Ultrasound: A Modified Delphi Consensus Approach
OBJECTIVE: Develop a consensus-based framework for point-of care ultrasound in pediatric critical care, or critical care ultrasound (CCUS) education using entrustable professional activities (EPAs). DESIGN: A modified Delphi method utilizing cycles of meetings and surveys for consensus-building. SETTING: The endeavor involved members of the Pediatric Research Collaborative on Critical Ultrasound (PeRCCUS), a subgroup of the Pediatric Acute Lung Injury And Sepsis Investigators. SUBJECTS: An expert panel consisting of 23 members representing 17 institutions, including diverse healthcare professionals involved in pediatric critical care ultrasound. INTERVENTIONS: Three iterative modified Delphi rounds were conducted to propose and refine critical care ultrasound EPAs. MEASUREMENTS AND MAIN RESULTS: The endeavor achieved a 74% response rate. Fourteen EPAs were formulated across five domains: Cardiac, Pulmonary, Abdomen, Procedures, and Vascular, along with two consensus opinions on educational content and methods. EPAs were evaluated using 5-point Likert items, requiring a median score of greater than or equal to 4.5 for progression. CONCLUSIONS: This collaborative effort led to the establishment of fourteen EPAs for pediatric critical care ultrasound, offering a structured approach for education and competency assessment in pediatric critical care. This initiative lays the groundwork for evolving standards in pediatric critical care ultrasound education and practice.
- 5 February 2026
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 27 (2) , 235-243
Proposing Entrustable Professional Activities for Pediatric Critical Care Ultrasound: A Modified Delphi Consensus Approach
OBJECTIVE: Develop a consensus-based framework for point-of care ultrasound in pediatric critical care, or critical care ultrasound (CCUS) education using entrustable professional activities (EPAs). DESIGN: A modified Delphi method utilizing cycles of meetings and surveys for consensus-building. SETTING: The endeavor involved members of the Pediatric Research Collaborative on Critical Ultrasound (PeRCCUS), a subgroup of the Pediatric Acute Lung Injury And Sepsis Investigators. SUBJECTS: An expert panel consisting of 23 members representing 17 institutions, including diverse healthcare professionals involved in pediatric critical care ultrasound. INTERVENTIONS: Three iterative modified Delphi rounds were conducted to propose and refine critical care ultrasound EPAs. MEASUREMENTS AND MAIN RESULTS: The endeavor achieved a 74% response rate. Fourteen EPAs were formulated across five domains: Cardiac, Pulmonary, Abdomen, Procedures, and Vascular, along with two consensus opinions on educational content and methods. EPAs were evaluated using 5-point Likert items, requiring a median score of greater than or equal to 4.5 for progression. CONCLUSIONS: This collaborative effort led to the establishment of fourteen EPAs for pediatric critical care ultrasound, offering a structured approach for education and competency assessment in pediatric critical care. This initiative lays the groundwork for evolving standards in pediatric critical care ultrasound education and practice.
- 4 November 2024
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 25 (11) , 1065-1068
Making Waves With Point-of-Care Ultrasound; Investment Begets Impact at the ICU Bedside?*
- 4 November 2024
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 25 (11) , 1065-1068
Making Waves With Point-of-Care Ultrasound; Investment Begets Impact at the ICU Bedside?*
- 25 August 2023
- Published by Springer Nature
- p. 291-297
Use of Ultrasound in ECMO
- 25 August 2023
- Published by Springer Nature
- p. 141-147
Airway Ultrasound
- Open Access
- 28 July 2023
- Published by Texas Heart Institute Journal in Texas Heart Institute Journal
- Vol. 50 (4)
Critical Care Echocardiography for Fluid Responsiveness
Fluid management is a crucial component of acute care in the intensive care unit. Early goal-directed therapy has shown better outcomes in patients with septic shock.1 Increased end-diastolic volume and stroke volume depend on ventricular function. The accurate assessment of intravascular volume and adequate maintenance of cardiac preload can improve the outcomes of critically ill patients. Overresuscitation without fluid responsiveness may result in more harm by shifting fluid to the extravascular space and causing end-organ edema. To select patients who might benefit from volume expansion, many studies have sought bedside indicators of fluid responsiveness.Numerous hemodynamic variables have been proposed as predictors of fluid responsiveness. Static variables are based on a single observation in time, such as central venous pressure, but central venous pressure and other static measures are largely affected by intrathoracic pressures and ventricular compliance. Dynamic variables reflect the cardiovascular response to respiratory changes in pleural pressure. Respiratory changes in systolic pressure, pulse pressure, aortic blood flow peak velocity, superior vena cava diameter, and inferior vena cava (IVC) diameter have been proposed as more sensitive predictors of fluid responsiveness.2Bedside ultrasonography has emerged as a rapid, noninvasive tool for assessing and monitoring fluid status in the intensive care unit.3 With positive-pressure ventilation, the vena cava blood flow is impeded during inspiration, causing a decrease in venous return and pulmonary artery blood flow. This effect on venous return can be quantified as variation in IVC diameter, which can be measured from the subcostal view at 1 cm caudal to the confluence of hepatic veins using M-mode or a 2-dimensional view. The inferior vena cava collapsibility index can be calculated by the difference between maximum and minimum IVC diameter over a single respiratory cycle divided by the maximum IVC diameter. Respiratory variation in IVC diameter better predicts fluid responsiveness in mechanically ventilated patients but has limited ability in spontaneously breathing patients.4 Distention of the IVC to more than 12% to 18% in mechanically ventilated patients and IVC collapse of at least 40% to 50% in spontaneously breathing patients are considered predictive of fluid responsiveness.5 The reliability of IVC diameter and collapsibility should be regarded with caution, however, and the underlying physiology assessed. Inferior vena cava dilation is expected in right ventricular failure or tamponade, and fluid administration should not be contraindicated when clinically appropriate. Compression of the IVC can occur with compression from abdominal pathology, as well. Issues of accuracy have also been raised in terms of whether measurement methods alter the reliability of the test.6 Data suggest that superior vena cava imaging with transesophageal imaging may have a higher sensitivity for fluid responsiveness, which is an area for further exploration.3Respiratory variation in aorta peak velocity is a better predictor of fluid responsiveness than systolic pressure or pulse pressure variation.7–9 Unlike variables based on arterial blood pressure or plethysmographic measurements, flow measurements are not affected by arterial compliance or changes in arterial tone. Pulsed Doppler echocardiography at the aortic annulus from the apical 5-chamber view allows aortic flow velocity measurement (Fig. 1). The maximum and minimum peak aortic blood flow velocities can be measured over a single respiratory cycle. Respiratory variation in aorta velocity time integral (VTi) (Fig. 2) can be calculated by measuring the area under the Doppler envelope of blood flow in the left ventricular outflow tract in systole to estimate stroke volume, then calculating the difference between maximum and minimum aortic VTi observed over a single respiratory cycle divided by the maximum VTi. Greater than 15% variability is associated with fluid responsiveness in mechanically ventilated patients.10Because metrics based on ultrasonography have had variable results in identifying fluid responsiveness depending on the physiological factors mentioned here, the same metrics used to evaluate the need for fluid administration may also be useful to measure fluid tolerance. Such metrics are useful in arenas where fluids may be considered, and unexpected ultrasonographic findings can help steer care.10The passive leg raising test is a helpful tool to determine fluid responsiveness at bedside. Raising a patient’s legs to at least 45 degrees for 2 to 3 minutes induces a gravitational transfer of venous blood from the legs into the central circulation, which results in a transient increase in cardiac preload. Passive leg raising is completely reversible; therefore, any detrimental effects of unnecessary fluid administration are minimal and temporary.Bedside ultrasonography allows rapid and noninvasive assessment of volume status and can help predict fluid responsiveness in critically ill patients. Dynamic measurements are better predictors of fluid responsiveness than static variables. Extrinsic factors, such as intrathoracic pressure and intraabdominal pressure, can alter the anatomy. Underlying physiology should be taken into consideration for clinically appropriate interpretation of ultrasonographic findings.
- 28 July 2023
- Published by Texas Heart Institute Journal in Texas Heart Institute Journal
- Vol. 50 (4)
Open AccessCritical Care Echocardiography for Fluid Responsiveness
Fluid management is a crucial component of acute care in the intensive care unit. Early goal-directed therapy has shown better outcomes in patients with septic shock.1 Increased end-diastolic volume and stroke volume depend on ventricular function. The accurate assessment of intravascular volume and adequate maintenance of cardiac preload can improve the outcomes of critically ill patients. Overresuscitation without fluid responsiveness may result in more harm by shifting fluid to the extravascular space and causing end-organ edema. To select patients who might benefit from volume expansion, many studies have sought bedside indicators of fluid responsiveness.Numerous hemodynamic variables have been proposed as predictors of fluid responsiveness. Static variables are based on a single observation in time, such as central venous pressure, but central venous pressure and other static measures are largely affected by intrathoracic pressures and ventricular compliance. Dynamic variables reflect the cardiovascular response to respiratory changes in pleural pressure. Respiratory changes in systolic pressure, pulse pressure, aortic blood flow peak velocity, superior vena cava diameter, and inferior vena cava (IVC) diameter have been proposed as more sensitive predictors of fluid responsiveness.2Bedside ultrasonography has emerged as a rapid, noninvasive tool for assessing and monitoring fluid status in the intensive care unit.3 With positive-pressure ventilation, the vena cava blood flow is impeded during inspiration, causing a decrease in venous return and pulmonary artery blood flow. This effect on venous return can be quantified as variation in IVC diameter, which can be measured from the subcostal view at 1 cm caudal to the confluence of hepatic veins using M-mode or a 2-dimensional view. The inferior vena cava collapsibility index can be calculated by the difference between maximum and minimum IVC diameter over a single respiratory cycle divided by the maximum IVC diameter. Respiratory variation in IVC diameter better predicts fluid responsiveness in mechanically ventilated patients but has limited ability in spontaneously breathing patients.4 Distention of the IVC to more than 12% to 18% in mechanically ventilated patients and IVC collapse of at least 40% to 50% in spontaneously breathing patients are considered predictive of fluid responsiveness.5 The reliability of IVC diameter and collapsibility should be regarded with caution, however, and the underlying physiology assessed. Inferior vena cava dilation is expected in right ventricular failure or tamponade, and fluid administration should not be contraindicated when clinically appropriate. Compression of the IVC can occur with compression from abdominal pathology, as well. Issues of accuracy have also been raised in terms of whether measurement methods alter the reliability of the test.6 Data suggest that superior vena cava imaging with transesophageal imaging may have a higher sensitivity for fluid responsiveness, which is an area for further exploration.3Respiratory variation in aorta peak velocity is a better predictor of fluid responsiveness than systolic pressure or pulse pressure variation.7–9 Unlike variables based on arterial blood pressure or plethysmographic measurements, flow measurements are not affected by arterial compliance or changes in arterial tone. Pulsed Doppler echocardiography at the aortic annulus from the apical 5-chamber view allows aortic flow velocity measurement (Fig. 1). The maximum and minimum peak aortic blood flow velocities can be measured over a single respiratory cycle. Respiratory variation in aorta velocity time integral (VTi) (Fig. 2) can be calculated by measuring the area under the Doppler envelope of blood flow in the left ventricular outflow tract in systole to estimate stroke volume, then calculating the difference between maximum and minimum aortic VTi observed over a single respiratory cycle divided by the maximum VTi. Greater than 15% variability is associated with fluid responsiveness in mechanically ventilated patients.10Because metrics based on ultrasonography have had variable results in identifying fluid responsiveness depending on the physiological factors mentioned here, the same metrics used to evaluate the need for fluid administration may also be useful to measure fluid tolerance. Such metrics are useful in arenas where fluids may be considered, and unexpected ultrasonographic findings can help steer care.10The passive leg raising test is a helpful tool to determine fluid responsiveness at bedside. Raising a patient’s legs to at least 45 degrees for 2 to 3 minutes induces a gravitational transfer of venous blood from the legs into the central circulation, which results in a transient increase in cardiac preload. Passive leg raising is completely reversible; therefore, any detrimental effects of unnecessary fluid administration are minimal and temporary.Bedside ultrasonography allows rapid and noninvasive assessment of volume status and can help predict fluid responsiveness in critically ill patients. Dynamic measurements are better predictors of fluid responsiveness than static variables. Extrinsic factors, such as intrathoracic pressure and intraabdominal pressure, can alter the anatomy. Underlying physiology should be taken into consideration for clinically appropriate interpretation of ultrasonographic findings.
- 15 June 2023
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 24 (11) , e568-e572
Death and Ultrasound Evidence of the Akinetic Heart in Pediatric Cardiac Arrest
Point-of-care ultrasound (POCUS) is an expanding noninvasive diagnostic modality used for the management of patients in multiple intensive care and pediatric specialties. POCUS is used to assess cardiac activity and pathology, pulmonary disease, intravascular volume status, intra-abdominal processes, procedural guidance including vascular access, lumbar puncture, thoracentesis, paracentesis, and pericardiocentesis. POCUS has also been used to determine anterograde flow following circulatory arrest when organ donation after circulatory death is being considered. Published guidelines exist from multiple medical societies including the recent guidelines for the use of POCUS in neonatology for diagnostic and procedural purposes.
- 15 June 2023
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 24 (11) , e568-e572
Death and Ultrasound Evidence of the Akinetic Heart in Pediatric Cardiac Arrest
Point-of-care ultrasound (POCUS) is an expanding noninvasive diagnostic modality used for the management of patients in multiple intensive care and pediatric specialties. POCUS is used to assess cardiac activity and pathology, pulmonary disease, intravascular volume status, intra-abdominal processes, procedural guidance including vascular access, lumbar puncture, thoracentesis, paracentesis, and pericardiocentesis. POCUS has also been used to determine anterograde flow following circulatory arrest when organ donation after circulatory death is being considered. Published guidelines exist from multiple medical societies including the recent guidelines for the use of POCUS in neonatology for diagnostic and procedural purposes.
- Open Access
Unexpected Vascular Ultrasound Findings Prompting Hemodynamic Management in an Infant in Respiratory Failure