James Anthony Shackleford
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
James Anthony Shackleford has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Nagarajan Kandasamy
Drexel University (1970-)
4 shared publicationsPingge Jiang
3 shared publicationsGregory C. Sharp
2 shared publications- Gregory Charles Sharp
Department of Radiation Oncology, Massachusetts General Hospital
2 shared publications Gregory Sharp
Department of Radiation Oncology, Massachusetts General Hospital
2 shared publicationsHarald Paganetti
Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114
2 shared publications
Latest Publications
- 28 November 2022
- Published by Drexel University Libraries
Improving Precision of Deformable Image Registration
Deformable image registration (DIR) has various applications in medical image analysis such as in adaptive radiotherapy (ART) and multi-atlas segmentation. ART uses DIR to warp the dose from the daily cone-beam CT (CBCT) image to the planning computed tomography (CT) image to accommodate anatomical changes that occur between dose planning and dose delivery. DIR aims to find a geometric transformation between corresponding image data and brings them into a common coordinate frame. DIR is an inherently ill-posed problem that lacks a unique mapping between the voxels of the two images being registered. As such, one must regularize the registration to achieve physically meaningful transforms. The regularization penalty is usually a function of derivatives of the displacement vector field and can be calculated either analytically or numerically. The numerical approach, however, is computationally expensive depending on the image size, and therefore a computationally efficient analytical framework has been developed. Cubic B-splines were used to model the displacement vector field. A generalized mathematical framework was developed that supports five distinct regularizers: diffusion, curvature, linear elastic, third-order, and total displacement. The approach was validated by comparing each regularizer with its numerical counterpart in terms of accuracy. Benchmarking results show that the analytic solutions run significantly faster - up to two orders of magnitude - than finite differencing-based numerical implementations. Additionally, the cost function used in the DIR optimization process is a global, low-level cost function. It fails to accurately align high-level image structures such as organs at risk (OARs). DIR accuracy can be improved locally by adding high-level structures such as contours and landmark points. A hybrid image similarity metric that incorporates a point-to-distance map (PD) metric was developed. Given a pair of segmented images, structures on the fixed image are represented as sets of points while structures on the moving image are described as distance maps. The total distance of all fixed points to their associated boundaries on the moving image constitutes the PD metric, which is combined with the more traditional intensity similarity metric between the fixed and moving images. The approach was validated using the pelvic reference dataset wherein the prostate, bladder, and rectum were manually segmented from the CT and CBCT images by a medical expert to obtain the segmented fixed and moving images. The accuracy of the deformable registration was quantified using the Dice Similarity Coefficient (DSC) and 95% Hausdorff Distance (95% HD), with and without the PD metric. Results demonstrate a much-improved overlap between the fixed and warped contours once the PD metric was applied. Moreover, the computational overhead associated with adding the PD metric was minimal. Finally, to circumvent the need for a medical expert to manually segment the structures, a 3-D U-Net architecture was used to generate structures to be used with the PD Metric calculations. An image-to-image translation network is trained using a CycleGAN to domain adapt between CT and CBCT images to assist the auto-segmentation process. Experiments are performed to compare the DIR accuracy with the 3-D U-Net generated structures and the manually segmented structures. Results demonstrate that the auto-segmented images improve the DIR accuracy equally when using manually segmented images. This helps in reducing manual overhead associated with segmenting the images and thus increases the end-to-end performance of the DIR algorithm making it suitable for clinical use.
- 28 November 2022
- Published by Drexel University Libraries
Improving Precision of Deformable Image Registration
Deformable image registration (DIR) has various applications in medical image analysis such as in adaptive radiotherapy (ART) and multi-atlas segmentation. ART uses DIR to warp the dose from the daily cone-beam CT (CBCT) image to the planning computed tomography (CT) image to accommodate anatomical changes that occur between dose planning and dose delivery. DIR aims to find a geometric transformation between corresponding image data and brings them into a common coordinate frame. DIR is an inherently ill-posed problem that lacks a unique mapping between the voxels of the two images being registered. As such, one must regularize the registration to achieve physically meaningful transforms. The regularization penalty is usually a function of derivatives of the displacement vector field and can be calculated either analytically or numerically. The numerical approach, however, is computationally expensive depending on the image size, and therefore a computationally efficient analytical framework has been developed. Cubic B-splines were used to model the displacement vector field. A generalized mathematical framework was developed that supports five distinct regularizers: diffusion, curvature, linear elastic, third-order, and total displacement. The approach was validated by comparing each regularizer with its numerical counterpart in terms of accuracy. Benchmarking results show that the analytic solutions run significantly faster - up to two orders of magnitude - than finite differencing-based numerical implementations. Additionally, the cost function used in the DIR optimization process is a global, low-level cost function. It fails to accurately align high-level image structures such as organs at risk (OARs). DIR accuracy can be improved locally by adding high-level structures such as contours and landmark points. A hybrid image similarity metric that incorporates a point-to-distance map (PD) metric was developed. Given a pair of segmented images, structures on the fixed image are represented as sets of points while structures on the moving image are described as distance maps. The total distance of all fixed points to their associated boundaries on the moving image constitutes the PD metric, which is combined with the more traditional intensity similarity metric between the fixed and moving images. The approach was validated using the pelvic reference dataset wherein the prostate, bladder, and rectum were manually segmented from the CT and CBCT images by a medical expert to obtain the segmented fixed and moving images. The accuracy of the deformable registration was quantified using the Dice Similarity Coefficient (DSC) and 95% Hausdorff Distance (95% HD), with and without the PD metric. Results demonstrate a much-improved overlap between the fixed and warped contours once the PD metric was applied. Moreover, the computational overhead associated with adding the PD metric was minimal. Finally, to circumvent the need for a medical expert to manually segment the structures, a 3-D U-Net architecture was used to generate structures to be used with the PD Metric calculations. An image-to-image translation network is trained using a CycleGAN to domain adapt between CT and CBCT images to assist the auto-segmentation process. Experiments are performed to compare the DIR accuracy with the 3-D U-Net generated structures and the manually segmented structures. Results demonstrate that the auto-segmented images improve the DIR accuracy equally when using manually segmented images. This helps in reducing manual overhead associated with segmenting the images and thus increases the end-to-end performance of the DIR algorithm making it suitable for clinical use.
- 16 July 2021
- Published by Drexel University Libraries
A New Approach to Detecting Frame Deletion in H.264 Encoded Digital Video
Due to the increasing prevalence of falsified video content, it is important to be able to identify altered video recordings. For certain types of video, removing small portions of content can change the perception of the events that transpire without leaving visually detectable evidence. In particular, removing a set or sequence of frames from the beginning of a video can change the context of surrounding events, especially in newsworthy content. Digital forensic techniques have been developed to detect this type of video manipulation, but were originally proposed for use on MPEG-2 video. Advances in video encoding, particularly in MPEG-4 and H.264 have called the effectiveness of these techniques into question. In this thesis, we examine the performance of detectors built using the methodology from MPEG-2 when applied to H.264 video, and show that indeed new methods are needed to detect frame deletion in modern video. We propose a new method for extracting fingerprints left behind by frame deletion in H.264 as well as an expanded frame deletion detection framework for ensuring robustness across videos captured by different camera models as well as variation in scene content or motion. We evaluate the performance of our proposed techniques as well as examine current limitations.
- 16 July 2021
- Published by Drexel University Libraries
A New Approach to Detecting Frame Deletion in H.264 Encoded Digital Video
Due to the increasing prevalence of falsified video content, it is important to be able to identify altered video recordings. For certain types of video, removing small portions of content can change the perception of the events that transpire without leaving visually detectable evidence. In particular, removing a set or sequence of frames from the beginning of a video can change the context of surrounding events, especially in newsworthy content. Digital forensic techniques have been developed to detect this type of video manipulation, but were originally proposed for use on MPEG-2 video. Advances in video encoding, particularly in MPEG-4 and H.264 have called the effectiveness of these techniques into question. In this thesis, we examine the performance of detectors built using the methodology from MPEG-2 when applied to H.264 video, and show that indeed new methods are needed to detect frame deletion in modern video. We propose a new method for extracting fingerprints left behind by frame deletion in H.264 as well as an expanded frame deletion detection framework for ensuring robustness across videos captured by different camera models as well as variation in scene content or motion. We evaluate the performance of our proposed techniques as well as examine current limitations.
- 16 July 2021
- Published by Drexel University Libraries
Improving Deformable Multi-Grid B-spline Registration using Heuristics and Deep Learning
The purpose of deformable image registration is to recover acceptable spatial transformations that align two images acquired at different periods of time into the same coordinate system. Due to the growing importance of modern image-guided therapies, the techniques continue to be widely investigated. B-spline based models are commonly used in modeling this type of transformations because of the robustness of modeling continuous dense deformations. However, shortcomings exist in state-of-art B-spline based models, such as the incapability of modeling discontinuous motions and the difficulty in clinical application due to requiring the estimation of an intractable number of free parameters. This thesis develops adaptive B-spline registration models for 3D image volumes and investigates the application of machine learning techniques to improve the accuracy and efficiency in several aspects. The specific contributions are: Reduce the computational burden in parameter optimization for both single grid and pyramid B-spline models, which makes it possible for registration of large-scale 3D image volumes. On one hand, the reduction is accomplished by introducing a parallel framework that partitions each image volume into independent tiles and rapidly solves an analytic formulation of the B-spline algorithm. On the other hand, the degree of freedom is dynamically defined by inspecting local regional features and thus dramatically reduces the number of parameters to optimize. Automatically learn B-spline parameter configuration that best suitable for expressing the deformation underlying registration. The use of multiple grids of varying spatial resolution has been thoroughly investigated due to the sensitivity of the optimization process to local minima while attempting to accurately recover complex local deformations. An octree structured B-spline pyramid construction pipeline, as well as a convolutional neural networks (CNN) based sparsity learning technique, are proposed to infer B-spline grids prior optimization to accurately model anatomical deformations. An approach that improves and evaluates registration quality with fully automatic landmark detection and matching on lung CT images. The respiratory deformation between images acquired from different phases is learned using CNNs to interpolate the correspondence of candidate landmarks on images. The final set of landmarks are integrated into registration to algorithmically improve the registration quality by providing higher-level knowledge of the anatomical form of the images.
- 16 July 2021
- Published by Drexel University Libraries
Improving Deformable Multi-Grid B-spline Registration using Heuristics and Deep Learning
The purpose of deformable image registration is to recover acceptable spatial transformations that align two images acquired at different periods of time into the same coordinate system. Due to the growing importance of modern image-guided therapies, the techniques continue to be widely investigated. B-spline based models are commonly used in modeling this type of transformations because of the robustness of modeling continuous dense deformations. However, shortcomings exist in state-of-art B-spline based models, such as the incapability of modeling discontinuous motions and the difficulty in clinical application due to requiring the estimation of an intractable number of free parameters. This thesis develops adaptive B-spline registration models for 3D image volumes and investigates the application of machine learning techniques to improve the accuracy and efficiency in several aspects. The specific contributions are: Reduce the computational burden in parameter optimization for both single grid and pyramid B-spline models, which makes it possible for registration of large-scale 3D image volumes. On one hand, the reduction is accomplished by introducing a parallel framework that partitions each image volume into independent tiles and rapidly solves an analytic formulation of the B-spline algorithm. On the other hand, the degree of freedom is dynamically defined by inspecting local regional features and thus dramatically reduces the number of parameters to optimize. Automatically learn B-spline parameter configuration that best suitable for expressing the deformation underlying registration. The use of multiple grids of varying spatial resolution has been thoroughly investigated due to the sensitivity of the optimization process to local minima while attempting to accurately recover complex local deformations. An octree structured B-spline pyramid construction pipeline, as well as a convolutional neural networks (CNN) based sparsity learning technique, are proposed to infer B-spline grids prior optimization to accurately model anatomical deformations. An approach that improves and evaluates registration quality with fully automatic landmark detection and matching on lung CT images. The respiratory deformation between images acquired from different phases is learned using CNNs to interpolate the correspondence of candidate landmarks on images. The final set of landmarks are integrated into registration to algorithmically improve the registration quality by providing higher-level knowledge of the anatomical form of the images.
- 16 July 2021
- Published by Drexel University Libraries
Image Analysis Methods for Identification and Segmentation of Biological Structures using Machine Learning Techniques
Image processing and analysis techniques often include segmentation where an image is subdivided into constituent objects based on certain classification techniques using descriptors like shape, size and other features. There are multiple techniques to achieve desired segmentation and each technique works only on specific types of data. Therefore, using an appropriate technique based on the data and environment is necessary. The focus of this thesis is on developing segmentation techniques to identify biological structures in an image and perform categorical classification of identified structures. This thesis begins with introduction to workflows that extract information from histology images, specifically, Immunohistochemistry (IHC) images followed by anatomic organ segmentation from thoracic CT image volumes. Specific contributions include the following: Extraction of microvessels from stained brightfield images representing hippocampal region of a mouse brain and analysis of stain uptake signal in microvessels to aid in understanding the protein distribution in the blood brain barrier (BBB). Stained microvessels are classified from the objects in the image by leveraging the label maps that are developed using features recognized by gabor filter banks. The classification task is accomplished by training a random forest to identify microvessels. The observed average false positive rate for this classification is less than 6%. Identifying of mRNA signal which represent tumor cells in RNAscope images. The algorithm employed to accomplish the classification of the signals from tumor positive cells from the tumor negative cells is color deconvolution which is available open source as an ImageJ plugin. The size of the uncompressed wholeslide RNAscope images and the operations involved in color deconvolution makes using the standard open source implementation impractical. Here, a GPU accelerated rapid color deconvolution algorithm is implemented which exhibits a wallclock time speed up of 108x with same accuracy as obtained from standard open source implementation. Organ identification and segmentation in thorax CT images. Firstly, drawbacks of a traditional superpixel method using centroidal voronoi tessallations (CVT) and graph-cuts is discussed which motivates the necessity of a convolutional neural network (CNN) based organ identification method. The CNNs we employ are an improvement to a typical CNN as it leverages the spatial anatomic relationship between the organs in the inference stage. The CNN outputs are also enhanced by a novel data augmentation method which utilizes realistic simulations of common anatomical variations in the anatomy found across representative patient population.identification. The average value of the detector accuracies for the right lung, left lung, and heart in the augmented dataset were found to be 94.87%, 95.37%, and 90.76% after the standard CNN stage, respectively. Introduction of spatial relationship using a Bayes classifier improved the detector accuracies to 95.14%, 96.20%, and 95.15%, respectively, showing a marked improvement in heart detection. Further, a delineation leg is added to the CNN which employs upsampling and upconvolution techniques to extend the detection results to image voxel level. The average accuracy for organ delineation obtained using our CNNs was found to be 95.85%.
- 16 July 2021
- Published by Drexel University Libraries
Image Analysis Methods for Identification and Segmentation of Biological Structures using Machine Learning Techniques
Image processing and analysis techniques often include segmentation where an image is subdivided into constituent objects based on certain classification techniques using descriptors like shape, size and other features. There are multiple techniques to achieve desired segmentation and each technique works only on specific types of data. Therefore, using an appropriate technique based on the data and environment is necessary. The focus of this thesis is on developing segmentation techniques to identify biological structures in an image and perform categorical classification of identified structures. This thesis begins with introduction to workflows that extract information from histology images, specifically, Immunohistochemistry (IHC) images followed by anatomic organ segmentation from thoracic CT image volumes. Specific contributions include the following: Extraction of microvessels from stained brightfield images representing hippocampal region of a mouse brain and analysis of stain uptake signal in microvessels to aid in understanding the protein distribution in the blood brain barrier (BBB). Stained microvessels are classified from the objects in the image by leveraging the label maps that are developed using features recognized by gabor filter banks. The classification task is accomplished by training a random forest to identify microvessels. The observed average false positive rate for this classification is less than 6%. Identifying of mRNA signal which represent tumor cells in RNAscope images. The algorithm employed to accomplish the classification of the signals from tumor positive cells from the tumor negative cells is color deconvolution which is available open source as an ImageJ plugin. The size of the uncompressed wholeslide RNAscope images and the operations involved in color deconvolution makes using the standard open source implementation impractical. Here, a GPU accelerated rapid color deconvolution algorithm is implemented which exhibits a wallclock time speed up of 108x with same accuracy as obtained from standard open source implementation. Organ identification and segmentation in thorax CT images. Firstly, drawbacks of a traditional superpixel method using centroidal voronoi tessallations (CVT) and graph-cuts is discussed which motivates the necessity of a convolutional neural network (CNN) based organ identification method. The CNNs we employ are an improvement to a typical CNN as it leverages the spatial anatomic relationship between the organs in the inference stage. The CNN outputs are also enhanced by a novel data augmentation method which utilizes realistic simulations of common anatomical variations in the anatomy found across representative patient population.identification. The average value of the detector accuracies for the right lung, left lung, and heart in the augmented dataset were found to be 94.87%, 95.37%, and 90.76% after the standard CNN stage, respectively. Introduction of spatial relationship using a Bayes classifier improved the detector accuracies to 95.14%, 96.20%, and 95.15%, respectively, showing a marked improvement in heart detection. Further, a delineation leg is added to the CNN which employs upsampling and upconvolution techniques to extend the detection results to image voxel level. The average accuracy for organ delineation obtained using our CNNs was found to be 95.85%.
- 16 July 2021
- Published by Drexel University Libraries
High-Performance Deformable Image Registration for Medical Applications
Spline based deformation methods are common in medical imaging due to their robustness and accuracy. These methods require a significant amount of computation time in order to obtain a sufficiently accurate spatial deformation between two or more image volumes. This work focuses on comparing the thin-plate spline registration technique against the bspline on a variety of hardware architectures. The architectures in question include the common i5/i7 architecture with single and multiple threads, nVidia's CUDA architecture on the GTX760, and Intel's Xeon Phi architecture.
- 16 July 2021
- Published by Drexel University Libraries
High-Performance Deformable Image Registration for Medical Applications
Spline based deformation methods are common in medical imaging due to their robustness and accuracy. These methods require a significant amount of computation time in order to obtain a sufficiently accurate spatial deformation between two or more image volumes. This work focuses on comparing the thin-plate spline registration technique against the bspline on a variety of hardware architectures. The architectures in question include the common i5/i7 architecture with single and multiple threads, nVidia's CUDA architecture on the GTX760, and Intel's Xeon Phi architecture.
- 16 July 2021
- Published by Drexel University Libraries
High-performance image registration algorithms for multi-core processors
Deformable registration consists of aligning two or more 3D images into a common coordinate frame. Fusing multiple images in this fashion quantifies changes in organ shape, size, and position as described by the image set, thus providing physicians with a more complete understanding of patient anatomy and function. In the field of image-guided surgery, for example, neurosurgeons can track localized deformations within the brain during surgical procedures, thereby reducing the amount of unresected tumor. Though deformable registration has the potential to improve the geometric precision for a variety of medical procedures, most modern algorithms are time consuming and, therefore, go unused for routine clinical procedures. This thesis develops highly data-parallel registration algorithms suitable for use on modern multi-core architectures, including graphics processing units (GPUs). Specific contributions include the following:Parallel versions of both unimodal and multi-modal B-spline registration algorithms where the deformation is described in terms of uniform cubic B-spline coefficients. The unimodal case involves aligning images obtained using the same imaging technique whereas multi-modal registration aligns images obtained via differing imaging techniques by employing the concept of statistical mutual information. Multi-core versions of an analytical regularization method that imposes smoothness constraints on the deformation derived by both unimodal and multi-modal registration. The proposed method operates entirely on the B-spline coefficients which parameterize the deformation and, therefore, exhibits superior performance, in terms of execution-time overhead, over numerical methods that use central differencing. The above contributions have been implemented as part of the high-performance medical image registration software package Plastimatch, which can be downloaded under an open source license from www.plastimatch.org. Plastimatch significantly reduces the execution time incurred by B-spline based registration algorithms: compared to highly optimized sequential implementations on the CPU, we achieve a speedup of approximately 21 times for GPU-based multi-modal deformable registration while maintaining near-identical registration quality and a speedup of approximately 600 times for multi-core CPU-based regularization. It is hoped that these improvements in processing speed will allow deformable registration to be routinely used in time-sensitive procedures such as image-guided surgery and image-guided radiotherapy which require low latency from imaging to analysis.
- 16 July 2021
- Published by Drexel University Libraries
High-performance image registration algorithms for multi-core processors
Deformable registration consists of aligning two or more 3D images into a common coordinate frame. Fusing multiple images in this fashion quantifies changes in organ shape, size, and position as described by the image set, thus providing physicians with a more complete understanding of patient anatomy and function. In the field of image-guided surgery, for example, neurosurgeons can track localized deformations within the brain during surgical procedures, thereby reducing the amount of unresected tumor. Though deformable registration has the potential to improve the geometric precision for a variety of medical procedures, most modern algorithms are time consuming and, therefore, go unused for routine clinical procedures. This thesis develops highly data-parallel registration algorithms suitable for use on modern multi-core architectures, including graphics processing units (GPUs). Specific contributions include the following:Parallel versions of both unimodal and multi-modal B-spline registration algorithms where the deformation is described in terms of uniform cubic B-spline coefficients. The unimodal case involves aligning images obtained using the same imaging technique whereas multi-modal registration aligns images obtained via differing imaging techniques by employing the concept of statistical mutual information. Multi-core versions of an analytical regularization method that imposes smoothness constraints on the deformation derived by both unimodal and multi-modal registration. The proposed method operates entirely on the B-spline coefficients which parameterize the deformation and, therefore, exhibits superior performance, in terms of execution-time overhead, over numerical methods that use central differencing. The above contributions have been implemented as part of the high-performance medical image registration software package Plastimatch, which can be downloaded under an open source license from www.plastimatch.org. Plastimatch significantly reduces the execution time incurred by B-spline based registration algorithms: compared to highly optimized sequential implementations on the CPU, we achieve a speedup of approximately 21 times for GPU-based multi-modal deformable registration while maintaining near-identical registration quality and a speedup of approximately 600 times for multi-core CPU-based regularization. It is hoped that these improvements in processing speed will allow deformable registration to be routinely used in time-sensitive procedures such as image-guided surgery and image-guided radiotherapy which require low latency from imaging to analysis.
- 16 July 2021
- Published by Drexel University Libraries
Machine Learning Techniques for Forensic Camera Model Identification and Anti-forensic Attacks
The goal of camera model identification is to determine the manufacturer and model of an image's source camera. Camera model identification is an important task in multimedia forensics because it helps verify the origin of an image and uncover possible image forgeries. Forensic camera model identification is generally performed by searching an image for model-specific traces left by a camera's internal image processing components. Many techniques, including recent data-driven deep learning algorithms, have been developed to perform camera model identification. In the meantime, forensic researchers have discovered that existing camera model identification algorithms can be maliciously attacked by altering images without leaving visually distinguishable artifacts. These anti-forensic attacks arouse concerns about the robustness of camera model identification techniques and urge the need for effective defense strategies. In this thesis, we propose new algorithms to perform forensic camera model identification, and new anti-forensic attacks. We first introduce a highly accurate and robust camera model identification framework developed by fully exploiting demosaicing traces left by cameras' internal demosaicing process. In light of the complexity of demosaicing traces, we build an ensemble of statistical models to capture diverse demosaicing information in the form of content-dependent color value correlations. Diversity among these statistical models is critical for each model to capture a unique set of color correlations introduced by the demosaicing process. We obtain a diverse set of linear and non-linear demosaicing residuals and extract both intra-channel and inter-channel color correlations following a variety of geometric structures. The ensemble of collect diverse color correlations forms a comprehensive representation of the sophisticated demosaicing process inside a camera. This proposed framework not only achieves high camera model identification accuracy, but more importantly, it is robust to image post-processing operations and anti-forensic camera model attacks. Given recent popularity of deep learning algorithms, forensic researchers have started to build deep neural networks, especially convolutional neural networks, to perform camera model identification. In this thesis, we investigate the robustness of deep learning based camera model identification algorithms by developing anti-forensic camera model attacks to expose vulnerability of these algorithms. We propose a generative adversarial attack to perform targeted camera model falsification. Given full access to the camera model identification networks, this attack has been proven to be able to falsify camera models of images from arbitrary sources. Under black-box scenarios where no information about the camera model identification networks is available, we train a substitute network which mimics the camera model identification networks and provides gradient information to craft adversarial images.
- 16 July 2021
- Published by Drexel University Libraries
Machine Learning Techniques for Forensic Camera Model Identification and Anti-forensic Attacks
The goal of camera model identification is to determine the manufacturer and model of an image's source camera. Camera model identification is an important task in multimedia forensics because it helps verify the origin of an image and uncover possible image forgeries. Forensic camera model identification is generally performed by searching an image for model-specific traces left by a camera's internal image processing components. Many techniques, including recent data-driven deep learning algorithms, have been developed to perform camera model identification. In the meantime, forensic researchers have discovered that existing camera model identification algorithms can be maliciously attacked by altering images without leaving visually distinguishable artifacts. These anti-forensic attacks arouse concerns about the robustness of camera model identification techniques and urge the need for effective defense strategies. In this thesis, we propose new algorithms to perform forensic camera model identification, and new anti-forensic attacks. We first introduce a highly accurate and robust camera model identification framework developed by fully exploiting demosaicing traces left by cameras' internal demosaicing process. In light of the complexity of demosaicing traces, we build an ensemble of statistical models to capture diverse demosaicing information in the form of content-dependent color value correlations. Diversity among these statistical models is critical for each model to capture a unique set of color correlations introduced by the demosaicing process. We obtain a diverse set of linear and non-linear demosaicing residuals and extract both intra-channel and inter-channel color correlations following a variety of geometric structures. The ensemble of collect diverse color correlations forms a comprehensive representation of the sophisticated demosaicing process inside a camera. This proposed framework not only achieves high camera model identification accuracy, but more importantly, it is robust to image post-processing operations and anti-forensic camera model attacks. Given recent popularity of deep learning algorithms, forensic researchers have started to build deep neural networks, especially convolutional neural networks, to perform camera model identification. In this thesis, we investigate the robustness of deep learning based camera model identification algorithms by developing anti-forensic camera model attacks to expose vulnerability of these algorithms. We propose a generative adversarial attack to perform targeted camera model falsification. Given full access to the camera model identification networks, this attack has been proven to be able to falsify camera models of images from arbitrary sources. Under black-box scenarios where no information about the camera model identification networks is available, we train a substitute network which mimics the camera model identification networks and provides gradient information to craft adversarial images.
- 16 July 2021
- Published by Drexel University Libraries
Registration of Human Breast Mammography and Ultrasonography for Improved Breast Cancer Detection
Breast cancer is the second leading cause of death for women in the United States. In 2016 alone, over 250,000 new patients will be diagnosed and over 40,000 will die from some form of breast cancer. The current standard of care for breast cancer screening is primarily dependent on mammography. Magnetic resonance imaging (MRI) is extremely valuable for diagnosing patients who have dense or scarred breast tissue; however, the integration of MRI into breast cancer screening can be difficult. Radiographic alternatives to MRI are avoided to prevent risks associated with increased radiation exposure. Volumetric ultrasonic imaging, while inadequate for standalone screening, is a potential solution for complex screening cases if the modality can be fused with mammography scans. The additional information provided by volumetric ultrasound data allows for clearer discrimination between soft tissues possessing similar radiographic densities. This project aims to fuse volumetric ultrasound images with mammography scans by developing a new registration algorithm. This algorithm first reduces the dimensionality of the volumetric ultrasound to that of the target mammography projection. The ultrasound projections are then used to align the ultrasound volume and mammography images in three dimensional space and account for differences in deformation between the two modalities by framing the global and local registrations as an optimization problem.
- 16 July 2021
- Published by Drexel University Libraries
Registration of Human Breast Mammography and Ultrasonography for Improved Breast Cancer Detection
Breast cancer is the second leading cause of death for women in the United States. In 2016 alone, over 250,000 new patients will be diagnosed and over 40,000 will die from some form of breast cancer. The current standard of care for breast cancer screening is primarily dependent on mammography. Magnetic resonance imaging (MRI) is extremely valuable for diagnosing patients who have dense or scarred breast tissue; however, the integration of MRI into breast cancer screening can be difficult. Radiographic alternatives to MRI are avoided to prevent risks associated with increased radiation exposure. Volumetric ultrasonic imaging, while inadequate for standalone screening, is a potential solution for complex screening cases if the modality can be fused with mammography scans. The additional information provided by volumetric ultrasound data allows for clearer discrimination between soft tissues possessing similar radiographic densities. This project aims to fuse volumetric ultrasound images with mammography scans by developing a new registration algorithm. This algorithm first reduces the dimensionality of the volumetric ultrasound to that of the target mammography projection. The ultrasound projections are then used to align the ultrasound volume and mammography images in three dimensional space and account for differences in deformation between the two modalities by framing the global and local registrations as an optimization problem.
- 26 May 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (4) , 045011
A generalized framework for analytic regularization of uniform cubic B-spline displacement fields
Image registration is an inherently ill-posed problem that lacks the constraints needed for a unique mapping between voxels of the two images being registered. As such, one must regularize the registration to achieve physically meaningful transforms. The regularization penalty is usually a function of derivatives of the displacement-vector field and can be calculated either analytically or numerically. The numerical approach, however, is computationally expensive depending on the image size, and therefore a computationally efficient analytical framework has been developed. Using cubic B-splines as the registration transform, we develop a generalized mathematical framework that supports five distinct regularizers: diffusion, curvature, linear elastic, third-order, and total displacement. We validate our approach by comparing each with its numerical counterpart in terms of accuracy. We also provide benchmarking results showing that the analytic solutions run significantly faster—up to two orders of magnitude—than finite differencing based numerical implementations.
- 26 May 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (4) , 045011
A generalized framework for analytic regularization of uniform cubic B-spline displacement fields
Image registration is an inherently ill-posed problem that lacks the constraints needed for a unique mapping between voxels of the two images being registered. As such, one must regularize the registration to achieve physically meaningful transforms. The regularization penalty is usually a function of derivatives of the displacement-vector field and can be calculated either analytically or numerically. The numerical approach, however, is computationally expensive depending on the image size, and therefore a computationally efficient analytical framework has been developed. Using cubic B-splines as the registration transform, we develop a generalized mathematical framework that supports five distinct regularizers: diffusion, curvature, linear elastic, third-order, and total displacement. We validate our approach by comparing each with its numerical counterpart in terms of accuracy. We also provide benchmarking results showing that the analytic solutions run significantly faster—up to two orders of magnitude—than finite differencing based numerical implementations.
- 24 February 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 101330W-101330W-9
An octree based approach to multi-grid B-spline registration
- 24 February 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 101330W-101330W-9
An octree based approach to multi-grid B-spline registration