Camilla Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Camilla Tang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hans-Jørgen Albrechtsen
DTU Sustain, Technical University of Denmark, Kongens Lyngby, Denmark
4 shared publications - Martin Rygaard
Department of Environmental and Resource Engineering, Water Technology and Processes, Technical University of Denmark, Bygningstorvet, Building 115, 2800, Lyngby, Denmark
2 shared publications Thomas H. Christensen
Institute of Environmental Science and Engineering/Groundwater Research Centre, Technical University of Denmark, Bldg. 115, DK-2800 Lyngby, Denmark
2 shared publications- Berit Godskesen
Department of Environmental Engineering, Technical University of Denmark, Bygningstorvet 115, 2800 Kgs. Lyngby, Denmark
1 shared publication Christian Grøn
Technical University of Denmark
1 shared publicationCornelis Wilhelmus Adrianus Maria Merks
Witteveen + Bos International Projects B.V., Van Twickelostraat 2, P.O. Box 233, 7400 AE. Deventer, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 1 September 2021
- Published by Elsevier in Water Research
- Vol. 203, 117439
Evaluation and comparison of centralized drinking water softening technologies: Effects on water quality indicators
- 1 September 2021
- Published by Elsevier in Water Research
- Vol. 203, 117439
Open AccessEvaluation and comparison of centralized drinking water softening technologies: Effects on water quality indicators
- Open Access
Procedure for Calculating the Calcium Carbonate Precipitation Potential (CCPP) in Drinking Water Supply: Importance of Temperature, Ionic Species and Open/Closed System
The calcium carbonate (CaCO3) precipitation potential (CCPP) can predict the potential for corrosion and lime scaling in drinking water systems. CCPP can be calculated by different standards, but none of these consider all of the conditions in drinking water systems where temperatures can reach 100 °C and the water exchanges CO2 with the atmosphere. We provided and demonstrated a procedure for CCPP calculations using the open-source software PHREEQC with the phreeqc.dat database at temperatures relevant for drinking water systems (10–90 °C) and for open systems in equilibrium with atmospheric CO2. CCPP increased by 0.17–1.51 mmol/kg when the temperature was increased from 10 °C to 90 °C and increased by 0.22–2.82 mmol/kg when going from closed to open systems at 10 °C. Thus, CaCO3 precipitation may be underestimated if CCPP is only considered for the lower sample temperature and for closed systems. On the other hand, CCPP10 decreased by 0.006–0.173 mmol/kg when including the ionic species from the German DIN 38404-10 standard in addition to calcium, alkalinity and pH, indicating that all relevant ionic species should be included in CCPP calculations. CCPP values should always be reported with the calculation procedure and temperature to avoid inconsistency in literature.
Open AccessProcedure for Calculating the Calcium Carbonate Precipitation Potential (CCPP) in Drinking Water Supply: Importance of Temperature, Ionic Species and Open/Closed System
The calcium carbonate (CaCO3) precipitation potential (CCPP) can predict the potential for corrosion and lime scaling in drinking water systems. CCPP can be calculated by different standards, but none of these consider all of the conditions in drinking water systems where temperatures can reach 100 °C and the water exchanges CO2 with the atmosphere. We provided and demonstrated a procedure for CCPP calculations using the open-source software PHREEQC with the phreeqc.dat database at temperatures relevant for drinking water systems (10–90 °C) and for open systems in equilibrium with atmospheric CO2. CCPP increased by 0.17–1.51 mmol/kg when the temperature was increased from 10 °C to 90 °C and increased by 0.22–2.82 mmol/kg when going from closed to open systems at 10 °C. Thus, CaCO3 precipitation may be underestimated if CCPP is only considered for the lower sample temperature and for closed systems. On the other hand, CCPP10 decreased by 0.006–0.173 mmol/kg when including the ionic species from the German DIN 38404-10 standard in addition to calcium, alkalinity and pH, indicating that all relevant ionic species should be included in CCPP calculations. CCPP values should always be reported with the calculation procedure and temperature to avoid inconsistency in literature.
- 13 June 2019
- Published by IWA Publishing in Water Supply
- Vol. 19 (7) , 2088-2097
Water softeners add comfort and consume water – comparison of selected centralised and decentralised softening technologies
Selected technologies for centralised or decentralised drinking water softening were evaluated based on technical, economic, environmental and aesthetic indicators to identify the optimal treatment technology for a given setting. To achieve this, we demonstrated that a number of important indicators beyond hardness reduction and costs have to be included. All the evaluated centralised softening technologies could reduce water hardness to the target of 1.3 mmol/L at the Dutch drinking water treatment plant Beilen. CARIX® treatment and pellet softening with Ca(OH)2 resulted in a lower CCPP90 (0.25–0.30 mmol/L) than nanofiltration (0.30–0.35 mmol/L). Decentralised reverse osmosis had a water consumption of >100%, whereas decentralised cation exchange had a water consumption of 2.5–4.5% which was comparable to centralised pellet softening (3.6%). Except for the electronic water conditioner that does not remove water hardness, the decentralised technologies were 7–10 times more expensive than the centralised technologies per m3 of softened water. The centralised softening technologies furthermore ensured supply of softened water to all customers in a water supply zone. Thus, in areas with hard water and limescale problems investment in centralised softening at the local water utility is more optimal than widespread implementation of decentralised systems.
- 13 June 2019
- Published by IWA Publishing in Water Supply
- Vol. 19 (7) , 2088-2097
Water softeners add comfort and consume water – comparison of selected centralised and decentralised softening technologies
Selected technologies for centralised or decentralised drinking water softening were evaluated based on technical, economic, environmental and aesthetic indicators to identify the optimal treatment technology for a given setting. To achieve this, we demonstrated that a number of important indicators beyond hardness reduction and costs have to be included. All the evaluated centralised softening technologies could reduce water hardness to the target of 1.3 mmol/L at the Dutch drinking water treatment plant Beilen. CARIX® treatment and pellet softening with Ca(OH)2 resulted in a lower CCPP90 (0.25–0.30 mmol/L) than nanofiltration (0.30–0.35 mmol/L). Decentralised reverse osmosis had a water consumption of >100%, whereas decentralised cation exchange had a water consumption of 2.5–4.5% which was comparable to centralised pellet softening (3.6%). Except for the electronic water conditioner that does not remove water hardness, the decentralised technologies were 7–10 times more expensive than the centralised technologies per m3 of softened water. The centralised softening technologies furthermore ensured supply of softened water to all customers in a water supply zone. Thus, in areas with hard water and limescale problems investment in centralised softening at the local water utility is more optimal than widespread implementation of decentralised systems.
- 1 February 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 652, 538-548
Softening of drinking water by the pellet reactor - Effects of influent water composition on calcium carbonate pellet characteristics
- 1 February 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 652, 538-548
Softening of drinking water by the pellet reactor - Effects of influent water composition on calcium carbonate pellet characteristics
- 1 September 2014
- Published by Elsevier in Water Research
- Vol. 60, 64-74
Biocides in urban wastewater treatment plant influent at dry and wet weather: Concentrations, mass flows and possible sources
- 1 September 2014
- Published by Elsevier in Water Research
- Vol. 60, 64-74
Biocides in urban wastewater treatment plant influent at dry and wet weather: Concentrations, mass flows and possible sources
- Open Access
- 1 March 1995
- Published by Oxford University Press (OUP) in FEMS Microbiology Ecology
- Vol. 16 (3) , 233-247
Limiting factors for microbial Fe(III) -reduction in a landfill leachate polluted aquifer (Vejen, Denmark)
Aquifer sediment samples from two locations within the anaerobic leachate plume of a municipal landfill were compared with respect to microbiology (especially Fe(III)-reduction) and geochemistry. The samples close to the landfill were characterized by low contents of Fe(III), whereas samples from the more distant cluster were rich in Fe(III)-oxides. The active microbial population seemed to be less dense in samples more distant from the landfill (measured by ATP and phospholipid fatty acids (PLFA)), but the microbial communities were very similar in the two sample clusters according to the composition of PLFA. Very little, if any, Fe(III)-reduction was observed close to the landfill, but all the more distant samples showed evident microbially mediated Fe(III)-reduction. After amendment with both acetate and Fe(III), all the samples showed a potential for Fe(III)-reduction, and the in situ Fe(III)-reduction seemed to be limited by the lack of Fe(III)-availability. It was suggested, that Fe(III)-reducing populations might be facultative, surviving by use of other electron-acceptors than Fe(III), when Fe(III) is not available for reduction.
- 1 March 1995
- Published by Oxford University Press (OUP) in FEMS Microbiology Ecology
- Vol. 16 (3) , 233-247
Open AccessLimiting factors for microbial Fe(III) -reduction in a landfill leachate polluted aquifer (Vejen, Denmark)
Aquifer sediment samples from two locations within the anaerobic leachate plume of a municipal landfill were compared with respect to microbiology (especially Fe(III)-reduction) and geochemistry. The samples close to the landfill were characterized by low contents of Fe(III), whereas samples from the more distant cluster were rich in Fe(III)-oxides. The active microbial population seemed to be less dense in samples more distant from the landfill (measured by ATP and phospholipid fatty acids (PLFA)), but the microbial communities were very similar in the two sample clusters according to the composition of PLFA. Very little, if any, Fe(III)-reduction was observed close to the landfill, but all the more distant samples showed evident microbially mediated Fe(III)-reduction. After amendment with both acetate and Fe(III), all the samples showed a potential for Fe(III)-reduction, and the in situ Fe(III)-reduction seemed to be limited by the lack of Fe(III)-availability. It was suggested, that Fe(III)-reducing populations might be facultative, surviving by use of other electron-acceptors than Fe(III), when Fe(III) is not available for reduction.
- 1 January 1993
- Published by Springer Nature
- p. 473-474
Substrate Value of Landfill Leachate Polluted Groundwater for Microbial Degradation under Different Redox Conditions
- 1 January 1993
- Published by Springer Nature
- p. 473-474
Substrate Value of Landfill Leachate Polluted Groundwater for Microbial Degradation under Different Redox Conditions