Fatimah Dinan Qonitan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fatimah Dinan Qonitan has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Aaron Cohen
Health Effects Institute, 101 Federal Street Suite 500, Boston, MA, USA
2 shared publications- Abdus Salam
University of Dhaka
2 shared publications Ainsley Walsh
Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada
2 shared publicationsAmanda Ring
Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada
2 shared publicationsAmit Misra
Center for Environmental Science and Engineering, Indian Institute of Technology Kanpur, Kanpur, India
2 shared publicationsAri Rahman
Universitas Pertamina
2 shared publications
Latest Publications
- Open Access
- 30 September 2024
- Published by Institut Teknologi Adhi Tama Surabaya in Journal of Earth and Marine Technology (JEMT)
- Vol. 5 (1) , 80-90
PM2.5 Exposure and Health Symptoms in Elderly Residents: A Case Study in Jakarta during the COVID-19 Pandemic
The deterioration of air quality in Jakarta, Indonesia, has become a growing public concern. Exposure to polluted air is known to be hazardous to public health, particularly for sensitive groups such as elderly citizens. PM2.5 (fine particulate matter with an aerodynamic diameter 2.5 μm) is among the most dangerous pollutants commonly found in urban atmospheres. This study assessed the relationship between atmospheric PM2.5 exposure and health-related symptoms among elderly citizens living in Jakarta, Indonesia. PM2.5 concentrations in ambient air were measured using a High Volume Air Sampler with a PM2.5 size-selective inlet for a week in an outdoor location at a nursing home during the Covid-19 pandemic. Health-related symptoms of elderly citizens were collected using a systematic interview method. Both sets of data were collected simultaneously for cross-sectional analysis. Based on the sampling data, PM2.5 concentrations in the area ranged from 15.4 to 42.9 μg/Nm3 (at standard conditions); the Air Pollution Standard Index ranged from 49.9 to 84.3; and the Air Quality Index was moderate for 6 out of 7 (85.7%) days. Results showed that sensitive groups, including elderly citizens, are very likely to be negatively affected by polluted air. The chi-square test results imply that emerging health-related symptoms are significantly affected by elderly citizen characteristics, such as age, gender, smoking habit, and residence time, rather than by the Air Quality Index.
- 30 September 2024
- Published by Institut Teknologi Adhi Tama Surabaya in Journal of Earth and Marine Technology (JEMT)
- Vol. 5 (1) , 80-90
Open AccessPM2.5 Exposure and Health Symptoms in Elderly Residents: A Case Study in Jakarta during the COVID-19 Pandemic
The deterioration of air quality in Jakarta, Indonesia, has become a growing public concern. Exposure to polluted air is known to be hazardous to public health, particularly for sensitive groups such as elderly citizens. PM2.5 (fine particulate matter with an aerodynamic diameter 2.5 μm) is among the most dangerous pollutants commonly found in urban atmospheres. This study assessed the relationship between atmospheric PM2.5 exposure and health-related symptoms among elderly citizens living in Jakarta, Indonesia. PM2.5 concentrations in ambient air were measured using a High Volume Air Sampler with a PM2.5 size-selective inlet for a week in an outdoor location at a nursing home during the Covid-19 pandemic. Health-related symptoms of elderly citizens were collected using a systematic interview method. Both sets of data were collected simultaneously for cross-sectional analysis. Based on the sampling data, PM2.5 concentrations in the area ranged from 15.4 to 42.9 μg/Nm3 (at standard conditions); the Air Pollution Standard Index ranged from 49.9 to 84.3; and the Air Quality Index was moderate for 6 out of 7 (85.7%) days. Results showed that sensitive groups, including elderly citizens, are very likely to be negatively affected by polluted air. The chi-square test results imply that emerging health-related symptoms are significantly affected by elderly citizen characteristics, such as age, gender, smoking habit, and residence time, rather than by the Air Quality Index.
- Open Access
- 1 January 2024
- Published by European Alliance for Innovation n.o.
Determining factors for the utilization of mangrove forest in Bontang, East Kalimantan
The area of mangrove forests in Bontang City may decrease over time. While mangrove forest and its ecosystem have great potential to prevent coastal abrasion, absorb and store carbon, which threatens climate change, and sources of income of the coastal communities. This research aims to analyzes determining factors to use mangrove forests and to know the behavior of the community towards preserving mangrove forests. Using primary data from 186 respondents, this study utilized logistic regression analysis method. The results show that majority of Bontang City residents are aware about the existence of protected mangrove forests. Determining factors that influence the Bontang city's people utilizing the mangrove forests are kind of job, knowledge and distance from mangrove forest areas.
- 1 January 2024
- Published by European Alliance for Innovation n.o.
Open AccessDetermining factors for the utilization of mangrove forest in Bontang, East Kalimantan
The area of mangrove forests in Bontang City may decrease over time. While mangrove forest and its ecosystem have great potential to prevent coastal abrasion, absorb and store carbon, which threatens climate change, and sources of income of the coastal communities. This research aims to analyzes determining factors to use mangrove forests and to know the behavior of the community towards preserving mangrove forests. Using primary data from 186 respondents, this study utilized logistic regression analysis method. The results show that majority of Bontang City residents are aware about the existence of protected mangrove forests. Determining factors that influence the Bontang city's people utilizing the mangrove forests are kind of job, knowledge and distance from mangrove forest areas.
- Open Access
- 1 January 2024
- Published by European Alliance for Innovation n.o.
Analysis of Carbon Footprint and Impact of Global Warming Potential on Aspects of Transportation, Electricity and Water Use in Istiqlal Mosque
This research assesses the carbon footprint from transportation, electricity consumption, and water usage at Istiqlal Mosque, Jakarta. The primary objectives are to quantify emissions, conduct impact analysis, and propose strategies for reducing the carbon footprint in these three aspects. The method employed involves calculating the carbon footprint using emission factors. The results indicate the carbon footprints as follows: 1,653.87 kg CO2/month for transportation, 183,670 kg CO2/month for electricity, and 2,710.60 kg CO2/month for water consumption. These emissions have the potential to contribute to global warming, resulting in estimated impacts of 610 kg CO2-eq/month for transportation, 242,000 kg CO2-eq/month for electricity, and 2,560 kg CO2-eq/month for water consumption. Proposed carbon footprint reduction measures include implementing Car-Free Day (CFD) initiatives, installing a 150-kilowatt-peak (KWP) solar panel system, incorporating water-saving features, and establishing a rainwater harvesting system. These recommendations can help Istiqlal Mosque reduce its carbon footprint and support environmental sustainability.
- 1 January 2024
- Published by European Alliance for Innovation n.o.
Open AccessAnalysis of Carbon Footprint and Impact of Global Warming Potential on Aspects of Transportation, Electricity and Water Use in Istiqlal Mosque
This research assesses the carbon footprint from transportation, electricity consumption, and water usage at Istiqlal Mosque, Jakarta. The primary objectives are to quantify emissions, conduct impact analysis, and propose strategies for reducing the carbon footprint in these three aspects. The method employed involves calculating the carbon footprint using emission factors. The results indicate the carbon footprints as follows: 1,653.87 kg CO2/month for transportation, 183,670 kg CO2/month for electricity, and 2,710.60 kg CO2/month for water consumption. These emissions have the potential to contribute to global warming, resulting in estimated impacts of 610 kg CO2-eq/month for transportation, 242,000 kg CO2-eq/month for electricity, and 2,560 kg CO2-eq/month for water consumption. Proposed carbon footprint reduction measures include implementing Car-Free Day (CFD) initiatives, installing a 150-kilowatt-peak (KWP) solar panel system, incorporating water-saving features, and establishing a rainwater harvesting system. These recommendations can help Istiqlal Mosque reduce its carbon footprint and support environmental sustainability.
- Open Access
- 22 October 2023
- Published by Faculty of Infrastructure Planning, Universitas Pertamina in Journal of Sustainable Infrastructure
- Vol. 2 (2)
Evaluasi Aspek Konservasi Air berdasarkan Prinsip Green Building (Studi Kasus Gedung Griya Legita, Universitas Pertamina)
Water conservation is an integral component of Green Building principles. Green buildings not only emphasize energy efficiency but also need to consider water resource conservation. Therefore, this research aims to conduct a study on water conservation in the campus environment of the University of Pertamina, specifically Griya Legita, with a focus on the implementation of Green Building principles. Through the analysis of water consumption, observation of existing water conservation efforts, and a comparison with the Greenship Existing Building version 1.1 Green Building standards, this study aims to identify potential improvements in water usage on the University of Pertamina campus. The research findings indicate that, based on the water conservation criteria in Greenship Existing Building version 1.1, a score of 9 out of a total of 20 points was obtained. Some of the implemented efforts include water monitoring control and freshwater efficiency. Areas for improvement include installing sub-metering for water consumption monitoring, conducting periodic laboratory testing of water quality, and enhancing management commitment and water conservation awareness among the campus community. The results of this study provide recommendations on how the campus can more effectively implement Green Building principles that involve water conservation.
- 22 October 2023
- Published by Faculty of Infrastructure Planning, Universitas Pertamina in Journal of Sustainable Infrastructure
- Vol. 2 (2)
Open AccessEvaluasi Aspek Konservasi Air berdasarkan Prinsip Green Building (Studi Kasus Gedung Griya Legita, Universitas Pertamina)
Water conservation is an integral component of Green Building principles. Green buildings not only emphasize energy efficiency but also need to consider water resource conservation. Therefore, this research aims to conduct a study on water conservation in the campus environment of the University of Pertamina, specifically Griya Legita, with a focus on the implementation of Green Building principles. Through the analysis of water consumption, observation of existing water conservation efforts, and a comparison with the Greenship Existing Building version 1.1 Green Building standards, this study aims to identify potential improvements in water usage on the University of Pertamina campus. The research findings indicate that, based on the water conservation criteria in Greenship Existing Building version 1.1, a score of 9 out of a total of 20 points was obtained. Some of the implemented efforts include water monitoring control and freshwater efficiency. Areas for improvement include installing sub-metering for water consumption monitoring, conducting periodic laboratory testing of water quality, and enhancing management commitment and water conservation awareness among the campus community. The results of this study provide recommendations on how the campus can more effectively implement Green Building principles that involve water conservation.
- Open Access
- 1 January 2023
- Published by European Alliance for Innovation n.o.
Water Quality Status of an Urban River in Jakarta – Nature-Based Solution Recommendations for Water Quality Improvement
The Park and Forest Service (Distamhut) of DKI Jakarta Province has a goal to increase the city's green open spaces by utilizing the city's river banks. This research evaluated the water quality of a river segment from the Cilangkap River, Sunter River Basin, and Ciliwung-Cisadane watershed. Located adjacent to an urban and residential area, the 1.19 km river segment received wastewater from domestic, agricultural, fisheries, and small-scale factory activities. Water samples are taken from 4 sampling points along the river during August 2022. Although utilized for fisheries and agriculture, the Pollution Index (IP) for Class III shows that the Pollution Index value is in the range of 0 < Plj 5.0, thus the river is lightly polluted. This paper also reviews several of the nature-based solution as recommendation for improving river water quality. Bioretention ponds, rain gardens, or surface-flow wetlands are the several alternatives that can be applied for improving urban river.
- 1 January 2023
- Published by European Alliance for Innovation n.o.
Open AccessWater Quality Status of an Urban River in Jakarta – Nature-Based Solution Recommendations for Water Quality Improvement
The Park and Forest Service (Distamhut) of DKI Jakarta Province has a goal to increase the city's green open spaces by utilizing the city's river banks. This research evaluated the water quality of a river segment from the Cilangkap River, Sunter River Basin, and Ciliwung-Cisadane watershed. Located adjacent to an urban and residential area, the 1.19 km river segment received wastewater from domestic, agricultural, fisheries, and small-scale factory activities. Water samples are taken from 4 sampling points along the river during August 2022. Although utilized for fisheries and agriculture, the Pollution Index (IP) for Class III shows that the Pollution Index value is in the range of 0 < Plj 5.0, thus the river is lightly polluted. This paper also reviews several of the nature-based solution as recommendation for improving river water quality. Bioretention ponds, rain gardens, or surface-flow wetlands are the several alternatives that can be applied for improving urban river.
- Open Access
- 1 January 2023
- Published by European Alliance for Innovation n.o.
Influence of Physical Work Environment: Temperature, Humidity, Light Intensity, and Vibration on Construction Worker's Subjective Comfort
The physical work environment is everything around workers that can affect them in carrying out work tasks, such as lighting conditions, temperature, humidity, and vibrations caused by the use of specific tools. This study aims to evaluate the physical factors of the work environment and quantify the influence of these factors on the personal comfort level of project workers. The factors of light intensity, temperature, humidity, and vibration were measured using a lux meter, hygro-thermometer psychrometer, and vibration meter. The measurements were conducted during the 6 (six) working days at a building construction site in Jakarta. Subjective comfort was surveyed using questionnaires filled out by the workers. During the study, the workers were active in 5 (five) different workstations, including pipework, installation of cable networks, ducting assembly, and welding. Measurement in all stations resulted in an average light intensity of 196.6 lux, a temperature of 30.97°C, a humidity of 55.29%, and vibration of 9.4 m/s which sometimes violates the national threshold value regulated by the Minister of Labor of the Republic of Indonesia Number 5 of 2018. A multiple linear regression analysis was carried out to quantify the influence of the parameters on the workers' subjective comfort using the SPSS Software Version 25.0. The multiple linear regression analysis showed that for a 95% confidence level, all parameters together have a statistically significant influence on the subjective comfort of workers with Sig = 0.001. While only temperature (Sig = 0.019) and vibration (Sig = 0.001) have an independent statistically significant influence, temperature and vibration become priority parameters for workers' subjective comfort improvement. The comfort of the working environment on temperature and vibration parameters can be improved by providing a portable fan and making a rubber engine holder for dampening vibrations.
- 1 January 2023
- Published by European Alliance for Innovation n.o.
Open AccessInfluence of Physical Work Environment: Temperature, Humidity, Light Intensity, and Vibration on Construction Worker's Subjective Comfort
The physical work environment is everything around workers that can affect them in carrying out work tasks, such as lighting conditions, temperature, humidity, and vibrations caused by the use of specific tools. This study aims to evaluate the physical factors of the work environment and quantify the influence of these factors on the personal comfort level of project workers. The factors of light intensity, temperature, humidity, and vibration were measured using a lux meter, hygro-thermometer psychrometer, and vibration meter. The measurements were conducted during the 6 (six) working days at a building construction site in Jakarta. Subjective comfort was surveyed using questionnaires filled out by the workers. During the study, the workers were active in 5 (five) different workstations, including pipework, installation of cable networks, ducting assembly, and welding. Measurement in all stations resulted in an average light intensity of 196.6 lux, a temperature of 30.97°C, a humidity of 55.29%, and vibration of 9.4 m/s which sometimes violates the national threshold value regulated by the Minister of Labor of the Republic of Indonesia Number 5 of 2018. A multiple linear regression analysis was carried out to quantify the influence of the parameters on the workers' subjective comfort using the SPSS Software Version 25.0. The multiple linear regression analysis showed that for a 95% confidence level, all parameters together have a statistically significant influence on the subjective comfort of workers with Sig = 0.001. While only temperature (Sig = 0.019) and vibration (Sig = 0.001) have an independent statistically significant influence, temperature and vibration become priority parameters for workers' subjective comfort improvement. The comfort of the working environment on temperature and vibration parameters can be improved by providing a portable fan and making a rubber engine holder for dampening vibrations.
- Open Access
- 1 January 2023
- Published by European Alliance for Innovation n.o.
Determining Key Factors for Continuous Improvement of Environmental Management System (EMS) at Geothermal Power Plant (Case Study of PT. Pertamina Geothermal Energy Karaha Area)
Environmental Management Systems (EMS) play a pivotal role in addressing environmental issues. While organizations strive for EMS certification, achieving excellence in continuous improvement remains a challenge due to the lack of defined procedures and guidelines. This paper aims to address this challenge through a case study conducted at PT Pertamina Geothermal Energy (PGE) Karaha Area, an energy supply company. By analyzing audit findings, we identified technical aspects as obstacles to continuous improvement. Consequently, we seek to identify key factors that significantly influence the continuous improvement process. To achieve this, we employ the Matrix of Cross Impact Multiplication Applied to a Classification (MICMAC) structural analysis method developed by Godet. Our study aims to (i) identify EMS determinants, (ii) analyze the relationships between determinants, and (iii) categorize key factors that drive continuous improvement. Key continuous improvement factors include communication, production process, training, emergency preparedness and response, and document control. Recommendations for improvement include the implementation of coaching and feedback, motivation, and consistency to improve the communication process; the implementation of LCA analysis to improve the production process; the implementation of e-learning to improve training and emergency preparedness; and the implementation of electronic document management system in the document control process.
- 1 January 2023
- Published by European Alliance for Innovation n.o.
Open AccessDetermining Key Factors for Continuous Improvement of Environmental Management System (EMS) at Geothermal Power Plant (Case Study of PT. Pertamina Geothermal Energy Karaha Area)
Environmental Management Systems (EMS) play a pivotal role in addressing environmental issues. While organizations strive for EMS certification, achieving excellence in continuous improvement remains a challenge due to the lack of defined procedures and guidelines. This paper aims to address this challenge through a case study conducted at PT Pertamina Geothermal Energy (PGE) Karaha Area, an energy supply company. By analyzing audit findings, we identified technical aspects as obstacles to continuous improvement. Consequently, we seek to identify key factors that significantly influence the continuous improvement process. To achieve this, we employ the Matrix of Cross Impact Multiplication Applied to a Classification (MICMAC) structural analysis method developed by Godet. Our study aims to (i) identify EMS determinants, (ii) analyze the relationships between determinants, and (iii) categorize key factors that drive continuous improvement. Key continuous improvement factors include communication, production process, training, emergency preparedness and response, and document control. Recommendations for improvement include the implementation of coaching and feedback, motivation, and consistency to improve the communication process; the implementation of LCA analysis to improve the production process; the implementation of e-learning to improve training and emergency preparedness; and the implementation of electronic document management system in the document control process.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2743 (1)
Fecal sludge-based refuse-derived fuel pelletizing process: Effect on hardness, density, and calorific value
Refused-derived fuel (RDF) has been considered as a sustainable alternative for substituting fossil fuels. Fecal sludge is produced daily from sewage treatment plants in large volumes and usually ends in sludge hangars for disposal, as the residue from chemical and biological treatment of human waste. Despite its large volume and low water content, the utilization of fecal sludge as RDF has not been widely practiced in Indonesia. In this study, dried fecal sludge from the dewatering unit of a Sewage Treatment Plant in DKI Jakarta was used as raw material to produce RDF. In this study, pelletizing was carried out as an effort to densify and improve the physical characteristics of dried fecal sludge as RDF raw material. Dried fecal sludge is refined, weighed, added starch for adhesive, then molded into pellets. Pellets are molded using two different pelletizing processes, using screw pelletizer and revolving die pelletizer. The molded pellets were then dried and stored at room temperature with indirect sunlight for 6 hours before being analyzed for their quality parameters. This study analyzed and compared the physical characteristics of pellets produced using two different pelletizing processes for density, hardness, and calorific value parameters that influence the storage, transportation, and quality of the material. The result shows that both pelletizers have improved the quality of raw fecal sludge as refuse-derived fuel. As a result of the pelletizing process, the highest calorific value of the fecal sludge pellets is 3071.028 kcal/kg. The screw pelletizer produced higher calorific value pellets compared to the other, with longer but smaller diameters, larger densities, and smaller hardness.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2743 (1)
Open AccessFecal sludge-based refuse-derived fuel pelletizing process: Effect on hardness, density, and calorific value
Refused-derived fuel (RDF) has been considered as a sustainable alternative for substituting fossil fuels. Fecal sludge is produced daily from sewage treatment plants in large volumes and usually ends in sludge hangars for disposal, as the residue from chemical and biological treatment of human waste. Despite its large volume and low water content, the utilization of fecal sludge as RDF has not been widely practiced in Indonesia. In this study, dried fecal sludge from the dewatering unit of a Sewage Treatment Plant in DKI Jakarta was used as raw material to produce RDF. In this study, pelletizing was carried out as an effort to densify and improve the physical characteristics of dried fecal sludge as RDF raw material. Dried fecal sludge is refined, weighed, added starch for adhesive, then molded into pellets. Pellets are molded using two different pelletizing processes, using screw pelletizer and revolving die pelletizer. The molded pellets were then dried and stored at room temperature with indirect sunlight for 6 hours before being analyzed for their quality parameters. This study analyzed and compared the physical characteristics of pellets produced using two different pelletizing processes for density, hardness, and calorific value parameters that influence the storage, transportation, and quality of the material. The result shows that both pelletizers have improved the quality of raw fecal sludge as refuse-derived fuel. As a result of the pelletizing process, the highest calorific value of the fecal sludge pellets is 3071.028 kcal/kg. The screw pelletizer produced higher calorific value pellets compared to the other, with longer but smaller diameters, larger densities, and smaller hardness.
- Open Access
- 11 October 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 88 (1) , 12-23
Refuse Derived Fuel for Energy Recovery by Thermal Processes. A Case Study in Depok City, Indonesia
The number of words should not exceed 350. Depok City is one of Indonesia's big cities, which is currently focused on processing waste-to-energy. This research was conducted to study and describe waste management in Depok City to become renewable energy. Secondary data from the Depok City local government's inventory was used to determine the generation and composition of municipal solid waste (MSW). The waste's characterization was taken from the material recovery facility of Depok City, located at Jalan Merdeka. The amount of waste generated in Depok City is predicted to reach 681.612 tons/year by 2025. The significant waste composition items were food waste, garden waste, textiles, paper, and plastics. The result shows that the potential heating value for the waste was 35.04 MJ/kg Thermal gravimetric analysis (TGA) at a temperature range of 30-800 ° C showed only 1.39% leftover food, but mass decline at 30-110 ° C occurred quite slowly due to high air content. The optimum combustion temperature for paper, plastic, and garden waste are 317-430°C, 404.5-447.15°C, and 251.78-479.9°C, respectively. The total heating value obtained was equivalent to the electrical energy of 6635.2 GWh/year in 2025. A 1-tailed ANOVA analysis with a significance of 90% parameters of water content, carbon (C) composition, hydrogen composition (H), and oxygen composition (O) presented significances of 0.090; 0.005; 0.003; and 0.037, respectively.
- 11 October 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 88 (1) , 12-23
Open AccessRefuse Derived Fuel for Energy Recovery by Thermal Processes. A Case Study in Depok City, Indonesia
The number of words should not exceed 350. Depok City is one of Indonesia's big cities, which is currently focused on processing waste-to-energy. This research was conducted to study and describe waste management in Depok City to become renewable energy. Secondary data from the Depok City local government's inventory was used to determine the generation and composition of municipal solid waste (MSW). The waste's characterization was taken from the material recovery facility of Depok City, located at Jalan Merdeka. The amount of waste generated in Depok City is predicted to reach 681.612 tons/year by 2025. The significant waste composition items were food waste, garden waste, textiles, paper, and plastics. The result shows that the potential heating value for the waste was 35.04 MJ/kg Thermal gravimetric analysis (TGA) at a temperature range of 30-800 ° C showed only 1.39% leftover food, but mass decline at 30-110 ° C occurred quite slowly due to high air content. The optimum combustion temperature for paper, plastic, and garden waste are 317-430°C, 404.5-447.15°C, and 251.78-479.9°C, respectively. The total heating value obtained was equivalent to the electrical energy of 6635.2 GWh/year in 2025. A 1-tailed ANOVA analysis with a significance of 90% parameters of water content, carbon (C) composition, hydrogen composition (H), and oxygen composition (O) presented significances of 0.090; 0.005; 0.003; and 0.037, respectively.