Simo Kilpeläinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Simo Kilpeläinen has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Risto Kosonen
Aalto University
23 shared publications - Sami Lestinen
Department of Mechanical Engineering, School of Engineering, Aalto University, 02150 Espoo, Finland
13 shared publications - Weixin Zhao
Department of Mechanical Engineering, Aalto University, 02150 Espoo, Finland
11 shared publications - Juha Jokisalo
Aalto University
9 shared publications - Panu Mustakallio
Department of Mechanical Engineering, Aalto University, 02150 Espoo, Finland
9 shared publications - Minzhou Chen
Aalto University
5 shared publications
Latest Publications
- 2 January 2026
- Published by Springer Nature
- p. 841-850
Facial Skin Temperature as an Indicator of Thermal Comfort in Older Adults: An Infrared Thermography Study
- 2 January 2026
- Published by Springer Nature
- p. 841-850
Facial Skin Temperature as an Indicator of Thermal Comfort in Older Adults: An Infrared Thermography Study
- 2 January 2026
- Published by Springer Nature
- p. 482-490
Experimental Assessment of Airborne Transmission in a Meeting Room Equipped with Mixing and Displacement Ventilation
- 2 January 2026
- Published by Springer Nature
- p. 482-490
Experimental Assessment of Airborne Transmission in a Meeting Room Equipped with Mixing and Displacement Ventilation
- Open Access
- 20 December 2025
- Published by Elsevier in Building and Environment
- Vol. 290
The impact of different air distribution and extraction strategies on the mitigation of airborne infection risk in classroom settings
- 20 December 2025
- Published by Elsevier in Building and Environment
- Vol. 290
Open AccessThe impact of different air distribution and extraction strategies on the mitigation of airborne infection risk in classroom settings
- 23 August 2024
- Published by Elsevier in Building and Environment
- Vol. 265
Experimental comparison of structural and active protective methods against breath- and cough-borne aerosols in a meeting room
- 23 August 2024
- Published by Elsevier in Building and Environment
- Vol. 265
Experimental comparison of structural and active protective methods against breath- and cough-borne aerosols in a meeting room
- 24 June 2024
- Published by Elsevier in Energy and Buildings
- Vol. 318
Enhancing thermal comfort of older adults during extreme weather: Combined personal comfort system and ventilated vest
- 24 June 2024
- Published by Elsevier in Energy and Buildings
- Vol. 318
Enhancing thermal comfort of older adults during extreme weather: Combined personal comfort system and ventilated vest
- Open Access
An Experimental Study on the Efficacy of Local Exhaust Systems for the Mitigation of Exhaled Contaminants in a Meeting Room
In industrial applications, local exhaust systems have been used extensively for capturing and confining contaminants at their source. The present study investigates the efficacy of these systems in mitigating the spread of exhaled pollutants by combining them with mixing and displacement ventilation. Experiments were conducted in a simulated meeting room with six closely situated workstations, featuring five exposed persons (simulated with heated dummies) and one infected person (simulated with a breathing manikin). Six overhead local exhaust units, merged with panels, corresponding to workstations, were installed using a lowered false ceiling. Additionally, a table plenum setting for air inlets was introduced to enhance displacement ventilation effectiveness along with local exhaust systems. Results from 16 experimental cases are presented, using the local air quality index and ventilation effectiveness in the breathing zone. The local exhaust system improved the local air quality at the measuring locations closest to the infector in almost all test scenarios. The improvement, particularly significant with displacement ventilation, marked a maximum 35% increase in the local air quality index adjacent to the infector and 25% in the entire breathing zone of the tested meeting room. Moreover, the table plenum settings, coupled with displacement ventilation, further enhanced conditions in the breathing zone. Under the specific conditions of this investigation, the number of operational local exhausts had a marginal impact on mixing ventilation but a significant one on displacement ventilation tests. The efficacy of local exhaust systems was also influenced by the levels of heat gains present in the room. Overall, the study aims to contribute to ongoing efforts to identify sustainable solutions to mitigate indoor airborne diseases with a combination of supply and local exhaust units.
Open AccessAn Experimental Study on the Efficacy of Local Exhaust Systems for the Mitigation of Exhaled Contaminants in a Meeting Room
In industrial applications, local exhaust systems have been used extensively for capturing and confining contaminants at their source. The present study investigates the efficacy of these systems in mitigating the spread of exhaled pollutants by combining them with mixing and displacement ventilation. Experiments were conducted in a simulated meeting room with six closely situated workstations, featuring five exposed persons (simulated with heated dummies) and one infected person (simulated with a breathing manikin). Six overhead local exhaust units, merged with panels, corresponding to workstations, were installed using a lowered false ceiling. Additionally, a table plenum setting for air inlets was introduced to enhance displacement ventilation effectiveness along with local exhaust systems. Results from 16 experimental cases are presented, using the local air quality index and ventilation effectiveness in the breathing zone. The local exhaust system improved the local air quality at the measuring locations closest to the infector in almost all test scenarios. The improvement, particularly significant with displacement ventilation, marked a maximum 35% increase in the local air quality index adjacent to the infector and 25% in the entire breathing zone of the tested meeting room. Moreover, the table plenum settings, coupled with displacement ventilation, further enhanced conditions in the breathing zone. Under the specific conditions of this investigation, the number of operational local exhausts had a marginal impact on mixing ventilation but a significant one on displacement ventilation tests. The efficacy of local exhaust systems was also influenced by the levels of heat gains present in the room. Overall, the study aims to contribute to ongoing efforts to identify sustainable solutions to mitigate indoor airborne diseases with a combination of supply and local exhaust units.
- Open Access
- 9 April 2024
- Published by Elsevier in Building and Environment
- Vol. 256
An experimental study on airborne transmission in a meeting room with different air distribution methods
- 9 April 2024
- Published by Elsevier in Building and Environment
- Vol. 256
Open AccessAn experimental study on airborne transmission in a meeting room with different air distribution methods
- 30 November 2023
- Published by Elsevier in Building and Environment
- Vol. 248
A novel personal comfort system for older adults in hot conditions: Design, modelling, and performance
- 30 November 2023
- Published by Elsevier in Building and Environment
- Vol. 248
A novel personal comfort system for older adults in hot conditions: Design, modelling, and performance
- Open Access
- 12 October 2023
- Published by Elsevier in Building and Environment
- Vol. 245
Exploring the potential to mitigate airborne transmission risks with convective and radiant cooling systems in an office
- 12 October 2023
- Published by Elsevier in Building and Environment
- Vol. 245
Open AccessExploring the potential to mitigate airborne transmission risks with convective and radiant cooling systems in an office
- Open Access
Risk of Microbial Growth in Ventilation Ductwork Located in the Humid and Cold Conditions
High humidity inside ductworks could be a potential risk for microbial growth and there is also a hypothesis that lower night-time ventilation increases the risk of growth. This study investigates the possibility of microbial growth in ventilation ductwork exposed to humid and cold conditions. Two different typical night-time ventilation strategies for public buildings were investigated: ventilation rate was either continuously the same (0.15 L/s, m2) or no airflow during the night-time. Experimental data were collected over a four-month period. In the experiment, microbial media was released inside the ductwork initially. During the test period, air temperature and relative humidity inside the ductwork were controlled between 11–14 °C and 70–90%. Wipe, swab and air samples were taken at the beginning, monthly and at the end of the test period. The study results showed the extinction of colonies by the end of the experiment regardless of the chosen night-time ventilation strategy. The colony count in the air was low throughout the study period. Therefore, the results indicate that the long-term growth on the walls of air ducts is unlikely and the risk of microbial transfer from the air ductworks to room space is low.
Open AccessRisk of Microbial Growth in Ventilation Ductwork Located in the Humid and Cold Conditions
High humidity inside ductworks could be a potential risk for microbial growth and there is also a hypothesis that lower night-time ventilation increases the risk of growth. This study investigates the possibility of microbial growth in ventilation ductwork exposed to humid and cold conditions. Two different typical night-time ventilation strategies for public buildings were investigated: ventilation rate was either continuously the same (0.15 L/s, m2) or no airflow during the night-time. Experimental data were collected over a four-month period. In the experiment, microbial media was released inside the ductwork initially. During the test period, air temperature and relative humidity inside the ductwork were controlled between 11–14 °C and 70–90%. Wipe, swab and air samples were taken at the beginning, monthly and at the end of the test period. The study results showed the extinction of colonies by the end of the experiment regardless of the chosen night-time ventilation strategy. The colony count in the air was low throughout the study period. Therefore, the results indicate that the long-term growth on the walls of air ducts is unlikely and the risk of microbial transfer from the air ductworks to room space is low.