Stefan Harrer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stefan Harrer has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Jianbin Tang
IBM Australia Melbourne Victoria Australia
4 shared publications - Subhrajit Roy
Google Research, London, UK
3 shared publications - Bhavna Josephine Antony
Alfred Health, Melbourne, Australia
2 shared publications Jianbin Tang
IBM Research Australia
2 shared publications- Liming Zhu
Data61, CSIRO, Sydney, NSW, Australia
2 shared publications - Mahtab Mirmomeni
IBM Research Australia Melbourne Victoria Australia
2 shared publications
Latest Publications
- 17 February 2025
- Published by International Science Council
Preparing National Research Ecosystems for AI – second edition
The report offers a comprehensive analysis of the integration of artificial intelligence in science and research across various countries. It addresses both the advancements made and the challenges faced in this field, making it a valuable read for science leaders, policy-makers, AI professionals, and academics.
- 17 February 2025
- Published by International Science Council
Preparing National Research Ecosystems for AI – second edition
The report offers a comprehensive analysis of the integration of artificial intelligence in science and research across various countries. It addresses both the advancements made and the challenges faced in this field, making it a valuable read for science leaders, policy-makers, AI professionals, and academics.
- Open Access
- 15 November 2024
- Published by Elsevier in Journal of Systems and Software
- Vol. 220
Agent design pattern catalogue: A collection of architectural patterns for foundation model based agents
- 15 November 2024
- Published by Elsevier in Journal of Systems and Software
- Vol. 220
Open AccessAgent design pattern catalogue: A collection of architectural patterns for foundation model based agents
- Open Access
- 8 November 2024
- Published by Elsevier in EBioMedicine
- Vol. 109, 105446
Generative AI agents are transforming biology research: high resolution functional genome annotation for multiscale understanding of life
- 8 November 2024
- Published by Elsevier in EBioMedicine
- Vol. 109, 105446
Open AccessGenerative AI agents are transforming biology research: high resolution functional genome annotation for multiscale understanding of life
- Top Cited PapersOpen Access
Artificial intelligence‐enhanced epileptic seizure detection by wearables
Objective: Wrist‐ or ankle‐worn devices are less intrusive than the widely used electroencephalographic (EEG) systems for monitoring epileptic seizures. Using custom‐developed deep‐learning seizure detection models, we demonstrate the detection of a broad range of seizure types by wearable signals.Methods: Patients admitted to the epilepsy monitoring unit were enrolled and asked to wear wearable sensors on either wrists or ankles. We collected patients' electrodermal activity, accelerometry (ACC), and photoplethysmography, from which blood volume pulse (BVP) is derived. Board‐certified epileptologists determined seizure onset, offset, and types using video and EEG recordings per the International League Against Epilepsy 2017 classification. We applied three neural network models—a convolutional neural network (CNN) and a CNN–long short‐term memory (LSTM)‐based generalized detection model and an autoencoder‐based personalized detection model—to the raw time‐series sensor data to detect seizures and utilized performance measures, including sensitivity, false positive rate (the number of false alarms divided by the total number of nonseizure segments), number of false alarms per day, and detection delay. We applied a 10‐fold patientwise cross‐validation scheme to the multisignal biosensor data and evaluated model performance on 28 seizure types.Results: We analyzed 166 patients (47.6% female, median age = 10.0 years) and 900 seizures (13 254 h of sensor data) for 28 seizure types. With a CNN‐LSTM‐based seizure detection model, ACC, BVP, and their fusion performed better than chance; ACC and BVP data fusion reached the best detection performance of 83.9% sensitivity and 35.3% false positive rate. Nineteen of 28 seizure types could be detected by at least one data modality with area under receiver operating characteristic curve > .8 performance.Significance: Results from this in‐hospital study contribute to a paradigm shift in epilepsy care that entails noninvasive seizure detection, provides time‐sensitive and accurate data on additional clinical seizure types, and proposes a novel combination of an out‐of‐the‐box monitoring algorithm with an individualized person‐oriented seizure detection approach.
Top Cited PapersOpen AccessArtificial intelligence‐enhanced epileptic seizure detection by wearables
Objective: Wrist‐ or ankle‐worn devices are less intrusive than the widely used electroencephalographic (EEG) systems for monitoring epileptic seizures. Using custom‐developed deep‐learning seizure detection models, we demonstrate the detection of a broad range of seizure types by wearable signals.Methods: Patients admitted to the epilepsy monitoring unit were enrolled and asked to wear wearable sensors on either wrists or ankles. We collected patients' electrodermal activity, accelerometry (ACC), and photoplethysmography, from which blood volume pulse (BVP) is derived. Board‐certified epileptologists determined seizure onset, offset, and types using video and EEG recordings per the International League Against Epilepsy 2017 classification. We applied three neural network models—a convolutional neural network (CNN) and a CNN–long short‐term memory (LSTM)‐based generalized detection model and an autoencoder‐based personalized detection model—to the raw time‐series sensor data to detect seizures and utilized performance measures, including sensitivity, false positive rate (the number of false alarms divided by the total number of nonseizure segments), number of false alarms per day, and detection delay. We applied a 10‐fold patientwise cross‐validation scheme to the multisignal biosensor data and evaluated model performance on 28 seizure types.Results: We analyzed 166 patients (47.6% female, median age = 10.0 years) and 900 seizures (13 254 h of sensor data) for 28 seizure types. With a CNN‐LSTM‐based seizure detection model, ACC, BVP, and their fusion performed better than chance; ACC and BVP data fusion reached the best detection performance of 83.9% sensitivity and 35.3% false positive rate. Nineteen of 28 seizure types could be detected by at least one data modality with area under receiver operating characteristic curve > .8 performance.Significance: Results from this in‐hospital study contribute to a paradigm shift in epilepsy care that entails noninvasive seizure detection, provides time‐sensitive and accurate data on additional clinical seizure types, and proposes a novel combination of an out‐of‐the‐box monitoring algorithm with an individualized person‐oriented seizure detection approach.
- Open Access
- 16 June 2023
- Published by Elsevier in EBioMedicine
- Vol. 93, 104672
Response to M. Trengove & coll regarding “Attention is not all you need: the complicated case of ethically using large language models in healthcare and medicine”
- 16 June 2023
- Published by Elsevier in EBioMedicine
- Vol. 93, 104672
Open AccessResponse to M. Trengove & coll regarding “Attention is not all you need: the complicated case of ethically using large language models in healthcare and medicine”
- Top Cited PapersOpen Access
- 15 March 2023
- Published by Elsevier in EBioMedicine
- Vol. 90, 104512
Attention is not all you need: the complicated case of ethically using large language models in healthcare and medicine
- 15 March 2023
- Published by Elsevier in EBioMedicine
- Vol. 90, 104512
Top Cited PapersOpen AccessAttention is not all you need: the complicated case of ethically using large language models in healthcare and medicine
- 1 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 40, 142-147
Preictal onset detection through unsupervised clustering for epileptic seizure prediction
Epilepsy is a common neurological disorder characterized by recurrent epileptic seizures. These seizures have different intensities and might lead to accidents or, in the worst case, to sudden death. Therefore, being able to predict epileptic seizures would allow patients to be prepared, reducing the risk of injury. This paper focuses on epileptic seizure prediction using EEG (Electroencephalogram) signals. In contrast to the standard approach where the preictal state is assumed to have a constant duration in all the seizures of a patient, we propose a new method that labels each seizure individually exploiting clustering. Our labeling approach, which was applicable for 38% of the selected seizures, results in substantial improvements compared to the standard one. In fact, it reduces noise in the labels and improves the performance of the binary classifier used to distinguish the interictal and preictal states. Hence, our results suggest that the preictal duration is seizure-specific, not only patient-specific. Finally, we show that our method is able to predict 17 out of 18 (94%) seizures between 15 and 85 minutes, before seizure onset.
- 1 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 40, 142-147
Preictal onset detection through unsupervised clustering for epileptic seizure prediction
Epilepsy is a common neurological disorder characterized by recurrent epileptic seizures. These seizures have different intensities and might lead to accidents or, in the worst case, to sudden death. Therefore, being able to predict epileptic seizures would allow patients to be prepared, reducing the risk of injury. This paper focuses on epileptic seizure prediction using EEG (Electroencephalogram) signals. In contrast to the standard approach where the preictal state is assumed to have a constant duration in all the seizures of a patient, we propose a new method that labels each seizure individually exploiting clustering. Our labeling approach, which was applicable for 38% of the selected seizures, results in substantial improvements compared to the standard one. In fact, it reduces noise in the labels and improves the performance of the binary classifier used to distinguish the interictal and preictal states. Hence, our results suggest that the preictal duration is seizure-specific, not only patient-specific. Finally, we show that our method is able to predict 17 out of 18 (94%) seizures between 15 and 85 minutes, before seizure onset.
- Open Access
Features importance in seizure classification using scalp EEG reduced to single timeseries
Seizure detection and seizure-type classification are best performed using intra-cranial or full-scalp electroencephalogram (EEG). In embedded wearable systems however, recordings from only a few electrodes are available, reducing the spatial resolution of the signals to a handful of timeseries at most. Taking this constraint into account, we tested the performance of multiple classifiers using a subset of the EEG recordings by selecting a single trace from the montage or performing a dimensionality reduction over each hemispherical space. Our results support that Random Forest (RF) classifiers lead most ef-ficient and stable classification performances over Support Vector Machines (SVM). Interestingly, tracking the feature importances using permutation tests reveals that classical EEG spectrum power bands display different rankings across the classifiers: low frequencies (delta, theta) are most important for SVMs while higher frequencies (alpha, gamma) are more relevant for RF and Decision Trees. We reach up to 94.3% ∓ 5.3% accuracy in classifying absence from tonic-clonic seizures using state-of-art sampling methods for unbalanced datasets and leave-patients-out fold cross-validation policy.
Open AccessFeatures importance in seizure classification using scalp EEG reduced to single timeseries
Seizure detection and seizure-type classification are best performed using intra-cranial or full-scalp electroencephalogram (EEG). In embedded wearable systems however, recordings from only a few electrodes are available, reducing the spatial resolution of the signals to a handful of timeseries at most. Taking this constraint into account, we tested the performance of multiple classifiers using a subset of the EEG recordings by selecting a single trace from the montage or performing a dimensionality reduction over each hemispherical space. Our results support that Random Forest (RF) classifiers lead most ef-ficient and stable classification performances over Support Vector Machines (SVM). Interestingly, tracking the feature importances using permutation tests reveals that classical EEG spectrum power bands display different rankings across the classifiers: low frequencies (delta, theta) are most important for SVMs while higher frequencies (alpha, gamma) are more relevant for RF and Decision Trees. We reach up to 94.3% ∓ 5.3% accuracy in classifying absence from tonic-clonic seizures using state-of-art sampling methods for unbalanced datasets and leave-patients-out fold cross-validation policy.
- Open Access
Seizure detection using wearable sensors and machine learning: Setting a benchmark
Objective: Tracking seizures is crucial for epilepsy monitoring and treatment evaluation. Current epilepsy care relies on caretaker seizure diaries, but clinical seizure monitoring may miss seizures. Wearable devices may be better tolerated and more suitable for long‐term ambulatory monitoring. This study evaluates the seizure detection performance of custom‐developed machine learning (ML) algorithms across a broad spectrum of epileptic seizures utilizing wrist‐ and ankle‐worn multisignal biosensors.Methods: We enrolled patients admitted to the epilepsy monitoring unit and asked them to wear a wearable sensor on either their wrists or ankles. The sensor recorded body temperature, electrodermal activity, accelerometry (ACC), and photoplethysmography, which provides blood volume pulse (BVP). We used electroencephalographic seizure onset and offset as determined by a board‐certified epileptologist as a standard comparison. We trained and validated ML for two different algorithms: Algorithm 1, ML methods for developing seizure type‐specific detection models for nine individual seizure types; and Algorithm 2, ML methods for building general seizure type‐agnostic detection, lumping together all seizure types.Results: We included 94 patients (57.4% female, median age = 9.9 years) and 548 epileptic seizures (11 066 h of sensor data) for a total of 930 seizures and nine seizure types. Algorithm 1 detected eight of nine seizure types better than chance (area under the receiver operating characteristic curve [AUC‐ROC] = .648–.976). Algorithm 2 detected all nine seizure types better than chance (AUC‐ROC = .642–.995); a fusion of ACC and BVP modalities achieved the best AUC‐ROC (.752) when combining all seizure types together.Significance: Automatic seizure detection using ML from multimodal wearable sensor data is feasible across a broad spectrum of epileptic seizures. Preliminary results show better than chance seizure detection. The next steps include validation of our results in larger datasets, evaluation of the detection utility tool for additional clinical seizure types, and integration of additional clinical information.
Open AccessSeizure detection using wearable sensors and machine learning: Setting a benchmark
Objective: Tracking seizures is crucial for epilepsy monitoring and treatment evaluation. Current epilepsy care relies on caretaker seizure diaries, but clinical seizure monitoring may miss seizures. Wearable devices may be better tolerated and more suitable for long‐term ambulatory monitoring. This study evaluates the seizure detection performance of custom‐developed machine learning (ML) algorithms across a broad spectrum of epileptic seizures utilizing wrist‐ and ankle‐worn multisignal biosensors.Methods: We enrolled patients admitted to the epilepsy monitoring unit and asked them to wear a wearable sensor on either their wrists or ankles. The sensor recorded body temperature, electrodermal activity, accelerometry (ACC), and photoplethysmography, which provides blood volume pulse (BVP). We used electroencephalographic seizure onset and offset as determined by a board‐certified epileptologist as a standard comparison. We trained and validated ML for two different algorithms: Algorithm 1, ML methods for developing seizure type‐specific detection models for nine individual seizure types; and Algorithm 2, ML methods for building general seizure type‐agnostic detection, lumping together all seizure types.Results: We included 94 patients (57.4% female, median age = 9.9 years) and 548 epileptic seizures (11 066 h of sensor data) for a total of 930 seizures and nine seizure types. Algorithm 1 detected eight of nine seizure types better than chance (area under the receiver operating characteristic curve [AUC‐ROC] = .648–.976). Algorithm 2 detected all nine seizure types better than chance (AUC‐ROC = .642–.995); a fusion of ACC and BVP modalities achieved the best AUC‐ROC (.752) when combining all seizure types together.Significance: Automatic seizure detection using ML from multimodal wearable sensor data is feasible across a broad spectrum of epileptic seizures. Preliminary results show better than chance seizure detection. The next steps include validation of our results in larger datasets, evaluation of the detection utility tool for additional clinical seizure types, and integration of additional clinical information.
- Open Access
- 1 April 2021
- Published by Elsevier in EBioMedicine
- Vol. 66, 103275
Evaluation of artificial intelligence systems for assisting neurologists with fast and accurate annotations of scalp electroencephalography data
- 1 April 2021
- Published by Elsevier in EBioMedicine
- Vol. 66, 103275
Open AccessEvaluation of artificial intelligence systems for assisting neurologists with fast and accurate annotations of scalp electroencephalography data