NMNicolò Zuccherini Martello

Nicolò Zuccherini Martello

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicolò Zuccherini Martello has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The acoustic and daylighting effects of external façade sun shading systems

    by Simone Secchi, Patrizio Fausti, Gianfranco Cellai, Martina Parente, Andrea Santoni, Nicolò Zuccherini Martello

    External sun shading devices are increasingly used in sustainable buildings to reduce the greenhouse effect in the summer and the glare effect due to direct solar irradiation through transparent surfaces. The acoustic effects of these devices have been investigated in recent studies that suggest the possibility of optimising these elements to improve acoustic comfort in indoor environments, even with open windows. Nevertheless, there are few studies that analyse the combined effect of these devices on acoustic attenuation and improved daylighting. In this paper, the results of acoustics and daylighting simulations are reported, considering different dimensions, distances of the louvres and orientations of the façade. The main results of previous works concerning the effect of lining the bottom side of each louvre with sound-absorbing material are also briefly summarised. The acoustic effects of different configurations of the louvres are evaluated in terms of Insertion Loss in the façade plane. For the lighting simulations (daylight factor, daylighting uniformity and daylight glare probability), the variation of the shielding effect is studied considering the spacing between the louvres and the orientation of the façade for different times and seasons for latitude in the South of Europe.


  • Open Access

    A Psychoacoustic Investigation on the Effect of External Shading Devices on Building Facades

    by Nicolò Zuccherini Martello, Francesco Aletta, Patrizio Fausti, Jian Kang, Simone Secchi

    Due to energetic and natural lighting factors, building facades often present external shading devices, but the acoustic properties of such devices have not yet been well studied. This study was carried out using a full-scale model of a portion of a shading device, in a semi-anechoic chamber, using traditional and sound absorbing louvres. The psychoacoustic effects produced by the shading system were evaluated through comparisons between averaged values of loudness, roughness and sharpness levels, as well as sound pressure levels as reference. Results highlighted that the sound absorbing shading device offers good attenuation in terms of loudness, roughness and sound pressure level, with a small reduction in sharpness. The traditional shading system studied does not efficiently reduce the analysed parameters, or even worsens the situation. Several analyses of variance were carried out, one for each situation studied. The sound source position and the louvres’ tilt angle both produce statistically significant effects on almost all of the variations of the parameters studied. The analyses of the partial eta squared factors highlighted that source position and louvre tilt angle affect the variations of the parameters studied to a different degree in respect of the two types of louvres.


  • Noise generated from large construction sites: Measurements and possible mitigations

    by Patrizio Fausti, Maria C. Guerra, Andrea Santoni, N. Zuccherini Martello, Renzo Cremonini, G. Scalpelli Quiqueto, Pierpaolo Campostrini, Caterina Dabalà, Marco Caniato

    In this study, the issue of noise arising from the activities of large construction sites is analysed. The problem is particularly significant when the sites are close to protected natural areas or to residential areas and also when the duration of the construction works is very large. The case of the construction of a mobile barrier system, known as the MoSE, for the safeguard of the city of Venice from intruding tidal waters, is here reported. Since the early beginning of the construction activities, in April 2005, noise emission monitoring was conducted in order to evaluate possible effects on the presence of bird communities in the surrounding areas and also to evaluate the noise disturbance in some of the residential buildings close to the sites. During the monitoring activity, it was possible to measure the noise levels, the noise spectra and spectrograms in real-time and occasionally even the audio signal for particular activities was recorded. The analysis of data collected in different periods defined the pile driving and some other activities as the most significant from the standpoint of noise emission, therefore the possibility to mitigate their emission was investigated.


  • Open Access

    The Use of Sound Absorbing Shading Systems for the Attenuation of Noise on Building Façades. An Experimental Investigation

    by Nicolò Zuccherini Martello, Patrizio Fausti, Andrea Santoni, Simone Secchi

    The problem of solar irradiation in building façades with large windows is often solved with the use of external shading devices, such as brise-soleil systems, but their potential acoustic effects on building façades are usually neglected. The purpose of this work is a preliminary consideration of the acoustic behaviour of brise-soleil systems and, furthermore, the evaluation of the possibility to improve their performances, in terms of Sound Pressure Level (SPL) abatement over glass surfaces. The paper reports the results of a study on two portions of the same office building, with shading devices installed in front of large windows. Both airborne sound insulation measurements and SPL measurements over the glass surfaces of the windows were carried out to compare different situations, with or without louvers, and with sound absorbing experimental louvers as well. Results show that the louvers' presence can produce an increase in the SPL over the glass surface as a consequence of the reflection of the sound. Results further show that sound absorbing louvers improve the noise protection of the system, in terms of the SPL reduction, over glass surfaces, cancelling out the negative effect of the standard shading devices.


  • Sound Transmission between Rooms with Curtain Wall Façades: A Case Study

    by Simone Secchi, Gianfranco Cellai, Patrizio Fausti, Andrea Santoni, Nicolò Zuccherini Martello

    Curtain walls have reached good performances in terms of façade sound and thermal insulation, as well as solar protection. Nevertheless, the sound insulation performance of the partition between adjoining rooms with continuous curtain wall façades is often reduced by the presence of direct and flanking transmission through the junction with the façade itself. In this work, flanking and direct structural transmissions are analysed with reference to the joints of the mullion of the curtain wall with lightweight plasterboard partitions. Airborne sound insulation and vibration measurements were made in two adjacent rooms affected by the acoustic problems determined by the curtain wall joint. Traditional acoustic measurements, carried out according to EN ISO 16283–1, highlighted problems in sound insulation between rooms, but without any indication on different sound transmission paths through the wall. Vibration measurements were made for every part of the system (frame columns and beams, window panes, plasterboard wall, plasterboard false ceiling, etc.) to better understand the sound transmission paths in these kinds of structures. In this paper the results of this analysis are presented. Moreover, taking into account previous works and measurements made in this research field, different solutions for curtain wall structures are analysed and technical suggestions are given to improve airborne sound insulation between rooms separated by partitions mounted up to metal frames.


  • Open Access

    Analysis of Direct and Flanking Sound Transmission Between Rooms with Curtain Wall Facades

    by N. Zuccherini Martello, S. Secchi, P. Fausti, G. Cellai, A. Santoni