Sevki Demirbas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sevki Demirbas has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Sertac Bayhan
Department of Automation and Electronics, Gazi University, Ankara, 06300, Turkey
7 shared publications- Erol Kurt
Gazi University
4 shared publications Hikmet Fidanboy
Department of Electrics, Technical Sciences Vocational School, Gazi University, Ankara, Turkey
3 shared publicationsIlhan Garip
Strategy and Development Department, TRT, Ankara, Turkey
3 shared publications- Oguz Alkul
Gazı University
3 shared publications - Ramazan Bayindir
Gazi Üniversitesi
3 shared publications
Latest Publications
- Open Access
In Situ Series Resistance Estimation of an Off-Grid PV String by Charge-Controller Actuation: A Feasibility Case Study Within a Digital Twin Framework
Series resistance (Rs) is one of the most informative single parameters for the state of health of a photovoltaic (PV) string. Determining it without a curve tracer or interrupting production remains difficult, because maximum power point (MPP) tracking (MPPT) confines operation near the MPP. This study proposes a procedure in which the digital twin (DT) of an off-grid PV string with battery storage commands a scheduled, condition-gated current-voltage (I–V) sweep from the MPP toward open circuit through the current-limit register of the commercial charge controller. The reduced power continues to charge the battery. The single-diode model is fitted with the ideality factor and shunt resistance held fixed; the string-level Rs, inclusive of the DC cabling, is obtained by Levenberg–Marquardt iteration. In two measurement periods on the same four-module string, added series resistances of 0.33 to 1.18 Ω were recovered within 8% with a pooled regression slope of 0.97. Twelve clear-sky baseline sweeps over eight days agreed with a sample scatter of 3.4%. Feeding the in situ Rs back into the twin raised the operating power mean absolute percentage error (MAPE) from 7.1% to 12.9% when substituted alone and reduced it to 4.7% when the companion parameters were refit. A sweep takes about 144 s, costs about 5 Wh, roughly 0.1% of the daily yield. The results are limited to a single string at a single site and are presented as a feasibility study.
Open AccessIn Situ Series Resistance Estimation of an Off-Grid PV String by Charge-Controller Actuation: A Feasibility Case Study Within a Digital Twin Framework
Series resistance (Rs) is one of the most informative single parameters for the state of health of a photovoltaic (PV) string. Determining it without a curve tracer or interrupting production remains difficult, because maximum power point (MPP) tracking (MPPT) confines operation near the MPP. This study proposes a procedure in which the digital twin (DT) of an off-grid PV string with battery storage commands a scheduled, condition-gated current-voltage (I–V) sweep from the MPP toward open circuit through the current-limit register of the commercial charge controller. The reduced power continues to charge the battery. The single-diode model is fitted with the ideality factor and shunt resistance held fixed; the string-level Rs, inclusive of the DC cabling, is obtained by Levenberg–Marquardt iteration. In two measurement periods on the same four-module string, added series resistances of 0.33 to 1.18 Ω were recovered within 8% with a pooled regression slope of 0.97. Twelve clear-sky baseline sweeps over eight days agreed with a sample scatter of 3.4%. Feeding the in situ Rs back into the twin raised the operating power mean absolute percentage error (MAPE) from 7.1% to 12.9% when substituted alone and reduced it to 4.7% when the companion parameters were refit. A sweep takes about 144 s, costs about 5 Wh, roughly 0.1% of the daily yield. The results are limited to a single string at a single site and are presented as a feasibility study.
- 31 December 2025
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 13 (4) , 1806-1819
Fotovoltaik Panel Dijital İkizi için Analitik Model ile Veri Odaklı Uzun Kısa Süreli Bellek Modelin Karşılaştırılması
Sistem izleme, enerji yönetimi, arıza tespiti ve sistem sağlığının değerlendirilmesi durumlarında dijital ikiz yöntemlerinin önemi her geçen gün artmaktadır. Çevre kirliliği ve küresel ısınma ile yenilenebilir enerji sistemlerinin yaygınlaşmasından dolayı fotovoltaik (FV) paneller, enerji sistemlerinin vazgeçilmez bir parçası haline gelmiştir. Hava şartlarının değişkenliği ve FV’lerin doğrusal olmaması gibi sebepler, FV sistemlerinin sıkı takip edilmesi zorunluluğunu doğurmaktadır. Dijital ikiz yöntemleri bu soruna yeni bir çözüm olarak ortaya çıkmaktadır. Dijital ikiz modelleme yöntemleri literatürde analitik yöntemler ve veri odaklı yöntemler olarak yer almaktadır. Analitik yöntemler, hızlı sonuç üretme ve doğrudan yaklaşımlar sunsa da sistem karmaşıklığı ve sistemlerin doğrusal olmaması, FV sistemlerinin modellenmesini zorlaştırmaktadır. Veri odaklı yöntemler, sistemlere özel sonuçlarda başarı sağlamasına karşın, her farklı sistem için ayrı eğitim gerekliliği, eğitim için yeterli veri elde etme ve verilerin işlenme zorluğu gibi sebeplerden dolayı sorunlar oluşturmaktadır. Bu çalışmada FV sistemleri için veri odaklı dijital ikiz ile analitik dijital ikiz arasında performans karşılaştırması yapılmıştır. Veri odaklı yöntem için uzun-kısa süreli bellek (LSTM), analitik yöntem için tek diyot modeli (SDM) kullanılmıştır. Yapılan deneysel çalışmalarda SDM tabanlı FV dijital ikiz yönteminin performansının R2=0,95’in üzerinde olduğu görülmüştür.
- 31 December 2025
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 13 (4) , 1806-1819
Fotovoltaik Panel Dijital İkizi için Analitik Model ile Veri Odaklı Uzun Kısa Süreli Bellek Modelin Karşılaştırılması
Sistem izleme, enerji yönetimi, arıza tespiti ve sistem sağlığının değerlendirilmesi durumlarında dijital ikiz yöntemlerinin önemi her geçen gün artmaktadır. Çevre kirliliği ve küresel ısınma ile yenilenebilir enerji sistemlerinin yaygınlaşmasından dolayı fotovoltaik (FV) paneller, enerji sistemlerinin vazgeçilmez bir parçası haline gelmiştir. Hava şartlarının değişkenliği ve FV’lerin doğrusal olmaması gibi sebepler, FV sistemlerinin sıkı takip edilmesi zorunluluğunu doğurmaktadır. Dijital ikiz yöntemleri bu soruna yeni bir çözüm olarak ortaya çıkmaktadır. Dijital ikiz modelleme yöntemleri literatürde analitik yöntemler ve veri odaklı yöntemler olarak yer almaktadır. Analitik yöntemler, hızlı sonuç üretme ve doğrudan yaklaşımlar sunsa da sistem karmaşıklığı ve sistemlerin doğrusal olmaması, FV sistemlerinin modellenmesini zorlaştırmaktadır. Veri odaklı yöntemler, sistemlere özel sonuçlarda başarı sağlamasına karşın, her farklı sistem için ayrı eğitim gerekliliği, eğitim için yeterli veri elde etme ve verilerin işlenme zorluğu gibi sebeplerden dolayı sorunlar oluşturmaktadır. Bu çalışmada FV sistemleri için veri odaklı dijital ikiz ile analitik dijital ikiz arasında performans karşılaştırması yapılmıştır. Veri odaklı yöntem için uzun-kısa süreli bellek (LSTM), analitik yöntem için tek diyot modeli (SDM) kullanılmıştır. Yapılan deneysel çalışmalarda SDM tabanlı FV dijital ikiz yönteminin performansının R2=0,95’in üzerinde olduğu görülmüştür.
- Open Access
- 19 December 2025
- Published by MDPI AG in Electronics
- Vol. 15 (1) , 10
A Hybrid Machine Learning Approach for Cyberattack Detection and Classification in SCADA Systems: A Hydroelectric Power Plant Application
SCADA systems, widely used in critical infrastructure, are becoming increasingly vulnerable to complex cyber threats, which can compromise national security. This study presents an artificial intelligence-based approach aimed at the early and reliable detection of cyberattacks against SCADA systems. The study physically scaled the SCADA communication architecture of a hydroelectric power plant and created a suitable test environment. In this environment, in addition to the benign normal state, attack scenarios such as Man-in-the-Middle (MITM), Denial-of-Service (DoS), and Command Injection were implemented while the process created for the system’s operation was running continuously. While the scenarios were being implemented, the SCADA system was monitored, and network data flow was collected and stored for later analysis. Basic machine learning algorithms, including KNN, Naive Bayes, Decision Trees, and Logistic Regression, were applied to the obtained data. Also, different combinations of these methods have been tested. The analysis results showed that the hybrid model, consisting of a Decision Tree and Logistic Regression, achieved the most successful results, with a 98.29% accuracy rate, an Area Under the Curve (AUC) value of 0.998, and a reasonably short detection time. The results demonstrate that the proposed approach can accurately classify various types of attacks on SCADA systems, providing an effective early warning mechanism suitable for field applications.
- 19 December 2025
- Published by MDPI AG in Electronics
- Vol. 15 (1) , 10
Open AccessA Hybrid Machine Learning Approach for Cyberattack Detection and Classification in SCADA Systems: A Hydroelectric Power Plant Application
SCADA systems, widely used in critical infrastructure, are becoming increasingly vulnerable to complex cyber threats, which can compromise national security. This study presents an artificial intelligence-based approach aimed at the early and reliable detection of cyberattacks against SCADA systems. The study physically scaled the SCADA communication architecture of a hydroelectric power plant and created a suitable test environment. In this environment, in addition to the benign normal state, attack scenarios such as Man-in-the-Middle (MITM), Denial-of-Service (DoS), and Command Injection were implemented while the process created for the system’s operation was running continuously. While the scenarios were being implemented, the SCADA system was monitored, and network data flow was collected and stored for later analysis. Basic machine learning algorithms, including KNN, Naive Bayes, Decision Trees, and Logistic Regression, were applied to the obtained data. Also, different combinations of these methods have been tested. The analysis results showed that the hybrid model, consisting of a Decision Tree and Logistic Regression, achieved the most successful results, with a 98.29% accuracy rate, an Area Under the Curve (AUC) value of 0.998, and a reasonably short detection time. The results demonstrate that the proposed approach can accurately classify various types of attacks on SCADA systems, providing an effective early warning mechanism suitable for field applications.
- Open Access
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 161762-161778
Model-Free Reinforcement Learning in Microgrid Control: A Review
The global shift toward distributed energy resources (DERs) has accelerated the deployment of microgrids (MGs), introducing unprecedented control challenges that traditional strategies often struggle to address. Model-free reinforcement learning (MFRL) has emerged as a promising paradigm for adaptive, intelligent control without the need for explicit system modeling. This paper presents a comprehensive review of MFRL applications in MG control, proposing a systematic taxonomy that classifies existing approaches by control hierarchy, architectural configuration, operational modes, and action spaces. We analyze critical design considerations—including reward function shaping, exploration strategies, and computational requirements—that influence practical deployment. Furthermore, we systematically evaluate key MFRL algorithms and map their suitability across primary, secondary, and tertiary control levels. By examining recent applications, we highlight that MFRL has reached considerable maturity across all control hierarchies, revealing clear trends: continuous-action methods excel in real-time primary control, distributed schemes enhance scalability in secondary coordination, and multi-agent frameworks enable complex tertiary-level optimization. Finally, the review identifies persistent implementation challenges and offers practical guidance for algorithm selection and deployment strategies in modern MG systems. This review aims to serve both researchers and practitioners seeking to deploy MFRL in modern MG systems.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 161762-161778
Open AccessModel-Free Reinforcement Learning in Microgrid Control: A Review
The global shift toward distributed energy resources (DERs) has accelerated the deployment of microgrids (MGs), introducing unprecedented control challenges that traditional strategies often struggle to address. Model-free reinforcement learning (MFRL) has emerged as a promising paradigm for adaptive, intelligent control without the need for explicit system modeling. This paper presents a comprehensive review of MFRL applications in MG control, proposing a systematic taxonomy that classifies existing approaches by control hierarchy, architectural configuration, operational modes, and action spaces. We analyze critical design considerations—including reward function shaping, exploration strategies, and computational requirements—that influence practical deployment. Furthermore, we systematically evaluate key MFRL algorithms and map their suitability across primary, secondary, and tertiary control levels. By examining recent applications, we highlight that MFRL has reached considerable maturity across all control hierarchies, revealing clear trends: continuous-action methods excel in real-time primary control, distributed schemes enhance scalability in secondary coordination, and multi-agent frameworks enable complex tertiary-level optimization. Finally, the review identifies persistent implementation challenges and offers practical guidance for algorithm selection and deployment strategies in modern MG systems. This review aims to serve both researchers and practitioners seeking to deploy MFRL in modern MG systems.
- 1 January 2025
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 13 (3)
Implementation of Battery-Integrated Transformerless High-Gain Smart Inverter
This study presents a novel battery-integrated, transformerless high-gain smart inverter model designed to enhance the efficiency and reliability of photovoltaic (PV) energy systems. The proposed system integrates an interleaved buck converter for battery charging and a transformerless high-gain DC-DC converter operating in parallel with the battery to supply the inverter source. Additionally, a two-level inverter is employed to ensure stable grid voltage generation. The model incorporates several required control strategies, including Maximum Power Point Tracking (MPPT) for optimal solar energy utilization, active and reactive power control for grid-connected operation, and voltage regulation for off-grid scenarios. The bidirectional energy flow capability enables seamless power distribution between the PV array, battery storage, and the electrical grid, ensuring enhanced system performance. Simulation results validate the efficiency and stability of the proposed inverter model, demonstrating improved power conversion, reduced energy losses, and enhanced system flexibility. By eliminating the need for a transformer, the design achieves higher efficiency and lower cost while maintaining operational reliability. This research contributes to the development of more sustainable and intelligent PV energy solutions, paving the way for improved energy management in renewable power systems.
- 1 January 2025
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 13 (3)
Implementation of Battery-Integrated Transformerless High-Gain Smart Inverter
This study presents a novel battery-integrated, transformerless high-gain smart inverter model designed to enhance the efficiency and reliability of photovoltaic (PV) energy systems. The proposed system integrates an interleaved buck converter for battery charging and a transformerless high-gain DC-DC converter operating in parallel with the battery to supply the inverter source. Additionally, a two-level inverter is employed to ensure stable grid voltage generation. The model incorporates several required control strategies, including Maximum Power Point Tracking (MPPT) for optimal solar energy utilization, active and reactive power control for grid-connected operation, and voltage regulation for off-grid scenarios. The bidirectional energy flow capability enables seamless power distribution between the PV array, battery storage, and the electrical grid, ensuring enhanced system performance. Simulation results validate the efficiency and stability of the proposed inverter model, demonstrating improved power conversion, reduced energy losses, and enhanced system flexibility. By eliminating the need for a transformer, the design achieves higher efficiency and lower cost while maintaining operational reliability. This research contributes to the development of more sustainable and intelligent PV energy solutions, paving the way for improved energy management in renewable power systems.
- Open Access
- 1 January 2025
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 15 (v15i2) , 343-352
Control of Grid Integrated PV Based Microgrid for Seamless Operation
Control of Grid Integrated PV Based Microgrid for Seamless Operation
- 1 January 2025
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 15 (v15i2) , 343-352
Open AccessControl of Grid Integrated PV Based Microgrid for Seamless Operation
Control of Grid Integrated PV Based Microgrid for Seamless Operation
- Open Access
- 25 May 2024
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 2024, 1-19
Long-Term Multiyear Transmission Expansion Planning in Turkish Power System
To sustain the clean energy transition without interruption and to ensure the reliable operation of the transmission system, it is required to have enough additional transmission capacity in the future horizons. The transmission expansion planning (TEP) problem is a core issue in deciding additional transmission capacity in the planning activities. TEP aims to find the best expansion plan while satisfying technical and economic constraints. In this study, a new binary version of the original FBI algorithm called the BFBI (binary forensic-based investigation) algorithm is developed to solve the binary TEP problem. The effectiveness and performance of the developed BFBI are assessed by implementing it in two different test systems: the standard Garver 6-bus test system and the modified 400 kV Turkish grid. Seasonal scenarios are created for 5- and 10-year planning periods to cover all possible generation and load conditions and to assess the impact of the increased share of RES on the grid in the TEP studies conducted for the modified 400 kV Turkish grid created as a bulk realistic grid. The TEP problem is solved by including investment, reliability, and operational costs in two different objective functions for cases while considering the N-1 contingency criterion. The efficacy and robustness of the BFBI algorithm are justified by comparing it with well-known algorithms such as GA and PSO.
- 25 May 2024
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 2024, 1-19
Open AccessLong-Term Multiyear Transmission Expansion Planning in Turkish Power System
To sustain the clean energy transition without interruption and to ensure the reliable operation of the transmission system, it is required to have enough additional transmission capacity in the future horizons. The transmission expansion planning (TEP) problem is a core issue in deciding additional transmission capacity in the planning activities. TEP aims to find the best expansion plan while satisfying technical and economic constraints. In this study, a new binary version of the original FBI algorithm called the BFBI (binary forensic-based investigation) algorithm is developed to solve the binary TEP problem. The effectiveness and performance of the developed BFBI are assessed by implementing it in two different test systems: the standard Garver 6-bus test system and the modified 400 kV Turkish grid. Seasonal scenarios are created for 5- and 10-year planning periods to cover all possible generation and load conditions and to assess the impact of the increased share of RES on the grid in the TEP studies conducted for the modified 400 kV Turkish grid created as a bulk realistic grid. The TEP problem is solved by including investment, reliability, and operational costs in two different objective functions for cases while considering the N-1 contingency criterion. The efficacy and robustness of the BFBI algorithm are justified by comparing it with well-known algorithms such as GA and PSO.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 72-77
A Review of Wind Energy Conversion Systems
In the last decade, wind energy as a renewable energy source has become increasingly popular, and the establishment of large-scale wind energy conversion systems (WECS) and its connection to the electricity grid has become common. However, conventional power systems are not directly compatible with the characteristics of wind turbines. In this article, different topologies and classification of wind turbine systems are examined and different wind energy conversion systems are discussed. The article focuses on the speed-based, output-based, generator-type-based and orientation-based classification of WECS. The typical structure and information of WECS are explained in detail. Fixed and variable WECS are compared and contrasted in the context of network stability. An overall review and comparison of different wind turbine generators in WECS are discussed. Finally, the balance problem for different wind turbine energy conversion systems in the grid network is presented and possible different mitigation methods and solutions are suggested.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 72-77
A Review of Wind Energy Conversion Systems
In the last decade, wind energy as a renewable energy source has become increasingly popular, and the establishment of large-scale wind energy conversion systems (WECS) and its connection to the electricity grid has become common. However, conventional power systems are not directly compatible with the characteristics of wind turbines. In this article, different topologies and classification of wind turbine systems are examined and different wind energy conversion systems are discussed. The article focuses on the speed-based, output-based, generator-type-based and orientation-based classification of WECS. The typical structure and information of WECS are explained in detail. Fixed and variable WECS are compared and contrasted in the context of network stability. An overall review and comparison of different wind turbine generators in WECS are discussed. Finally, the balance problem for different wind turbine energy conversion systems in the grid network is presented and possible different mitigation methods and solutions are suggested.
- Open Access
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (V12i4) , 1988-2001
Transmission Expansion Planning Using a Novel Meta-Heuristic Method
Transmission Expansion Planning Using a Novel Meta-Heuristic Method
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (V12i4) , 1988-2001
Open AccessTransmission Expansion Planning Using a Novel Meta-Heuristic Method
Transmission Expansion Planning Using a Novel Meta-Heuristic Method
- 17 May 2021
- Published by Springer Nature in Technology and Economics of Smart Grids and Sustainable Energy
- Vol. 6 (1) , 1-6
An Application of a Wireless Power Transfer at Low Frequency Range
- 17 May 2021
- Published by Springer Nature in Technology and Economics of Smart Grids and Sustainable Energy
- Vol. 6 (1) , 1-6
An Application of a Wireless Power Transfer at Low Frequency Range