Dusan Jovanovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dusan Jovanovic has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Ana Deletic
School of Civil and Environmental Engineering, University of New South Wales, Sydney, NSW 2052, Australia
7 shared publications - David T. McCarthy
Monash University
7 shared publications Jon Hathaway
Department of Civil and Environmental Engineering, The University of Tennessee, Knoxville, TN 37996, USA
3 shared publications- Rebekah Henry
School of Public Health and Preventive Medicine, Monash University, Clayton, VIC 3168, Australia
3 shared publications Rhys Coleman
3 shared publicationsAlfonso Mejía
Department of Civil and Environmental Engineering, Pennsylvania State University, University Park, PA 16802, USA
2 shared publications
Latest Publications
- Open Access
- 1 January 2021
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srpski medicinski casopis Lekarske komore
- Vol. 2 (3) , 213-219
COVID-19 prevention and control measures: Emergency center of the University Clinical Center of Serbia
In less than a year, humanity has managed to start a long and difficult battle against a virus, with a powerful weapon - the vaccine. In addition to vaccination, which is undoubtedly the most important measure in preventing COVID-19, our responsible behavior (wearing masks, hand hygiene, observing physical distance), especially in this period of an increase in the number of patients and the emergence of new strains, also remains an important measure in preventing and controlling the spread of COVID-19. In this paper, an overview of professional recommendations and instructions for the epidemiological surveillance of health care institutions is given. The study objective is to present the manner of organizing the epidemiological surveillance of the Epidemiology Department of the University Clinical Center of Serbia (UCCS) at the Emergency Center of the UCCS (EC-UCCS) as well as the application of measures to prevent and control COVID-19. To this end the method of the triage of patients with suspected COVID-19 in the Emergency Center of the UCCS has been shown. The Guidelines for the Rational Use of Personal Protective Equipment in Healthcare Facilities Depending on the Activities Performed, as well as the Recommendations of the Centers for Disease Prevention and Control (Atlanta, USA) have been presented. The Algorithm for the Procedures with Patients with Suspected and Proven COVID-19 Infection for Patients of the EC-UCCS has been formed. This Algorithm has been in use since March 1, 2020, in the EC-UCCS Admissions Service Triage Facility. In addition to this Algorithm, the screening of medical staff for SARS-CoV-2 has been performed by sampling nasopharyngeal and throat swabs (for PCR analysis and antigen tests) and blood (for serological analyses).
- 1 January 2021
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Srpski medicinski casopis Lekarske komore
- Vol. 2 (3) , 213-219
Open AccessCOVID-19 prevention and control measures: Emergency center of the University Clinical Center of Serbia
In less than a year, humanity has managed to start a long and difficult battle against a virus, with a powerful weapon - the vaccine. In addition to vaccination, which is undoubtedly the most important measure in preventing COVID-19, our responsible behavior (wearing masks, hand hygiene, observing physical distance), especially in this period of an increase in the number of patients and the emergence of new strains, also remains an important measure in preventing and controlling the spread of COVID-19. In this paper, an overview of professional recommendations and instructions for the epidemiological surveillance of health care institutions is given. The study objective is to present the manner of organizing the epidemiological surveillance of the Epidemiology Department of the University Clinical Center of Serbia (UCCS) at the Emergency Center of the UCCS (EC-UCCS) as well as the application of measures to prevent and control COVID-19. To this end the method of the triage of patients with suspected COVID-19 in the Emergency Center of the UCCS has been shown. The Guidelines for the Rational Use of Personal Protective Equipment in Healthcare Facilities Depending on the Activities Performed, as well as the Recommendations of the Centers for Disease Prevention and Control (Atlanta, USA) have been presented. The Algorithm for the Procedures with Patients with Suspected and Proven COVID-19 Infection for Patients of the EC-UCCS has been formed. This Algorithm has been in use since March 1, 2020, in the EC-UCCS Admissions Service Triage Facility. In addition to this Algorithm, the screening of medical staff for SARS-CoV-2 has been performed by sampling nasopharyngeal and throat swabs (for PCR analysis and antigen tests) and blood (for serological analyses).
- 1 February 2019
- Published by Elsevier in Estuarine, Coastal and Shelf Science
- Vol. 217, 9-27
Modelling shallow and narrow urban salt-wedge estuaries: Evaluation of model performance and sensitivity to optimise input data collection
- 1 February 2019
- Published by Elsevier in Estuarine, Coastal and Shelf Science
- Vol. 217, 9-27
Modelling shallow and narrow urban salt-wedge estuaries: Evaluation of model performance and sensitivity to optimise input data collection
- Open Access
- 29 June 2018
- Published by Copernicus GmbH in Hydrology and Earth System Sciences
- Vol. 22 (6) , 3551-3559
Technical note: Long-term persistence loss of urban streams as a metric for catchment classification
Urbanisation has been associated with a reduction in the long-term correlation within a streamflow series, quantified by the Hurst exponent (H). This presents an opportunity to use the H exponent as an index for the classification of catchments on a scale from natural to urbanised conditions. However, before using the H exponent as a general index, the relationship between this exponent and level of urbanisation needs to be further examined and verified on catchments with different levels of imperviousness and from different climatic regions. In this study, the H exponent is estimated for 38 (deseasonalised) mean daily runoff time series, 22 from the USA and 16 from Australia, using the traditional rescaled-range statistic (R∕S) and the more advanced multifractal detrended fluctuation analysis (MF-DFA). Relationships between H and catchment imperviousness, catchment size, annual rainfall and specific mean discharge were investigated. No clear relationship with catchment area was found, and a weak negative relationship with annual rainfall and specific mean streamflow was found only when the R∕S method was used. Conversely, both methods showed decreasing values of H as catchment imperviousness increased. The H exponent decreased from around 1.0 for catchments in natural conditions to around 0.6 for highly urbanised catchments. Three significantly different ranges of H exponents were identified, allowing catchments to be parsed into groups with imperviousness lower than 5 % (natural), catchments with imperviousness between 5 and 15 % (peri-urban) and catchments with imperviousness larger than 15 % (urban). The H exponent thus represents a useful metric to quantitatively assess the impact of catchment imperviousness on streamflow regime.
- 29 June 2018
- Published by Copernicus GmbH in Hydrology and Earth System Sciences
- Vol. 22 (6) , 3551-3559
Open AccessTechnical note: Long-term persistence loss of urban streams as a metric for catchment classification
Urbanisation has been associated with a reduction in the long-term correlation within a streamflow series, quantified by the Hurst exponent (H). This presents an opportunity to use the H exponent as an index for the classification of catchments on a scale from natural to urbanised conditions. However, before using the H exponent as a general index, the relationship between this exponent and level of urbanisation needs to be further examined and verified on catchments with different levels of imperviousness and from different climatic regions. In this study, the H exponent is estimated for 38 (deseasonalised) mean daily runoff time series, 22 from the USA and 16 from Australia, using the traditional rescaled-range statistic (R∕S) and the more advanced multifractal detrended fluctuation analysis (MF-DFA). Relationships between H and catchment imperviousness, catchment size, annual rainfall and specific mean discharge were investigated. No clear relationship with catchment area was found, and a weak negative relationship with annual rainfall and specific mean streamflow was found only when the R∕S method was used. Conversely, both methods showed decreasing values of H as catchment imperviousness increased. The H exponent decreased from around 1.0 for catchments in natural conditions to around 0.6 for highly urbanised catchments. Three significantly different ranges of H exponents were identified, allowing catchments to be parsed into groups with imperviousness lower than 5 % (natural), catchments with imperviousness between 5 and 15 % (peri-urban) and catchments with imperviousness larger than 15 % (urban). The H exponent thus represents a useful metric to quantitatively assess the impact of catchment imperviousness on streamflow regime.
- 1 December 2017
- Published by Elsevier in Journal of Hydrology
- Vol. 555, 129-140
Conceptual modelling of E. coli in urban stormwater drains, creeks and rivers
- 1 December 2017
- Published by Elsevier in Journal of Hydrology
- Vol. 555, 129-140
Conceptual modelling of E. coli in urban stormwater drains, creeks and rivers
- Open Access
- 24 October 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-12
Technical note: Long-term memory loss of urban streams as a metric for catchment classification
Urbanisation has been associated with a reduction in the long-term correlation within a streamflow series, quantified by the Hurst exponent (H). This presents an opportunity to use the H exponent as an index for the classification of catchments on a scale from natural to urbanised conditions. However, before using the H exponent as a general index, the relationship between this exponent and level of urbanisation needs to be further examined and verified on catchments with different levels of imperviousness and from different climatic regions. In this study, the H exponent is estimated for 38 (deseasonalized) mean daily runoff time series, 22 from the USA and 16 from Australia, using the traditional rescaled-range statistic (R/S) and the more advanced multi-fractal detrended fluctuation analysis (MF-DFA). Relationships between H and catchment imperviousness, catchment size, annual rainfall and specific mean discharge were investigated. No clear relationship with catchment area was found, and a weak negative relationship with annual rainfall and specific mean streamflow was found only when the R/S method was used. Conversely, both methods showed decreasing values of H as catchment imperviousness increased. The H exponent decreased from around 1.0 for catchments in natural conditions to around 0.6 for highly urbanised catchments. Three significantly different ranges of H exponents were identified, allowing catchments to be parsed into groups with imperviousness lower than 5 % (natural), catchments with imperviousness between 5 and 15 % (peri-urban), and catchments with imperviousness larger than 15 % (urban). The H exponent thus represents a useful metric to quantitatively assess the impact of catchment imperviousness on streamflow regime.
- 24 October 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-12
Open AccessTechnical note: Long-term memory loss of urban streams as a metric for catchment classification
Urbanisation has been associated with a reduction in the long-term correlation within a streamflow series, quantified by the Hurst exponent (H). This presents an opportunity to use the H exponent as an index for the classification of catchments on a scale from natural to urbanised conditions. However, before using the H exponent as a general index, the relationship between this exponent and level of urbanisation needs to be further examined and verified on catchments with different levels of imperviousness and from different climatic regions. In this study, the H exponent is estimated for 38 (deseasonalized) mean daily runoff time series, 22 from the USA and 16 from Australia, using the traditional rescaled-range statistic (R/S) and the more advanced multi-fractal detrended fluctuation analysis (MF-DFA). Relationships between H and catchment imperviousness, catchment size, annual rainfall and specific mean discharge were investigated. No clear relationship with catchment area was found, and a weak negative relationship with annual rainfall and specific mean streamflow was found only when the R/S method was used. Conversely, both methods showed decreasing values of H as catchment imperviousness increased. The H exponent decreased from around 1.0 for catchments in natural conditions to around 0.6 for highly urbanised catchments. Three significantly different ranges of H exponents were identified, allowing catchments to be parsed into groups with imperviousness lower than 5 % (natural), catchments with imperviousness between 5 and 15 % (peri-urban), and catchments with imperviousness larger than 15 % (urban). The H exponent thus represents a useful metric to quantitatively assess the impact of catchment imperviousness on streamflow regime.
- 1 June 2017
- Published by Elsevier in Marine Pollution Bulletin
- Vol. 119 (1) , 226-230
Tidal fluctuations influence E. coli concentrations in urban estuaries
- 1 June 2017
- Published by Elsevier in Marine Pollution Bulletin
- Vol. 119 (1) , 226-230
Tidal fluctuations influence E. coli concentrations in urban estuaries
- 1 February 2017
- Published by Elsevier in Water Research
- Vol. 109, 253-265
Source tracking using microbial community fingerprints: Method comparison with hydrodynamic modelling
- 1 February 2017
- Published by Elsevier in Water Research
- Vol. 109, 253-265
Source tracking using microbial community fingerprints: Method comparison with hydrodynamic modelling
- 1 January 2017
- Published by Elsevier in Marine Pollution Bulletin
- Vol. 114 (1) , 114-122
Spatial variability of E. coli in an urban salt-wedge estuary
- 1 January 2017
- Published by Elsevier in Marine Pollution Bulletin
- Vol. 114 (1) , 114-122
Spatial variability of E. coli in an urban salt-wedge estuary
- 15 July 2015
- Published by IWA Publishing in Water Science & Technology
- Vol. 72 (9) , 1472-1480
Integrated conceptual modelling of faecal contamination in an urban estuary catchment
Urban stormwater is regarded as a key input of faecal contamination in receiving water bodies and therefore, a major concern for health risks associated with aquatic recreation. Wastewater leakages, cross connections and overflows, together with faeces washed from surfaces during rainfall events, are possible origins of faecal contamination which enter these water bodies through stormwater drains. This paper applies conceptual models to a case study of the Yarra River estuary to understand the relative importance of fluxes derived from an urban creek and the 219 urban stormwater pipes which drain directly to the estuary as compared with other inputs, such as the Yarra River itself. Existing hydrologic-microorganism models were used for the estimation of the inputs from riverine and urban stormwater fluxes. These predictions were applied as boundary conditions for a new, highly simplified, model which accounts for the transport and survival of faecal microorganisms in the estuary. All models were calibrated using a rich dataset, containing over 2,000 measured Escherichia coli concentrations. Mass balances from the riverine and stormwater models indicate the limited influence of urban stormwater drains on the estuary during dry weather; less than 0.05% to 10% (5th and 95th percentile; median 0.5%) of the total daily E. coli load entering the estuary was derived from urban stormwater drains. While wet weather contributions from stormwater drains could be more significant (2% to 50%; 5th and 95th percentile), the average contribution remained marginal (median 10%). Sensitivity testing of the estuarine microorganism model by switching off stormwater boundary conditions resulted in minimal model efficiency reduction; this may reflect the low average daily contribution from urban stormwater drains. While these results confirm previous studies which show that E. coli loads derived from stormwater drains are dwarfed by other inputs, it is essential to note that these results also demonstrate that some conditions reveal the opposite; high proportions from stormwater are possible when combined with low riverine inputs and high urban rainfall. Furthermore, this study focuses on the overall impacts of direct urban stormwater inputs on the faecal contamination levels within the estuary, and localized impacts would certainly require further investigation.
- 15 July 2015
- Published by IWA Publishing in Water Science & Technology
- Vol. 72 (9) , 1472-1480
Integrated conceptual modelling of faecal contamination in an urban estuary catchment
Urban stormwater is regarded as a key input of faecal contamination in receiving water bodies and therefore, a major concern for health risks associated with aquatic recreation. Wastewater leakages, cross connections and overflows, together with faeces washed from surfaces during rainfall events, are possible origins of faecal contamination which enter these water bodies through stormwater drains. This paper applies conceptual models to a case study of the Yarra River estuary to understand the relative importance of fluxes derived from an urban creek and the 219 urban stormwater pipes which drain directly to the estuary as compared with other inputs, such as the Yarra River itself. Existing hydrologic-microorganism models were used for the estimation of the inputs from riverine and urban stormwater fluxes. These predictions were applied as boundary conditions for a new, highly simplified, model which accounts for the transport and survival of faecal microorganisms in the estuary. All models were calibrated using a rich dataset, containing over 2,000 measured Escherichia coli concentrations. Mass balances from the riverine and stormwater models indicate the limited influence of urban stormwater drains on the estuary during dry weather; less than 0.05% to 10% (5th and 95th percentile; median 0.5%) of the total daily E. coli load entering the estuary was derived from urban stormwater drains. While wet weather contributions from stormwater drains could be more significant (2% to 50%; 5th and 95th percentile), the average contribution remained marginal (median 10%). Sensitivity testing of the estuarine microorganism model by switching off stormwater boundary conditions resulted in minimal model efficiency reduction; this may reflect the low average daily contribution from urban stormwater drains. While these results confirm previous studies which show that E. coli loads derived from stormwater drains are dwarfed by other inputs, it is essential to note that these results also demonstrate that some conditions reveal the opposite; high proportions from stormwater are possible when combined with low riverine inputs and high urban rainfall. Furthermore, this study focuses on the overall impacts of direct urban stormwater inputs on the faecal contamination levels within the estuary, and localized impacts would certainly require further investigation.
- Open Access
- 9 February 2015
- Published by Frontiers Media SA in Frontiers in Microbiology
- Vol. 6, 74
Environmental monitoring of waterborne Campylobacter: evaluation of the Australian standard and a hybrid extraction-free MPN-PCR method
Campylobacter is the leading agent of diarrheal disease worldwide. This study evaluates a novel culture-PCR hybrid (MPN-PCR) assay for the rapid enumeration of Campylobacter spp. from estuarine and wastewater systems. To first evaluate the current, culture-based, Australian standard, an inter-laboratory study was conducted on 69 subsampled water samples. The proposed Most-Probable Number (MPN)-PCR method was then evaluated, by analysing 147 estuarine samples collected over a 2 year period. Data for 14 different biological, hydrological and climatic parameters were also collated to identify pathogen-environment relationships and assess the potential for method specific bias. The results demonstrated that the intra-laboratory performance of the MPN-PCR was superior to that of AS/NZS (σ = 0.7912, P < 0.001; κ = 0.701, P < 0.001) with an overall diagnostic accuracy of ~94%. Furthermore, the analysis of both MPN-PCR and AS/NZS identified the potential for the introduction of method specific bias during assessment of the effects of environmental parameters on Campylobacter spp. numbers.
- 9 February 2015
- Published by Frontiers Media SA in Frontiers in Microbiology
- Vol. 6, 74
Open AccessEnvironmental monitoring of waterborne Campylobacter: evaluation of the Australian standard and a hybrid extraction-free MPN-PCR method
Campylobacter is the leading agent of diarrheal disease worldwide. This study evaluates a novel culture-PCR hybrid (MPN-PCR) assay for the rapid enumeration of Campylobacter spp. from estuarine and wastewater systems. To first evaluate the current, culture-based, Australian standard, an inter-laboratory study was conducted on 69 subsampled water samples. The proposed Most-Probable Number (MPN)-PCR method was then evaluated, by analysing 147 estuarine samples collected over a 2 year period. Data for 14 different biological, hydrological and climatic parameters were also collated to identify pathogen-environment relationships and assess the potential for method specific bias. The results demonstrated that the intra-laboratory performance of the MPN-PCR was superior to that of AS/NZS (σ = 0.7912, P < 0.001; κ = 0.701, P < 0.001) with an overall diagnostic accuracy of ~94%. Furthermore, the analysis of both MPN-PCR and AS/NZS identified the potential for the introduction of method specific bias during assessment of the effects of environmental parameters on Campylobacter spp. numbers.