Fang Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fang Chen has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Fengshan Yu
Department of Chemistry, Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica , Huazhong University of Science and Technology , Wuhan, China
4 shared publicationsCengceng Zhang
Huazhong University of Science and Technology, School of Chemistry and Chemical Engineering, Ministry of Education, Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, Key laboratory of Material Chemistry for Energy Conversion and Storage (HUST), Wuhan, China, 430074
3 shared publicationsWeizhou Liu
College of Chemistry and Chemical Engineering
3 shared publicationsYan Liang
Key Laboratory for Large-Format Battery Materials and System (Ministry of Education), School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China
3 shared publicationsYuanyuan Yu
Huazhong University of Science and Technology, School of Chemistry and Chemical Engineering, Ministry of Education, Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, Key laboratory of Material Chemistry for Energy Conversion and Storage (HUST), Wuhan, China, 430074
3 shared publications- Biyun Fang
School of Basic Medical Sciences, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, 710061, China; Key Laboratory of Environment and Genes Related to Diseases, Xi'an Jiaotong University, Ministry of Education, Xi'an, Shaanxi, 710061, China
2 shared publications
Latest Publications
- Open Access
- 1 December 2023
- Published by Georg Thieme Verlag KG in Pharmaceutical Fronts
- Vol. 05 (04) , e297-e309
Quality by Design Approach for Development and Characterization of Granisetron Hydrochloride-Loaded Orodispersible Films
Granisetron hydrochloride can be used to prevent and treat nausea and vomiting induced by chemotherapy. Its prolonged half-life and reduced dose requirement improve patient acceptance. However, patients undergoing chemotherapy often suffer from dysphagia and drug spitting due to emesis. Hence, the development of a patient-centered formulation of granisetron hydrochloride with simple medication and high compliance is crucial. The current study employed a polymer combination of polyvinylpyrrolidone/polyvinyl alcohol (PVP/PVA) as film-forming materials and Lycoat® RS 780 as a disintegrant to formulate orodispersible films (ODFs) loaded with granisetron hydrochloride. Guided by the concept of quality by design, the quality target product profile and critical quality attributes (CQAs) for the ODF were defined. Through the quality risk assessment, essential factors that have a significant impact on CQAs were identified. The formulation was screened using the Box–Behnken statistical design with three factors and three levels. Our data suggested that all ODF formulations exhibited a disintegration time of less than 60 seconds and complete dissolution within 5 minutes. Furthermore, the formulation displayed appropriate mechanical properties, water residue, and pH values. Thus, the granisetron hydrochloride-loaded ODF is regarded as a patient-friendly formulation that enhances compliance and consequently aids in therapeutic effectiveness. # These authors contributed equally to this work. Received: 17 March 2023 Accepted: 27 October 2023 Article published online: 01 December 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 December 2023
- Published by Georg Thieme Verlag KG in Pharmaceutical Fronts
- Vol. 05 (04) , e297-e309
Open AccessQuality by Design Approach for Development and Characterization of Granisetron Hydrochloride-Loaded Orodispersible Films
Granisetron hydrochloride can be used to prevent and treat nausea and vomiting induced by chemotherapy. Its prolonged half-life and reduced dose requirement improve patient acceptance. However, patients undergoing chemotherapy often suffer from dysphagia and drug spitting due to emesis. Hence, the development of a patient-centered formulation of granisetron hydrochloride with simple medication and high compliance is crucial. The current study employed a polymer combination of polyvinylpyrrolidone/polyvinyl alcohol (PVP/PVA) as film-forming materials and Lycoat® RS 780 as a disintegrant to formulate orodispersible films (ODFs) loaded with granisetron hydrochloride. Guided by the concept of quality by design, the quality target product profile and critical quality attributes (CQAs) for the ODF were defined. Through the quality risk assessment, essential factors that have a significant impact on CQAs were identified. The formulation was screened using the Box–Behnken statistical design with three factors and three levels. Our data suggested that all ODF formulations exhibited a disintegration time of less than 60 seconds and complete dissolution within 5 minutes. Furthermore, the formulation displayed appropriate mechanical properties, water residue, and pH values. Thus, the granisetron hydrochloride-loaded ODF is regarded as a patient-friendly formulation that enhances compliance and consequently aids in therapeutic effectiveness. # These authors contributed equally to this work. Received: 17 March 2023 Accepted: 27 October 2023 Article published online: 01 December 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 19 June 2020
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (1) , 165-171
Separation and Enrichment of Sudan III Using Surface Modified Hollow Glass Microspheres and Colorimetric Detection
Background: Sudan III has been shown to be carcinogenic to human beings due to the azo chemical structure. A simple, highly selective, and environmentally friendly pretreatment method is usually required before the analysis of Sudan III in complex practical samples due to low concentration and matrix interference. Objective: The aim of this research was to prepare buoyant adsorbents, octyl trimethoxysilane caped hollow glass microspheres (HGMs), and establish a new pretreatment method for the detection of Sudan III in real samples. Method: HGMs were activated and transferred to a flask containing 80 mL ethanol solution (9:1, v/v) and 0.9 mL ammonia. The octyl trimethoxysilane was added to the slurry and covalently coupled on the surface of the HGMs. The modified HGMs were used as adsorbents for the enrichment of Sudan III. After adsorption and desorption, the UV-Vis absorption spectrum was recorded under excitation at 506 nm. Results: Under the optimum conditions, the linear range and detection limit were 0.10–4.0 mg/L and 0.048 mg/L, respectively. The proposed method was successfully employed to detect Sudan III in chili products with acceptable recoveries of spikes (90.7–102%). Conclusions: The adsorbent, which could be separated by flotation, provided a new solid phase extraction method for the pretreatment of complex samples. Highlights: A new solid phase extraction method was provided for the pretreatment of complex samples. In addition, the adsorbents with high enrichment efficiency can be easily separated by flotation and repeatedly used for separation and enrichment of Sudan III.
- 19 June 2020
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (1) , 165-171
Separation and Enrichment of Sudan III Using Surface Modified Hollow Glass Microspheres and Colorimetric Detection
Background: Sudan III has been shown to be carcinogenic to human beings due to the azo chemical structure. A simple, highly selective, and environmentally friendly pretreatment method is usually required before the analysis of Sudan III in complex practical samples due to low concentration and matrix interference. Objective: The aim of this research was to prepare buoyant adsorbents, octyl trimethoxysilane caped hollow glass microspheres (HGMs), and establish a new pretreatment method for the detection of Sudan III in real samples. Method: HGMs were activated and transferred to a flask containing 80 mL ethanol solution (9:1, v/v) and 0.9 mL ammonia. The octyl trimethoxysilane was added to the slurry and covalently coupled on the surface of the HGMs. The modified HGMs were used as adsorbents for the enrichment of Sudan III. After adsorption and desorption, the UV-Vis absorption spectrum was recorded under excitation at 506 nm. Results: Under the optimum conditions, the linear range and detection limit were 0.10–4.0 mg/L and 0.048 mg/L, respectively. The proposed method was successfully employed to detect Sudan III in chili products with acceptable recoveries of spikes (90.7–102%). Conclusions: The adsorbent, which could be separated by flotation, provided a new solid phase extraction method for the pretreatment of complex samples. Highlights: A new solid phase extraction method was provided for the pretreatment of complex samples. In addition, the adsorbents with high enrichment efficiency can be easily separated by flotation and repeatedly used for separation and enrichment of Sudan III.
- Open Access
- 7 February 2020
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 11 (1) , 1-9
Colorimetric determination of amaranth followed enrichment and separation using buoyant adsorbents
A buoyant solid-phase extraction adsorbent was prepared by sodium alginate-coated hollow glass microspheres (HGMs) modified with 3-aminopropyltrimethoxysilane (3-APTS) for the separation and enrichment of anionic dye amaranth. After adsorbing amaranth, these low-density adsorbents can float on the surface of the solution, so the separation between adsorbents and substrates can be carried out by flotation. Quantitative determination of amaranth after separation and enrichment can be achieved by combining spectrophotometry. Under the optimum conditions, the linear range and detection limit for amaranth detection were 0.02 mg L−1–2.0 mg L−1 and 0.0021 mg L−1, respectively. The proposed method was applied to the determination of amaranth in different beverages, and the results were in good agreement with those by high-performance liquid chromatography (HPLC). The recoveries of amaranth in different beverages were between 97.93 and 105.91%. The floating adsorbent can be used as a conventional sample preparation method for the detection of low concentration analytes in complex samples.
- 7 February 2020
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 11 (1) , 1-9
Open AccessColorimetric determination of amaranth followed enrichment and separation using buoyant adsorbents
A buoyant solid-phase extraction adsorbent was prepared by sodium alginate-coated hollow glass microspheres (HGMs) modified with 3-aminopropyltrimethoxysilane (3-APTS) for the separation and enrichment of anionic dye amaranth. After adsorbing amaranth, these low-density adsorbents can float on the surface of the solution, so the separation between adsorbents and substrates can be carried out by flotation. Quantitative determination of amaranth after separation and enrichment can be achieved by combining spectrophotometry. Under the optimum conditions, the linear range and detection limit for amaranth detection were 0.02 mg L−1–2.0 mg L−1 and 0.0021 mg L−1, respectively. The proposed method was applied to the determination of amaranth in different beverages, and the results were in good agreement with those by high-performance liquid chromatography (HPLC). The recoveries of amaranth in different beverages were between 97.93 and 105.91%. The floating adsorbent can be used as a conventional sample preparation method for the detection of low concentration analytes in complex samples.
- 9 September 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 55 (80) , 12040-12043
Photofuel cell coupling with redox cycling as a highly sensitive and selective self-powered sensing platform for the detection of tyrosinase activity
Redox cycling is successfully integrated in a photofuel cell to provide an amplified self-powered sensing signal for the specific detection of tyrosinase activity.
- 9 September 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 55 (80) , 12040-12043
Photofuel cell coupling with redox cycling as a highly sensitive and selective self-powered sensing platform for the detection of tyrosinase activity
Redox cycling is successfully integrated in a photofuel cell to provide an amplified self-powered sensing signal for the specific detection of tyrosinase activity.
- 23 October 2018
- Published by Springer Nature in Microchimica Acta
- Vol. 185 (11) , 514
Determination of DNA based on fluorescence quenching of terbium doped carbon dots
This work describes the preparation of carbon dots doped with terbium(III) (Tb-CDs) via a hydrothermal method, starting from terbium ion and ethylenediamine. The size, composition and spectral properties of the Tb-CDs were characterized by transmission electron microscopy, infrared spectra, and fluorescence spectra. The results show that doping of the CDs with Tb(III) reduces the particle size and results in more uniform particles, while fluorescence (at excitation/emission peaks of 380/475 nm) is strongly enhanced. The interaction between Tb-CDs and ct-DNA results in fluorescence quenching of Tb-CDs. The findings were exploited to design a quenchometric method for the determination of ct-DNA. The signal drops linearly in the 80 ng·mL−1 to 50 μg·mL−1 ct-DNA concentration range, and the detection limit is 53 ng·mL−1. The method was applied to the determination of ct-DNA in spiked samples and gave satisfactory results. The possible fluorescence quenching mechanism (which is mainly static) was investigated using the Stern–Volmer equation and thermodynamic equations.
- 23 October 2018
- Published by Springer Nature in Microchimica Acta
- Vol. 185 (11) , 514
Determination of DNA based on fluorescence quenching of terbium doped carbon dots
This work describes the preparation of carbon dots doped with terbium(III) (Tb-CDs) via a hydrothermal method, starting from terbium ion and ethylenediamine. The size, composition and spectral properties of the Tb-CDs were characterized by transmission electron microscopy, infrared spectra, and fluorescence spectra. The results show that doping of the CDs with Tb(III) reduces the particle size and results in more uniform particles, while fluorescence (at excitation/emission peaks of 380/475 nm) is strongly enhanced. The interaction between Tb-CDs and ct-DNA results in fluorescence quenching of Tb-CDs. The findings were exploited to design a quenchometric method for the determination of ct-DNA. The signal drops linearly in the 80 ng·mL−1 to 50 μg·mL−1 ct-DNA concentration range, and the detection limit is 53 ng·mL−1. The method was applied to the determination of ct-DNA in spiked samples and gave satisfactory results. The possible fluorescence quenching mechanism (which is mainly static) was investigated using the Stern–Volmer equation and thermodynamic equations.
- 17 July 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (18) , 7540-7547
Simple hydrothermal preparation of carbon nanodots and their application in colorimetric and fluorimetric detection of mercury ions
The present article reports on the one-step rapid green synthesis of water-soluble, fluorescent carbon nanodots (C-dots) with a quantum yield of 8.9%. Compared with previous hydrothermal methods, the proposed method is performed at lower temperature and results in larger size (20–30 nm) C-dots. We observed that UV-Vis absorbance at 302 nm of C-dots shows a significant linear correlation with the concentration of Hg2+ added, which indicates that the as-prepared carbon dots could act as a colorimetric probe for Hg2+. The linear range of this colorimetric probe is 1.0 × 10−9–7.0 × 10−7 mol L−1 and the detection limit is 5.7 × 10−10 mol L−1. Simultaneously, the fluorescence of the C-dots in pH 5.0 phosphate buffer solution can be dramatically quenched by Hg2+, whereas it is nearly unaffected by other metal ions. A good linear relationship exists between the quenching efficiency (F0/F) and the concentration of Hg2+ in the range of 7.0 × 10−9–7.0 × 10−7 mol L−1 with a detection limit (3σ) of 5.5 × 10−10 mol L−1. This dual probe for Hg2+ exhibits excellent performance in polluted tap water samples analysis, suggesting its promising application in the future.
- 17 July 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (18) , 7540-7547
Simple hydrothermal preparation of carbon nanodots and their application in colorimetric and fluorimetric detection of mercury ions
The present article reports on the one-step rapid green synthesis of water-soluble, fluorescent carbon nanodots (C-dots) with a quantum yield of 8.9%. Compared with previous hydrothermal methods, the proposed method is performed at lower temperature and results in larger size (20–30 nm) C-dots. We observed that UV-Vis absorbance at 302 nm of C-dots shows a significant linear correlation with the concentration of Hg2+ added, which indicates that the as-prepared carbon dots could act as a colorimetric probe for Hg2+. The linear range of this colorimetric probe is 1.0 × 10−9–7.0 × 10−7 mol L−1 and the detection limit is 5.7 × 10−10 mol L−1. Simultaneously, the fluorescence of the C-dots in pH 5.0 phosphate buffer solution can be dramatically quenched by Hg2+, whereas it is nearly unaffected by other metal ions. A good linear relationship exists between the quenching efficiency (F0/F) and the concentration of Hg2+ in the range of 7.0 × 10−9–7.0 × 10−7 mol L−1 with a detection limit (3σ) of 5.5 × 10−10 mol L−1. This dual probe for Hg2+ exhibits excellent performance in polluted tap water samples analysis, suggesting its promising application in the future.
- 1 September 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (22) , 9015-9021
Reversible multi-control fluorescent switch and molecular logic gate based on selective recognition of Fe3+ and its application to multiplex detection
Schematic diagram describing the working process of molecular logic gates (a) “NOR”, (b) “OR”, and (c) “INHIBIT”, and (d) the possible binding modes between PA and Fe3+.
- 1 September 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (22) , 9015-9021
Reversible multi-control fluorescent switch and molecular logic gate based on selective recognition of Fe3+ and its application to multiplex detection
Schematic diagram describing the working process of molecular logic gates (a) “NOR”, (b) “OR”, and (c) “INHIBIT”, and (d) the possible binding modes between PA and Fe3+.
- 7 January 2013
- Published by Wiley in Luminescence
- Vol. 28 (6) , 894-899
Sensitive determination of DNA based on the interaction between prulifloxacin–terbium(III) complex and DNA
A simple spectrofluorimetric method is described for the determination of DNA, based on its enhancement of the fluorescence intensity of prulifloxacin (PUFX)–Tb3+. The luminescence intensity of the PUFX–Tb3+ complex increased up to 10‐fold after adding DNA. The excitation and emission wavelengths were 345 and 545 nm, respectively. Under optimum conditions, variations in the fluorescence intensity showed a good linear relationship with the concentration of hsDNA in the range of 3.0 × 10‐9 to 1.0 × 10‐6 g/mL, with a correlation coefficient (R) of 0.997, and the detection limit was 2.1 × 10‐9 g/mL. The method was successfully applied to the determination of DNA in synthetic samples, and recoveries were in the range 97.3–102.0%. The mechanism of fluorescence enhancement of the PUFX–Tb3+ complex by DNA is also discussed. The mechanism may involve formation of a ternary complex mainly by intercalation binding together with weak electrostatic interaction, which will increase the energy transition from ligand to Tb3+, increasing the rigidity of the complex, and decreasing the radiationless energy loss through O–H vibration of the H2O molecule in the PUFX–Tb3+ compl+osed method is not only more robust and friendly to the environment, but also of relatively higher sensitivity. Copyright © 2013 John Wiley & Sons, Ltd.
- 7 January 2013
- Published by Wiley in Luminescence
- Vol. 28 (6) , 894-899
Sensitive determination of DNA based on the interaction between prulifloxacin–terbium(III) complex and DNA
A simple spectrofluorimetric method is described for the determination of DNA, based on its enhancement of the fluorescence intensity of prulifloxacin (PUFX)–Tb3+. The luminescence intensity of the PUFX–Tb3+ complex increased up to 10‐fold after adding DNA. The excitation and emission wavelengths were 345 and 545 nm, respectively. Under optimum conditions, variations in the fluorescence intensity showed a good linear relationship with the concentration of hsDNA in the range of 3.0 × 10‐9 to 1.0 × 10‐6 g/mL, with a correlation coefficient (R) of 0.997, and the detection limit was 2.1 × 10‐9 g/mL. The method was successfully applied to the determination of DNA in synthetic samples, and recoveries were in the range 97.3–102.0%. The mechanism of fluorescence enhancement of the PUFX–Tb3+ complex by DNA is also discussed. The mechanism may involve formation of a ternary complex mainly by intercalation binding together with weak electrostatic interaction, which will increase the energy transition from ligand to Tb3+, increasing the rigidity of the complex, and decreasing the radiationless energy loss through O–H vibration of the H2O molecule in the PUFX–Tb3+ compl+osed method is not only more robust and friendly to the environment, but also of relatively higher sensitivity. Copyright © 2013 John Wiley & Sons, Ltd.