Jay Alan Montgomery
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jay Alan Montgomery has a total of 160 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Randall Ellis
Vanderbilt Heart Institute, Nashville, Tennessee, USA
7 shared publications - George H. Crossley
Vanderbilt University Medical Center
7 shared publications Christopher R. Ellis
Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
6 shared publicationsGeorge H. Crossley
Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
6 shared publications- Travis D. Richardson
Department of Cardiac Electrophysiology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
6 shared publications William G. Stevenson
Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
6 shared publications
Latest Publications
- 3 November 2025
- Published by Elsevier in Cardiology Clinics
- Vol. 43 (4) , 547-556
How to Approach Patients with Cardiac Implantable Electronic Devices and Bacteremia
- 3 November 2025
- Published by Elsevier in Cardiology Clinics
- Vol. 43 (4) , 547-556
How to Approach Patients with Cardiac Implantable Electronic Devices and Bacteremia
- 1 August 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (8) , e013378
2-Hydroxybenzylamine for Treatment of Atrial Fibrillation: A First-in-Human Clinical Pilot Trial
BACKGROUND: Inflammation is a common mechanism for atrial fibrillation (AF). 2-Hydroxybenzylamine (2-HOBA) is a novel therapeutic that scavenges isolevuglandins—a downstream mediator of inflammation and oxidative stress. 2-HOBA is safe and reduces AF in mice, prompting a first-in-human pilot clinical trial. METHODS: Participants were enrolled and randomized 1:1 to placebo or 2-HOBA (750 mg p.o. TID) 3 days before a planned AF ablation. Participants were monitored for 28 days after their ablation for recurrence of AF as detected by smartwatch single-lead ECG recordings. Blood was collected at the time of ablation for measurement of isolevuglandin levels. The study drug was stopped at 28 days. A 12-month extended follow-up period was used to monitor for any residual effect of the study drug on AF recurrence. RESULTS: 2-HOBA increased the risk of AF recurrence in the postablation population (odds ratio, 3.65 [95% CI, 1.31–10.16]; P =0.013) after prespecified adjustment for potential confounders. This increased risk of recurrence remained despite post hoc adjustment for other clinical risk factors. There was no difference in isolevuglandin levels between the 2-HOBA and placebo groups. After the study drug was stopped, there was no difference in AF recurrence between the 2-HOBA and placebo groups during the 12-month extended follow-up. CONCLUSIONS: 2-HOBA was associated with a higher risk of AF recurrence when tested early after AF ablation. This result was unexpected based on preclinical data, but paradoxical associations with AF have been previously reported for other drugs that target inflammation and oxidative stress pathways, such as omega-3 fatty acids. The mechanisms for AF immediately following ablation may be different from AF that occurs under other conditions, and the generalizability of these results to all forms of AF remains unknown.
- 1 August 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (8) , e013378
2-Hydroxybenzylamine for Treatment of Atrial Fibrillation: A First-in-Human Clinical Pilot Trial
BACKGROUND: Inflammation is a common mechanism for atrial fibrillation (AF). 2-Hydroxybenzylamine (2-HOBA) is a novel therapeutic that scavenges isolevuglandins—a downstream mediator of inflammation and oxidative stress. 2-HOBA is safe and reduces AF in mice, prompting a first-in-human pilot clinical trial. METHODS: Participants were enrolled and randomized 1:1 to placebo or 2-HOBA (750 mg p.o. TID) 3 days before a planned AF ablation. Participants were monitored for 28 days after their ablation for recurrence of AF as detected by smartwatch single-lead ECG recordings. Blood was collected at the time of ablation for measurement of isolevuglandin levels. The study drug was stopped at 28 days. A 12-month extended follow-up period was used to monitor for any residual effect of the study drug on AF recurrence. RESULTS: 2-HOBA increased the risk of AF recurrence in the postablation population (odds ratio, 3.65 [95% CI, 1.31–10.16]; P =0.013) after prespecified adjustment for potential confounders. This increased risk of recurrence remained despite post hoc adjustment for other clinical risk factors. There was no difference in isolevuglandin levels between the 2-HOBA and placebo groups. After the study drug was stopped, there was no difference in AF recurrence between the 2-HOBA and placebo groups during the 12-month extended follow-up. CONCLUSIONS: 2-HOBA was associated with a higher risk of AF recurrence when tested early after AF ablation. This result was unexpected based on preclinical data, but paradoxical associations with AF have been previously reported for other drugs that target inflammation and oxidative stress pathways, such as omega-3 fatty acids. The mechanisms for AF immediately following ablation may be different from AF that occurs under other conditions, and the generalizability of these results to all forms of AF remains unknown.
- Open Access
- 15 July 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (9) , 1911-1922
Clinical Outcomes of Concurrent Ventricular Electrical Storm and Infection
- 15 July 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (9) , 1911-1922
Open AccessClinical Outcomes of Concurrent Ventricular Electrical Storm and Infection
- 19 November 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (1) , 198-200
Risk Prediction in Non‐Ischemic Cardiomyoapthy
- 19 November 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (1) , 198-200
Risk Prediction in Non‐Ischemic Cardiomyoapthy
- 20 September 2024
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 16 (4) , 373-382
How to Approach Patients with Cardiac Implantable Electronic Devices and Bacteremia
- 20 September 2024
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 16 (4) , 373-382
How to Approach Patients with Cardiac Implantable Electronic Devices and Bacteremia
- 1 June 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (6) , e012635
Can Intracardiac Echocardiography Reduce Steam Pops During Half-Normal Saline Irrigated Radiofrequency Ablation?
BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% ( P P =0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P =0.004, and odds ratio, 29.93; P <0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.
- 1 June 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (6) , e012635
Can Intracardiac Echocardiography Reduce Steam Pops During Half-Normal Saline Irrigated Radiofrequency Ablation?
BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% ( P P =0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P =0.004, and odds ratio, 29.93; P <0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.
- Open Access
- 19 March 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (6) , e031029
Recurrence After Atrial Fibrillation Ablation and Investigational Biomarkers of Cardiac Remodeling
Background: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. Methods and Results: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein‐10, angiopoietin‐2, fibroblast growth factor‐23, insulin‐like growth factor‐binding protein‐7, myosin‐binding protein C3, growth differentiation factor‐15, interleukin‐6, N‐terminal pro‐brain natriuretic peptide, and high‐sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [2 ], LA diameter ≥43 mm, EF P =0.007) and interleukin‐6 (odds ratio, 1.02 [95% CI, 1.003–1.03]; P =0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. Conclusions: Higher angiopoietin‐2 and interleukin‐6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.
- 19 March 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (6) , e031029
Open AccessRecurrence After Atrial Fibrillation Ablation and Investigational Biomarkers of Cardiac Remodeling
Background: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. Methods and Results: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein‐10, angiopoietin‐2, fibroblast growth factor‐23, insulin‐like growth factor‐binding protein‐7, myosin‐binding protein C3, growth differentiation factor‐15, interleukin‐6, N‐terminal pro‐brain natriuretic peptide, and high‐sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [2 ], LA diameter ≥43 mm, EF P =0.007) and interleukin‐6 (odds ratio, 1.02 [95% CI, 1.003–1.03]; P =0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. Conclusions: Higher angiopoietin‐2 and interleukin‐6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.
- Open Access
- 1 February 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (2)
Safety of ventricular arrhythmia radiofrequency ablation with half-normal saline irrigation
Aims: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. Methods and results: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15 Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. Conclusion: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.
- 1 February 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (2)
Open AccessSafety of ventricular arrhythmia radiofrequency ablation with half-normal saline irrigation
Aims: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. Methods and results: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15 Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. Conclusion: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.
- 21 April 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (8) , 782-788
Clinical Outcomes in Patients With Bacteremia and Concomitant Left Ventricular Assist Devices and Cardiac Implantable Electronic Devices
Infection remains a common cause of morbidity and mortality in patients with both left ventricular assist devices (LVADs) and cardiac implanted electronic devices (CIEDs) with limited data describing outcomes in patients who have both devices implanted. We performed a single-center, retrospective, observational cohort study of patients with both a transvenous CIED and LVAD who developed bacteremia. Ninety-one patients were evaluated. Eighty-one patients (89.0%) were treated medically and nine patients (9.9%) underwent surgical management. A multivariable logistic regression showed that blood culture positivity for >72 hours was associated with inpatient death, when controlled for age and management strategy (odds ratio [OR] = 3.73 [95% confidence interval {CI} = 1.34–10.4], p = 0.012). In patients who survived the initial hospitalization, the use of long-term suppressive antibiotics was not associated with the composite outcome of death or infection recurrence within 1 year, when controlled for age and management strategy (OR = 2.31 [95% CI = 0.88–2.62], p = 0.09). A Cox proportional hazards model showed that blood culture positivity for >72 hours was associated with a trend toward increased mortality in the first year, when controlled for age, management strategy, and staphylococcal infection (hazard ratio = 1.72 [95% CI = 0.88–3.37], p = 0.11). Surgical management was associated with a trend toward decreased mortality (hazard ratio = 0.23 [95% CI = 0.05–1.00], p = 0.05).
- 21 April 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 69 (8) , 782-788
Clinical Outcomes in Patients With Bacteremia and Concomitant Left Ventricular Assist Devices and Cardiac Implantable Electronic Devices
Infection remains a common cause of morbidity and mortality in patients with both left ventricular assist devices (LVADs) and cardiac implanted electronic devices (CIEDs) with limited data describing outcomes in patients who have both devices implanted. We performed a single-center, retrospective, observational cohort study of patients with both a transvenous CIED and LVAD who developed bacteremia. Ninety-one patients were evaluated. Eighty-one patients (89.0%) were treated medically and nine patients (9.9%) underwent surgical management. A multivariable logistic regression showed that blood culture positivity for >72 hours was associated with inpatient death, when controlled for age and management strategy (odds ratio [OR] = 3.73 [95% confidence interval {CI} = 1.34–10.4], p = 0.012). In patients who survived the initial hospitalization, the use of long-term suppressive antibiotics was not associated with the composite outcome of death or infection recurrence within 1 year, when controlled for age and management strategy (OR = 2.31 [95% CI = 0.88–2.62], p = 0.09). A Cox proportional hazards model showed that blood culture positivity for >72 hours was associated with a trend toward increased mortality in the first year, when controlled for age, management strategy, and staphylococcal infection (hazard ratio = 1.72 [95% CI = 0.88–3.37], p = 0.11). Surgical management was associated with a trend toward decreased mortality (hazard ratio = 0.23 [95% CI = 0.05–1.00], p = 0.05).
- 1 October 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (10) , e010713
A Mechanistic Clinical Trial Using ( R )- Versus (S )-Propafenone to Test RyR2 (Ryanodine Receptor) Inhibition for the Prevention of Atrial Fibrillation Induction
Background: Experimental data suggest ryanodine receptor-mediated intracellular calcium leak is a mechanism for atrial fibrillation (AF), but evidence in humans is still needed. Propafenone is composed of two enantiomers that are equally potent sodium-channel blockers; however, (R )-propafenone is an ryanodine receptor inhibitor whereas (S )-propafenone is not. This study tested the hypothesis that ryanodine receptor inhibition with (R )-propafenone prevents induction of AF compared to (S )-propafenone or placebo in patients referred for AF ablation. Methods: Participants were randomized 4:4:1 to a one-time intravenous dose of (R )-propafenone, (S )-propafenone, or placebo. The study drug was given at the start of the procedure and an AF induction protocol using rapid atrial pacing was performed before ablation. The primary endpoint was 30 s of AF or atrial flutter. Results: A total of 193 participants were enrolled and 165 (85%) completed the study protocol (median age: 63 years, 58% male, 95% paroxysmal AF). Sustained AF and/or atrial flutter was induced in 60 participants (84.5%) receiving (R )-propafenone, 60 (80.0%) receiving (S )-propafenone group, and 12 (63.2%) receiving placebo. Atrial flutter occurred significantly more often in the (R )-propafenone (N=23, 32.4%) and (S )-propafenone (N=26, 34.7%) groups compared to placebo (N=1, 5.3%, P =0.029). There was no significant difference between (R )-propafenone and (S )-propafenone for the primary outcome of AF and/or atrial flutter induction in univariable ( P =0.522) or multivariable analysis ( P =0.199, adjusted for age and serum drug level). Conclusions: There is no difference in AF inducibility between (R )-propafenone and (S )-propafenone at clinically relevant concentrations. These results are confounded by a high rate of inducible atrial flutter due to sodium-channel blockade. Registration: https://clinicaltrials.gov ; Unique Identifier: NCT02710669.
- 1 October 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (10) , e010713
A Mechanistic Clinical Trial Using ( R )- Versus (S )-Propafenone to Test RyR2 (Ryanodine Receptor) Inhibition for the Prevention of Atrial Fibrillation Induction
Background: Experimental data suggest ryanodine receptor-mediated intracellular calcium leak is a mechanism for atrial fibrillation (AF), but evidence in humans is still needed. Propafenone is composed of two enantiomers that are equally potent sodium-channel blockers; however, (R )-propafenone is an ryanodine receptor inhibitor whereas (S )-propafenone is not. This study tested the hypothesis that ryanodine receptor inhibition with (R )-propafenone prevents induction of AF compared to (S )-propafenone or placebo in patients referred for AF ablation. Methods: Participants were randomized 4:4:1 to a one-time intravenous dose of (R )-propafenone, (S )-propafenone, or placebo. The study drug was given at the start of the procedure and an AF induction protocol using rapid atrial pacing was performed before ablation. The primary endpoint was 30 s of AF or atrial flutter. Results: A total of 193 participants were enrolled and 165 (85%) completed the study protocol (median age: 63 years, 58% male, 95% paroxysmal AF). Sustained AF and/or atrial flutter was induced in 60 participants (84.5%) receiving (R )-propafenone, 60 (80.0%) receiving (S )-propafenone group, and 12 (63.2%) receiving placebo. Atrial flutter occurred significantly more often in the (R )-propafenone (N=23, 32.4%) and (S )-propafenone (N=26, 34.7%) groups compared to placebo (N=1, 5.3%, P =0.029). There was no significant difference between (R )-propafenone and (S )-propafenone for the primary outcome of AF and/or atrial flutter induction in univariable ( P =0.522) or multivariable analysis ( P =0.199, adjusted for age and serum drug level). Conclusions: There is no difference in AF inducibility between (R )-propafenone and (S )-propafenone at clinically relevant concentrations. These results are confounded by a high rate of inducible atrial flutter due to sodium-channel blockade. Registration: https://clinicaltrials.gov ; Unique Identifier: NCT02710669.