Da-Jeng Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Da-Jeng Yao has a total of 258 co-authors. Here are the top co-authors by number of shared publications:
Hong-Yuan Huang
Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Taoyuan, Taiwan, R.O.C
9 shared publications- Hong-Yuan Huang
Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Linkou Medical Center, 5, Fu-Shin Street, Taoyuan 33301, Taiwan
8 shared publications - Cheng-Hsien Liu
National Tsing Hua University
6 shared publications Yi-Ju Liu
Food Industry Research and Development Institute, Hsinchu 300193, Taiwan, ROC
6 shared publications- Shih-Kang Fan
Kansas State University
5 shared publications - Wensyang Hsu
Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
5 shared publications
Latest Publications
- Open Access
- 24 July 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (15) , 6592
Microfluidic Fibroblast Cell Culture Chip for Embryo Co-Culture: Analysis of Preimplantation Embryo Viability and Development Potential
Preimplantation embryo development requires a tightly regulated microenvironment that is not fully reproduced by conventional static culture. We developed a polydimethylsiloxane-based microfluidic embryo co-culture platform integrating compartmentalized architecture with dynamic perfusion to simulate physiological conditions. The study included two stages. First, NIH/3T3 mouse fibroblasts were evaluated as helper cells under three culture conditions after transition to embryo culture medium. Helper-cell viability in the dynamic chip was 84.72%, compared with 71.91% after manual medium replacement in 24-well plates and 94.27% in the 24-well control group. Second, mouse embryos were cultured under four conditions: conventional 24-well plates, static microfluidic chip culture with co-culture, dynamic microfluidic chips without co-culture, and dynamic microfluidic chip co-culture. Blastocyst formation rates were 100.0% (9/9), 0.0% (0/6), 33.3% (3/9), and 55.5% (5/9), respectively. Because no inferential statistical analysis was performed, these proportions are interpreted descriptively. Nevertheless, the blastocyst formation in the microfluidic co-culture group supports the technical feasibility of integrating dynamic perfusion and helper-cell co-culture within a single platform. Further optimization and validation are required. This platform provides a foundation for future development of advanced embryo culture technologies including patient-specific endometrial co-culture systems in assisted reproduction, disease modeling, or drug development.
- 24 July 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (15) , 6592
Open AccessMicrofluidic Fibroblast Cell Culture Chip for Embryo Co-Culture: Analysis of Preimplantation Embryo Viability and Development Potential
Preimplantation embryo development requires a tightly regulated microenvironment that is not fully reproduced by conventional static culture. We developed a polydimethylsiloxane-based microfluidic embryo co-culture platform integrating compartmentalized architecture with dynamic perfusion to simulate physiological conditions. The study included two stages. First, NIH/3T3 mouse fibroblasts were evaluated as helper cells under three culture conditions after transition to embryo culture medium. Helper-cell viability in the dynamic chip was 84.72%, compared with 71.91% after manual medium replacement in 24-well plates and 94.27% in the 24-well control group. Second, mouse embryos were cultured under four conditions: conventional 24-well plates, static microfluidic chip culture with co-culture, dynamic microfluidic chips without co-culture, and dynamic microfluidic chip co-culture. Blastocyst formation rates were 100.0% (9/9), 0.0% (0/6), 33.3% (3/9), and 55.5% (5/9), respectively. Because no inferential statistical analysis was performed, these proportions are interpreted descriptively. Nevertheless, the blastocyst formation in the microfluidic co-culture group supports the technical feasibility of integrating dynamic perfusion and helper-cell co-culture within a single platform. Further optimization and validation are required. This platform provides a foundation for future development of advanced embryo culture technologies including patient-specific endometrial co-culture systems in assisted reproduction, disease modeling, or drug development.
- Open Access
- 10 July 2026
- Published by Elsevier in SSRN Electronic Journal
Revealing the Global Optimum of Thermal Resistance in Graphene Nanofluids Pulsating Heat Pipes via Complex System Response platform
The rapid increase in computational power of next-generation artificial intelligence (AI) processors has driven thermal management requirements beyond the capability of conventional cooling technologies. Graphene nanofluids in pulsating heat pipes (PHPs) offer a promising approach by enhancing nucleation, promoting two-phase oscillatory flow, and delaying dry-out. However, optimization remains challenging due to strongly coupled nonlinear interactions, where excessive nanoparticle concentration or mismatched operating conditions can degrade thermal performance.,Here, we apply the Complex System Response (CSR) platform to efficiently identify optimal operating conditions within this high-dimensional parameter space. Using only 19 experimental datasets, CSR enables deterministic response surface analysis and identification of the optimal thermal resistance condition. Experimental results demonstrate that, at an optimal graphene concentration of 0.15 wt.%, the effective thermal conductivity of the PHPs is enhanced by more than one order of magnitude compared with pure water under the investigated operating conditions.,These results demonstrate that CSR provides a rapid and data-efficient approach for analyzing and optimizing complex thermal systems, offering a scalable solution for advanced AI thermal management applications.
- 10 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRevealing the Global Optimum of Thermal Resistance in Graphene Nanofluids Pulsating Heat Pipes via Complex System Response platform
The rapid increase in computational power of next-generation artificial intelligence (AI) processors has driven thermal management requirements beyond the capability of conventional cooling technologies. Graphene nanofluids in pulsating heat pipes (PHPs) offer a promising approach by enhancing nucleation, promoting two-phase oscillatory flow, and delaying dry-out. However, optimization remains challenging due to strongly coupled nonlinear interactions, where excessive nanoparticle concentration or mismatched operating conditions can degrade thermal performance.,Here, we apply the Complex System Response (CSR) platform to efficiently identify optimal operating conditions within this high-dimensional parameter space. Using only 19 experimental datasets, CSR enables deterministic response surface analysis and identification of the optimal thermal resistance condition. Experimental results demonstrate that, at an optimal graphene concentration of 0.15 wt.%, the effective thermal conductivity of the PHPs is enhanced by more than one order of magnitude compared with pure water under the investigated operating conditions.,These results demonstrate that CSR provides a rapid and data-efficient approach for analyzing and optimizing complex thermal systems, offering a scalable solution for advanced AI thermal management applications.
- Open Access
- 1 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 201
A Microfluidic Platform for Viscosity Testing of Non-Newtonian Fluids in Engineering and Biomedical Applications
This study presents a microfluidic platform for non-Newtonian fluid viscosity sensing, integrating a high-flow-rate flow field stabilizer to mitigate flow uniformity limitations under elevated flow rate conditions. Building upon an established dual-phase laminar flow principle that determines relative viscosity via channel occupancy, this research aimed to extend the measurable viscosity range from 1–10 cP to 1–50 cP, which covers viscosity regimes relevant to biomedical fluids, dairy products during gelation, and low-to-moderate viscosity industrial liquids. A flow stabilizer was developed through computational fluid dynamics simulations, optimizing three key design parameters: blocker position, porosity, and the number of outlet paths. The N5 design proved most effective, providing over 50% reduction in standard deviation for asymmetric velocity distribution in high-flow simulations. The system was validated using simulated blood and dairy samples, achieving over 95% viscosity accuracy with less than 5% sample volume error compared to conventional viscometers. The chip successfully captured viscosity transitions during milk acidification and gelation, demonstrating excellent agreement with standard measurements. This low-volume, high-precision platform offers promising potential for applications in food engineering, biomedical diagnostics, and industrial fluid monitoring, enhancing microfluidic rheometry capabilities.
- 1 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 201
Open AccessA Microfluidic Platform for Viscosity Testing of Non-Newtonian Fluids in Engineering and Biomedical Applications
This study presents a microfluidic platform for non-Newtonian fluid viscosity sensing, integrating a high-flow-rate flow field stabilizer to mitigate flow uniformity limitations under elevated flow rate conditions. Building upon an established dual-phase laminar flow principle that determines relative viscosity via channel occupancy, this research aimed to extend the measurable viscosity range from 1–10 cP to 1–50 cP, which covers viscosity regimes relevant to biomedical fluids, dairy products during gelation, and low-to-moderate viscosity industrial liquids. A flow stabilizer was developed through computational fluid dynamics simulations, optimizing three key design parameters: blocker position, porosity, and the number of outlet paths. The N5 design proved most effective, providing over 50% reduction in standard deviation for asymmetric velocity distribution in high-flow simulations. The system was validated using simulated blood and dairy samples, achieving over 95% viscosity accuracy with less than 5% sample volume error compared to conventional viscometers. The chip successfully captured viscosity transitions during milk acidification and gelation, demonstrating excellent agreement with standard measurements. This low-volume, high-precision platform offers promising potential for applications in food engineering, biomedical diagnostics, and industrial fluid monitoring, enhancing microfluidic rheometry capabilities.
- Open Access
- 27 January 2026
- Published by American Chemical Society (ACS) in Crystal Growth & Design
- Vol. 26 (4) , 1635-1648
Equ-Axed Fine-Grained and Nanotwinned Cu with Ultrahigh Tensile Strength
- 27 January 2026
- Published by American Chemical Society (ACS) in Crystal Growth & Design
- Vol. 26 (4) , 1635-1648
Open AccessEqu-Axed Fine-Grained and Nanotwinned Cu with Ultrahigh Tensile Strength
- Open Access
- 2 July 2025
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 192
Mixing in axially rotating co-laminar flows
- 2 July 2025
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 192
Open AccessMixing in axially rotating co-laminar flows
- 28 May 2025
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 941
Optimization of tensile strength of nanotwinned Cu-Ni foils via complex system response methodology
- 28 May 2025
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 941
Optimization of tensile strength of nanotwinned Cu-Ni foils via complex system response methodology
- Open Access
A Long-Range, High-Efficiency Resonant Wireless Power Transfer via Imaginary Turn Ratio Air Voltage Transformer
This paper presents a resonant wireless power transfer method that leverages a 90-degree voltage phase shift between the transmitting and receiving coils to enhance efficiency and maximize power transfer. When the resonant coupling is achieved, the secondary coil with an adjustable capacitor forms a tuned LC circuit. If the primary coil is driven at the resonant frequency of both the primary and secondary sides, the system can transmit 250W of power between the coils over a distance of 50 cm. Using a single power transmitting unit (PTU) board with multiple paralleled gallium nitride high-electron-mobility transistors (GaN HEMTs), the system achieves a maximum power transfer efficiency of 88%, highlighting the effectiveness of the design in high-efficiency, long-distance wireless power transmission. The key to the success of high-power, high-efficiency RWPT is in exhibiting the imaginary turn ratio presented on the air transformer. The imaginary turn ratio can realize the negative impedance conversion that converts the positive resistance on the power-receiving unit into a negative one, and thus, the damping of the resonance oscillation becomes negative and positively encourages more power to be delivered to the power-receiving unit (PRU) load. This paper derives the theory of the imaginary turn ratio and demonstrates the implementation of the RWPT system that exhibits the imaginary turn ratio effect.
Open AccessA Long-Range, High-Efficiency Resonant Wireless Power Transfer via Imaginary Turn Ratio Air Voltage Transformer
This paper presents a resonant wireless power transfer method that leverages a 90-degree voltage phase shift between the transmitting and receiving coils to enhance efficiency and maximize power transfer. When the resonant coupling is achieved, the secondary coil with an adjustable capacitor forms a tuned LC circuit. If the primary coil is driven at the resonant frequency of both the primary and secondary sides, the system can transmit 250W of power between the coils over a distance of 50 cm. Using a single power transmitting unit (PTU) board with multiple paralleled gallium nitride high-electron-mobility transistors (GaN HEMTs), the system achieves a maximum power transfer efficiency of 88%, highlighting the effectiveness of the design in high-efficiency, long-distance wireless power transmission. The key to the success of high-power, high-efficiency RWPT is in exhibiting the imaginary turn ratio presented on the air transformer. The imaginary turn ratio can realize the negative impedance conversion that converts the positive resistance on the power-receiving unit into a negative one, and thus, the damping of the resonance oscillation becomes negative and positively encourages more power to be delivered to the power-receiving unit (PRU) load. This paper derives the theory of the imaginary turn ratio and demonstrates the implementation of the RWPT system that exhibits the imaginary turn ratio effect.
- Open Access
- 21 February 2025
- Published by Elsevier in New Biotechnology
- Vol. 87, 20-28
Microfluidic method for rapidly determining the protein and lipid yield of microalgae
- 21 February 2025
- Published by Elsevier in New Biotechnology
- Vol. 87, 20-28
Open AccessMicrofluidic method for rapidly determining the protein and lipid yield of microalgae
- Open Access
- 20 December 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (12) , 1298
Development of a Microfluidic Viscometer for Non-Newtonian Blood Analog Fluid Analysis
The incidence of stroke is on the rise globally. This affects one in every four individuals each year, underscoring the urgent need for early warning and prevention systems. The existing research highlights the significance of monitoring blood viscosity in stroke risk evaluations. However, the current methods lack the precision to measure viscosity under low shear rate conditions (<100 s⁻¹), which are observed during pulsatility flow. This study addresses this gap by introducing a novel microfluidic platform designed to measure blood viscosity with high precision under pulsatility flow conditions. The systolic blood viscosity (SBV) and diastolic blood viscosity (DBV) can be differentiated and evaluated by using this system. The non-Newtonian behavior of blood is captured across specific shear rate conditions. The platform employs a meticulously designed microarray to simulate the variations in blood viscosity during pulsation within blood vessels.The results demonstrate an impressive accuracy of 95% and excellent reproducibility when compared to traditional viscometers and rheometers and are within the human blood viscosity range of 1–10 cP. This monitoring system holds promise as a valuable addition to stroke risk evaluation methods, with the potential to enhance prediction accuracy.
- 20 December 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (12) , 1298
Open AccessDevelopment of a Microfluidic Viscometer for Non-Newtonian Blood Analog Fluid Analysis
The incidence of stroke is on the rise globally. This affects one in every four individuals each year, underscoring the urgent need for early warning and prevention systems. The existing research highlights the significance of monitoring blood viscosity in stroke risk evaluations. However, the current methods lack the precision to measure viscosity under low shear rate conditions (<100 s⁻¹), which are observed during pulsatility flow. This study addresses this gap by introducing a novel microfluidic platform designed to measure blood viscosity with high precision under pulsatility flow conditions. The systolic blood viscosity (SBV) and diastolic blood viscosity (DBV) can be differentiated and evaluated by using this system. The non-Newtonian behavior of blood is captured across specific shear rate conditions. The platform employs a meticulously designed microarray to simulate the variations in blood viscosity during pulsation within blood vessels.The results demonstrate an impressive accuracy of 95% and excellent reproducibility when compared to traditional viscometers and rheometers and are within the human blood viscosity range of 1–10 cP. This monitoring system holds promise as a valuable addition to stroke risk evaluation methods, with the potential to enhance prediction accuracy.
- Open Access
- 10 September 2024
- Published by Elsevier in The Journal of Liquid Biopsy
- Vol. 6, 100167
Development and validation of a novel combinational index of liquid biopsy biomarker for longitudinal lung cancer patient management
- 10 September 2024
- Published by Elsevier in The Journal of Liquid Biopsy
- Vol. 6, 100167
Open AccessDevelopment and validation of a novel combinational index of liquid biopsy biomarker for longitudinal lung cancer patient management