Aiping Fan
Research Subjects
Aiping Fan has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Shanshan Li
School of Pharmaceutical Science and Technology, Faculty of Medicine
6 shared publicationsFeiqian Wang
School of Pharmaceutical Science and Technology, Faculty of Medicine, Tianjin University, Tianjin 300072, China
5 shared publicationsYongxin Huang
School of Pharmaceutical Science and Technology Tianjin University Tianjin China
5 shared publicationsNingning Yue
School of Pharmaceutical Science and Technology, Tianjin University, Tianjin, People’s Republic of China
4 shared publicationsRushi Liang
School of Pharmaceutical Science and Technology, Tianjin University, Tianjin300072, PR China
4 shared publicationsRuyuan Wang
School of Pharmaceutical Science and Technology, Tianjin University, Tianjin, People’s Republic of China
4 shared publications
Latest Publications
- 23 October 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (44) , 21551-21561
Hierarchical CoZn-MOF-Supported Ag Nanocatalyst for Chemiluminescence Assay
- 23 October 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (44) , 21551-21561
Hierarchical CoZn-MOF-Supported Ag Nanocatalyst for Chemiluminescence Assay
- 16 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (25) , 13619-13627
Preparation and Applications of a Chemiluminescent Film Deposited on a Well Plate: Focusing on 96-Well Technology
In this study, polydopamine (PDA) was employed for the first time as a coupling intermediate for the immobilization of a chemiluminescent (CL) film containing both the catalyst (zeolitic imidazolate framework-67, ZIF-67) and CL substance (N-(4-aminobutyl)-N-ethylisoluminol, ABEI) in the wells of a 96-well plate. The prepared CL film showed good responses to H2O2, with a limit of detection (LOD) of 1.2 nM, as well as to acetylcholinesterase (AChE) by employing a cascade enzymatic reaction, and it could be applied for the screening of AChE inhibitors. More interestingly, a decreased CL signal was observed when the CL film was incubated with gentamicin (GEN), which is a kind of aminoglycoside (AG). Mechanism studies indicated that the CL responses of the CL film to GEN should be attributed to the competitive binding of GEN with cobalt ions in the CL film, resulting in the loss of catalytic centers in the ABEI-H2O2 CL reaction and a subsequent decrease of CL signals. The CL film exhibited good sensitivity for the detection of AGs such as GEN, neomycin (NEO), streptomycin (STR), kanamycin (KAN), and amikacin (AMI), with LODs of 2.4 nM, 7.8 nM, 2.4 nM, 9.6 nM, and 3.0 nM, respectively. The proposed heterogeneous sensing platform could be employed for the detection of AGs in different dosage forms and complex matrices such as natural water, serum, and milk, possessing advantages including high sensitivity, good specificity, and high efficiency.
- 16 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (25) , 13619-13627
Preparation and Applications of a Chemiluminescent Film Deposited on a Well Plate: Focusing on 96-Well Technology
In this study, polydopamine (PDA) was employed for the first time as a coupling intermediate for the immobilization of a chemiluminescent (CL) film containing both the catalyst (zeolitic imidazolate framework-67, ZIF-67) and CL substance (N-(4-aminobutyl)-N-ethylisoluminol, ABEI) in the wells of a 96-well plate. The prepared CL film showed good responses to H2O2, with a limit of detection (LOD) of 1.2 nM, as well as to acetylcholinesterase (AChE) by employing a cascade enzymatic reaction, and it could be applied for the screening of AChE inhibitors. More interestingly, a decreased CL signal was observed when the CL film was incubated with gentamicin (GEN), which is a kind of aminoglycoside (AG). Mechanism studies indicated that the CL responses of the CL film to GEN should be attributed to the competitive binding of GEN with cobalt ions in the CL film, resulting in the loss of catalytic centers in the ABEI-H2O2 CL reaction and a subsequent decrease of CL signals. The CL film exhibited good sensitivity for the detection of AGs such as GEN, neomycin (NEO), streptomycin (STR), kanamycin (KAN), and amikacin (AMI), with LODs of 2.4 nM, 7.8 nM, 2.4 nM, 9.6 nM, and 3.0 nM, respectively. The proposed heterogeneous sensing platform could be employed for the detection of AGs in different dosage forms and complex matrices such as natural water, serum, and milk, possessing advantages including high sensitivity, good specificity, and high efficiency.
- 3 April 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (17) , 3517-3525
Rational design to improve the detection sensitivity of sandwich-type lateral flow immunoassays
This study presents two strategies to improve the detection sensitivity of the gold nanoparticle (Au NP)-based sandwich-type lateral flow immunoassay (LFIA) using the typical human chorionic gonadotropin (hCG) LFIA as the model. One efficient way is to adjust the size of Au NPs used as the label in the LFIA. Four kinds of Au NPs with different sizes (80, 110, 130, and 160 nm) were synthesized using a seed-mediated growth method, and the influence of nanoparticle size on the detection sensitivity of hCG was investigated. The results revealed that 110 nm Au NPs offered the highest detection sensitivity. Under the optimized conditions, the limit of detection (LOD) for hCG protein using Au NPs with a diameter around 110 nm as the signal probe was 5 mIU mL−1. Another powerful strategy discovered accidentally involves the introduction of an additional glass cellulose pad on the MAX-line label. The MAX-line label, which features an adhesive backing and a marked line indicating the maximum sample volume, is assembled on the test strip covering the sample pad and conjugate pad. We found that the introduction of an additional glass cellulose pad with a length of 6 mm on the MAX-line label could achieve a visual LOD of 1 mIU mL−1 for the detection of hCG. We assume that the improvement in detection sensitivity may be attributed to the increased sample carrying capacity and the extended flow time of gold nanoprobes, as the gold probes may diffuse from the conjugate pad into the enhancement pad upon rehydration. The developed LFIA also exhibited good reproducibility and stability. We believe that the developed strategies, particularly the approach of adding an enhancement pad on the MAX-line label, will serve as a general method applicable to other types of LFIAs to improve the sensitivity of target analytes.
- 3 April 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (17) , 3517-3525
Rational design to improve the detection sensitivity of sandwich-type lateral flow immunoassays
This study presents two strategies to improve the detection sensitivity of the gold nanoparticle (Au NP)-based sandwich-type lateral flow immunoassay (LFIA) using the typical human chorionic gonadotropin (hCG) LFIA as the model. One efficient way is to adjust the size of Au NPs used as the label in the LFIA. Four kinds of Au NPs with different sizes (80, 110, 130, and 160 nm) were synthesized using a seed-mediated growth method, and the influence of nanoparticle size on the detection sensitivity of hCG was investigated. The results revealed that 110 nm Au NPs offered the highest detection sensitivity. Under the optimized conditions, the limit of detection (LOD) for hCG protein using Au NPs with a diameter around 110 nm as the signal probe was 5 mIU mL−1. Another powerful strategy discovered accidentally involves the introduction of an additional glass cellulose pad on the MAX-line label. The MAX-line label, which features an adhesive backing and a marked line indicating the maximum sample volume, is assembled on the test strip covering the sample pad and conjugate pad. We found that the introduction of an additional glass cellulose pad with a length of 6 mm on the MAX-line label could achieve a visual LOD of 1 mIU mL−1 for the detection of hCG. We assume that the improvement in detection sensitivity may be attributed to the increased sample carrying capacity and the extended flow time of gold nanoprobes, as the gold probes may diffuse from the conjugate pad into the enhancement pad upon rehydration. The developed LFIA also exhibited good reproducibility and stability. We believe that the developed strategies, particularly the approach of adding an enhancement pad on the MAX-line label, will serve as a general method applicable to other types of LFIAs to improve the sensitivity of target analytes.
- 29 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-13
A sensitive gold nanoflower-based lateral flow assay coupled with gold staining technique for the detection of SARS-CoV-2 antigen
An enhanced lateral flow assay (LFA) is presented for rapid and highly sensitive detection of acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antigens with gold nanoflowers (Au NFs) as signaling markers and gold enhancement to amplify the signal intensities. First, the effect of the morphology of gold nanomaterials on the sensitivity of LFA detection was investigated. The results showed that Au NFs prepared by the seed growth method showed a 5-fold higher detection sensitivity than gold nanoparticles (Au NPs) of the same particle size, which may benefit from the higher extinction coefficient and larger specific surface area of Au NFs. Under the optimized experimental conditions, the Au NFs-based LFA exhibited a detection limit (LOD) of 25 pg mL−1 for N protein using 135 nm Au NFs as the signaling probes. The signal was further amplified by using a gold enhancement strategy, and the LOD for the detection of N protein achieved was 5 pg mL−1. The established LFA also exhibited good repeatability and stability and showed applicability in the diagnosis of SARS-CoV-2 infection. Graphical Abstract
- 29 June 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (7) , 1-13
A sensitive gold nanoflower-based lateral flow assay coupled with gold staining technique for the detection of SARS-CoV-2 antigen
An enhanced lateral flow assay (LFA) is presented for rapid and highly sensitive detection of acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antigens with gold nanoflowers (Au NFs) as signaling markers and gold enhancement to amplify the signal intensities. First, the effect of the morphology of gold nanomaterials on the sensitivity of LFA detection was investigated. The results showed that Au NFs prepared by the seed growth method showed a 5-fold higher detection sensitivity than gold nanoparticles (Au NPs) of the same particle size, which may benefit from the higher extinction coefficient and larger specific surface area of Au NFs. Under the optimized experimental conditions, the Au NFs-based LFA exhibited a detection limit (LOD) of 25 pg mL−1 for N protein using 135 nm Au NFs as the signaling probes. The signal was further amplified by using a gold enhancement strategy, and the LOD for the detection of N protein achieved was 5 pg mL−1. The established LFA also exhibited good repeatability and stability and showed applicability in the diagnosis of SARS-CoV-2 infection. Graphical Abstract
- 17 May 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (9) , 1571-1591
Optical lateral flow assays in early diagnosis of SARS-CoV-2 infection
So far, the 2019 novel coronavirus (COVID-19) is spreading widely worldwide. The early diagnosis of infection by the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is essential to provide timely treatment and prevent its further spread. Lateral flow assays (LFAs) have the advantages of rapid detection, simple operation, low cost, ease of mass production, and no need for special devices and professional operators, which make them suitable for self-testing at home. This review focuses on the early diagnosis of SARS-CoV-2 infection based on optical LFAs including colorimetric, fluorescent (FL), chemiluminescent (CL), and surface-enhanced Raman scattering (SERS) LFAs for the detection of SARS-CoV-2 antigens and nucleic acids. The types of recognition components, detection modes used for antigen detection, labels employed in different optical LFAs, and strategies to improve the detection sensitivity of LFAs were reviewed. Meanwhile, LFAs coupled with different nucleic acid amplification techniques and CRISPR–Cas systems for the detection of SARS-CoV-2 nucleic acids were summarized. We hope this review provides research mentalities for developing highly sensitive LFAs that can be used in home self-testing for the early diagnosis of SARS-CoV-2 infection. Graphical abstract
- 17 May 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (9) , 1571-1591
Optical lateral flow assays in early diagnosis of SARS-CoV-2 infection
So far, the 2019 novel coronavirus (COVID-19) is spreading widely worldwide. The early diagnosis of infection by the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is essential to provide timely treatment and prevent its further spread. Lateral flow assays (LFAs) have the advantages of rapid detection, simple operation, low cost, ease of mass production, and no need for special devices and professional operators, which make them suitable for self-testing at home. This review focuses on the early diagnosis of SARS-CoV-2 infection based on optical LFAs including colorimetric, fluorescent (FL), chemiluminescent (CL), and surface-enhanced Raman scattering (SERS) LFAs for the detection of SARS-CoV-2 antigens and nucleic acids. The types of recognition components, detection modes used for antigen detection, labels employed in different optical LFAs, and strategies to improve the detection sensitivity of LFAs were reviewed. Meanwhile, LFAs coupled with different nucleic acid amplification techniques and CRISPR–Cas systems for the detection of SARS-CoV-2 nucleic acids were summarized. We hope this review provides research mentalities for developing highly sensitive LFAs that can be used in home self-testing for the early diagnosis of SARS-CoV-2 infection. Graphical abstract
- 31 May 2023
- Published by Springer Nature in Carbon Letters
- Vol. 33 (4) , 1045-1055
Preparation and application of graphene oxide nanocomposites loaded with enzymes and liposomes
- 31 May 2023
- Published by Springer Nature in Carbon Letters
- Vol. 33 (4) , 1045-1055
Preparation and application of graphene oxide nanocomposites loaded with enzymes and liposomes
- 25 May 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (9) , 1541-1550
A turn-on chemiluminescent assay for alkaline phosphatase using two-dimensional Fe-centered metal–organic frameworks as the signaling probe
Alkaline phosphatase (ALP) is an essential enzyme involved in cell phosphorus metabolism. Developing sensitive and accurate ALP quantitative assays is significant. In this study, a turn-on chemiluminescence (CL) analysis platform for the detection of ALP activity in human serum was established based on two-dimensional (2D) Fe-centered metal–organic frameworks with 1,3,5-benzene tricarboxylic acid as ligands (denoted as 2D Fe-BTC). The 2D Fe-BTC as the signaling probe reacts with ascorbic acid forming reduced Fe-BTC which catalyzes the luminol CL reaction producing a strong CL signal. The 2D Fe-BTC-based luminol CL reaction exhibited good CL responses when the concentration of ascorbic acid was in the range of 5–500 nM. By employing magnesium ascorbyl phosphate (MAP) as the substrate which can be hydrolyzed by ALP to generate ascorbic acid, a turn-on CL assay for the detection of ALP was established. Under optimal conditions, as low as 0.00046 U L−1 of ALP could be sensitively detected with a linear range of 0.001–0.1 U L−1. ALP in human serum can be detected after a simple dilution process without any other pretreatment. Graphical abstract
- 25 May 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (9) , 1541-1550
A turn-on chemiluminescent assay for alkaline phosphatase using two-dimensional Fe-centered metal–organic frameworks as the signaling probe
Alkaline phosphatase (ALP) is an essential enzyme involved in cell phosphorus metabolism. Developing sensitive and accurate ALP quantitative assays is significant. In this study, a turn-on chemiluminescence (CL) analysis platform for the detection of ALP activity in human serum was established based on two-dimensional (2D) Fe-centered metal–organic frameworks with 1,3,5-benzene tricarboxylic acid as ligands (denoted as 2D Fe-BTC). The 2D Fe-BTC as the signaling probe reacts with ascorbic acid forming reduced Fe-BTC which catalyzes the luminol CL reaction producing a strong CL signal. The 2D Fe-BTC-based luminol CL reaction exhibited good CL responses when the concentration of ascorbic acid was in the range of 5–500 nM. By employing magnesium ascorbyl phosphate (MAP) as the substrate which can be hydrolyzed by ALP to generate ascorbic acid, a turn-on CL assay for the detection of ALP was established. Under optimal conditions, as low as 0.00046 U L−1 of ALP could be sensitively detected with a linear range of 0.001–0.1 U L−1. ALP in human serum can be detected after a simple dilution process without any other pretreatment. Graphical abstract
- 5 April 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (8) , 1223-1231
Ultrasensitive colorimetric detection of tetracyclines based on in-situ growth of gold nanoflowers
A colorimetric method based on in-situ generation of gold nanoflowers for the detection of tetracyclines (TCs) was proposed. We found that gold nanoflowers could be formed in the HAuCl4-NH2OH redox reaction directly without the addition of small-sized gold nanoparticles (Au NPs) as seeds when an alkaline borax buffer solution was employed as the reaction medium. Interestingly, the shape and size of the generated gold nanoflowers were regulated with TC. Briefly, large flower-like gold nanoparticles were formed with a low concentration of TC while small spherical gold nanoparticles were generated with a high concentration of TC. The generated gold nanoflowers exhibited different surface plasmon absorption (SPR) properties. Thus, a simple and rapid colorimetric method was established for the detection of TC antibiotics. This method exhibited high sensitivity for the detection of TC, oxytetracycline (OTC), and doxycycline (DC) with detection limits of 2.23 nM, 1.19 nM, and 5.81 nM, respectively. The proposed colorimetric method was applied to the determination of TC in both milk samples and water samples. Graphical Abstract
- 5 April 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (8) , 1223-1231
Ultrasensitive colorimetric detection of tetracyclines based on in-situ growth of gold nanoflowers
A colorimetric method based on in-situ generation of gold nanoflowers for the detection of tetracyclines (TCs) was proposed. We found that gold nanoflowers could be formed in the HAuCl4-NH2OH redox reaction directly without the addition of small-sized gold nanoparticles (Au NPs) as seeds when an alkaline borax buffer solution was employed as the reaction medium. Interestingly, the shape and size of the generated gold nanoflowers were regulated with TC. Briefly, large flower-like gold nanoparticles were formed with a low concentration of TC while small spherical gold nanoparticles were generated with a high concentration of TC. The generated gold nanoflowers exhibited different surface plasmon absorption (SPR) properties. Thus, a simple and rapid colorimetric method was established for the detection of TC antibiotics. This method exhibited high sensitivity for the detection of TC, oxytetracycline (OTC), and doxycycline (DC) with detection limits of 2.23 nM, 1.19 nM, and 5.81 nM, respectively. The proposed colorimetric method was applied to the determination of TC in both milk samples and water samples. Graphical Abstract