Farhan Mahmood
Farhan Mahmood has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Luigi Vanfretti
Rensselaer Polytechnic Institute
3 shared publications - Hossein Hooshyar
Advanced Grid Innovation Laboratory for Energy (AGILe), New York Power Authority (NYPA), White Plains, NY, USA
2 shared publications - Fabrizio Sossan
DESL, Ecole Polytechnique Federale de Lausanne Faculte des Sciences et Techniques de l\'Ingenieur, 111838 Lausanne, Vaud Switzerland 1015
1 shared publication Hossein Hooshyar
Rensselaer Polytechnic Institute (RPI), 110 8th St. 12180, Troy, NY
1 shared publication- Hossein Hooshyar
KTH Royal Inst Technol, Stockholm, Sweden
1 shared publication - Jose Ignacio Candela
Renewable Electrical Energy Systems (SEER), Technical University of Catalonia, Terrassa, Spain
1 shared publication
Latest Publications
- 11 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (6) , 6714-6723
Measurement-Based Network Clustering for Active Distribution Systems
This paper presents a Network Clustering (NC) method for active distribution networks (ADNs). Following the outage of a section of an ADN, the method identifies and forms an optimum cluster of microgrids within the section. The optimum cluster is determined from a set of candidate microgrid clusters by estimating the following metrics: total power loss, voltage deviations and minimum load shedding. To compute these metrics, equivalent circuits of the clusters are estimated using measured data provided by Phasor Measurement Units (PMUs). Hence, the proposed NC method determines the optimum microgrid cluster without requiring information about the network’s topology and its components. The proposed method is tested by simulating a study network in a real-time simulator coupled to physical PMUs and a prototype algorithm implementation, also executing in real-time.
- 11 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (6) , 6714-6723
Measurement-Based Network Clustering for Active Distribution Systems
This paper presents a Network Clustering (NC) method for active distribution networks (ADNs). Following the outage of a section of an ADN, the method identifies and forms an optimum cluster of microgrids within the section. The optimum cluster is determined from a set of candidate microgrid clusters by estimating the following metrics: total power loss, voltage deviations and minimum load shedding. To compute these metrics, equivalent circuits of the clusters are estimated using measured data provided by Phasor Measurement Units (PMUs). Hence, the proposed NC method determines the optimum microgrid cluster without requiring information about the network’s topology and its components. The proposed method is tested by simulating a study network in a real-time simulator coupled to physical PMUs and a prototype algorithm implementation, also executing in real-time.
- Open Access
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 4042-4053
Experimental Validation of a Steady State Model Synthesis Method for a Three-Phase Unbalanced Active Distribution Network Feeder
This paper presents the field validation of a method that performs steady-state model synthesis (SSMS) of active distribution networks using syncrophasor measurements. The validation is performed by applying the SSMS method on a real active distribution feeder network by utilizing the measurements from real Phasor Measurement Units (PMUs) installed at the EPFL campus. An extended version of Total Vector Error (TVE) and a power flow comparison at the PMU buses are used as performance assessment metrics. A real-time hardware-in-the-loop simulations setup at Distributed Energy System Laboratory (DESL) is used for further performance assessment of the SSMS application. The effectiveness of the SSMS application is demonstrated by testing it extensively for several different case studies.
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 4042-4053
Open AccessExperimental Validation of a Steady State Model Synthesis Method for a Three-Phase Unbalanced Active Distribution Network Feeder
This paper presents the field validation of a method that performs steady-state model synthesis (SSMS) of active distribution networks using syncrophasor measurements. The validation is performed by applying the SSMS method on a real active distribution feeder network by utilizing the measurements from real Phasor Measurement Units (PMUs) installed at the EPFL campus. An extended version of Total Vector Error (TVE) and a power flow comparison at the PMU buses are used as performance assessment metrics. A real-time hardware-in-the-loop simulations setup at Distributed Energy System Laboratory (DESL) is used for further performance assessment of the SSMS application. The effectiveness of the SSMS application is demonstrated by testing it extensively for several different case studies.
- Open Access
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Sensitivity analysis of a PMU-fed steady state model synthesis method for active distribution networks
The purpose of this paper is to carry out sensitivity analysis of a method that performs steady state model synthesis (SSMS) of active distribution networks using Syncrophasor Measurements. An extended version of the Total Vector Error (TVE) is used as a metric to evaluate how sensitive the output of the SSMS method is to the changes in the inputs to the method. Location of PMUs in the system, system operating point, and occurrence of different disturbances are considered as the input to the SSMS method. The sensitivity analysis is performed through several case studies each containing changes in one of the inputs.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Open AccessSensitivity analysis of a PMU-fed steady state model synthesis method for active distribution networks
The purpose of this paper is to carry out sensitivity analysis of a method that performs steady state model synthesis (SSMS) of active distribution networks using Syncrophasor Measurements. An extended version of the Total Vector Error (TVE) is used as a metric to evaluate how sensitive the output of the SSMS method is to the changes in the inputs to the method. Location of PMUs in the system, system operating point, and occurrence of different disturbances are considered as the input to the SSMS method. The sensitivity analysis is performed through several case studies each containing changes in one of the inputs.
- Open Access
Extracting Steady State Components from Synchrophasor Data Using Kalman Filters
Data from phasor measurement units (PMUs) may be exploited to provide steady state information to the applications which require it. As PMU measurements may contain errors and missing data, the paper presents the application of a Kalman Filter technique for real-time data processing. PMU data captures the power system’s response at different time-scales, which are generated by different types of power system events; the presented Kalman Filter methods have been applied to extract the steady state components of PMU measurements that can be fed to steady state applications. Two KF-based methods have been proposed, i.e., a windowing-based KF method and “the modified KF”. Both methods are capable of reducing noise, compensating for missing data and filtering outliers from input PMU signals. A comparison of proposed methods has been carried out using the PMU data generated from a hardware-in-the-loop (HIL) experimental setup. In addition, a performance analysis of the proposed methods is performed using an evaluation metric.
Open AccessExtracting Steady State Components from Synchrophasor Data Using Kalman Filters
Data from phasor measurement units (PMUs) may be exploited to provide steady state information to the applications which require it. As PMU measurements may contain errors and missing data, the paper presents the application of a Kalman Filter technique for real-time data processing. PMU data captures the power system’s response at different time-scales, which are generated by different types of power system events; the presented Kalman Filter methods have been applied to extract the steady state components of PMU measurements that can be fed to steady state applications. Two KF-based methods have been proposed, i.e., a windowing-based KF method and “the modified KF”. Both methods are capable of reducing noise, compensating for missing data and filtering outliers from input PMU signals. A comparison of proposed methods has been carried out using the PMU data generated from a hardware-in-the-loop (HIL) experimental setup. In addition, a performance analysis of the proposed methods is performed using an evaluation metric.