Litao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Litao Zhang has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Zhenlu Zhang
Clinical Laboratory, Wuhan Asia Heart Hospital, Wuhan 430022, China
13 shared publications Zhenlu Zhang
Clinical Laboratory Wuhan Asia General Hospital Affiliate to Wuhan University of Science and Technology Wuhan China
5 shared publicationsHui Wang
Clinical Laboratory , Wuhan Asia General Hospital Affiliated to Wuhan University of Science and Technology , Wuhan , China
4 shared publicationsLing Li
Laboratory Medicine Centre , Wuhan Asia Heart Hospital Affiliated to Wuhan University of Science and Technology , Wuhan , China
4 shared publicationsXin Shu
Clinical Laboratory , Wuhan Asia General Hospital Affiliated to Wuhan University of Science and Technology , Wuhan , China
4 shared publicationsYisha Jing
Clinical Laboratory , Wuhan Asia General Hospital Affiliated to Wuhan University of Science and Technology , Wuhan , China
4 shared publications
Latest Publications
- Open Access
- 18 February 2026
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 40 (6) , e70184
Resolving Bivalirudin Interference on Fibrinogen Testing by the Use of Activated Carbon
Background: Direct thrombin inhibitors may lead to falsely low fibrinogen results. The interference of bivalirudin on fibrinogen assays has not been thoroughly evaluated. This study investigates the interference of bivalirudin on fibrinogen detection and the potential use of activated carbon to address this issue. Methods: Normal pooled plasma from 20 healthy subjects was spiked with increasing bivalirudin concentrations (0–6.4 μg/mL). Interference of bivalirudin on fibrinogen testing was evaluated by comparing three Clauss‐method assays (HemosIL Fibrinogen‐C XL; STA‐Fibrinogen; Dade Thrombin) to an immunoassay (N Antiserum to Human Fibrinogen reagent, NAHF). Activated partial thromboplastin time (APTT) and fibrinogen results were analyzed before and after the addition of activated carbon (AC) to evaluate the absorption of bivalirudin by AC. Results: The NAHF immunoassay remained unaffected by bivalirudin ( p = 0.27). All three Clauss‐methods assays showed a significant downward trend with the increase of bivalirudin concentration (STA‐Fibrinogen: p = 0.012, Dade Thrombin: p < 0.001, Fibrinogen‐C XL: p < 0.001). When compared to their respective baselines, STA‐Fibrinogen exhibited a reduction of 16%, Dade Thrombin showed a reduction of 40%, and Fibrinogen‐C XL displayed a decrease of up to 89%. Neither STA‐Fibrinogen nor Dade Thrombin displayed a significant downward trend when the APTT ratio did not exceed 2.5. After the addition of AC, SynthASil APTT and HemosIL Fibrinogen‐C XL levels of all samples containing varying concentrations of bivalirudin returned to near baseline. Conclusion: The influences of bivalirudin on fibrinogen assays vary significantly. Activated carbon can effectively remove bivalirudin from plasma, thereby eliminating its interference on fibrinogen testing.
- 18 February 2026
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 40 (6) , e70184
Open AccessResolving Bivalirudin Interference on Fibrinogen Testing by the Use of Activated Carbon
Background: Direct thrombin inhibitors may lead to falsely low fibrinogen results. The interference of bivalirudin on fibrinogen assays has not been thoroughly evaluated. This study investigates the interference of bivalirudin on fibrinogen detection and the potential use of activated carbon to address this issue. Methods: Normal pooled plasma from 20 healthy subjects was spiked with increasing bivalirudin concentrations (0–6.4 μg/mL). Interference of bivalirudin on fibrinogen testing was evaluated by comparing three Clauss‐method assays (HemosIL Fibrinogen‐C XL; STA‐Fibrinogen; Dade Thrombin) to an immunoassay (N Antiserum to Human Fibrinogen reagent, NAHF). Activated partial thromboplastin time (APTT) and fibrinogen results were analyzed before and after the addition of activated carbon (AC) to evaluate the absorption of bivalirudin by AC. Results: The NAHF immunoassay remained unaffected by bivalirudin ( p = 0.27). All three Clauss‐methods assays showed a significant downward trend with the increase of bivalirudin concentration (STA‐Fibrinogen: p = 0.012, Dade Thrombin: p < 0.001, Fibrinogen‐C XL: p < 0.001). When compared to their respective baselines, STA‐Fibrinogen exhibited a reduction of 16%, Dade Thrombin showed a reduction of 40%, and Fibrinogen‐C XL displayed a decrease of up to 89%. Neither STA‐Fibrinogen nor Dade Thrombin displayed a significant downward trend when the APTT ratio did not exceed 2.5. After the addition of AC, SynthASil APTT and HemosIL Fibrinogen‐C XL levels of all samples containing varying concentrations of bivalirudin returned to near baseline. Conclusion: The influences of bivalirudin on fibrinogen assays vary significantly. Activated carbon can effectively remove bivalirudin from plasma, thereby eliminating its interference on fibrinogen testing.
- 26 November 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (4) , 932-940
Performance evaluation of a new high-sensitivity cardiac troponin T assay: hs-cTnT (CLIA) assay
Objectives: The Fourth Universal Definition of Myocardial Infarction recommends high-sensitivity cardiac troponin (hs-cTn) as the preferred biomarker for diagnosing myocardial infarction. This study evaluated the analytical and clinical performance of a novel hs-cTnT chemiluminescence immunoassay (CLIA) developed by Mindray. Methods: Analytical performance characteristics including precision, sensitivity (limit of detection [LoD] and limit of quantification [LoQ]), imprecision profile, linearity, sample type comparison, method comparison, and potential interferences were assessed. Sex-specific 99th percentile upper reference limits (URLs) were established in 895 healthy individuals. Clinical diagnostic performance was evaluated in 559 patients with suspected acute myocardial infarction and compared with the Roche hs-cTnT assay. Results: The Mindray assay showed excellent precision (repeatability CV≤1.99 %, within-laboratory precision CV≤6.11 %), superior sensitivity (LoD: 1.4 ng/L; LoQ: 2.4 ng/L), and linearity (r=0.9978), along with robust performance against common and immunological interferences. Using the manufacturer-claimed LoD of 2.0 ng/L, measurable values were found in 99.36 % of males, 83.26 % of females, and 91.48 % overall, meeting criteria for high-sensitivity assays. The derived sex-specific 99th percentiles were 18.6 ng/L (males), 9.6 ng/L (females), and 16.0 ng/L (overall). In the clinical cohort, the assay showed 100.0 % sensitivity, 83.3 % specificity, 80.0 % PPV, 100.0 % NPV, and an AUC of 0.988, comparable to the Roche Gen 5 hs-cTnT assay. Conclusions: The Mindray hs-cTnT (CLIA) assay meets high-sensitivity assay criteria and demonstrates robust analytical and diagnostic performance, offering a reliable alternative to the Roche Gen 5 assay for clinical evaluation of myocardial injury.
- 26 November 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (4) , 932-940
Performance evaluation of a new high-sensitivity cardiac troponin T assay: hs-cTnT (CLIA) assay
Objectives: The Fourth Universal Definition of Myocardial Infarction recommends high-sensitivity cardiac troponin (hs-cTn) as the preferred biomarker for diagnosing myocardial infarction. This study evaluated the analytical and clinical performance of a novel hs-cTnT chemiluminescence immunoassay (CLIA) developed by Mindray. Methods: Analytical performance characteristics including precision, sensitivity (limit of detection [LoD] and limit of quantification [LoQ]), imprecision profile, linearity, sample type comparison, method comparison, and potential interferences were assessed. Sex-specific 99th percentile upper reference limits (URLs) were established in 895 healthy individuals. Clinical diagnostic performance was evaluated in 559 patients with suspected acute myocardial infarction and compared with the Roche hs-cTnT assay. Results: The Mindray assay showed excellent precision (repeatability CV≤1.99 %, within-laboratory precision CV≤6.11 %), superior sensitivity (LoD: 1.4 ng/L; LoQ: 2.4 ng/L), and linearity (r=0.9978), along with robust performance against common and immunological interferences. Using the manufacturer-claimed LoD of 2.0 ng/L, measurable values were found in 99.36 % of males, 83.26 % of females, and 91.48 % overall, meeting criteria for high-sensitivity assays. The derived sex-specific 99th percentiles were 18.6 ng/L (males), 9.6 ng/L (females), and 16.0 ng/L (overall). In the clinical cohort, the assay showed 100.0 % sensitivity, 83.3 % specificity, 80.0 % PPV, 100.0 % NPV, and an AUC of 0.988, comparable to the Roche Gen 5 hs-cTnT assay. Conclusions: The Mindray hs-cTnT (CLIA) assay meets high-sensitivity assay criteria and demonstrates robust analytical and diagnostic performance, offering a reliable alternative to the Roche Gen 5 assay for clinical evaluation of myocardial injury.
- 12 September 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (2) , 505-512
Comparison of the cardiac troponin I-cardiac troponin T-troponin C complex and cardiac troponin I and T in distinguishing myocardial infarction using a single sample at presentation
Objectives: The potential relationship between cardiac troponin (cTn) composition and etiologies of myocardial injury may provide diagnostic insights for myocardial infarction (MI). We compared the performance of novel ternary cTnI–cTnT–TnC complex (ITC) assays with high-sensitivity (hs)-cTnI and hs-cTnT in differentiating MI patients at presentation. Methods: Plasma samples from 1,210 patients with suspected MI were collected. Major cTn forms were quantified using long-cTnT ITC complex, hs-total ITC complex, hs-cTnI and hs-cTnT assay. We compared the assay performance based on the 99th percentile upper reference limits (URLs), evaluated their area under the receiver operating characteristic curve (AUC), and assessed their ability to differentiate MI using established cut-off values. Results: A total of 138 (11.4 %) patients were diagnosed with MI. 86 % patients had long-cTnT ITC complex concentration below the 99th percentile URLs (sensitivity: 0.818, specificity: 0.943, NPV: 0.975, PPV: 0.649). AUC was 0.959 for long-cTnT ITC complex, comparable to hs-cTnI (0.953) and superior to hs-total ITC complex (0.889) and hs-cTnT (0.927). Using established cut-off values, the long-cTnT ITC complex assay classified 10 % of patients as rule-in and 52 % as rule-out (sensitivity: 0.993, NPV: 0.998, specificity: 0.972, PPV: 0.760), which was comparable to hs-cTnI and better than hs-total ITC complex and hs-cTnT. In early-presenting patients, the long-cTnT ITC complex demonstrated enhanced discrimination and improved diagnostic performance. Conclusions: The long-cTnT ITC complex assay demonstrated performance comparable to hs-cTnI and superior to hs-total ITC complex and hs-cTnT in distinguishing MI using a single sample at presentation. These findings suggest its potential utility in improving risk stratification and triage strategies, particularly among early-presenting patients.
- 12 September 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (2) , 505-512
Comparison of the cardiac troponin I-cardiac troponin T-troponin C complex and cardiac troponin I and T in distinguishing myocardial infarction using a single sample at presentation
Objectives: The potential relationship between cardiac troponin (cTn) composition and etiologies of myocardial injury may provide diagnostic insights for myocardial infarction (MI). We compared the performance of novel ternary cTnI–cTnT–TnC complex (ITC) assays with high-sensitivity (hs)-cTnI and hs-cTnT in differentiating MI patients at presentation. Methods: Plasma samples from 1,210 patients with suspected MI were collected. Major cTn forms were quantified using long-cTnT ITC complex, hs-total ITC complex, hs-cTnI and hs-cTnT assay. We compared the assay performance based on the 99th percentile upper reference limits (URLs), evaluated their area under the receiver operating characteristic curve (AUC), and assessed their ability to differentiate MI using established cut-off values. Results: A total of 138 (11.4 %) patients were diagnosed with MI. 86 % patients had long-cTnT ITC complex concentration below the 99th percentile URLs (sensitivity: 0.818, specificity: 0.943, NPV: 0.975, PPV: 0.649). AUC was 0.959 for long-cTnT ITC complex, comparable to hs-cTnI (0.953) and superior to hs-total ITC complex (0.889) and hs-cTnT (0.927). Using established cut-off values, the long-cTnT ITC complex assay classified 10 % of patients as rule-in and 52 % as rule-out (sensitivity: 0.993, NPV: 0.998, specificity: 0.972, PPV: 0.760), which was comparable to hs-cTnI and better than hs-total ITC complex and hs-cTnT. In early-presenting patients, the long-cTnT ITC complex demonstrated enhanced discrimination and improved diagnostic performance. Conclusions: The long-cTnT ITC complex assay demonstrated performance comparable to hs-cTnI and superior to hs-total ITC complex and hs-cTnT in distinguishing MI using a single sample at presentation. These findings suggest its potential utility in improving risk stratification and triage strategies, particularly among early-presenting patients.
- 23 June 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (1) , 205-214
An automatic chemiluminescence immunoassay for a novel biomarker NT-IGFBP-4: analytical performance and clinical relevance in heart failure
Objectives: Insulin-like growth factor binding protein-4 (IGFBP-4) fragments are reported as emerging biomarkers for cardiovascular disease (CVD) risk assessment. To ensure data reliability and improve clinical application, the first automatic chemiluminescent immunoassay (CLIA) for NT-IGFBP-4 was developed and its distribution across CVDs was evaluated in this study. Methods: Fragment-specific monoclonal antibodies were used to develop immunoassay, followed by comprehensive analytical validation, including limit of blank (LoB), limit of detection (LoD), limit of quantification (LoQ), linearity, specificity, precision, sample type compatibility, and stability. Reference intervals for NT-IGFBP-4 were established in healthy individuals, with variations analyzed based on gender, age, body mass index (BMI), and renal function. Additionally, NT-IGFBP-4 distribution was explored in CVD patients. Results: The newly developed chemiluminescence assay demonstrated high specificity for NT-IGFBP-4, with excellent sensitivity (LoQ=1.0 ng/mL), broad linearity (1.0–1,000.0 ng/mL), and strong precision (CV≤3.0 %). It showed no interference from common endogenous substances, maintained compatible with various sample types, and remained stable under different storage conditions. Reference intervals showed slight variations by gender and age, with levels being independent of BMI but influenced by renal function. NT-IGFBP-4 levels were significantly elevated in CVDs, especially in heart failure, correlating with NYHA classification and LVEF (%), with higher levels indicating worse cardiac function. Conclusions: The new automatic NT-IGFBP-4 (CLIA) assay offers a highly specific, sensitive and precise method for quantifying IGFBP-4 fragments. Its validated performance and disease association findings would enhance its diagnostic and prognostic potential in CVD research, particularly in heart failure.
- 23 June 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (1) , 205-214
An automatic chemiluminescence immunoassay for a novel biomarker NT-IGFBP-4: analytical performance and clinical relevance in heart failure
Objectives: Insulin-like growth factor binding protein-4 (IGFBP-4) fragments are reported as emerging biomarkers for cardiovascular disease (CVD) risk assessment. To ensure data reliability and improve clinical application, the first automatic chemiluminescent immunoassay (CLIA) for NT-IGFBP-4 was developed and its distribution across CVDs was evaluated in this study. Methods: Fragment-specific monoclonal antibodies were used to develop immunoassay, followed by comprehensive analytical validation, including limit of blank (LoB), limit of detection (LoD), limit of quantification (LoQ), linearity, specificity, precision, sample type compatibility, and stability. Reference intervals for NT-IGFBP-4 were established in healthy individuals, with variations analyzed based on gender, age, body mass index (BMI), and renal function. Additionally, NT-IGFBP-4 distribution was explored in CVD patients. Results: The newly developed chemiluminescence assay demonstrated high specificity for NT-IGFBP-4, with excellent sensitivity (LoQ=1.0 ng/mL), broad linearity (1.0–1,000.0 ng/mL), and strong precision (CV≤3.0 %). It showed no interference from common endogenous substances, maintained compatible with various sample types, and remained stable under different storage conditions. Reference intervals showed slight variations by gender and age, with levels being independent of BMI but influenced by renal function. NT-IGFBP-4 levels were significantly elevated in CVDs, especially in heart failure, correlating with NYHA classification and LVEF (%), with higher levels indicating worse cardiac function. Conclusions: The new automatic NT-IGFBP-4 (CLIA) assay offers a highly specific, sensitive and precise method for quantifying IGFBP-4 fragments. Its validated performance and disease association findings would enhance its diagnostic and prognostic potential in CVD research, particularly in heart failure.
- Open Access
- 23 April 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (4) , 26992
Association between Stroke History and Clinical Events in Atrial Fibrillation Patients after Valve Replacement
Background: The association between stroke history and clinical events after valve replacement in patients with atrial fibrillation (AF) combined with valvular heart disease (VHD) is unclear. Thus, we sought to investigate the relationship between stroke history and clinical events in patients with AF after valve replacement. Methods: This retrospective cohort study enrolled 746 patients with AF who underwent valve replacement between January 2018 and December 2019 at the Wuhan Asia Heart Hospital. Patient information was collected from the hospital’s electronic medical record system. Patients were categorized based on their stroke history and followed through outpatient visits or by telephone until the occurrence of an endpoint event; the maximum follow-up period was 24 months. Endpoint events included thrombotic events, bleeding, and all-cause mortality. The frequency of thrombotic, hemorrhagic, and fatal events during the follow-up period was compared between the two groups. Independent risk factors for endpoint events were analyzed using multifactorial Cox regression. Results: The analysis included 746 patients. Over a 24-month follow-up period, there were more total adverse events (hazard ratio (HR) = 2.08, 95% confidence interval (CI) 1.06–4.08, p = 0.018), thrombotic events (HR = 10.28, 95% CI 2.85–37.11, p < 0.001), and increased all-cause mortality (HR = 5.74, 95% CI 1.84–17.93, p < 0.001) in the stroke history group than in the non-stroke history group. Fewer bleeding events were observed in the group with a history of stroke (HR = 0.87, 95% CI 0.37–2.04, p = 0.757). A multifactorial Cox regression analysis revealed that a personal history of stroke was an independent risk factor for total adverse events, thrombotic events, and all-cause mortality. Conclusions: Previous stroke history is significantly associated with adverse events in AF patients following valve replacement.
- 23 April 2025
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 26 (4) , 26992
Open AccessAssociation between Stroke History and Clinical Events in Atrial Fibrillation Patients after Valve Replacement
Background: The association between stroke history and clinical events after valve replacement in patients with atrial fibrillation (AF) combined with valvular heart disease (VHD) is unclear. Thus, we sought to investigate the relationship between stroke history and clinical events in patients with AF after valve replacement. Methods: This retrospective cohort study enrolled 746 patients with AF who underwent valve replacement between January 2018 and December 2019 at the Wuhan Asia Heart Hospital. Patient information was collected from the hospital’s electronic medical record system. Patients were categorized based on their stroke history and followed through outpatient visits or by telephone until the occurrence of an endpoint event; the maximum follow-up period was 24 months. Endpoint events included thrombotic events, bleeding, and all-cause mortality. The frequency of thrombotic, hemorrhagic, and fatal events during the follow-up period was compared between the two groups. Independent risk factors for endpoint events were analyzed using multifactorial Cox regression. Results: The analysis included 746 patients. Over a 24-month follow-up period, there were more total adverse events (hazard ratio (HR) = 2.08, 95% confidence interval (CI) 1.06–4.08, p = 0.018), thrombotic events (HR = 10.28, 95% CI 2.85–37.11, p < 0.001), and increased all-cause mortality (HR = 5.74, 95% CI 1.84–17.93, p < 0.001) in the stroke history group than in the non-stroke history group. Fewer bleeding events were observed in the group with a history of stroke (HR = 0.87, 95% CI 0.37–2.04, p = 0.757). A multifactorial Cox regression analysis revealed that a personal history of stroke was an independent risk factor for total adverse events, thrombotic events, and all-cause mortality. Conclusions: Previous stroke history is significantly associated with adverse events in AF patients following valve replacement.
- 7 September 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (2) , 353-360
Evaluation of the analytical and clinical performance of a new high-sensitivity cardiac troponin I assay: hs-cTnI (CLIA) assay
Objectives: Cardiac troponin (cTn) is the key biomarker for diagnosis of acute coronary syndrome (ACS). We performed a complete assessment of the high-sensitivity cardiac troponin I (hs-cTnI) (CLIA) assay on the analytical performance and clinical diagnostic performance, which was compared with Abbott ARCHITECT hs-cTnI assay. Methods: Sex-specific 99th percentile upper reference limits (URLs) were determined from a healthy population of 424 males and 408 females. High-sensitivity performance was assessed by examining the imprecision at sex-specific URLs and the detectable results above LoD in a cohort of healthy population. The diagnostic performance of the hs-cTnI (CLIA) assay was validated in a population of 934 patients with suspected ACS. Results: The 99th percentile URLs were 15.3 ng/L for female, 31.3 ng/L for male and 24.2 ng/L for overall population. The total imprecision near the sex-specific 99th percentile URLs were <5 %. 76.74 % of females, 97.12 % of males and 86.69 % of overall population had cTnI values exceeding the LoD, which met the criteria of high-sensitivity troponin assay. No cross-reactivity or interference was identified. The diagnostic sensitivity, specificity, PPV, NPV, and AUC of hs-cTnI (CLIA) assay were 97.97 , 90.70, 79.02, 99.21 % and 0.9885, respectively, which were comparable to ARCHITECT hs-cTnI assay. Conclusions: hs-cTnI (CLIA) assay is a high-sensitivity troponin I method with high precision, sensitivity and specificity. The clinical diagnostic performance of hs-cTnI (CLIA) is comparable to the established ARCHITECT hs-cTnI assay. Mindray’s hs-cTnI (CLIA) assay is an attractive alternative for diagnosis of myocardial infarction with a high level of accuracy and safety.
- 7 September 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (2) , 353-360
Evaluation of the analytical and clinical performance of a new high-sensitivity cardiac troponin I assay: hs-cTnI (CLIA) assay
Objectives: Cardiac troponin (cTn) is the key biomarker for diagnosis of acute coronary syndrome (ACS). We performed a complete assessment of the high-sensitivity cardiac troponin I (hs-cTnI) (CLIA) assay on the analytical performance and clinical diagnostic performance, which was compared with Abbott ARCHITECT hs-cTnI assay. Methods: Sex-specific 99th percentile upper reference limits (URLs) were determined from a healthy population of 424 males and 408 females. High-sensitivity performance was assessed by examining the imprecision at sex-specific URLs and the detectable results above LoD in a cohort of healthy population. The diagnostic performance of the hs-cTnI (CLIA) assay was validated in a population of 934 patients with suspected ACS. Results: The 99th percentile URLs were 15.3 ng/L for female, 31.3 ng/L for male and 24.2 ng/L for overall population. The total imprecision near the sex-specific 99th percentile URLs were <5 %. 76.74 % of females, 97.12 % of males and 86.69 % of overall population had cTnI values exceeding the LoD, which met the criteria of high-sensitivity troponin assay. No cross-reactivity or interference was identified. The diagnostic sensitivity, specificity, PPV, NPV, and AUC of hs-cTnI (CLIA) assay were 97.97 , 90.70, 79.02, 99.21 % and 0.9885, respectively, which were comparable to ARCHITECT hs-cTnI assay. Conclusions: hs-cTnI (CLIA) assay is a high-sensitivity troponin I method with high precision, sensitivity and specificity. The clinical diagnostic performance of hs-cTnI (CLIA) is comparable to the established ARCHITECT hs-cTnI assay. Mindray’s hs-cTnI (CLIA) assay is an attractive alternative for diagnosis of myocardial infarction with a high level of accuracy and safety.
- Open Access
- 14 January 2023
- Published by Wiley in Cardiovascular Therapeutics
- Vol. 2023, 1-10
Social App to Improve Warfarin Therapy in Post-MHVR Chinese Patients: A Randomized Controlled Trial
Background. Poor anticoagulation quality was a major problem among warfarin-treated patients, which called for innovative and effective methods to improve it. Objective. To investigate whether social app could be used to reduce warfarin-associated adverse events among post-MHVR Chinese patients. Method. 735 warfarin-treated patients ( , 59.9% female) were enrolled and randomized to a social app care group (warfarin therapy was guided by experienced clinicians via a social app) or a routine care group (warfarin therapy was managed through traditional in-office visits) at a 1 : 1 ratio. Ending points (bleeding and thrombotic events) were recorded during an 18-month follow-up period. Results. A total of 718 patients were included in analysis. 57 of them suffered warfarin-associated adverse events, including 30 major bleedings and 27 thrombotic events. The time in the therapeutic range (TTR, Rosendaal method) in the social app group was 71.5%, which was significantly better than 52.6% in the routine care group (difference: 18.8%, 95% CI: 16.8-20.8). Compared with the patients from the social app group, patients under routine care experienced more bleeding (hazard ratio (HR): 2.31, 95% CI: 1.13-4.72). The social app care group had lower variation (0.55 vs. 0.70) in the international normalized ratio (INR) values and fewer incidents of extremely high INR (e.g., , 0.87% vs. 3.42%) than the routine care group. Conclusions. Social app management could significantly improve warfarin control and was associated with a reduction in bleeding risk. This trial was registered with NCT03264937.
- 14 January 2023
- Published by Wiley in Cardiovascular Therapeutics
- Vol. 2023, 1-10
Open AccessSocial App to Improve Warfarin Therapy in Post-MHVR Chinese Patients: A Randomized Controlled Trial
Background. Poor anticoagulation quality was a major problem among warfarin-treated patients, which called for innovative and effective methods to improve it. Objective. To investigate whether social app could be used to reduce warfarin-associated adverse events among post-MHVR Chinese patients. Method. 735 warfarin-treated patients ( , 59.9% female) were enrolled and randomized to a social app care group (warfarin therapy was guided by experienced clinicians via a social app) or a routine care group (warfarin therapy was managed through traditional in-office visits) at a 1 : 1 ratio. Ending points (bleeding and thrombotic events) were recorded during an 18-month follow-up period. Results. A total of 718 patients were included in analysis. 57 of them suffered warfarin-associated adverse events, including 30 major bleedings and 27 thrombotic events. The time in the therapeutic range (TTR, Rosendaal method) in the social app group was 71.5%, which was significantly better than 52.6% in the routine care group (difference: 18.8%, 95% CI: 16.8-20.8). Compared with the patients from the social app group, patients under routine care experienced more bleeding (hazard ratio (HR): 2.31, 95% CI: 1.13-4.72). The social app care group had lower variation (0.55 vs. 0.70) in the international normalized ratio (INR) values and fewer incidents of extremely high INR (e.g., , 0.87% vs. 3.42%) than the routine care group. Conclusions. Social app management could significantly improve warfarin control and was associated with a reduction in bleeding risk. This trial was registered with NCT03264937.
- Open Access
- 23 November 2022
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 6 (8) , e12817
How to use and report data on D‐dimer testing in the COVID‐19 era?
- 23 November 2022
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 6 (8) , e12817
Open AccessHow to use and report data on D‐dimer testing in the COVID‐19 era?
- Open Access
- 22 November 2022
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 6 (8) , e12819
Uncertainties on the prognostic value of admission D‐dimer on venous thromboembolism occurrence in patients with COVID‐19
- 22 November 2022
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 6 (8) , e12819
Open AccessUncertainties on the prognostic value of admission D‐dimer on venous thromboembolism occurrence in patients with COVID‐19
- Open Access
- 20 September 2022
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 6 (6) , e12772
Standardization of D‐dimer reporting in the COVID‐19 era
- 20 September 2022
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 6 (6) , e12772
Open AccessStandardization of D‐dimer reporting in the COVID‐19 era