David Sevillano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Sevillano has a total of 157 co-authors. Here are the top co-authors by number of shared publications:
- Rafael Colmenares
Medical Physics Department, IRYCIS, Hospital Universitario Ramón y Cajal, Madrid, Spain
7 shared publications S. Sancho
6 shared publicationsA. Sanchez-Reyes
Máster en Aplicaciones tecnológicas avanzadas en Oncología Radioterápica, Universidad de Murcia y Fundación Grupo IMO, Madrid, Spain
5 shared publicationsC. Vallejo
5 shared publicationsJ.D. García
5 shared publicationsM. Martín
Hop Univ Ramon & Cajal, Radiat Oncol, Madrid, Spain
5 shared publications
Latest Publications
- 22 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105087
Radiobiological effect of delivery time in treatments of multiple brain metastases with robotic radiosurgery
- 22 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105087
Radiobiological effect of delivery time in treatments of multiple brain metastases with robotic radiosurgery
- 15 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104933
Working thresholds for in-vivo dosimetry in EPIGray based on a clinical, anatomically-stratified study
- 15 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104933
Working thresholds for in-vivo dosimetry in EPIGray based on a clinical, anatomically-stratified study
- Open Access
- 4 November 2024
- Published by CREIN, S.L. in Revista de Física Médica
- Vol. 25 (2) , 11-23
Comparativa de diferentes modelos radiómicos para la clasificación de lesiones adrenales indeterminadas diagnosticadas de forma incidental en TC con contraste
Purpose: A comparison of different machine learning models to discriminate adrenal incidentalomas by CT studies was performed. Methods: Sixty-two different features were obtained from a sample of 61 incidentalomas using the free license software LIFEx and 19 radiomic studies were performed with different models and feature selection methods to obtain the most efficient determination of possible malignancy. For all of them, four cross-validation methods were evaluated. Adenoma contouring was performed in duplicate by different radiologists evaluating all models in both groups. Results: ROC AUC between 0.42 (0.09-0.81) and 0.92 (0.63-1.00), and accuracy of the models between 0.63 (0.43-0.79) and 0.94 (0.82-1.00). The best-performing model was the balanced logistic regression applied to the 14 features with an intraclass coefficient greater than 0.9, with which accuracy of 0.94 (0.74-1.00), ROC AUC of 0.917 (0.63-1.00), benign recall of 0.92 (0.65-1.00) and malignant recall of 1.00 (0.71-1.00) were obtained. Conclusions: The evaluation and validation of different models has allowed us to obtain an efficient radiomic model for the discrimination of adrenal incidentalomas
- 4 November 2024
- Published by CREIN, S.L. in Revista de Física Médica
- Vol. 25 (2) , 11-23
Open AccessComparativa de diferentes modelos radiómicos para la clasificación de lesiones adrenales indeterminadas diagnosticadas de forma incidental en TC con contraste
Purpose: A comparison of different machine learning models to discriminate adrenal incidentalomas by CT studies was performed. Methods: Sixty-two different features were obtained from a sample of 61 incidentalomas using the free license software LIFEx and 19 radiomic studies were performed with different models and feature selection methods to obtain the most efficient determination of possible malignancy. For all of them, four cross-validation methods were evaluated. Adenoma contouring was performed in duplicate by different radiologists evaluating all models in both groups. Results: ROC AUC between 0.42 (0.09-0.81) and 0.92 (0.63-1.00), and accuracy of the models between 0.63 (0.43-0.79) and 0.94 (0.82-1.00). The best-performing model was the balanced logistic regression applied to the 14 features with an intraclass coefficient greater than 0.9, with which accuracy of 0.94 (0.74-1.00), ROC AUC of 0.917 (0.63-1.00), benign recall of 0.92 (0.65-1.00) and malignant recall of 1.00 (0.71-1.00) were obtained. Conclusions: The evaluation and validation of different models has allowed us to obtain an efficient radiomic model for the discrimination of adrenal incidentalomas
- Open Access
- 20 June 2023
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 27, 100215
Are liver contour and bone fusion comparable to fiducials for IGRT in liver SBRT?
- 20 June 2023
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 27, 100215
Open AccessAre liver contour and bone fusion comparable to fiducials for IGRT in liver SBRT?
- Open Access
- 25 April 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e14006
The use of a thin guide‐wire for urethral definition in prostate SBRT treatments with Cyberknife
Purpose: To study and analyze the effect of the use of a thin guide‐wire instead of a Foley catheter for urethral definition in prostate stereotactic body radiation therapy (SBRT) treatments and to compare treatment parameters in both situations.Material and Methods: Thirty‐seven prostate SBRT patients were employed in this study. A Foley catheter was employed in nine of them, and a guide‐wire was employed in the other 28 patients. For each of the 28 patients in which the guide‐wire was employed, a comparison between urethral positions in both situations was performed, allowing for a margin definition of the urethra when a Foley catheter was employed. Displacements of the prostate during treatment were obtained, allowing for an analysis of prostate positions in both situations. Also, different treatment parameters such as the number of treatment interruptions, couch movements performed, and x‐rays needed were gathered.Results: Large differences between urethral positions can be found in the anterior‐posterior (AP) directions compared to those in the lateral (LAT) direction. Differences are also larger in areas closer to the base of the prostate, where margins applied in the case of using a Foley catheter are 16 mm with a mean displacement of 6 mm in the posterior direction. No differences in the treatment parameters were found during treatment in both situations. The difference found in absolute prostate pitch rotations suggests that the Foley catheter provokes a shift of the prostate position, which does not occur when employing the guide‐wire.Conclusions: Foley catheters shift the urethral position, making them a wrong surrogate of the urethra when no catheters are present. The margins needed to assess uncertainties introduced by the use of a Foley catheter are larger than those usually applied. The use of a Foley catheter did not present any additional difficulty during treatment delivery in terms of images employed or interruptions produced.
- 25 April 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e14006
Open AccessThe use of a thin guide‐wire for urethral definition in prostate SBRT treatments with Cyberknife
Purpose: To study and analyze the effect of the use of a thin guide‐wire instead of a Foley catheter for urethral definition in prostate stereotactic body radiation therapy (SBRT) treatments and to compare treatment parameters in both situations.Material and Methods: Thirty‐seven prostate SBRT patients were employed in this study. A Foley catheter was employed in nine of them, and a guide‐wire was employed in the other 28 patients. For each of the 28 patients in which the guide‐wire was employed, a comparison between urethral positions in both situations was performed, allowing for a margin definition of the urethra when a Foley catheter was employed. Displacements of the prostate during treatment were obtained, allowing for an analysis of prostate positions in both situations. Also, different treatment parameters such as the number of treatment interruptions, couch movements performed, and x‐rays needed were gathered.Results: Large differences between urethral positions can be found in the anterior‐posterior (AP) directions compared to those in the lateral (LAT) direction. Differences are also larger in areas closer to the base of the prostate, where margins applied in the case of using a Foley catheter are 16 mm with a mean displacement of 6 mm in the posterior direction. No differences in the treatment parameters were found during treatment in both situations. The difference found in absolute prostate pitch rotations suggests that the Foley catheter provokes a shift of the prostate position, which does not occur when employing the guide‐wire.Conclusions: Foley catheters shift the urethral position, making them a wrong surrogate of the urethra when no catheters are present. The margins needed to assess uncertainties introduced by the use of a Foley catheter are larger than those usually applied. The use of a Foley catheter did not present any additional difficulty during treatment delivery in terms of images employed or interruptions produced.
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 132-140
Application of discrete cosine transform to assess the effect of tumor motion variations on the definition of ITV in lung and liver SBRT
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 132-140
Application of discrete cosine transform to assess the effect of tumor motion variations on the definition of ITV in lung and liver SBRT
- Open Access
- 30 May 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (8) , 56-64
Definition of internal target volumes based on planar X‐ray fluoroscopic images for lung and hepatic stereotactic body radiation therapy. Comparison to inhale/exhale CT technique
Purpose: To compare tumor motion amplitudes measured with 2D fluoroscopic images (FI) and with an inhale/exhale CT (IECT) techniqueMaterials and methods: Tumor motion of 52 patients (39 lung patients and 13 liver patients) was obtained with both FI and IECT. For FI, tumor detection and tracking was performed by means of a software developed by the authors. Motion amplitude and, thus, internal target volume (ITV), were defined to cover the positions where the tumor spends 95% of the time. The algorithm was validated against two different respiratory motion phantoms. Motion amplitude in IECT was defined as the difference in the position of the centroid of the gross tumor volume in the image sets of both treatments.Results: Important differences exist when defining ITVs with FI and IECT. Overall, differences larger than 5 mm were obtained for 49%, 31%, and 9.6% of the patients in Superior‐Inferior (SI), Anterior‐Posterior (AP), and Lateral (LAT) directions, respectively. For tumor location, larger differences were found for tumors in the liver (73.6% SI, 27.3% AP, and 6.7% in LAT had differences larger than 5 mm), while tumors in the upper lobe benefitted less using FI (differences larger than 5 mm were only present in 27.6% (SI), 36.7% (AP), and 0% (LAT) of the patients).Conclusions: Use of FI with the linac built‐in CBCT system is feasible for ITV definition. Large differences between motion amplitudes detected with FI and IECT methods were found. The method presented in this work based on FI could represent an improvement in ITV definition compared to the method based on IECT due to FI permits tumor motion acquisition in a more realistic situation than IECT.
- 30 May 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (8) , 56-64
Open AccessDefinition of internal target volumes based on planar X‐ray fluoroscopic images for lung and hepatic stereotactic body radiation therapy. Comparison to inhale/exhale CT technique
Purpose: To compare tumor motion amplitudes measured with 2D fluoroscopic images (FI) and with an inhale/exhale CT (IECT) techniqueMaterials and methods: Tumor motion of 52 patients (39 lung patients and 13 liver patients) was obtained with both FI and IECT. For FI, tumor detection and tracking was performed by means of a software developed by the authors. Motion amplitude and, thus, internal target volume (ITV), were defined to cover the positions where the tumor spends 95% of the time. The algorithm was validated against two different respiratory motion phantoms. Motion amplitude in IECT was defined as the difference in the position of the centroid of the gross tumor volume in the image sets of both treatments.Results: Important differences exist when defining ITVs with FI and IECT. Overall, differences larger than 5 mm were obtained for 49%, 31%, and 9.6% of the patients in Superior‐Inferior (SI), Anterior‐Posterior (AP), and Lateral (LAT) directions, respectively. For tumor location, larger differences were found for tumors in the liver (73.6% SI, 27.3% AP, and 6.7% in LAT had differences larger than 5 mm), while tumors in the upper lobe benefitted less using FI (differences larger than 5 mm were only present in 27.6% (SI), 36.7% (AP), and 0% (LAT) of the patients).Conclusions: Use of FI with the linac built‐in CBCT system is feasible for ITV definition. Large differences between motion amplitudes detected with FI and IECT methods were found. The method presented in this work based on FI could represent an improvement in ITV definition compared to the method based on IECT due to FI permits tumor motion acquisition in a more realistic situation than IECT.
- 1 March 2020
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 51 (1) , 88-94
Dosimetric and Contrast Noise Ratio Comparison of Three Different Digital Imaging Technologies in Mammography
- 1 March 2020
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 51 (1) , 88-94
Dosimetric and Contrast Noise Ratio Comparison of Three Different Digital Imaging Technologies in Mammography
- 1 August 2019
- Published by Wiley in Medical Physics
- Vol. 46 (10) , 4622-4630
On the use of Bayesian statistics in the application of adaptive setup protocols in radiotherapy
Purpose: To propose adaptive setup protocols using Bayesian statistics that facilitate, based on a prediction of coverage probability, making a decision on which patients should follow daily imaging prior to treatment delivery.Materials and Methods: The suitability of the treatment margins was assessed combining interfraction variability measurements of the first days of treatment with previous data gathered from our patient population. From this information, we decided if a patient needs an online imaging protocol to perform daily isocenter correction before each treatment fraction. We applied our method to five different datasets. Protocol parameters were selected from each dataset based on coverage probability, the expected imaging workload of the treatment unit, and the accuracy of patient classification. Time trends were assessed and included in the proposed protocols. To validate the accuracy of the protocols, they were applied to a validation dataset of prostate cancer patients.Results: Adaptive setup protocols lead expected population coverage >97% in all datasets analyzed when time trends were considered. The reduction in imaging workload ranged from 40% in lung treatments to 28.5% in prostate treatments. Results of the protocol on the validation dataset were very similar to those previously predicted.Conclusions: The adaptive setup protocols based on Bayesian statistics presented in this study enable the optimization of imaging workload in the treatment unit ensuring that appropriate dose coverage remains unchanged.
- 1 August 2019
- Published by Wiley in Medical Physics
- Vol. 46 (10) , 4622-4630
On the use of Bayesian statistics in the application of adaptive setup protocols in radiotherapy
Purpose: To propose adaptive setup protocols using Bayesian statistics that facilitate, based on a prediction of coverage probability, making a decision on which patients should follow daily imaging prior to treatment delivery.Materials and Methods: The suitability of the treatment margins was assessed combining interfraction variability measurements of the first days of treatment with previous data gathered from our patient population. From this information, we decided if a patient needs an online imaging protocol to perform daily isocenter correction before each treatment fraction. We applied our method to five different datasets. Protocol parameters were selected from each dataset based on coverage probability, the expected imaging workload of the treatment unit, and the accuracy of patient classification. Time trends were assessed and included in the proposed protocols. To validate the accuracy of the protocols, they were applied to a validation dataset of prostate cancer patients.Results: Adaptive setup protocols lead expected population coverage >97% in all datasets analyzed when time trends were considered. The reduction in imaging workload ranged from 40% in lung treatments to 28.5% in prostate treatments. Results of the protocol on the validation dataset were very similar to those previously predicted.Conclusions: The adaptive setup protocols based on Bayesian statistics presented in this study enable the optimization of imaging workload in the treatment unit ensuring that appropriate dose coverage remains unchanged.
- Open Access
- 1 April 2019
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 133, S1032-S1033
EP-1899 Prediction of outcomes in lung SBRT with dosimetric variables and machine learning techniques
- 1 April 2019
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 133, S1032-S1033
Open AccessEP-1899 Prediction of outcomes in lung SBRT with dosimetric variables and machine learning techniques