Mohamed Sharafeldin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed Sharafeldin has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- James F. Rusling
Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA
11 shared publications - Jason J. Davis
Department of Chemistry, University of Oxford, Oxford OX1 3QZ, UK
9 shared publications Norman H. Lee
Department of Pharmacology and Physiology, George Washington University, 2300 I Street, NW, Washington, Washington, D.C. 20037, United States
3 shared publicationsAbby L. Jones
Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, United States
2 shared publications- Islam M. Mosa
Department of Chemistry, Tanta University, Tanta 31527, Egypt
2 shared publications James F. Rusling
2 shared publications
Latest Publications
- 16 July 2025
- Published by Elsevier in Microchemical Journal
- Vol. 216
Ultrasensitive multiplexed detection of cancer biomarker proteins using SPR imaging
- 16 July 2025
- Published by Elsevier in Microchemical Journal
- Vol. 216
Ultrasensitive multiplexed detection of cancer biomarker proteins using SPR imaging
- Open Access
- 7 November 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1333, 343396
Microfluidic-based fluorescence enhancement of silica-embedded carbon dots for direct detection and quantification of unamplified HCV RNA in clinical samples
- 7 November 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1333, 343396
Open AccessMicrofluidic-based fluorescence enhancement of silica-embedded carbon dots for direct detection and quantification of unamplified HCV RNA in clinical samples
- Open Access
- 28 May 2024
- Published by MDPI AG in Proceedings
- Vol. 104 (1) , 1
Conductive Mesh Electrodes for Electrochemical Biosensors
- 28 May 2024
- Published by MDPI AG in Proceedings
- Vol. 104 (1) , 1
Open AccessConductive Mesh Electrodes for Electrochemical Biosensors
- Open Access
- 26 March 2024
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 3 (4) , 562-584
The integrated on-chip isolation and detection of circulating tumour cells
Accessible microfluidic configurations support CTC isolation (by size, rigidity, antigen expression) and detection in a single platform. Integrated detection can be achieved through optical, electrochemical, and physical means.
- 26 March 2024
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 3 (4) , 562-584
Open AccessThe integrated on-chip isolation and detection of circulating tumour cells
Accessible microfluidic configurations support CTC isolation (by size, rigidity, antigen expression) and detection in a single platform. Integrated detection can be achieved through optical, electrochemical, and physical means.
- Open Access
- 11 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (20) , 7906-7913
Alternating Magnetic Field-Promoted Nanoparticle Mixing: The On-Chip Immunocapture of Serum Neuronal Exosomes for Parkinson’s Disease Diagnostics
The analysis of cargo proteins in exosome subpopulations has considerable value in diagnostics but a translatable impact has been limited by lengthy or complex exosome extraction protocols. We describe herein a scalable, fast, and low-cost exosome extraction using an alternating (AC) magnetic field to support the dynamic mixing of antibody-coated magnetic beads (MBs) with serum samples within 3D-printed microfluidic chips. Zwitterionic polymer-coated MBs are, specifically, magnetically agitated and support ultraclean exosome capture efficiencies >70% from <50 μL of neat serum in 30 min. Applied herein to the immunocapture of neuronal exosomes using anti-L1CAM antibodies, prior to the array-based assaying of α-synuclein (α-syn) content by a standard duplex electrochemical sandwich ELISA, sub pg/mL detection was possible with an excellent coefficient of variation and a sample-to-answer time of ∼75 min. The high performance and semiautomation of this approach hold promise in underpinning low-cost Parkinson's disease diagnostics and is of value in exosomal biomarker analyses more generally.
- 11 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (20) , 7906-7913
Open AccessAlternating Magnetic Field-Promoted Nanoparticle Mixing: The On-Chip Immunocapture of Serum Neuronal Exosomes for Parkinson’s Disease Diagnostics
The analysis of cargo proteins in exosome subpopulations has considerable value in diagnostics but a translatable impact has been limited by lengthy or complex exosome extraction protocols. We describe herein a scalable, fast, and low-cost exosome extraction using an alternating (AC) magnetic field to support the dynamic mixing of antibody-coated magnetic beads (MBs) with serum samples within 3D-printed microfluidic chips. Zwitterionic polymer-coated MBs are, specifically, magnetically agitated and support ultraclean exosome capture efficiencies >70% from <50 μL of neat serum in 30 min. Applied herein to the immunocapture of neuronal exosomes using anti-L1CAM antibodies, prior to the array-based assaying of α-synuclein (α-syn) content by a standard duplex electrochemical sandwich ELISA, sub pg/mL detection was possible with an excellent coefficient of variation and a sample-to-answer time of ∼75 min. The high performance and semiautomation of this approach hold promise in underpinning low-cost Parkinson's disease diagnostics and is of value in exosomal biomarker analyses more generally.
- Open Access
- 1 March 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (10) , 4721-4727
Ultrafast Biomarker Quantification through Reagentless Capacitive Kinetics
We introduce a facile assessment of binding kinetics at bioreceptive redox-active interfaces as a means of quantifying target proteins. This is achieved by monitoring the redox capacitance (Cr) of a receptor-modified conductive polymer interface under continuous flow. Exemplified with the quantification of C-reactive protein (CRP), capacitance analyses resolve both the association and dissociation regimes in real-time. Significantly, the rate of electrochemical signal change within the association regime is a sensitive function of target concentration, enabling marker assaying down to picomolar levels, comparable to end-point assays, in 15 s. This reagentless proof-of-principle methodology is envisioned to be widely applicable to the facile quantification of a range of other pertinent, clinically relevant targets.
- 1 March 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (10) , 4721-4727
Open AccessUltrafast Biomarker Quantification through Reagentless Capacitive Kinetics
We introduce a facile assessment of binding kinetics at bioreceptive redox-active interfaces as a means of quantifying target proteins. This is achieved by monitoring the redox capacitance (Cr) of a receptor-modified conductive polymer interface under continuous flow. Exemplified with the quantification of C-reactive protein (CRP), capacitance analyses resolve both the association and dissociation regimes in real-time. Significantly, the rate of electrochemical signal change within the association regime is a sensitive function of target concentration, enabling marker assaying down to picomolar levels, comparable to end-point assays, in 15 s. This reagentless proof-of-principle methodology is envisioned to be widely applicable to the facile quantification of a range of other pertinent, clinically relevant targets.
- 27 February 2023
- Published by Elsevier in Current Opinion in Electrochemistry
- Vol. 39
Multiplexed electrochemical assays for clinical applications
- 27 February 2023
- Published by Elsevier in Current Opinion in Electrochemistry
- Vol. 39
Multiplexed electrochemical assays for clinical applications
- Open Access
- 9 August 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 58 (68) , 9472-9475
Catalysed amplification of faradaic shotgun tagging in ultrasensitive electrochemical immunoassays
We introduce a novel electrochemical protein quantitation based on the shotgun biotin tagging of proteins prior to their interfacial immunocapture and polymeric enzyme tagging. The highly amplified faradaic signals generated from a novel ferrocene-tyramine adduct enable fg mL−1 (attomolar) levels of detection and span cross a 5 orders of magnitude dynamic range. This work supports ultrasensitive protein marker detection in a single antibody immunoassay format.
- 9 August 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 58 (68) , 9472-9475
Open AccessCatalysed amplification of faradaic shotgun tagging in ultrasensitive electrochemical immunoassays
We introduce a novel electrochemical protein quantitation based on the shotgun biotin tagging of proteins prior to their interfacial immunocapture and polymeric enzyme tagging. The highly amplified faradaic signals generated from a novel ferrocene-tyramine adduct enable fg mL−1 (attomolar) levels of detection and span cross a 5 orders of magnitude dynamic range. This work supports ultrasensitive protein marker detection in a single antibody immunoassay format.
- Open Access
- 25 March 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1216, 339759
Characterising the biosensing interface
- 25 March 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1216, 339759
Open AccessCharacterising the biosensing interface
- Open Access
- 27 January 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (5) , 2375-2382
A Quantification of Target Protein Biomarkers in Complex Media by Faradaic Shotgun Tagging
The progressive emergence of protein biomarkers promises a revolution in the healthcare industry and a shift of focus from disease management to much earlier intervention. Here, we introduce a facile shotgun tagging of ensemble proteins in clinically relevant media prior to specific target capture at antibody-modified electrodes. This facilitates a convenient voltammetric quantification of markers down to sub-pg/mL levels and across several orders of concentration. A translation of the methodology to an automated microfluidic platform enables marker quantification from 25 μL of sample in less than 15 min, demonstrated here with a simultaneous assaying of CRP and cardiac troponin I (cTnI). The assays show a good correlation with a standard immunoassay when applied to real patient serum samples. The platform is simple, generic, highly sensitive and requires no secondary labeling/binding or amplification.
- 27 January 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (5) , 2375-2382
Open AccessA Quantification of Target Protein Biomarkers in Complex Media by Faradaic Shotgun Tagging
The progressive emergence of protein biomarkers promises a revolution in the healthcare industry and a shift of focus from disease management to much earlier intervention. Here, we introduce a facile shotgun tagging of ensemble proteins in clinically relevant media prior to specific target capture at antibody-modified electrodes. This facilitates a convenient voltammetric quantification of markers down to sub-pg/mL levels and across several orders of concentration. A translation of the methodology to an automated microfluidic platform enables marker quantification from 25 μL of sample in less than 15 min, demonstrated here with a simultaneous assaying of CRP and cardiac troponin I (cTnI). The assays show a good correlation with a standard immunoassay when applied to real patient serum samples. The platform is simple, generic, highly sensitive and requires no secondary labeling/binding or amplification.