Reed Ayers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Reed Ayers has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Evalina Burger
University of Colorado, Anschutz. Department of Orthopedics, Academic Office One, 12631 East 17th Avenue 4602, Aurora, Colorado, 80045
5 shared publicationsVikas Patel
University of Colorado, Anschutz. Department of Orthopedics, Academic Office One, 12631 East 17th Avenue 4602, Aurora, Colorado, 80045
5 shared publicationsChristopher Kleck
University of Colorado, Anschutz. Department of Orthopedics, Academic Office One, 12631 East 17th Avenue 4602, Aurora, Colorado, 80045
3 shared publicationsDavid Ou-Yang
University of Colorado, Anschutz. Department of Orthopedics, Academic Office One, 12631 East 17th Avenue 4602, Aurora, Colorado, 80045
3 shared publications- Cheryl L. Ackert-Bicknell
Colorado Program for Musculoskeletal Research, Department of Orthopedics, University of Colorado School of Medicine, Aurora, CO
2 shared publications Christopher J. Kleck
2 shared publications
Latest Publications
- Open Access
Microbial Influenced Corrosion: A Novel Initiator of In Vivo Spine Rod Fracture
Spine rod catastrophic failure/rod fracture after implantation is estimated to occur in ∼10% of all cases worldwide with this rate remaining consistent for more than 20 years. To accommodate the spine mechanical environment, metal alloys such as austenitic stainless steels, cobalt–chromium–molybdenum alloys, and α/β type titanium alloys such are used as they have a high resistance to fatigue failure. The work presented herein addresses the gap in understanding about what happens in a laboratory environment versus what is happening in human patients that results in metal leaching into tissues as well as a shortened lifespan of a spine rod in a patient population that is not capable of breaking these spine rods from purely mechanical means. Eighty-five (N=85) patients (51 female – 62.9 ± 13.5 years old, 34 male - 62.7 ± 10.9 years old) who had spine revision surgery due to patient mechanical issues, such as loss of sagittal or coronal balance, pain, pedicle screw loosening, hardware associated infection were included in this study. All explanted rods had optical indications of surface modification that were not the result of mechanical damage, e.g. gouges, scratches, notches. The presence of Ti6Al4V rods increases the presence of local tissue concentrations of elemental Ti (190.98 ± 207.84 μg/g (ppm)) in all patients over the amount that would normally be present in patients who never had any titanium based orthopedic device implants (spinous muscle, 13.12 ± 11.43 μg/g). PQS, HHQ, and NHQ ToF-SIMS molecular signals were found co-located to corrosion pits as well with AHLs and palmitic acids indicating microbial presence and metabolism in all patients. This suggests that MIC can cause in vivo pitting corrosion resulting on rod failure.
Open AccessMicrobial Influenced Corrosion: A Novel Initiator of In Vivo Spine Rod Fracture
Spine rod catastrophic failure/rod fracture after implantation is estimated to occur in ∼10% of all cases worldwide with this rate remaining consistent for more than 20 years. To accommodate the spine mechanical environment, metal alloys such as austenitic stainless steels, cobalt–chromium–molybdenum alloys, and α/β type titanium alloys such are used as they have a high resistance to fatigue failure. The work presented herein addresses the gap in understanding about what happens in a laboratory environment versus what is happening in human patients that results in metal leaching into tissues as well as a shortened lifespan of a spine rod in a patient population that is not capable of breaking these spine rods from purely mechanical means. Eighty-five (N=85) patients (51 female – 62.9 ± 13.5 years old, 34 male - 62.7 ± 10.9 years old) who had spine revision surgery due to patient mechanical issues, such as loss of sagittal or coronal balance, pain, pedicle screw loosening, hardware associated infection were included in this study. All explanted rods had optical indications of surface modification that were not the result of mechanical damage, e.g. gouges, scratches, notches. The presence of Ti6Al4V rods increases the presence of local tissue concentrations of elemental Ti (190.98 ± 207.84 μg/g (ppm)) in all patients over the amount that would normally be present in patients who never had any titanium based orthopedic device implants (spinous muscle, 13.12 ± 11.43 μg/g). PQS, HHQ, and NHQ ToF-SIMS molecular signals were found co-located to corrosion pits as well with AHLs and palmitic acids indicating microbial presence and metabolism in all patients. This suggests that MIC can cause in vivo pitting corrosion resulting on rod failure.
- 12 June 2025
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 81  (7) , 707-713
Structured Light Three-Dimensional Scanning Enables Quantification of Surface Corrosion on Retrieved Spine Rods from Revision Patients
Corrosion of titanium-based metals inside the human body has long been considered a potential health risk. There is an ever-increasing number of spine surgeries performed around the world, and a notable 9% to 45% reported reoperation rate due to spine implant (instrumentation) failure. Instrumentation failure in medicine is not a catastrophic breakage. It is when a patient can no longer biologically or physiologically tolerate the implant; thus, the instrumentation has failed in its function. Most spine reoperations (revisions) are due to a continued progression of spine degeneration or other conditions not associated with infection or breakage. This situation allows the study of how orthopedic implant alloys fare in the human body beyond mechanical failures. Optical inspection is a proven method for area quantification of metallic surface corrosion and wear. Spine instrumentation was retrieved during spine revision procedures under an institution-approved research protocol. Patients who never had any metal implants (n = 6) had an adjacent average Ti tissue concentration of 13.12 μg/g, while patients who had instrumentation (n = 20) had a significantly higher average Ti concentration of 113.73 μg/g. On a per-patient basis (n = 33), the average surface area corrosion was 45.14% while the overall average surface area wear was 6.00%. The presence of a clinically diagnosed infection had a slight but insignificant effect on the overall area of corrosion measured with an increase of corrosion of 38.54% for patients with a clinically diagnosed infection compared to 36.96% for patients with no diagnosed infection. While the 3D scanning with colometric measurements used herein cannot quantify pitting corrosion volume, when combined with gravimetric methods, it may yield a more robust understanding of human in vivo mechanisms of spine rod degradation. The presence of corrosion on all rods in comparison to in vitro studies showing minimal corrosion suggests that our understanding of the human in vivo corrosion environment is still extremely limited.
- 12 June 2025
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 81  (7) , 707-713
Structured Light Three-Dimensional Scanning Enables Quantification of Surface Corrosion on Retrieved Spine Rods from Revision Patients
Corrosion of titanium-based metals inside the human body has long been considered a potential health risk. There is an ever-increasing number of spine surgeries performed around the world, and a notable 9% to 45% reported reoperation rate due to spine implant (instrumentation) failure. Instrumentation failure in medicine is not a catastrophic breakage. It is when a patient can no longer biologically or physiologically tolerate the implant; thus, the instrumentation has failed in its function. Most spine reoperations (revisions) are due to a continued progression of spine degeneration or other conditions not associated with infection or breakage. This situation allows the study of how orthopedic implant alloys fare in the human body beyond mechanical failures. Optical inspection is a proven method for area quantification of metallic surface corrosion and wear. Spine instrumentation was retrieved during spine revision procedures under an institution-approved research protocol. Patients who never had any metal implants (n = 6) had an adjacent average Ti tissue concentration of 13.12 μg/g, while patients who had instrumentation (n = 20) had a significantly higher average Ti concentration of 113.73 μg/g. On a per-patient basis (n = 33), the average surface area corrosion was 45.14% while the overall average surface area wear was 6.00%. The presence of a clinically diagnosed infection had a slight but insignificant effect on the overall area of corrosion measured with an increase of corrosion of 38.54% for patients with a clinically diagnosed infection compared to 36.96% for patients with no diagnosed infection. While the 3D scanning with colometric measurements used herein cannot quantify pitting corrosion volume, when combined with gravimetric methods, it may yield a more robust understanding of human in vivo mechanisms of spine rod degradation. The presence of corrosion on all rods in comparison to in vitro studies showing minimal corrosion suggests that our understanding of the human in vivo corrosion environment is still extremely limited.
- 26 October 2021
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 30  (2) , e252-e263
Laser Marking of Spine Rods Is Strongly Associated With Risk of Clinical Rod Failure
Introduction: What is overlooked in clinical studies are the possibilities of manufacturing and design aspects of the instrumentation that could initiate rod fracture. Although revision because of hardware fracture is a small fraction of the overall revision rates (12.1% to 13.7%), there are sufficient numbers of revision cases where hardware removed can undergo a thorough metallurgic analysis. This study is unique in that rod characteristics, such as alloy, surface markings, and fracture type, seen at fracture surfaces are considered in the analysis. Methods: This work was conducted under both a retrospective and prospective IRB. Patients considered for this study were between the ages of 18 and 85 years who underwent or were undergoing revision spine surgery with previous instrumentation in the cervical, thoracic, or lumbar region and evidence of at least one of the following: catastrophic hardware failure, pseudarthrosis, implant loosening, or nonfusion. Inclusion criteria were determined through radiographic and medical records review. Results: Fifty-six patients who had revision procedures because of different indications were included; 101 rods were removed, tested for fracture, and included in the analysis. Laser marking is significantly (P < 0.0001) associated with rod fracture. Detailed analysis showed notable surface and subsurface changes as the result of the marking, such as surface melting, cracking, and notching, creating locations to initiate a fracture. The three most informative variables to clinical rod fracture using multiple regression modeling were body mass index, presence or absence of laser mark (yes/no), and length of posterior fusion (≤2 spinal levels/>2 spinal levels). It was found that the relative risk of rod fracture is 23 times higher during 20 postoperative years than in cases with this index <0.4. Discussion: For a patient with a given body mass index, if they require a multilevel fixation greater than two levels and rods with laser marks are used, the risk of early rod fracture increases by 40%.
- 26 October 2021
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 30  (2) , e252-e263
Laser Marking of Spine Rods Is Strongly Associated With Risk of Clinical Rod Failure
Introduction: What is overlooked in clinical studies are the possibilities of manufacturing and design aspects of the instrumentation that could initiate rod fracture. Although revision because of hardware fracture is a small fraction of the overall revision rates (12.1% to 13.7%), there are sufficient numbers of revision cases where hardware removed can undergo a thorough metallurgic analysis. This study is unique in that rod characteristics, such as alloy, surface markings, and fracture type, seen at fracture surfaces are considered in the analysis. Methods: This work was conducted under both a retrospective and prospective IRB. Patients considered for this study were between the ages of 18 and 85 years who underwent or were undergoing revision spine surgery with previous instrumentation in the cervical, thoracic, or lumbar region and evidence of at least one of the following: catastrophic hardware failure, pseudarthrosis, implant loosening, or nonfusion. Inclusion criteria were determined through radiographic and medical records review. Results: Fifty-six patients who had revision procedures because of different indications were included; 101 rods were removed, tested for fracture, and included in the analysis. Laser marking is significantly (P < 0.0001) associated with rod fracture. Detailed analysis showed notable surface and subsurface changes as the result of the marking, such as surface melting, cracking, and notching, creating locations to initiate a fracture. The three most informative variables to clinical rod fracture using multiple regression modeling were body mass index, presence or absence of laser mark (yes/no), and length of posterior fusion (≤2 spinal levels/>2 spinal levels). It was found that the relative risk of rod fracture is 23 times higher during 20 postoperative years than in cases with this index <0.4. Discussion: For a patient with a given body mass index, if they require a multilevel fixation greater than two levels and rods with laser marks are used, the risk of early rod fracture increases by 40%.
- 1 January 2020
- Published by SLACK, Inc. in Orthopedics
- Vol. 43  (1) , 62-67
Corrosion of Titanium Spinal Explants Is Similar to That Observed in Oil Field Line Pipe Steel: Evidence of Microbial-Influenced Corrosion In Vivo
Current explanations of biomedical alloy degradation are focused on the physicochemical mechanisms of galvanic, pitting, crevice, and fretting corrosion. Ultimately, these studies dismiss the corrosion mechanism as a function of the local microbiome. Sixty spine hardware constructs were examined immediately after explantation for biofilm formation. Marked rod sections were imaged using scanning electron microscopy with energy dispersive x-ray spectroscopy. Backscatter mode was employed to better image the topology of the surface. There is clear differentiation between discoloration due to corrosion vs mechanical damage. Under scanning electron microscopy backscatter electron shadow examination, the authors noted that not all biofilm was removed using the surgical wipes. Corrosion pits were noticeably larger and numerous in areas of biofilm. In areas not associated with biofilms, there were few pits even if mechanical wear was evident. There is no evidence that the surface corrosion is modified between clinically diagnosed infected and noninfected patients. The surface damage present on explanted Ti6Al4V spine rods is uniquely similar to damage found in other industries where microbial-influenced corrosion is prevalent. Given that similar anaerobic, sulfur-reducing bacteria reside in and on human tissues, it is most likely that corrosion observed on explanted hardware is the result of microbial-influenced corrosion and not from inflammatory or other processes. Using analysis methods from other industries to characterize the microbiome present on explanted hardware is necessary. In so doing, a new definition of hardware-induced infection will be forthcoming. [ Orthopedics . 2020;43(1):62–67.]
- 1 January 2020
- Published by SLACK, Inc. in Orthopedics
- Vol. 43  (1) , 62-67
Corrosion of Titanium Spinal Explants Is Similar to That Observed in Oil Field Line Pipe Steel: Evidence of Microbial-Influenced Corrosion In Vivo
Current explanations of biomedical alloy degradation are focused on the physicochemical mechanisms of galvanic, pitting, crevice, and fretting corrosion. Ultimately, these studies dismiss the corrosion mechanism as a function of the local microbiome. Sixty spine hardware constructs were examined immediately after explantation for biofilm formation. Marked rod sections were imaged using scanning electron microscopy with energy dispersive x-ray spectroscopy. Backscatter mode was employed to better image the topology of the surface. There is clear differentiation between discoloration due to corrosion vs mechanical damage. Under scanning electron microscopy backscatter electron shadow examination, the authors noted that not all biofilm was removed using the surgical wipes. Corrosion pits were noticeably larger and numerous in areas of biofilm. In areas not associated with biofilms, there were few pits even if mechanical wear was evident. There is no evidence that the surface corrosion is modified between clinically diagnosed infected and noninfected patients. The surface damage present on explanted Ti6Al4V spine rods is uniquely similar to damage found in other industries where microbial-influenced corrosion is prevalent. Given that similar anaerobic, sulfur-reducing bacteria reside in and on human tissues, it is most likely that corrosion observed on explanted hardware is the result of microbial-influenced corrosion and not from inflammatory or other processes. Using analysis methods from other industries to characterize the microbiome present on explanted hardware is necessary. In so doing, a new definition of hardware-induced infection will be forthcoming. [ Orthopedics . 2020;43(1):62–67.]
- 1 December 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 29  (1) , 3
Three cases of metallosis associated with spine instrumentation
The characteristic trait of metallosis is the presence of tissue staining. Analyzing explanted revision hardware from spine surgeries and performing ICPMS/AES analysis on removed tissue samples, a clinically relevant definition for metallosis may be developed. Results of the analysis identified hardware fretting wear and corrosion, and ICP-MS/AES analysis identified elevated metal ion concentrations in all cases. This supports the hypothesis that corrosion may be linked to poor health outcomes and potential need for revision surgery. Using failure analysis methods, corrosion products from orthopedic spine implants can be identified to begin to characterize metallosis in a clinically relevant manner. Failure analysis for patients undergoing revision spine surgery for other causes. Using failure analysis methods we conducted a retrieval analysis of explanted hardware and tissue. Implant failure with surrounding tissue metal staining is a current issue in the field of orthopedics. Specifically in spine, this issue is under reported and over looked as a clinically significant finding. Metallosis is most commonly used to describe the presence of tissue staining however this is not a clinically relevant definition. There is a need for further research to provide a better understanding of metallosis leading to better patient outcomes. Patients were screened for this study during a radiological review prior to surgery. All explanted hardware was documented and inspected for signs of wear and corrosion using non-destructive testing. A tissue sample that is normally removed and discarded was collected for ICP-MS/AES analysis. The presence of fretting corrosion, galling and corrosion fatigue was found on all explanted hardware. Cr levels are significantly higher than what was previously published as normal in muscle 0.03 μg/g. One case was a 4 order of magnitude elevation with the other 2 approximately 2 orders of magnitude increase. Titanium and Co concentrations are also significantly increased. The Ca to P ratio for all samples is approximately 1.7:1 suggesting some form of apatitic crystal present due to drying of the tissues. In all cases, the Al, Mo, V, Co, content in surrounding tissue is significantly elevated >10Ă— above "normal," 8.4 ± 4.8; 1.61 ± 1.41; 0.06 ± 0.03; 1.35 ± 1.97 μg/g respectively. A "normal" reference titanium level could only be found for whole blood, 0.00072 ± 0.1412 μ/g. Iron and Ni measurements are within typical values presented in previous studies. No single mechanism for the release of metal ion in a patient is clear. Evidence suggests a tribocorrosive process due to both wear and environmental factors. Specific biologic mechanisms, such as the possible presence of bacteria may affect the fretting and corrosion of spinal instrumentation must be explored in conjunction with thorough review of patient outcomes. Such an effort can potentially reduce patient readmission and increase successful patient outcomes.
- 1 December 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 29  (1) , 3
Three cases of metallosis associated with spine instrumentation
The characteristic trait of metallosis is the presence of tissue staining. Analyzing explanted revision hardware from spine surgeries and performing ICPMS/AES analysis on removed tissue samples, a clinically relevant definition for metallosis may be developed. Results of the analysis identified hardware fretting wear and corrosion, and ICP-MS/AES analysis identified elevated metal ion concentrations in all cases. This supports the hypothesis that corrosion may be linked to poor health outcomes and potential need for revision surgery. Using failure analysis methods, corrosion products from orthopedic spine implants can be identified to begin to characterize metallosis in a clinically relevant manner. Failure analysis for patients undergoing revision spine surgery for other causes. Using failure analysis methods we conducted a retrieval analysis of explanted hardware and tissue. Implant failure with surrounding tissue metal staining is a current issue in the field of orthopedics. Specifically in spine, this issue is under reported and over looked as a clinically significant finding. Metallosis is most commonly used to describe the presence of tissue staining however this is not a clinically relevant definition. There is a need for further research to provide a better understanding of metallosis leading to better patient outcomes. Patients were screened for this study during a radiological review prior to surgery. All explanted hardware was documented and inspected for signs of wear and corrosion using non-destructive testing. A tissue sample that is normally removed and discarded was collected for ICP-MS/AES analysis. The presence of fretting corrosion, galling and corrosion fatigue was found on all explanted hardware. Cr levels are significantly higher than what was previously published as normal in muscle 0.03 μg/g. One case was a 4 order of magnitude elevation with the other 2 approximately 2 orders of magnitude increase. Titanium and Co concentrations are also significantly increased. The Ca to P ratio for all samples is approximately 1.7:1 suggesting some form of apatitic crystal present due to drying of the tissues. In all cases, the Al, Mo, V, Co, content in surrounding tissue is significantly elevated >10Ă— above "normal," 8.4 ± 4.8; 1.61 ± 1.41; 0.06 ± 0.03; 1.35 ± 1.97 μg/g respectively. A "normal" reference titanium level could only be found for whole blood, 0.00072 ± 0.1412 μ/g. Iron and Ni measurements are within typical values presented in previous studies. No single mechanism for the release of metal ion in a patient is clear. Evidence suggests a tribocorrosive process due to both wear and environmental factors. Specific biologic mechanisms, such as the possible presence of bacteria may affect the fretting and corrosion of spinal instrumentation must be explored in conjunction with thorough review of patient outcomes. Such an effort can potentially reduce patient readmission and increase successful patient outcomes.
- 11 July 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28  (8) , 1-7
Spine rod straightening as a possible cause for revision
In a previous study, the authors examined the elastic and short-term anelastic springback of Ti6Al4V, CoCrMoC and A316L stainless steel spine rods to observe how the rods mechanically respond in OR contouring. In that study rods were 200 mm long and only the movement at the tip was recorded. The implication of that work was that rods will straighten in-vivo, however, in order for the mechanism of straightening to be determined, the movement of individual bends over time must first be elucidated. Spine rods used were, commercially pure titanium (CP Ti) a primarily α-phase; Ti-6Al-4V; α/β-phase titanium alloy from two different suppliers (denoted by, Ti-6Al-4V (L) and Ti-6Al-4V); β-phase titanium (TNTZ) and CoCrMoC. Following contouring the rods were aged unconstrained, in normal atmosphere or simulated body fluid (SBF) in a CO2 incubator for up to 288 h. Elastic springback is significantly different between alloys with different microstructures. Both types of Ti6Al4V rods, while meeting the ASTM F136 industry standard, have significantly different properties, most importantly yield strength, flexural modulus, and springback. Environment showed no significant impact on anelasticity. The anelastic response of Ti6Al4V L sample, which has relatively more beta phase than the Ti6Al4V sample, follows the pure beta phase TNTZ in its extended time response. CoCrMoC and CP Ti have a very reduced anelastic response compared to the other alloys. This potentially can have unanticipated effects on the outcome of spine procedures, as the surgeon is reliant on the rods having similar properties to achieve a desired outcome.
- 11 July 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28  (8) , 1-7
Spine rod straightening as a possible cause for revision
In a previous study, the authors examined the elastic and short-term anelastic springback of Ti6Al4V, CoCrMoC and A316L stainless steel spine rods to observe how the rods mechanically respond in OR contouring. In that study rods were 200 mm long and only the movement at the tip was recorded. The implication of that work was that rods will straighten in-vivo, however, in order for the mechanism of straightening to be determined, the movement of individual bends over time must first be elucidated. Spine rods used were, commercially pure titanium (CP Ti) a primarily α-phase; Ti-6Al-4V; α/β-phase titanium alloy from two different suppliers (denoted by, Ti-6Al-4V (L) and Ti-6Al-4V); β-phase titanium (TNTZ) and CoCrMoC. Following contouring the rods were aged unconstrained, in normal atmosphere or simulated body fluid (SBF) in a CO2 incubator for up to 288 h. Elastic springback is significantly different between alloys with different microstructures. Both types of Ti6Al4V rods, while meeting the ASTM F136 industry standard, have significantly different properties, most importantly yield strength, flexural modulus, and springback. Environment showed no significant impact on anelasticity. The anelastic response of Ti6Al4V L sample, which has relatively more beta phase than the Ti6Al4V sample, follows the pure beta phase TNTZ in its extended time response. CoCrMoC and CP Ti have a very reduced anelastic response compared to the other alloys. This potentially can have unanticipated effects on the outcome of spine procedures, as the surgeon is reliant on the rods having similar properties to achieve a desired outcome.
- 19 April 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 27  (6) , 1-12
Antimicrobial activity and biologic potential of silver-substituted calcium phosphate constructs produced with self-propagating high-temperature synthesis
There is significant demand for synthetic bone substitute materials that can decrease the incidence of implant-based bacterial infections. The intent of this research was to evaluate the antimicrobial activity and biologic potential of calcium phosphate (CaP) constructs substituted with silver (Ag) that were produced via self-propagating high-temperature synthesis (SHS). SHS is a combustion synthesis technique that has successfully generated porous CaP bioceramics intended for use in bone repair. SHS reactions are highly versatile; dopants can be added to the reactant powders to alter product chemistry and morphology. In this research, Ag powder was added to the reactants generating porous CaP constructs containing 0.5, 1, or 2 wt% Ag. Antibacterial performance of the constructs was assessed against Escherichia coli, a representative model for Gram-negative bacteria. Liquid solutions (1 μg/mL) of CaP–Ag particles to phosphate buffered saline were incubated with 105 cells/mL. After 24 h, 10 μL of solution were spread on an LB agar plate and cultured for 24 h at 37 °C. Samples cultured with CaP–Ag showed complete bacterial inhibition while the controls (E. coli only and CaP without Ag) exhibited significant colony formation. The effects of Ag concentration on cytotoxicity and biocompatibility were tested in vitro. At 7 days, osteoblasts uniformly enveloped the CaP–Ag particles and displayed a healthy flattened morphology suggesting the concentrations of Ag incorporated into constructs were not cytotoxic. CaP–Ag constructs produced via SHS represent a source of synthetic bone substitute materials that could potentially inhibit, or reduce the incidence of post-operative bacterial infections.
- 19 April 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 27  (6) , 1-12
Antimicrobial activity and biologic potential of silver-substituted calcium phosphate constructs produced with self-propagating high-temperature synthesis
There is significant demand for synthetic bone substitute materials that can decrease the incidence of implant-based bacterial infections. The intent of this research was to evaluate the antimicrobial activity and biologic potential of calcium phosphate (CaP) constructs substituted with silver (Ag) that were produced via self-propagating high-temperature synthesis (SHS). SHS is a combustion synthesis technique that has successfully generated porous CaP bioceramics intended for use in bone repair. SHS reactions are highly versatile; dopants can be added to the reactant powders to alter product chemistry and morphology. In this research, Ag powder was added to the reactants generating porous CaP constructs containing 0.5, 1, or 2 wt% Ag. Antibacterial performance of the constructs was assessed against Escherichia coli, a representative model for Gram-negative bacteria. Liquid solutions (1 μg/mL) of CaP–Ag particles to phosphate buffered saline were incubated with 105 cells/mL. After 24 h, 10 μL of solution were spread on an LB agar plate and cultured for 24 h at 37 °C. Samples cultured with CaP–Ag showed complete bacterial inhibition while the controls (E. coli only and CaP without Ag) exhibited significant colony formation. The effects of Ag concentration on cytotoxicity and biocompatibility were tested in vitro. At 7 days, osteoblasts uniformly enveloped the CaP–Ag particles and displayed a healthy flattened morphology suggesting the concentrations of Ag incorporated into constructs were not cytotoxic. CaP–Ag constructs produced via SHS represent a source of synthetic bone substitute materials that could potentially inhibit, or reduce the incidence of post-operative bacterial infections.
- 1 July 2015
- Published by Elsevier in Ceramics International
- Vol. 41  (6) , 7735-7744
Biologic potential of calcium phosphate biopowders produced via decomposition combustion synthesis
- 1 July 2015
- Published by Elsevier in Ceramics International
- Vol. 41  (6) , 7735-7744
Biologic potential of calcium phosphate biopowders produced via decomposition combustion synthesis
- 1 January 2003
- Published by Springer Nature in MRS Proceedings
- Vol. 800
Combustion Synthesis of NiTi – TiC Composites with Controlled Porosity for Biomedical Applications
- 1 January 2003
- Published by Springer Nature in MRS Proceedings
- Vol. 800
Combustion Synthesis of NiTi – TiC Composites with Controlled Porosity for Biomedical Applications