Jiaru Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaru Shi has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
Huaibi Chen
Tsinghua University
28 shared publicationsHao Zha
Tsinghua University
26 shared publications- Xian-Cai Lin
Tsinghua University
9 shared publications Chuanxiang Tang
Department of Engineering Physics, Tsinghua University, Beijing, China
8 shared publications- Hao Zha
Department of Engineering Physics, Tsinghua University, Beijing, China
8 shared publications Huai-Bi Chen
Department of Engineering Physics, Tsinghua University, Beijing, China
8 shared publications
Latest Publications
- 18 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9) , 189
Design, fabrication, and test of an S-band multi-beam accelerating structure for industrial stationary CT application
- 18 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9) , 189
Design, fabrication, and test of an S-band multi-beam accelerating structure for industrial stationary CT application
- Open Access
- 1 July 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (8)
Novel scheme of beam loading compensation for a traveling wave acceleration structure with microwave pulse compression
In order to reduce the increase in bunch energy dispersion caused by the beam loading effect, beam loading compensation in the acceleration structure is required. In this paper, a novel scheme is proposed to use microwave pulse compression to compensate for the beam loading effect in the traveling wave structure. The compression system consists of an energy storage cavity and a correction chain of six cavities working in S band. Through parameter optimization, the optimal coupling factors of the energy storage cavity and the correction cavity are obtained to generate microwave pulses with increasing amplitude. Through this scheme, the S-band traveling wave acceleration structure achieves an acceleration voltage of 50.14 MV with a power input of 16.6 MW and a beam current of 2.5 A. The relative energy dispersion is 0.77%, and the effective system power gain reaches 10.56, significantly surpassing that of conventional microwave pulse compression systems.
- 1 July 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (8)
Open AccessNovel scheme of beam loading compensation for a traveling wave acceleration structure with microwave pulse compression
In order to reduce the increase in bunch energy dispersion caused by the beam loading effect, beam loading compensation in the acceleration structure is required. In this paper, a novel scheme is proposed to use microwave pulse compression to compensate for the beam loading effect in the traveling wave structure. The compression system consists of an energy storage cavity and a correction chain of six cavities working in S band. Through parameter optimization, the optimal coupling factors of the energy storage cavity and the correction cavity are obtained to generate microwave pulses with increasing amplitude. Through this scheme, the S-band traveling wave acceleration structure achieves an acceleration voltage of 50.14 MV with a power input of 16.6 MW and a beam current of 2.5 A. The relative energy dispersion is 0.77%, and the effective system power gain reaches 10.56, significantly surpassing that of conventional microwave pulse compression systems.
- Open Access
- 29 May 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (5)
High-power performance and analysis of six X-band high-gradient accelerating structures
Six X-band accelerating structures with identical radio frequency (rf) designs have been developed and fabricated for the Very Compact Inverse Compton Scattering Gamma-Ray Source (VIGAS) project at Tsinghua University, representing the first large-scale deployment of such devices with consistent rf performance in China. This article presents the tuning, conditioning, and high-power performance results of these structures, with emphasis on in-depth analysis of conditioning processes and rf breakdown phenomena. The six structures achieved an accelerating gradient of 80 MV / m with a breakdown rate of no more than 1 × 10 − 4 per pulse after systematic conditioning. Our study reveals several critical aspects of rf breakdown behavior in X-band high-gradient accelerating structures. Key observations include the localization of breakdown events in regions of high electric field, particularly in cells adjacent to the input coupler; a power-law dependence of the normalized breakdown rate on cumulative pulse count, with notable variation in fitting parameters across different structures; and a two-exponential statistical distribution characterizing breakdown intervals. These findings offer important implications for optimizing conditioning strategies for high-gradient rf structures. Furthermore, the analysis of performance variations among nominally identical structures uncovers underlying physical mechanisms governing breakdown, establishing a useful benchmark for the development of future compact accelerator facilities.
- 29 May 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (5)
Open AccessHigh-power performance and analysis of six X-band high-gradient accelerating structures
Six X-band accelerating structures with identical radio frequency (rf) designs have been developed and fabricated for the Very Compact Inverse Compton Scattering Gamma-Ray Source (VIGAS) project at Tsinghua University, representing the first large-scale deployment of such devices with consistent rf performance in China. This article presents the tuning, conditioning, and high-power performance results of these structures, with emphasis on in-depth analysis of conditioning processes and rf breakdown phenomena. The six structures achieved an accelerating gradient of 80 MV / m with a breakdown rate of no more than 1 × 10 − 4 per pulse after systematic conditioning. Our study reveals several critical aspects of rf breakdown behavior in X-band high-gradient accelerating structures. Key observations include the localization of breakdown events in regions of high electric field, particularly in cells adjacent to the input coupler; a power-law dependence of the normalized breakdown rate on cumulative pulse count, with notable variation in fitting parameters across different structures; and a two-exponential statistical distribution characterizing breakdown intervals. These findings offer important implications for optimizing conditioning strategies for high-gradient rf structures. Furthermore, the analysis of performance variations among nominally identical structures uncovers underlying physical mechanisms governing breakdown, establishing a useful benchmark for the development of future compact accelerator facilities.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04042
A 10 MeV 40 kW S-band backward-traveling-wave linac for electron irradiation
Aiming at the urgent demand for high-average-power, high-stability and low-energy-consumption electron irradiation accelerators in the industrial field, a 10 MeV 40 kW S-band (2856 MHz) constant-gradient backward-travelling-wave (BTW) linear accelerator (linac) was developed in this study. The BTW accelerating structure combines the advantages of travelling-wave (TW) and standing-wave (SW) structures, adopting magnetic coupling between cells and nosecone cavity design to achieve high shunt impedance, low power reflection and short filling time. A constant-gradient tapered design was introduced, which effectively improved the beam acceleration efficiency and power capacity. A comprehensive multi-physics simulation was carried out to optimize the thermal management of the structure, and the coupling disk was redesigned to solve the problem of heat dissipation. The prototype was fabricated by high-precision machining and vacuum brazing, and the low-power cold test was completed by the bead-pull method, which realized the accurate tuning of the electric field distribution and phase advance. High-power testing validates electron acceleration to 10 MeV with a peak pulse current of more than 300 mA, average current of 3.8 mA, and average output power of 40 kW. This BTW linac addresses key gaps in industrial and medical irradiation, offering a high-performance, reliable solution. This paper elaborates on RF design, multiphysics simulations, fabrication, tuning, high-power testing, and summarizes key findings.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04042
A 10 MeV 40 kW S-band backward-traveling-wave linac for electron irradiation
Aiming at the urgent demand for high-average-power, high-stability and low-energy-consumption electron irradiation accelerators in the industrial field, a 10 MeV 40 kW S-band (2856 MHz) constant-gradient backward-travelling-wave (BTW) linear accelerator (linac) was developed in this study. The BTW accelerating structure combines the advantages of travelling-wave (TW) and standing-wave (SW) structures, adopting magnetic coupling between cells and nosecone cavity design to achieve high shunt impedance, low power reflection and short filling time. A constant-gradient tapered design was introduced, which effectively improved the beam acceleration efficiency and power capacity. A comprehensive multi-physics simulation was carried out to optimize the thermal management of the structure, and the coupling disk was redesigned to solve the problem of heat dissipation. The prototype was fabricated by high-precision machining and vacuum brazing, and the low-power cold test was completed by the bead-pull method, which realized the accurate tuning of the electric field distribution and phase advance. High-power testing validates electron acceleration to 10 MeV with a peak pulse current of more than 300 mA, average current of 3.8 mA, and average output power of 40 kW. This BTW linac addresses key gaps in industrial and medical irradiation, offering a high-performance, reliable solution. This paper elaborates on RF design, multiphysics simulations, fabrication, tuning, high-power testing, and summarizes key findings.
- 11 August 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 234 (27) , 8125-8136
X-band high-gradient main linear accelerator for compact inverse-compton light source
- 11 August 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 234 (27) , 8125-8136
X-band high-gradient main linear accelerator for compact inverse-compton light source
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (10) , 7665-7678
A Rapid Microwave Distribution Network for Accelerator Array System
This work presents a rapid microwave distribution network based on a compact multiplexer component, to cooperate with an accelerator array system for rapid multiangle radiation. Given the current limitation of high-power klystrons in output bandwidth, this distribution network achieves output branch switching with narrow frequency intervals, while maintaining high transmission efficiency. A compact S-band (2856 MHz) one-input-three-output multiplexer prototype was designed, fabricated, and tested with both low and high power conditions. Furthermore, an accelerator array system equipped with a compact multiplexer and three accelerators has proven capable of rapid beamline switching. The rapid microwave distribution network offers a compact, efficient, and straightforward solution for the accelerator array system to achieve rapid multiangle radiation, paving the way for the application of novel technologies such as ultrahigh dose rate FLASH radiotherapy and industrial stationary CT.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (10) , 7665-7678
A Rapid Microwave Distribution Network for Accelerator Array System
This work presents a rapid microwave distribution network based on a compact multiplexer component, to cooperate with an accelerator array system for rapid multiangle radiation. Given the current limitation of high-power klystrons in output bandwidth, this distribution network achieves output branch switching with narrow frequency intervals, while maintaining high transmission efficiency. A compact S-band (2856 MHz) one-input-three-output multiplexer prototype was designed, fabricated, and tested with both low and high power conditions. Furthermore, an accelerator array system equipped with a compact multiplexer and three accelerators has proven capable of rapid beamline switching. The rapid microwave distribution network offers a compact, efficient, and straightforward solution for the accelerator array system to achieve rapid multiangle radiation, paving the way for the application of novel technologies such as ultrahigh dose rate FLASH radiotherapy and industrial stationary CT.
- Open Access
- 15 January 2025
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 12, 1496272
Design of a 100-MeV compact VHEE beam line in Tsinghua University
A 100-MeV Compact Electron Accelerator design has been proposed for Very High Energy Electron (VHEE) radiotherapy research at Tsinghua University. The microwave source for this system is a 50 MW X-band klystron, paired with a pulse compressor featuring a correction cavity chain. During high-power test, the system achieved a flat-top power gain three times the input. The acceleration system consists of three main components: a backward traveling-wave buncher that bunches and accelerates electrons from a thermionic cathode gun to 8 MeV, followed by two 72-cell X-band constant-gradient traveling-wave accelerating structures, which further increase the electron energy to 100 MeV with a gradient of 80 MV/m. The total length of the system is 1.8 m, and its design is detailed in this paper.
- 15 January 2025
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 12, 1496272
Open AccessDesign of a 100-MeV compact VHEE beam line in Tsinghua University
A 100-MeV Compact Electron Accelerator design has been proposed for Very High Energy Electron (VHEE) radiotherapy research at Tsinghua University. The microwave source for this system is a 50 MW X-band klystron, paired with a pulse compressor featuring a correction cavity chain. During high-power test, the system achieved a flat-top power gain three times the input. The acceleration system consists of three main components: a backward traveling-wave buncher that bunches and accelerates electrons from a thermionic cathode gun to 8 MeV, followed by two 72-cell X-band constant-gradient traveling-wave accelerating structures, which further increase the electron energy to 100 MeV with a gradient of 80 MV/m. The total length of the system is 1.8 m, and its design is detailed in this paper.
- 16 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (25)
The field emission characteristics under transient electric field
This article concentrates on the field emission (FE) characteristics under the pulsed transient electric field. Experimental measurements are carried out by applying direct current (DC) voltage, millisecond pulse voltage, and microsecond pulse voltage. Additionally, 304 stainless steel, oxygen-free copper and titanium electrodes are utilized to verify the consistency. Compared with the case under DC electric field, three distinctive FE characteristics are observed under pulsed transient electric field: the regular emission, the intense emission, and the annihilation phenomenon. First, the emission starting point implies one strong correlation with the second partial derivative of transient electric field strength with respect to time. Second, the emission current under pulsed electric field is much higher than that under the DC electric field. Moreover, the FE current is deeply associated with the gradient of the electric field during the rising front. Third, the FE current is extinguished though there is still high transient electric field. The mechanism of the three characteristics is still unclear and should be the subject of further investigation.
- 16 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (25)
The field emission characteristics under transient electric field
This article concentrates on the field emission (FE) characteristics under the pulsed transient electric field. Experimental measurements are carried out by applying direct current (DC) voltage, millisecond pulse voltage, and microsecond pulse voltage. Additionally, 304 stainless steel, oxygen-free copper and titanium electrodes are utilized to verify the consistency. Compared with the case under DC electric field, three distinctive FE characteristics are observed under pulsed transient electric field: the regular emission, the intense emission, and the annihilation phenomenon. First, the emission starting point implies one strong correlation with the second partial derivative of transient electric field strength with respect to time. Second, the emission current under pulsed electric field is much higher than that under the DC electric field. Moreover, the FE current is deeply associated with the gradient of the electric field during the rising front. Third, the FE current is extinguished though there is still high transient electric field. The mechanism of the three characteristics is still unclear and should be the subject of further investigation.
- Open Access
- 6 September 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (9) , 090401
Design and test of an -band constant gradient structureA light source project named very compact inverse Compton scattering gamma-ray source (VIGAS) is under development at Tsinghua University. VIGAS aims to generate monochromatic high-energy gamma rays by colliding 350-MeV electron beams with 400-nm laser photons within a 12-m beamline. To produce a high-energy electron beam in such a compact space, the system consists of an S-band high-brightness injector and six X-band high-gradient accelerating structures. The goal of the X-band structure is to operate at a high gradient of . Therefore, we adopts the constant gradient traveling wave approach, where the iris from the first cell to the end cell is tapered. The structure has 72 cells, including 70 cells and 2 couplers, so we named it XT72. The frequency of XT72 is selected to 11.424 GHz, and the mode is adopted. In this paper, we present a comprehensive study covering the detailed design, fabrication, rf tuning, and high-power test results of the first XT72. Additionally, we compare the performance of this structure to that of the previous constant impedance structure. Our results demonstrate that the XT72 is capable of operating at an gradient with a lower breakdown rate. This advancement paves the way for the development of VIGAS project and contributes to the wider application of X-band room-temperature high-gradient structures in compact accelerator facilities.- 6 September 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (9) , 090401
Open AccessDesign and test of an -band constant gradient structureA light source project named very compact inverse Compton scattering gamma-ray source (VIGAS) is under development at Tsinghua University. VIGAS aims to generate monochromatic high-energy gamma rays by colliding 350-MeV electron beams with 400-nm laser photons within a 12-m beamline. To produce a high-energy electron beam in such a compact space, the system consists of an S-band high-brightness injector and six X-band high-gradient accelerating structures. The goal of the X-band structure is to operate at a high gradient of . Therefore, we adopts the constant gradient traveling wave approach, where the iris from the first cell to the end cell is tapered. The structure has 72 cells, including 70 cells and 2 couplers, so we named it XT72. The frequency of XT72 is selected to 11.424 GHz, and the mode is adopted. In this paper, we present a comprehensive study covering the detailed design, fabrication, rf tuning, and high-power test results of the first XT72. Additionally, we compare the performance of this structure to that of the previous constant impedance structure. Our results demonstrate that the XT72 is capable of operating at an gradient with a lower breakdown rate. This advancement paves the way for the development of VIGAS project and contributes to the wider application of X-band room-temperature high-gradient structures in compact accelerator facilities. - 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (7) , 2661-2667
Method of Measuring Field Emission Current Under High-Voltage Pulse
A method of measuring field emission current under high-voltage (HV) pulse is proposed. The method makes it more convenient to study electron emission under HV pulse. Based on the Kirchhoff law, this method can fundamentally solve the problem, which the emission current is usually covered up by the displacement current. In addition, the method can ensure the safety of oscilloscope and the accuracy of the measurement when the gap gets breakdown. The resolution analysis of this method is carried out. The resolution is positively correlated with the output resistance and negatively correlated with the summation of output capacitance and electrodes capacitance. The resolution, under microsecond and millisecond HV pulse, can achieve $\mu$ A to A class. The measurement platform based on this method contains an energy-storage capacitor, a load resistor, an HV pulse power supply, an electrode cavity, and three resistor–capacitor ( R – C ) voltage dividers.
- 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (7) , 2661-2667
Method of Measuring Field Emission Current Under High-Voltage Pulse
A method of measuring field emission current under high-voltage (HV) pulse is proposed. The method makes it more convenient to study electron emission under HV pulse. Based on the Kirchhoff law, this method can fundamentally solve the problem, which the emission current is usually covered up by the displacement current. In addition, the method can ensure the safety of oscilloscope and the accuracy of the measurement when the gap gets breakdown. The resolution analysis of this method is carried out. The resolution is positively correlated with the output resistance and negatively correlated with the summation of output capacitance and electrodes capacitance. The resolution, under microsecond and millisecond HV pulse, can achieve $\mu$ A to A class. The measurement platform based on this method contains an energy-storage capacitor, a load resistor, an HV pulse power supply, an electrode cavity, and three resistor–capacitor ( R – C ) voltage dividers.