Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Oleg Odalović has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    EFFECTS OF EPOCH HARMONIZATION ON TERRESTRIAL AND GOCO-DERIVED HEIGHT ANOMALIES: CASE STUDY IN SERBIA

    by Oleg Odalović, Stefan Krstić, Dušan Petković, Sanja Grekulović, Miljana Todorović-Drakul

    Terrestrial height anomalies are compared with anomalies derived from Global Geopotential Models (GGMs) developed within the GOCO initiative. The analysis examines the influence of epoch differences on geometric heights. Terrestrial anomalies are determined from ellipsoidal heights obtained by GNSS and from precise levelling data. Ellipsoidal heights from 2005 are adjusted to the reference epoch 2025 using a velocity field derived from the European Permanent Network. The results indicate regional subsidence of about −1 mm per year. After temporal harmonization, root-mean-square of differences between terrestrially determined anomalies and those derived from GGMs is approximately 0.21 m for satellite-only models and 0.11 m for combined GGM.

  • Open Access

    Comparative analysis of ionospheric models and ionosonde observations across different solar conditions

    by Nikola Banković, Miljana Todorović-Drakul, Sanja Grekulović, Oleg Odalović, Dušan Petković, Stefan Krstić

    The study analyzes the structure and variability of the ionosphere, which affects the propagation of GNSS (Global Navigation Satellite System) signals. The focus is placed on the comparison of ionospheric models IRI (International Reference Ionosphere) and NeQuick with experimental data. The ionosphere is presented as a dynamic system whose changes depend on solar activity. Emphasis is placed on testing the models under quiet ionospheric conditions, as well as during periods of enhanced solar activity. The concept of total electron content (TEC) is explained as a key parameter for quantifying ionospheric delay of GNSS signals. The experimental part includes the analysis of data from three ionosondes (Athens, Sopron and Pruhonice) for selected time periods. Ionosonde derived values of vertical total electron content (VTEC), obtained by integrating electron density profiles, are compared with corresponding values obtained using the models. The highest TEC values during 9 January reached up to 40.6 TECU (Total Electron Content Units) in Pruhonice (IRI model). During the period from 10 to 13 May, maximum values were recorded, reaching 54.0 TECU in Athens (IRI model) and 49.1 TECU (NeQuick model). On 8 August, maximum values reached 52.3 TECU in Athens (IRI model). The highest value in Sopron was recorded during 10 to 13 May according to the IRI model (43.4 TECU). Throughout all analyzed periods, the models produced higher TEC values compared to ionosonde measurements.

  • Open Access

    Modeling of the vertical gravity gradient in the territory of the Republic of Kazakhstan: Methods, Comparison and Evaluation of Accuracy

    by Nikolay Kosarev, Oleg Odalovic, Roman Sermiagin, Denis Goldobin, Vadim Kanushin, Nurgan Kemerbayev, Andrei Sholomitskii

  • Open Access

    Development of High-Precision Local and Regional Ionospheric Models Based on Spherical Harmonic Expansion and Global Navigation Satellite System Data in Serbia

    by Dušan Petković, Oleg Odalović, Aleksandra Nina, Miljana Todorović-Drakul, Aleksandra Kolarski, Sanja Grekulović, Stefan Krstić

    The relationship between ionospheric research and global navigation satellite systems (GNSS) can be analysed through two approaches. The direct approach utilises ionospheric models to mitigate its influence, while the indirect approach leverages GNSS data to model ionospheric parameters. This study presents an indirect approach in which the total electron content (TEC), a fundamental parameter for ionospheric conditions, is modelled as a harmonic function using spherical harmonic (SH) expansion. Station-specific (local) and regional ionospheric models are developed by decomposing ionospheric influence into deterministic and stochastic components. GNSS data from seven evenly distributed stations in Serbia were used to estimate TEC coefficients. Local models were provided in the ION format as SH coefficients, allowing TEC determination at any epoch, while regional models had a 0.5∘×0.5∘ spatial and 2 h temporal resolution. The TEC root mean square (RMS) values ranged from 0.2 to 0.5 TECU (total electron content unit), with a mean of 0.3 TECU. Validation against global ionospheric maps showed agreement within 5.0 TECU. The impact of the SH expansion degree and order on TEC values was also analysed. These results refine regional ionospheric modelling, improving GNSS positioning accuracy in Serbia and beyond.


  • First look inside the gravity field of Montenegro

    by Danilo S. Joksimović, Oleg R. Odalović

  • Open Access

    Comparison of Total Electron Content Sources Over Europe During Solar Minimum and Maximum Years (2020 and 2024)

    by Stefan Krstić, Miljana Todorović-Drakul, Sanja Grekulović, Dušan Petković, Oleg Odalović

    In this paper, we presented a comparison of Total Electron Content (TEC) obtained from various sources: ionosondes, the IRI model, the NeQuick model, and Global Navigation Satellite Systems (GNSS). The study was conducted at multiple locations distributed evenly throughout Europe. We analyzed TEC values from the aforementioned sources during six days per year for 2020 and 2024. In our research, we found that ionosondes generally produce the smallest values of TEC. GNSS data provide TEC with the highest values during quiet periods, while the NeQuick model generates the highest values when solar and geomagnetic activity increases. Based on the correlation coefficient, diurnal variations in TECs from different sources showed significant similarities. Focusing on RMS (root mean square) values of TEC differences, we discovered that several TEC sources produce TECs with a satisfactory level of consistency across Europe. Consistency is around several TECU at solar minimum and within 10 TECU during solar maximum. TECs from the IRI and NeQuick models are highly consistent at both solar periods. During the solar minimum period, there are slightly larger discrepancies between TEC from ionosondes and those from the NeQuick model and GNSS, while other differences stay small. During the solar maximum period, ionosondes and the NeQuick model show the largest differences and variations.


  • Open Access

    Determination of coordinates of permanent stations for global positioning in the International Terrestrial Reference System

    by Stefan V. Krstić, Oleg R. Odalović, Dušan S. Petković

    The subject of this paper is the International Terrestrial Reference Frame 2020 (ITRF2020), which represents the current realization of the International Terrestrial Reference System (ITRS). On April 15, 2022, this reference frame was formally released to the public. This solution serves as the official reference frame for all international geoscience organizations as of November 27, 2022. In this article, the technology of Global Navigation Satellite Systems (GNSS) was used to estimate the coordinates of the points in the ITRF2020. For these purposes, 24 points on Serbian territory were chosen as permanent station reference points for global positioning. Four points near Serbia, whose coordinates are known within this frame, were used to establish a connection with the target frame. The collected data for obtaining the coordinates of the points refer to the time period 27.11.2022. - 03.12.2022. Points' coordinates calculations and data processing were done using Bernese GNSS software. Within the scope of solving the set problem, the daily solutions of the coordinates of the points were first found, and then the seven-day solutions were calculated by combining them. The final weekly coordinates of the points are determined with a millimeter standard deviation of the repeatability of the daily solutions and they belong to the reference moment of time on November 30, 2022, at 12:00:00.

  • Open Access

    A compliance assessment of GNSS station networks in Serbia

    by Oleg Odalovic, Dusan Petkovic, Sanja Grekulovic, Miljana Todorovic-Drakul

    Since the early 21st century, Global Positioning System (GPS) technology has dominated geodetic reference networks. Almost all countries established a permanent Global Navigation Satellite System (GNSS) station network to augment all available GNSS systems. By the end of 2005, Serbia completed the Active Geodetic Reference Network as a particular project of Serbia's Republic Geodetic Authority (RGA). Besides RGA, two private companies, Vekom and Geotaur, have established permanent station networks. This paper assesses the compliance of all the three networks, and network results are evaluated against the spatial distance determined by classical geodetic methods. When all available GNSS constellations are utilized, NAVSTAR, GLONASS, BEIDOU, and GALILEO, in the processing procedure, the established networks in Serbia align within a margin of about 3 mm across all coordinate axes. The results obtained within the research indicate that by using GNSS networks, it is possible to provide the coordinates of the points for the establishment of the national spatial reference system of Serbia, the reference system in almost all engineering fields, reference systems for the maintenance works of the real estate cadastre, and it is also possible to provide coordinates of points that can be used to define local, national, and world reference heights surfaces.