Yulia A. Yarkaeva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yulia A. Yarkaeva has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
V. N. Maistrenko
Faculty of Chemistry, Ufa University of Science and Technology, Ufa, Russia
8 shared publicationsR. A. Zil’BErg
Department of Chemistry, Bashkir State University, Ufa, Russia
7 shared publicationsA. V. Sidel’NIkov
Bashkir State University
4 shared publications- Valery N. Maistrenko
Bashkir State University, Ufa, Russia
4 shared publications Bashkir State University
3 shared publications- Rufina A. Zilberg
Ufa University of Science and Technology Ufa Russian Federation
3 shared publications
Latest Publications
- 21 June 2024
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 79 (6) , 680-689
A Voltammetric Sensor Based on a Chitosan, Graphitized Carbon Black, and Molecularly Imprinted Polyarylene Phthalide Composite for Clarithromycin Detection
A voltammetric sensor based on a glassy carbon electrode modified with a chitosan, Carboblack C graphitized carbon black, and molecularly imprinted polyarylene phthalide composite is developed for the selective detection of antibiotic clarithromycin. The polyarylene phthalide used for modification contains diphenylenethio- and diphenylene oxide fragments in a 1 : 2 ratio in the main polymer chain. Clarithromycin-imprinted polyarylene phthalide was obtained using the phase inversion method. The composition and morphology of the modifying coating were investigated by IR spectrometry and scanning electron microscopy. The electrochemical and analytical characteristics of the sensor were investigated by electrochemical impedance spectroscopy, cyclic voltammetry, and differential pulse voltammetry. Optimal conditions for recording the analytical signal were selected. Using [Fe(CN)6]3−/4− as a probe, the linear range of the detected concentrations was found to be 1 × 10–7–5 × 10–4 M with a limit of detection of 5.3 × 10–8 M. Using a clarithromycin-imprinted polymer enhances the sensor sensitivity by nearly tenfold compared to the nonimprinted polymer. The proposed sensor was tested using urine, blood plasma, and various food samples (meat, milk), the recovery values were 90–96, 80, and 92%, respectively, with relative standard deviations not exceeding 10% in all cases.
- 21 June 2024
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 79 (6) , 680-689
A Voltammetric Sensor Based on a Chitosan, Graphitized Carbon Black, and Molecularly Imprinted Polyarylene Phthalide Composite for Clarithromycin Detection
A voltammetric sensor based on a glassy carbon electrode modified with a chitosan, Carboblack C graphitized carbon black, and molecularly imprinted polyarylene phthalide composite is developed for the selective detection of antibiotic clarithromycin. The polyarylene phthalide used for modification contains diphenylenethio- and diphenylene oxide fragments in a 1 : 2 ratio in the main polymer chain. Clarithromycin-imprinted polyarylene phthalide was obtained using the phase inversion method. The composition and morphology of the modifying coating were investigated by IR spectrometry and scanning electron microscopy. The electrochemical and analytical characteristics of the sensor were investigated by electrochemical impedance spectroscopy, cyclic voltammetry, and differential pulse voltammetry. Optimal conditions for recording the analytical signal were selected. Using [Fe(CN)6]3−/4− as a probe, the linear range of the detected concentrations was found to be 1 × 10–7–5 × 10–4 M with a limit of detection of 5.3 × 10–8 M. Using a clarithromycin-imprinted polymer enhances the sensor sensitivity by nearly tenfold compared to the nonimprinted polymer. The proposed sensor was tested using urine, blood plasma, and various food samples (meat, milk), the recovery values were 90–96, 80, and 92%, respectively, with relative standard deviations not exceeding 10% in all cases.
- Open Access
- 28 April 2023
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 10 (2) , 202310210
Voltammetric sensor based on molecular imprinted polymer for lincomycin determination
For the selective detection of the antibiotic lincomycin, we developed a voltammetric sensor based on a glassy carbon electrode modified with reduced graphene oxide and polyarylenephthalide containing diphenylenethio and diphenyleneoxide fragments in the main chain of the polymer in the 1:1 ratio with lincomycin molecular imprints obtained by phase inversion. Using FTIR spectroscopy, electrochemical impedance spectroscopy, cyclic and differential-pulse voltammetry, the electrochemical and analytical characteristics of the sensor were studied. The detection of lincomycin was carried out by differential pulse voltammetry. The linear concentration range was 2.5·10–7–5·10–4 M with a limit of detection of 6.8·10–8 M. It was shown that the presence of molecular imprints increases the sensitivity of the developed sensor in comparisons with a sensor with non-imprinted polymer by a factor of 3.05.
- 28 April 2023
- Published by Ural Federal University in Chimica Techno Acta
- Vol. 10 (2) , 202310210
Open AccessVoltammetric sensor based on molecular imprinted polymer for lincomycin determination
For the selective detection of the antibiotic lincomycin, we developed a voltammetric sensor based on a glassy carbon electrode modified with reduced graphene oxide and polyarylenephthalide containing diphenylenethio and diphenyleneoxide fragments in the main chain of the polymer in the 1:1 ratio with lincomycin molecular imprints obtained by phase inversion. Using FTIR spectroscopy, electrochemical impedance spectroscopy, cyclic and differential-pulse voltammetry, the electrochemical and analytical characteristics of the sensor were studied. The detection of lincomycin was carried out by differential pulse voltammetry. The linear concentration range was 2.5·10–7–5·10–4 M with a limit of detection of 6.8·10–8 M. It was shown that the presence of molecular imprints increases the sensitivity of the developed sensor in comparisons with a sensor with non-imprinted polymer by a factor of 3.05.
Enantioselective voltammetric sensor based on mesoporous graphitized carbon black Carbopack X and fulvene derivative
For medicine and pharmaceuticals, the problem of determining and recognizing the enantiomers of biologically active compounds is an actual issue because the enantiomers of the same substance can have different effects on living organisms. This paper describes the development of an enantioselective voltammetric sensor (EVS) based on a glassy carbon electrode (GCE) modified with mesoporous graphitized carbon black Carbopack X (CpX) and a fulvene derivative (1S,4R)‐2‐cyclopenta‐2,4‐dien‐1‐ylidene‐1‐isopropyl‐4‐methylcyclohexane (CpIPMC) for recognition and determination of tryptophan (Trp) enantiomers. Synthesized CpIPMC was characterized by 1H and 13C nuclear magnetic resonance (NMR), chromatography–mass spectrometry, and polarimetry. The proposed sensor platform was studied by Fourier‐transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Using the square‐wave voltammetry (SWV), it was established that the developed sensor is an effective chiral platform for the quantitative determination of Trp enantiomers, including in a mixture and in biological fluids like urine and blood plasma, with adequate precision and recovery ranged from 96% to 101%.
Enantioselective voltammetric sensor based on mesoporous graphitized carbon black Carbopack X and fulvene derivative
For medicine and pharmaceuticals, the problem of determining and recognizing the enantiomers of biologically active compounds is an actual issue because the enantiomers of the same substance can have different effects on living organisms. This paper describes the development of an enantioselective voltammetric sensor (EVS) based on a glassy carbon electrode (GCE) modified with mesoporous graphitized carbon black Carbopack X (CpX) and a fulvene derivative (1S,4R)‐2‐cyclopenta‐2,4‐dien‐1‐ylidene‐1‐isopropyl‐4‐methylcyclohexane (CpIPMC) for recognition and determination of tryptophan (Trp) enantiomers. Synthesized CpIPMC was characterized by 1H and 13C nuclear magnetic resonance (NMR), chromatography–mass spectrometry, and polarimetry. The proposed sensor platform was studied by Fourier‐transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Using the square‐wave voltammetry (SWV), it was established that the developed sensor is an effective chiral platform for the quantitative determination of Trp enantiomers, including in a mixture and in biological fluids like urine and blood plasma, with adequate precision and recovery ranged from 96% to 101%.
- 14 November 2021
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 76 (11) , 1345-1354
A Sensor for the Recognition and Determination of Tryptophan Enantiomers Based on Carbon-Paste Electrode Modified by Enantiomorphic Crystals of Bromotriphenylmethane
We developed an enantioselective voltammetric sensor based on a carbon-paste electrode modified by enantiomorphic crystals of bromotriphenylmethane for the recognition and determination of tryptophan enantiomers. Enantiomorphic crystals of bromotriphenylmethane were obtained under the condition of Viedma ripening. The electrochemical and analytical characteristics of the sensor were studied. The proposed sensor was used to recognize and determine the enantiomers of L- and D-tryptophan in model solutions of pharmaceutical preparations and in human urine and blood plasma samples. The sensor is easy to manufacture and exhibits high reproducibility and stability. It was shown that, in using chemometric data processing, the presence of even slight differences between the voltammograms of enantiomers recorded using the proposed carbon-paste electrode is sufficient for their reliable recognition.
- 14 November 2021
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 76 (11) , 1345-1354
A Sensor for the Recognition and Determination of Tryptophan Enantiomers Based on Carbon-Paste Electrode Modified by Enantiomorphic Crystals of Bromotriphenylmethane
We developed an enantioselective voltammetric sensor based on a carbon-paste electrode modified by enantiomorphic crystals of bromotriphenylmethane for the recognition and determination of tryptophan enantiomers. Enantiomorphic crystals of bromotriphenylmethane were obtained under the condition of Viedma ripening. The electrochemical and analytical characteristics of the sensor were studied. The proposed sensor was used to recognize and determine the enantiomers of L- and D-tryptophan in model solutions of pharmaceutical preparations and in human urine and blood plasma samples. The sensor is easy to manufacture and exhibits high reproducibility and stability. It was shown that, in using chemometric data processing, the presence of even slight differences between the voltammograms of enantiomers recorded using the proposed carbon-paste electrode is sufficient for their reliable recognition.
- 1 January 2021
- Published by Ural Federal University in Аналитика и контроль
- Vol. 25 (3) , 193-204
Voltammetric sensor based on the copper (II) amino acid complex for the determination of tryptophan enantiomers
ВОЛЬТАМПЕРОМЕТРИЧЕСКИЙ СЕНСОР НА ОСНОВЕ АМИНОКИСЛОТНОГО КОМПЛЕКСА МЕДИ (II) ДЛЯ ОПРЕДЕЛЕНИЯ ЭНАНТИОМЕРОВ ТРИПТОФАНА
- 1 January 2021
- Published by Ural Federal University in Аналитика и контроль
- Vol. 25 (3) , 193-204
Voltammetric sensor based on the copper (II) amino acid complex for the determination of tryptophan enantiomers
ВОЛЬТАМПЕРОМЕТРИЧЕСКИЙ СЕНСОР НА ОСНОВЕ АМИНОКИСЛОТНОГО КОМПЛЕКСА МЕДИ (II) ДЛЯ ОПРЕДЕЛЕНИЯ ЭНАНТИОМЕРОВ ТРИПТОФАНА
- 19 December 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (12) , 1537-1545
A Voltammetric Sensor Based on a 3,4,9,10-Perylenetetracarboxylic Acid Composite for the Recognition and Determination of Tyrosine Enantiomers
An enantioselective voltammetric sensor based on a glassy carbon electrode modified with a composite of a polyelectrolyte complex of chitosan, Carboblack C graphitized thermal carbon black, and 3,4,9,10-perylenetetracarboxylic acid is developed for the recognition and determination of tyrosine enantiomers. The enantioselectivity of the sensor is due to the formation of self-organizing chiral nanoclusters of 3,4,9,10-perylenetetracarboxylic acid. The electrochemical and analytical characteristics of the sensor are studied. The proposed sensor is used to recognize and determine L- and D-enantiomers of tyrosine in samples of urine and human blood plasma, as well as in a mixture. To increase the probability of the recognition of tyrosine enantiomers in determining them in a mixture, the chemometric method of projection to latent structures is used. It is shown that the proposed sensor ensures the determination of the ratio of L- and D-enantiomers of tyrosine in a mixture with a high probability and a relative error of less than 8%.
- 19 December 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (12) , 1537-1545
A Voltammetric Sensor Based on a 3,4,9,10-Perylenetetracarboxylic Acid Composite for the Recognition and Determination of Tyrosine Enantiomers
An enantioselective voltammetric sensor based on a glassy carbon electrode modified with a composite of a polyelectrolyte complex of chitosan, Carboblack C graphitized thermal carbon black, and 3,4,9,10-perylenetetracarboxylic acid is developed for the recognition and determination of tyrosine enantiomers. The enantioselectivity of the sensor is due to the formation of self-organizing chiral nanoclusters of 3,4,9,10-perylenetetracarboxylic acid. The electrochemical and analytical characteristics of the sensor are studied. The proposed sensor is used to recognize and determine L- and D-enantiomers of tyrosine in samples of urine and human blood plasma, as well as in a mixture. To increase the probability of the recognition of tyrosine enantiomers in determining them in a mixture, the chemometric method of projection to latent structures is used. It is shown that the proposed sensor ensures the determination of the ratio of L- and D-enantiomers of tyrosine in a mixture with a high probability and a relative error of less than 8%.
- 1 July 2020
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 56 (7) , 544-555
Voltammetric Sensors and Sensor System Based on Gold Electrodes Modified with Polyarylenephthalides for Cysteine Recognition
- 1 July 2020
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 56 (7) , 544-555
Voltammetric Sensors and Sensor System Based on Gold Electrodes Modified with Polyarylenephthalides for Cysteine Recognition
- 1 January 2019
- Published by Ural Federal University in Аналитика и контроль
- Vol. 23 (4) , 546-556
Voltammetric multisensory system based on glassy carbon electrodes modified by polyarylenephthalides for the recognition and determination of warfarin
ВОЛЬТАМПЕРОМЕТРИЧЕСКАЯ МУЛЬТИСЕНСОРНАЯ СИСТЕМА НА ОСНОВЕ МОДИФИЦИРОВАННЫХ ПОЛИАРИЛЕНФТАЛИДАМИ СТЕКЛОУГЛЕРОДНЫХ ЭЛЕКТРОДОВ ДЛЯ РАСПОЗНАВАНИЯ И ОПРЕДЕЛЕНИЯ ВАРФАРИНА
- 1 January 2019
- Published by Ural Federal University in Аналитика и контроль
- Vol. 23 (4) , 546-556
Voltammetric multisensory system based on glassy carbon electrodes modified by polyarylenephthalides for the recognition and determination of warfarin
ВОЛЬТАМПЕРОМЕТРИЧЕСКАЯ МУЛЬТИСЕНСОРНАЯ СИСТЕМА НА ОСНОВЕ МОДИФИЦИРОВАННЫХ ПОЛИАРИЛЕНФТАЛИДАМИ СТЕКЛОУГЛЕРОДНЫХ ЭЛЕКТРОДОВ ДЛЯ РАСПОЗНАВАНИЯ И ОПРЕДЕЛЕНИЯ ВАРФАРИНА
- 1 January 2018
- Published by Ural Federal University in Аналитика и контроль
- Vol. 22 (3) , 292-302
Voltammetric determination of propranolol enantiomers in the model solutions of pharmaceutical forms and biological fluids
ВОЛЬТАМПЕРОМЕТРИЧЕСКОЕ ОПРЕДЕЛЕНИЕ ЭНАНТИОМЕРОВ ПРОПРАНОЛОЛА В МОДЕЛЬНЫХ РАСТВОРАХ ЛЕКАРСТВЕННЫХ ФОРМ И БИОЛОГИЧЕСКИХ ЖИДКОСТЯХ
- 1 January 2018
- Published by Ural Federal University in Аналитика и контроль
- Vol. 22 (3) , 292-302
Voltammetric determination of propranolol enantiomers in the model solutions of pharmaceutical forms and biological fluids
ВОЛЬТАМПЕРОМЕТРИЧЕСКОЕ ОПРЕДЕЛЕНИЕ ЭНАНТИОМЕРОВ ПРОПРАНОЛОЛА В МОДЕЛЬНЫХ РАСТВОРАХ ЛЕКАРСТВЕННЫХ ФОРМ И БИОЛОГИЧЕСКИХ ЖИДКОСТЯХ
- 13 September 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (4) , 619-625
A Voltammetric Sensory System for Recognition of Propranolol Enantiomers Based on Glassy Carbon Electrodes Modified by Polyarylenephthalide Composites of Melamine and Cyanuric Acid
An enantioselective voltammetric sensory system based on glassy carbon electrodes modified by polyarylenephthalide composites of melamine and cyanuric acid using chemometric method principal component analysis for the recognition of propranolol enantiomers was developed. It is shown that glassy carbon electrodes modified by polyarylenephthalide composites of melamine and cyanuric acid exhibit the properties of enantioselective sensors. The molecular dynamics simulations of the interaction processes of propranolol enantiomers with polyarylenephthalide composites of melamine and cyanuric acid show that the differences between the voltammograms of propranolol enantiomers on such electrodes are due to differences in the energy of hydrogen bonds formation between enantiomeric molecules and supramolecules of melamine and cyanuric acid. This is reflected not only in the characteristics and shape of the voltammograms, but also in the sensitivity of the electrodes, with respect to the propranolol enantiomers. The possibilities of the sensory system for express recognition of R‐ and S‐propranolol are considered. The recognition of these enantiomers by the registered voltammograms on two glassy carbon electrodes modified by polyarylenephthalide composites of melamine and cyanuric acid allows to increase significantly the percentage of correctly recognised samples in comparison with the registration of voltammograms on only one electrode.
- 13 September 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (4) , 619-625
A Voltammetric Sensory System for Recognition of Propranolol Enantiomers Based on Glassy Carbon Electrodes Modified by Polyarylenephthalide Composites of Melamine and Cyanuric Acid
An enantioselective voltammetric sensory system based on glassy carbon electrodes modified by polyarylenephthalide composites of melamine and cyanuric acid using chemometric method principal component analysis for the recognition of propranolol enantiomers was developed. It is shown that glassy carbon electrodes modified by polyarylenephthalide composites of melamine and cyanuric acid exhibit the properties of enantioselective sensors. The molecular dynamics simulations of the interaction processes of propranolol enantiomers with polyarylenephthalide composites of melamine and cyanuric acid show that the differences between the voltammograms of propranolol enantiomers on such electrodes are due to differences in the energy of hydrogen bonds formation between enantiomeric molecules and supramolecules of melamine and cyanuric acid. This is reflected not only in the characteristics and shape of the voltammograms, but also in the sensitivity of the electrodes, with respect to the propranolol enantiomers. The possibilities of the sensory system for express recognition of R‐ and S‐propranolol are considered. The recognition of these enantiomers by the registered voltammograms on two glassy carbon electrodes modified by polyarylenephthalide composites of melamine and cyanuric acid allows to increase significantly the percentage of correctly recognised samples in comparison with the registration of voltammograms on only one electrode.