Fernando Ovalles
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fernando Ovalles has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Maurizia Rossana Brunetto
IVAIQUIM (Andean Institute for Chemical Research), Faculty of Sciences, University of Los Andes, Mérida, Venezuela
7 shared publications - Máximo Gallignani
Molecular Spectroscopy Laboratory, Department of Chemistry, Faculty of Sciences, Los Andes University, La Hechicera, Mérida 5101, Venezuela
4 shared publications Carlos Ayala
Laboratorio de Espectroscopia Molecular, Departamento de Química, Facultad de Ciencias, Universidad de Los Andes, Mérida 5101A, Venezuela
3 shared publicationsMáximo Gallignani
3 shared publicationsRebeca A. Rondón
Laboratorio de Espectroscopia Molecular, Departamento de Química, Facultad de Ciencias, Universidad de Los Andes, Mérida 5101-A, Venezuela
2 shared publicationsAna Luisa Medina G
Universidad de los Andes (ULA), Mérida, Venezuela
1 shared publication
Latest Publications
- Open Access
- 1 October 2014
- Published by Elsevier in Acta Pharmaceutica Sinica B
- Vol. 4 (5) , 376-383
Transmission FTIR derivative spectroscopy for estimation of furosemide in raw material and tablet dosage form
- 1 October 2014
- Published by Elsevier in Acta Pharmaceutica Sinica B
- Vol. 4 (5) , 376-383
Open AccessTransmission FTIR derivative spectroscopy for estimation of furosemide in raw material and tablet dosage form
- Open Access
- 1 April 2014
- Published by Elsevier in Journal of Pharmaceutical Analysis
- Vol. 4 (2) , 125-131
Reagent-free determination of amikacin content in amikacin sulfate injections by FTIR derivative spectroscopy in a continuous flow system
- 1 April 2014
- Published by Elsevier in Journal of Pharmaceutical Analysis
- Vol. 4 (2) , 125-131
Open AccessReagent-free determination of amikacin content in amikacin sulfate injections by FTIR derivative spectroscopy in a continuous flow system
- 1 June 2013
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Revista chilena de nutrición
- Vol. 40 (2) , 147-154
Valoración de dietas para alevines de Colossoma macropomum utilizando como fuentes proteicas harinas: de lombriz (Eisenia foetida), soya (Glycine max) y caraotas (Phaseolus vulgaris)
- 1 June 2013
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Revista chilena de nutrición
- Vol. 40 (2) , 147-154
Valoración de dietas para alevines de Colossoma macropomum utilizando como fuentes proteicas harinas: de lombriz (Eisenia foetida), soya (Glycine max) y caraotas (Phaseolus vulgaris)
- 1 January 2013
- Published by Elsevier in Current Pharmaceutical Analysis
- Vol. 9 (1) , 20-30
Proposal for Determining Sulfate Counter Ion in Amikacin Sulfate Formulations by Fourier-Transform Infrared Derivative Spectroscopy
Amikacin (AMK) is a semi-synthetic aminoglycoside antibiotic used under the sulfate salt form and manufactured under parenteral formulations. The determination of the sulfate concentration is important to confirm the completeness of salt formation. Continuing the approach followed by some authors in FTIR spectroscopy, the principle of using analyses of aqueous samples in the mid-IR region, by transmission, was adopted as a tool for the development of the proposed approach. Spectroscopic discrimination between the sulfate counter ion and the carbohydrate moiety was achieved by using derivative spectroscopy. The selected measurement criterion was the amplitude from the minimum of the negative wavenumber band (1054 cm-1) of the 1st order derivative spectrum to a cross-over point coincident with the maximum negative slope of the conventional absorbance spectrum. Linear response (r > 0.999) was observed for sulfate concentrations in the range 2.5 to 25 (mg mL-1), with a detection limit of 0.4 mg mL-1. The sampling frequency was estimated as 13 measurements per hour in a continuous flow mode sample-to-sample with a coefficient of variation < 0.5 % (n = 10). The found equivalent sulfate content in AMK sulfate formulations showed in most cases a good agreement with the values declared on the label of each analyzed pharmaceutical product. The proposed analytical strategy allows the analysis of the sample either directly or just requiring only an aqueous dilution which can be understood as a green analytical approach alternative to methods employing either titrimetric approaches or chromatographic and electrophoretic separation methods.
- 1 January 2013
- Published by Elsevier in Current Pharmaceutical Analysis
- Vol. 9 (1) , 20-30
Proposal for Determining Sulfate Counter Ion in Amikacin Sulfate Formulations by Fourier-Transform Infrared Derivative Spectroscopy
Amikacin (AMK) is a semi-synthetic aminoglycoside antibiotic used under the sulfate salt form and manufactured under parenteral formulations. The determination of the sulfate concentration is important to confirm the completeness of salt formation. Continuing the approach followed by some authors in FTIR spectroscopy, the principle of using analyses of aqueous samples in the mid-IR region, by transmission, was adopted as a tool for the development of the proposed approach. Spectroscopic discrimination between the sulfate counter ion and the carbohydrate moiety was achieved by using derivative spectroscopy. The selected measurement criterion was the amplitude from the minimum of the negative wavenumber band (1054 cm-1) of the 1st order derivative spectrum to a cross-over point coincident with the maximum negative slope of the conventional absorbance spectrum. Linear response (r > 0.999) was observed for sulfate concentrations in the range 2.5 to 25 (mg mL-1), with a detection limit of 0.4 mg mL-1. The sampling frequency was estimated as 13 measurements per hour in a continuous flow mode sample-to-sample with a coefficient of variation < 0.5 % (n = 10). The found equivalent sulfate content in AMK sulfate formulations showed in most cases a good agreement with the values declared on the label of each analyzed pharmaceutical product. The proposed analytical strategy allows the analysis of the sample either directly or just requiring only an aqueous dilution which can be understood as a green analytical approach alternative to methods employing either titrimetric approaches or chromatographic and electrophoretic separation methods.
- Open Access
- 1 January 2009
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 32 (2) , 337-342
Flow analysis-hydride generation-gas phase derivative molecular absorption spectrophotometric determination of antimony in antileishmanial drugs
In the present work, the development of a method based on the coupling of flow analysis (FA), hydride generation (HG), and derivative molecular absorption spectrophotometry (D-EAM) in gas phase (GP), is described in order to determine total antimony in antileishmanial products. Second derivative order (D²224nm) of the absorption spectrum (190 - 300 nm) is utilized as measurement criterion. Each one of the parameters involved in the development of the proposed method was examined and optimized. The utilization of the EAM in GP as detection system in a continuous mode instead of atomic absorption spectrometry represents the great potential of the analytic proposal.
- 1 January 2009
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 32 (2) , 337-342
Open AccessFlow analysis-hydride generation-gas phase derivative molecular absorption spectrophotometric determination of antimony in antileishmanial drugs
In the present work, the development of a method based on the coupling of flow analysis (FA), hydride generation (HG), and derivative molecular absorption spectrophotometry (D-EAM) in gas phase (GP), is described in order to determine total antimony in antileishmanial products. Second derivative order (D²224nm) of the absorption spectrum (190 - 300 nm) is utilized as measurement criterion. Each one of the parameters involved in the development of the proposed method was examined and optimized. The utilization of the EAM in GP as detection system in a continuous mode instead of atomic absorption spectrometry represents the great potential of the analytic proposal.