Serkan Doganay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Serkan Doganay has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alpaslan Turgut
Department of Mechanical Engineering, Dokuz Eylul University, Izmir, Turkey
9 shared publications - Levent Cetin
Izmir Katip Celebi University
4 shared publications Alpaslan Turgut
Department of Mechanical Engineering, Dokuz Eylül University, Turkey
3 shared publicationsLevent Çetin
3 shared publicationsHalil Dogacan Koca
2 shared publications- İsmet Ateş
The Graduate School of Natural and Applied Sciences, Mechatronics Engineering Department, Tinaztepe Campus, Dokuz Eylul University, 35397 Buca, Izmir, Turkey
2 shared publications
Latest Publications
- 30 October 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 397
Manipulation of magnetic nanofluids by a Lagrange point-based permanent magnetic actuator for micropumping applications
- 30 October 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 397
Manipulation of magnetic nanofluids by a Lagrange point-based permanent magnetic actuator for micropumping applications
- Open Access
- 22 May 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 066003
Auto-balancing method development for the Wheatstone bridge to detect harmonics: implementation on 3omega hot wire method
The goal of this study is to develop an automatic balancing method for the accurate detection of harmonics in the 3omega hot wire (3ωHW) method for the thermal conductivity measurement of liquids. To detect harmonics, an essential requirement is the elimination of the fundamental voltage on bridge output caused by the excitation. For this purpose, a closed-loop control circuit exploiting a digitally controlled potentiometer was designed and an application-specific algorithm was developed to manage the bridge balancing automatically. The developed method was then integrated into the conventional 3ωHW method to eliminate uncertainties in the manual balancing process. Following, the performance tests were carried out with the auto-balanced 3ωHW setup in the dynamic range of thermal conductivity 0.127–0.710 W m−1 K−1, including both base fluids and nanofluids. The ratio between the 3ω voltage and the fundamental one is enhanced from 10−4 to approximately 100 in 3.7 s without any manual adjustment.
- 22 May 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 066003
Open AccessAuto-balancing method development for the Wheatstone bridge to detect harmonics: implementation on 3omega hot wire method
The goal of this study is to develop an automatic balancing method for the accurate detection of harmonics in the 3omega hot wire (3ωHW) method for the thermal conductivity measurement of liquids. To detect harmonics, an essential requirement is the elimination of the fundamental voltage on bridge output caused by the excitation. For this purpose, a closed-loop control circuit exploiting a digitally controlled potentiometer was designed and an application-specific algorithm was developed to manage the bridge balancing automatically. The developed method was then integrated into the conventional 3ωHW method to eliminate uncertainties in the manual balancing process. Following, the performance tests were carried out with the auto-balanced 3ωHW setup in the dynamic range of thermal conductivity 0.127–0.710 W m−1 K−1, including both base fluids and nanofluids. The ratio between the 3ω voltage and the fundamental one is enhanced from 10−4 to approximately 100 in 3.7 s without any manual adjustment.
- Open Access
- 27 September 2024
- Published by Deu Muhendislik Fakultesi Fen ve Muhendislik in Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi
- Vol. 26 (78) , 512-518
Development of an Automatic Liquid Dosing System in Microliter Scale
The goal of this study is to design a novel automatic liquid dosing system for liquid sampling at the microliter level. For this purpose, a mechatronics system is designed to position a syringe at the desired position in the workspace and then drive its piston to inject the liquid to be sampled. Then, an application-specific algorithm is developed to be able to prepare samples in 3x3, 4x4, and 5x5 sample container arrays with a desired volume. The performance tests are conducted for preparing samples with up to three different liquids. The repetitive experiments are performed for 50 and 100 µL sampling volumes. The results indicated that it is possible to dose a single liquid with the highest average deviation of 3.9%. Moreover, it is found that it is possible to prepare a sample with a mixture of three liquids by the highest average deviation from the reference value of around 3.4% when the targeting sampling volume is 250 µL for each liquid.
- 27 September 2024
- Published by Deu Muhendislik Fakultesi Fen ve Muhendislik in Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi
- Vol. 26 (78) , 512-518
Open AccessDevelopment of an Automatic Liquid Dosing System in Microliter Scale
The goal of this study is to design a novel automatic liquid dosing system for liquid sampling at the microliter level. For this purpose, a mechatronics system is designed to position a syringe at the desired position in the workspace and then drive its piston to inject the liquid to be sampled. Then, an application-specific algorithm is developed to be able to prepare samples in 3x3, 4x4, and 5x5 sample container arrays with a desired volume. The performance tests are conducted for preparing samples with up to three different liquids. The repetitive experiments are performed for 50 and 100 µL sampling volumes. The results indicated that it is possible to dose a single liquid with the highest average deviation of 3.9%. Moreover, it is found that it is possible to prepare a sample with a mixture of three liquids by the highest average deviation from the reference value of around 3.4% when the targeting sampling volume is 250 µL for each liquid.
- 20 March 2024
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 596
Modeling and control of magnetically actuated micro/milli robots position under laminar flow
- 20 March 2024
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 596
Modeling and control of magnetically actuated micro/milli robots position under laminar flow
- Open Access
- 31 January 2024
- Published by Izmir UOD in Scientific Research Communications
- Vol. 4 (1) , 1-11
Implementation of 3Omega Method for a Wide Range Measurements of Thermal Conductivity of Liquids
Thermal conductivity is an important thermophysical property of materials. The advancements in material sciences and manufacturing techniques have led to the development of various techniques for thermal conductivity measurements. Among these methods, the AC hot wire (3 omega) method is a prominent option due to its advantages such as insensitivity to black body radiation and minimal sample requirement. Even though this measurement method has been quite popular in thermal conductivity measurements of thin films for several decades and is gathering attention for the measurements of liquids, there are no studies where the hardware of the measurement methodology is depicted as the method is quite complicated. In this study, a custom-made 3omega setup is presented and its performance in a wide range of thermal conductivity measurements is evaluated by investigating the thermal conductivity of base fluids such as water, ethanol, methanol, ethylene glycol (EG), and mineral oil. In addition, the relative thermal conductivity of the base fluids is compared with the literature. The proposed setup shows that the maximum error rates were obtained in a range of 0.5 to 5% depending on the base fluid.
- 31 January 2024
- Published by Izmir UOD in Scientific Research Communications
- Vol. 4 (1) , 1-11
Open AccessImplementation of 3Omega Method for a Wide Range Measurements of Thermal Conductivity of Liquids
Thermal conductivity is an important thermophysical property of materials. The advancements in material sciences and manufacturing techniques have led to the development of various techniques for thermal conductivity measurements. Among these methods, the AC hot wire (3 omega) method is a prominent option due to its advantages such as insensitivity to black body radiation and minimal sample requirement. Even though this measurement method has been quite popular in thermal conductivity measurements of thin films for several decades and is gathering attention for the measurements of liquids, there are no studies where the hardware of the measurement methodology is depicted as the method is quite complicated. In this study, a custom-made 3omega setup is presented and its performance in a wide range of thermal conductivity measurements is evaluated by investigating the thermal conductivity of base fluids such as water, ethanol, methanol, ethylene glycol (EG), and mineral oil. In addition, the relative thermal conductivity of the base fluids is compared with the literature. The proposed setup shows that the maximum error rates were obtained in a range of 0.5 to 5% depending on the base fluid.
- 27 January 2023
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 45 (8) , 1558-1569
Constant flow rate micropumping using closed-loop control of magnetically actuated nanofluid
In this study, a magnetic actuator is controlled to obtain a constant flow rate micropumping by a magnetic nanofluid flow inside a semicircular-shaped microchannel with a constant square cross-section. A closed-loop control strategy is developed to achieve adequate control by utilizing a model based on experimental data. A novel digital image processing–based real-time velocity estimation algorithm is proposed as feedback information in the closed-loop control system. This paper aims to evaluate the success of the proposed real-time velocity estimation algorithm. The results indicate that the proposed algorithm can supply the fluid velocity inside the microchannel with a maximum deviation of less than 4% in the current micropumping system. Three different controllers—that is, proportional (P), proportional–integral (PI), and proportional–integral–derivative (PID)—are also implemented to test the influence of the control logic used in the closed-loop control strategy. Compared with the previous study, the implementation of a closed-loop control strategy in the present work provided a constant flow rate pumping. The findings reveal that the PID controller can maintain a constant flow rate with transient time values around 186, 94, and 60 seconds for reference values of 100, 200, and 300 µm/s, respectively. In addition, the PID controller could supply a constant flow rate within the microchannel 51% longer than the PI controller.
- 27 January 2023
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 45 (8) , 1558-1569
Constant flow rate micropumping using closed-loop control of magnetically actuated nanofluid
In this study, a magnetic actuator is controlled to obtain a constant flow rate micropumping by a magnetic nanofluid flow inside a semicircular-shaped microchannel with a constant square cross-section. A closed-loop control strategy is developed to achieve adequate control by utilizing a model based on experimental data. A novel digital image processing–based real-time velocity estimation algorithm is proposed as feedback information in the closed-loop control system. This paper aims to evaluate the success of the proposed real-time velocity estimation algorithm. The results indicate that the proposed algorithm can supply the fluid velocity inside the microchannel with a maximum deviation of less than 4% in the current micropumping system. Three different controllers—that is, proportional (P), proportional–integral (PI), and proportional–integral–derivative (PID)—are also implemented to test the influence of the control logic used in the closed-loop control strategy. Compared with the previous study, the implementation of a closed-loop control strategy in the present work provided a constant flow rate pumping. The findings reveal that the PID controller can maintain a constant flow rate with transient time values around 186, 94, and 60 seconds for reference values of 100, 200, and 300 µm/s, respectively. In addition, the PID controller could supply a constant flow rate within the microchannel 51% longer than the PI controller.
- 25 May 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 30 (7) , 075012
A rotating permanent magnetic actuator for micropumping devices with magnetic nanofluids
In this study, a novel rotating permanent magnetic actuator (PMA) system is proposed to manipulate magnetic nanofluids to pump chemicals inside micro-sized channels with circular paths. The PMA consists of two permanent magnet pairs and a rotor-like structure. A semicircular-shaped microchannel with a square cross-section area is located at the top of the actuator in order to investigate the performance of the PMA. Fe 3 O 4 -water magnetic nanofluid is employed as a working fluid for the manipulation inside the microchannel. In the first stage of this work, a numerical survey is conducted to determine the most suitable angular distance between permanent magnets of a pair in terms of generated magnetic field form in the microchannel region and velocity distribution of magnetic nanofluid within the semicircular microchannel when the permanent magnets are stationary. Preliminary experiments are then carried out for the stationary permanent magnets to validate the predicted flow-field results. Performance tests for different PMA speeds (7.5–30 rpm) and particle concentrations (1%–3% by vol.) indicate that it is possible to manipulate the magnetic nanofluid inside the semicircular channel within a velocity range of 58.7–940 µ m s −1 , which corresponds to a flow rate range of 0.56–9.02 µ L min −1 . The results confirm that the proposed PMA system provides flow rate requirements in analytical microfluidic applications such as low flow drug delivery (1–10 µ L min −1 ), cell sorting (6.1 µ L min −1 ), and pathogen detection (3–5.83 µ L min −1 ).
- 25 May 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 30 (7) , 075012
A rotating permanent magnetic actuator for micropumping devices with magnetic nanofluids
In this study, a novel rotating permanent magnetic actuator (PMA) system is proposed to manipulate magnetic nanofluids to pump chemicals inside micro-sized channels with circular paths. The PMA consists of two permanent magnet pairs and a rotor-like structure. A semicircular-shaped microchannel with a square cross-section area is located at the top of the actuator in order to investigate the performance of the PMA. Fe 3 O 4 -water magnetic nanofluid is employed as a working fluid for the manipulation inside the microchannel. In the first stage of this work, a numerical survey is conducted to determine the most suitable angular distance between permanent magnets of a pair in terms of generated magnetic field form in the microchannel region and velocity distribution of magnetic nanofluid within the semicircular microchannel when the permanent magnets are stationary. Preliminary experiments are then carried out for the stationary permanent magnets to validate the predicted flow-field results. Performance tests for different PMA speeds (7.5–30 rpm) and particle concentrations (1%–3% by vol.) indicate that it is possible to manipulate the magnetic nanofluid inside the semicircular channel within a velocity range of 58.7–940 µ m s −1 , which corresponds to a flow rate range of 0.56–9.02 µ L min −1 . The results confirm that the proposed PMA system provides flow rate requirements in analytical microfluidic applications such as low flow drug delivery (1–10 µ L min −1 ), cell sorting (6.1 µ L min −1 ), and pathogen detection (3–5.83 µ L min −1 ).
- 1 September 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (11) , 112003
Effect of external magnetic field on thermal conductivity and viscosity of magnetic nanofluids: a review
- 1 September 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (11) , 112003
Effect of external magnetic field on thermal conductivity and viscosity of magnetic nanofluids: a review
- 1 March 2019
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 474, 199-206
Magnetic field dependent thermal conductivity measurements of magnetic nanofluids by 3ω method
- 1 March 2019
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 474, 199-206
Magnetic field dependent thermal conductivity measurements of magnetic nanofluids by 3ω method
- Top Cited Papers
- 1 February 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 82, 1664-1674
Effect of particle size on the viscosity of nanofluids: A review
- 1 February 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 82, 1664-1674
Top Cited PapersEffect of particle size on the viscosity of nanofluids: A review