Yafeng Guan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yafeng Guan has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
Kun Ding
Department of Instrumentation & Analytical Chemistry, Key Laboratory of Deep-sea Composition Detection Technology of Liaoning Province, Dalian Institute of Chemical Physics, CAS, 457 Zhongshan Road, Dalian 116023, China
14 shared publicationsDapeng Wu
CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences , 457 Zhongshan Road, Dalian 116023, P.R. China
13 shared publicationsXuhui Geng
Department of Instrumentation & Analytical Chemistry, CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, China
13 shared publicationsChunfeng Duan
CAS Key Laboratory of Separation Sciences for Analytical Chemistry Dalian Institute of Chemical Physics, Chinese Academy of Sciences Dalian China
11 shared publicationsHaijing Ning
Department of Instrumentation & Analytical Chemistry, Key Laboratory of Deep-sea Composition Detection Technology of Liaoning Province, Dalian Institute of Chemical Physics, CAS, 457 Zhongshan Road, Dalian 116023, China
6 shared publicationsMeng Shi
School of Chemistry and Chemical Engineering, Liaoning Normal University, Dalian, P.R. China
6 shared publications
Latest Publications
- 6 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (23) , 11993-11999
Underwater Gas Chromatograph-Quadrupole Mass Spectrometer for In Situ Analysis of VOCs in Deep Sea
An underwater gas chromatograph-quadrupole mass spectrometer (UGC-qMS) for in situ qualitative and quantitative analysis of volatile organic compounds (VOCs) in the deep sea was developed and evaluated. The UGC-qMS utilizes a membrane inlet, enrichment-thermal desorption, capillary column separation, and EI-quadrupole mass spectrometer detection. The overall dimension of the UGC-qMS is Φ220 mm × 960 mm, 100 kg in air, 58 kg in water, and the design maximum working depth is 6000 m. The UGC-qMS is powered by external power supply with average power consumption ≤ 100 W. The gas consumption is approximately 1 mL/min, supporting over 500 h of underwater operation in a single deployment. Limits of detection for ethane, propane, n-butane, benzene, toluene, and p-xylene under one enrichment process are 0.050, 0.041, 0.028, 0.20, 0.28, and 0.37 μg/L in water, respectively. The linearity of response is approximately 2 orders of magnitude. The UGC-qMS was tested at a depth of 4500 m in the South China Sea to validate its underwater feasibility. This work marks the first successful deployment of GC-MS for in situ analysis in deep sea. Covering a broad boiling point range from ethane to naphthalene, the UGC-qMS surpasses existing underwater in situ analytical devices in VOCs analysis, offering a powerful tool for deep-sea chemical exploration.
- 6 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (23) , 11993-11999
Underwater Gas Chromatograph-Quadrupole Mass Spectrometer for In Situ Analysis of VOCs in Deep Sea
An underwater gas chromatograph-quadrupole mass spectrometer (UGC-qMS) for in situ qualitative and quantitative analysis of volatile organic compounds (VOCs) in the deep sea was developed and evaluated. The UGC-qMS utilizes a membrane inlet, enrichment-thermal desorption, capillary column separation, and EI-quadrupole mass spectrometer detection. The overall dimension of the UGC-qMS is Φ220 mm × 960 mm, 100 kg in air, 58 kg in water, and the design maximum working depth is 6000 m. The UGC-qMS is powered by external power supply with average power consumption ≤ 100 W. The gas consumption is approximately 1 mL/min, supporting over 500 h of underwater operation in a single deployment. Limits of detection for ethane, propane, n-butane, benzene, toluene, and p-xylene under one enrichment process are 0.050, 0.041, 0.028, 0.20, 0.28, and 0.37 μg/L in water, respectively. The linearity of response is approximately 2 orders of magnitude. The UGC-qMS was tested at a depth of 4500 m in the South China Sea to validate its underwater feasibility. This work marks the first successful deployment of GC-MS for in situ analysis in deep sea. Covering a broad boiling point range from ethane to naphthalene, the UGC-qMS surpasses existing underwater in situ analytical devices in VOCs analysis, offering a powerful tool for deep-sea chemical exploration.
- 30 January 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1345, 343747
An underwater gas chromatograph for in-situ analysis of organics in deep-sea
- 30 January 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1345, 343747
An underwater gas chromatograph for in-situ analysis of organics in deep-sea
- 14 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10121-10126
A Miniaturized and Highly Sensitive “Windmill” Three-Channel Fluorescence Detector for Simultaneous Detection of Various Mycotoxins
A novel "windmill" three-channel light-emitting diode induced fluorescence detector (LED-IF) was proposed to maximize the excitation efficiency and fluorescence collection efficiency. Compared with the typical collinear arrangement, the fluorescence intensity of the three channels was increased by 7.85, 3.88, and 2.94 times, respectively. The compact shaping optical path was designed to obtain higher excitation efficiency and a lower background stray light effect caused by high divergence angle high-power ultraviolet (UV)-LEDs simultaneously, which increased the sensitivity of three channels by 4.6 to 5.7 times. It was found that using a photodiode (PD) with a flat window and a larger photosensitive surface can collect the Lambertian emission fluorescence in the flow cell more efficiently, increasing the signal-to-noise ratio of each channel 1.3 to 1.8 times. The limits of detection (LODs, 3 times peak-peak noise) of aflatoxin B2 (AFB2), ochratoxin (OTA), and zearalenone (ZEN) were 0.33, 1.80, and 28.2 ng/L, respectively. Finally, six mycotoxins were analyzed simultaneously by the detector coupling with HPLC. The results showed that the sensitivity of the detector was at the best level to date, which was better than that of the top commercial fluorescence detectors (FLDs). The developed detector has the advantages of having small volume, low cost, and long lifetime and being robust, which has wide application and market prospects.
- 14 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10121-10126
A Miniaturized and Highly Sensitive “Windmill” Three-Channel Fluorescence Detector for Simultaneous Detection of Various Mycotoxins
A novel "windmill" three-channel light-emitting diode induced fluorescence detector (LED-IF) was proposed to maximize the excitation efficiency and fluorescence collection efficiency. Compared with the typical collinear arrangement, the fluorescence intensity of the three channels was increased by 7.85, 3.88, and 2.94 times, respectively. The compact shaping optical path was designed to obtain higher excitation efficiency and a lower background stray light effect caused by high divergence angle high-power ultraviolet (UV)-LEDs simultaneously, which increased the sensitivity of three channels by 4.6 to 5.7 times. It was found that using a photodiode (PD) with a flat window and a larger photosensitive surface can collect the Lambertian emission fluorescence in the flow cell more efficiently, increasing the signal-to-noise ratio of each channel 1.3 to 1.8 times. The limits of detection (LODs, 3 times peak-peak noise) of aflatoxin B2 (AFB2), ochratoxin (OTA), and zearalenone (ZEN) were 0.33, 1.80, and 28.2 ng/L, respectively. Finally, six mycotoxins were analyzed simultaneously by the detector coupling with HPLC. The results showed that the sensitivity of the detector was at the best level to date, which was better than that of the top commercial fluorescence detectors (FLDs). The developed detector has the advantages of having small volume, low cost, and long lifetime and being robust, which has wide application and market prospects.
- 17 November 2023
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (1) , 63-70
A Simple and Low-cost Preliminary Quantification of Target Membrane Protein in Single Cells
To study the heterogeneity of target membrane proteins in single cells with cellular integrity, we proposed a simple and low-cost method to obtain the copy number of the membrane proteins. HeLa cells were labeled by FITC affinity bodies specifically targeting HER2 membrane proteins. The immunolabeled HeLa cells were quantified by a laboratory-built laser induced fluorescence detector. A series of fluorescent microspheres with known number of FITC molecules on the surface were used to establish the calibration curve, instead of the standard fluorescent solutions, because the morphology of the microspheres was similar to the cells, and the distribution of FITC on the spheres were similar to the distribution of HER2 on the HeLa. The fluorescence intensity of the cells was converted to the molecule number of HER2 by the calibration curve. A capillary electrophoresis system was used to drive the microspheres and cells through the detection window. The copy number of HER2 in HeLa cells ranged from 4,036 to 1,224,920 ± 100 (2.5–97.5%), and the median of copy numbers were 104,438 ± 100 per cell. This method for measuring low-abundance membrane proteins can be utilized for the initial exploration of proteomics in ordinary laboratories.
- 17 November 2023
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (1) , 63-70
A Simple and Low-cost Preliminary Quantification of Target Membrane Protein in Single Cells
To study the heterogeneity of target membrane proteins in single cells with cellular integrity, we proposed a simple and low-cost method to obtain the copy number of the membrane proteins. HeLa cells were labeled by FITC affinity bodies specifically targeting HER2 membrane proteins. The immunolabeled HeLa cells were quantified by a laboratory-built laser induced fluorescence detector. A series of fluorescent microspheres with known number of FITC molecules on the surface were used to establish the calibration curve, instead of the standard fluorescent solutions, because the morphology of the microspheres was similar to the cells, and the distribution of FITC on the spheres were similar to the distribution of HER2 on the HeLa. The fluorescence intensity of the cells was converted to the molecule number of HER2 by the calibration curve. A capillary electrophoresis system was used to drive the microspheres and cells through the detection window. The copy number of HER2 in HeLa cells ranged from 4,036 to 1,224,920 ± 100 (2.5–97.5%), and the median of copy numbers were 104,438 ± 100 per cell. This method for measuring low-abundance membrane proteins can be utilized for the initial exploration of proteomics in ordinary laboratories.
- 23 February 2023
- Published by Wiley in Phytochemical Analysis
- Vol. 34 (3) , 363-371
Online micro solid phase extraction coupled with ultra‐performance liquid chromatography–tandem mass spectrometry for trace analysis of endogenous plant hormones in Ulva linza
Objective: Ulva linza (L.) is a species of green algae widely distributed in China. We aimed to establish a sensitive online analytical method for quantification of endogenous phytohormones in fresh minute seaweed samples.Method: The method for quantification of endogenous plant hormones in fresh minute samples was developed based on a homemade online micro solid phase extraction (m‐SPE) system coupled with an ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) platform. The online m‐SPE instrument injected the eluent of m‐SPE directly onto the LC separation column, improving the utilization of samples and saving time. The m‐SPE column, of which the effective size was 9.6 × 2 mm i.d., was filled with 19 mg of C18 (10 μm).Results: Under optimized conditions, the limits of detection were 0.002–0.060 ng ml−1 for five plant hormones. The actual sample recoveries of phytohormones were 76.4–103.4% and the coefficients of variance were below 14.1%. The temporal distribution of these endogenous plant hormones of U. linza during different growth periods is described.Conclusion: The proposed online m‐SPE method was successfully applied to quantification of endogenous acidic and alkaline plant hormones in U. linza. It provides important information for the further study of the physiological and ecological effects of plant hormones in lower algal species.
- 23 February 2023
- Published by Wiley in Phytochemical Analysis
- Vol. 34 (3) , 363-371
Online micro solid phase extraction coupled with ultra‐performance liquid chromatography–tandem mass spectrometry for trace analysis of endogenous plant hormones in Ulva linza
Objective: Ulva linza (L.) is a species of green algae widely distributed in China. We aimed to establish a sensitive online analytical method for quantification of endogenous phytohormones in fresh minute seaweed samples.Method: The method for quantification of endogenous plant hormones in fresh minute samples was developed based on a homemade online micro solid phase extraction (m‐SPE) system coupled with an ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) platform. The online m‐SPE instrument injected the eluent of m‐SPE directly onto the LC separation column, improving the utilization of samples and saving time. The m‐SPE column, of which the effective size was 9.6 × 2 mm i.d., was filled with 19 mg of C18 (10 μm).Results: Under optimized conditions, the limits of detection were 0.002–0.060 ng ml−1 for five plant hormones. The actual sample recoveries of phytohormones were 76.4–103.4% and the coefficients of variance were below 14.1%. The temporal distribution of these endogenous plant hormones of U. linza during different growth periods is described.Conclusion: The proposed online m‐SPE method was successfully applied to quantification of endogenous acidic and alkaline plant hormones in U. linza. It provides important information for the further study of the physiological and ecological effects of plant hormones in lower algal species.
- 23 March 2022
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 50 (5) , 100084
Research highlight on CJAC—LED induced fluorescence detector
- 23 March 2022
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 50 (5) , 100084
Research highlight on CJAC—LED induced fluorescence detector
- 1 February 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1192, 339392
Peltier thermoelectric cooler improves both the signal-to-noise ratio and warm-up time of high-power LED induced fluorescence detector and application to aflatoxins
- 1 February 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1192, 339392
Peltier thermoelectric cooler improves both the signal-to-noise ratio and warm-up time of high-power LED induced fluorescence detector and application to aflatoxins
- 11 January 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (4) , 1969-1975
Enhancement of Chemiluminescence Intensity of S2* in Non-premixed Hydrogen Microjet Flame in the Photometric Detector for Sulfur Detection
A transparent quartz rod (q) placed vertically on top of a non-premixed hydrogen microjet flame in a flame photometric detector (qFPD) was developed and evaluated for sulfur detection. The microjet flame burned around the quartz rod because of Coanda effect, forming an extended downstream flame zone with a relatively low temperature between 550 and 650 °C, which is favorable to the formation of S2*. The emission intensity of S2* and the signal-to-noise ratio (SNR) of sulfur response were enhanced 2.6- and 2.1-fold, respectively. It was found that the quartz rod of diameter 4 mm with a tip shape of semicircle placed 6 mm above the nozzle yielded the highest SNR. The limits of detection (LOD) for seven kinds of tested sulfur-containing compounds of qFPD were 0.3–0.5 pg S s–1, which is 5–7 times better than that of commercially available FPD detectors (LOD: 1.6–2.8 pg S s–1). The selectivity of sulfur over carbon was 105 on qFPD when the SNR for the mass flow rate of S and C atoms was ∼3 times. It was the first time that a quartz rod was used vertically on top of a microjet hydrogen-rich flame in FPD to enhance the chemiluminescence of S2* and improve the LOD down to 0.3–0.5 pg S s–1.
- 11 January 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (4) , 1969-1975
Enhancement of Chemiluminescence Intensity of S2* in Non-premixed Hydrogen Microjet Flame in the Photometric Detector for Sulfur Detection
A transparent quartz rod (q) placed vertically on top of a non-premixed hydrogen microjet flame in a flame photometric detector (qFPD) was developed and evaluated for sulfur detection. The microjet flame burned around the quartz rod because of Coanda effect, forming an extended downstream flame zone with a relatively low temperature between 550 and 650 °C, which is favorable to the formation of S2*. The emission intensity of S2* and the signal-to-noise ratio (SNR) of sulfur response were enhanced 2.6- and 2.1-fold, respectively. It was found that the quartz rod of diameter 4 mm with a tip shape of semicircle placed 6 mm above the nozzle yielded the highest SNR. The limits of detection (LOD) for seven kinds of tested sulfur-containing compounds of qFPD were 0.3–0.5 pg S s–1, which is 5–7 times better than that of commercially available FPD detectors (LOD: 1.6–2.8 pg S s–1). The selectivity of sulfur over carbon was 105 on qFPD when the SNR for the mass flow rate of S and C atoms was ∼3 times. It was the first time that a quartz rod was used vertically on top of a microjet hydrogen-rich flame in FPD to enhance the chemiluminescence of S2* and improve the LOD down to 0.3–0.5 pg S s–1.