KCKing Chung

King Chung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


King Chung has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Extremely High Fitting Range and Dangerous Levels Permitted by the Current FDA Guidelines for OTC Hearing Aids and the Need to Consider RECDs

    by King Chung

    Background/Objective: One of the missions of the United States FDA is “protecting the public health by ensuring the safety, efficacy, and security of human and veterinary drugs, biological products.” The current guidelines for OTC hearing aids impose an output limit of 111 dB SPL for linear hearing aids and 117 dB SPL for compression hearing aids when measured using 90 dB SPL pure tones in a 2 cc coupler. This means that the sound pressure level at the ear drum at a frequency would be 111 or 117 dB SPL plus the real-ear-to-coupler difference (RECD) of the 2 cc coupler at the frequency. Methods: The maximum aidable hearing thresholds by hypothetical OTC-compression hearing aids that are compliant with the current FDA guidelines were explored using NAL-NL2 and DSLv5 prescriptive methods. The theoretical maximum permissible overall output levels in the ear canal were also calculated. Additionally, the fitting range of OTC-compression hearing aids with a maximum of 117 dB SPL output level at the ear drum was explored. Results: The current FDA guidelines allow OTC-compression hearing aids to provide sufficient gain and headroom to fit individuals with severe to profound hearing loss. In the presence of a loud wideband signal, the maximum overall output level can reach 164.5 dB SPL in the ear canal for an OTC-compression hearing aid with a bandwidth of 5657 Hz. When the maximum output levels are defined at the ear drum (i.e., the RECD is already considered), however, the fitting range is lowered to moderate hearing loss and the maximum overall output level is lowered by 10 dB. Conclusions: These findings identified potential regulatory vulnerability in the current FDA guidelines and suggest the need to take the measurement coupler and its corresponding RECDs into account when setting the guidelines for OTC hearing aids. Other alternative strategies to prevent potential abuses of the guidelines are also discussed.

  • Hearing Aid Loan Program for Hearing Loss at the End of Life

    by M. Courtney Hughes, Diane ScheckLong, King Chung

    This article describes a hearing aid loan program to provide free amplification devices for patients at the end of life to help them communicate more effectively at this critical time. It includes steps for establishing such a program, addressing challenges, and the role of the informal caregiver throughout the intervention. Healthcare professionals and social workers are encouraged to develop similar programs and use the information here as helpful suggestions to consider for their programs.

  • Fulbright: Opportunities for International Academic Exchange for Audiologists, SLPs

    by King Chung

    In a four-month journey, a research audiologist collaborated with the students and faculty at three Brazilian universities to provide hearing assessments for more than 1,200 children and adults, collect data on children’s hearing for a research program, test an automatic hearing test app, and teach.

  • Open Access

    Programa Saúde Auditiva do Escolar: Uma integração entre pesquisa e extensão

    by Thainá Ruth França de Farias, Aryelly Dayane da Silva Nunes, Victor Vasconcelos de Barros, Aline Roberta da Silva Xavier, Pierre Andrade Freire, Ricardo Fernando Arrais, Isabelle Ribeiro Barbosa, King Chung, Sheila Andreoli Balen

    A audição é um dos sentidos mais significativos para a comunicação humana, de tal maneira que a sua ausência acarreta efeitos negativos no bem-estar e na qualidade de vida da população envolvida. Diante desse contexto, esse estudo teve como objetivo relatar a experiência das atividades de pesquisa e de extensão desenvolvidas no Programa Saúde Auditiva do Escolar (PSAE), voltadas à educação em saúde auditiva. Foram realizados testes auditivos em uma comunidade escolar e verificadas as alterações auditivas mais prevalentes nessa população. Os principais achados foram obstrução de orelhas por cerume e relato do uso frequente de fones de ouvido. Os resultados encontrados contribuíram para a realização da ação de extensão “Ouvir por toda a vida: Dia Mundial da Audição 2020”, durante a qual foram realizadas quatro atividades por meio de recursos didáticos e lúdicos com essa população, sendo elas (1) “higienização das orelhas”, (2) “mapa do barulho”, (3) avaliação da intensidade do fone de ouvido com o auxílio da “Cocleannny”, (4) roda de conversa com os escolares com o auxílio da “Alexa” (personagem virtual) e (5) roda de conversa com os professores, sobre os problemas mais frequentes detectados. Todas as atividades apresentaram bons resultados, além de engajamento por parte da comunidade escolar, contribuindo para que os escolares possam tomar decisões mais adequadas quanto aos hábitos deletérios antes praticados: excessiva utilização do fone de ouvido e ruído durante as aulas. Palavras-chave: Transtornos da Audição; Estudantes; Educação em Saúde; Prevenção Primária School Auditory Health Program: an integration between research and extension Abstract: Hearing is one of the most significant meanings for human communication, so that its absence has adverse effects on the well-being and quality of life of the population involved. Given this context, this study aimed to report the experience of research and extension activities developed in the School Auditory Health Program (SAHP), focused on hearing health education. Hearing tests were carried out in a school community, and the most prevalent hearing disorders in this population were verified. The main findings were ear obstruction by cerumen and self-report of the frequent use of headphones. The results found contributed to the implementation of the extension action “Listening for life: World Hearing Day 2020”, during which four interactive activities were carried out through didactic and ludic resources with this population, which are (1) “ear cleaning,” (2) “noise map,” (3) earphone intensity assessment with the help of “Cocleanny,” (4) conversation with students with the help of the virtual character “Alexa” and (5) conversation with the teachers, all aiming to reduce the most frequent problems detected. All activities showed promising results and engagement by the school community, helping the students make more appropriate decisions regarding the harmful habits previously practiced, e. g. excessive use of the headset and noise during classes. Keywords: Hearing Disorders; Students; Health Education; Primary Prevention

  • Detection of hearing problems in Aboriginal and Torres strait islander children: a comparison between clinician-administered and self-administrated hearing tests

    by Kiri Mealings, Samantha Harkus, Brooke Flesher, Alea Meyer, King Chung, Harvey Dillon

    Objective: This study evaluated the agreement of self-administered tests with clinician-administered tests in detecting hearing loss and speech-in-noise deficits in Aboriginal & Torres Strait Islander children. Design: Children completed clinician-administered audiometry, self-administered automatic audiometry (AutoAud), clinician-administered Listening in Spatialised Noise – Sentences test and self-administered tablet-based hearing game Sound Scouts. Comparisons were made between tests to determine the agreement of the self-administered tests with clinician-administered tests in detecting hearing loss and speech-in-noise deficits. Study sample: Two hundred and ninety seven Aboriginal and Torres Strait Islander children aged 4–14 years from three schools. Results: Acceptable threshold differences of ≤5 dB between AutoAud and manual audiometry hearing thresholds were found for 88% of thresholds, with a greater agreement for older than for younger children. Consistent pass/fail results on the Sound Scouts speech-in-quiet measure and manual audiometry were found for 81% of children. Consistent pass/fail results on the Sound Scouts speech-in-noise measure and LiSN-S high-cue condition were found for 73% of children. Conclusions: This study shows good potential in using self-administered applications as initial tests for hearing problems in children. These tools may be especially valuable for children in remote locations and those from low socio-economic backgrounds who may not have easy access to healthcare.


  • Improving Cochlear Implant Performance in the Wind Through Spectral Masking Release: A Multi-microphone and Multichannel Strategy

    by King Chung

    Objectives: Adopting the omnidirectional microphone (OMNI) mode and reducing low-frequency gain are the two most commonly used wind noise reduction strategies in hearing devices. The objective of this study was to compare the effectiveness of these two strategies on cochlear implant users’ speech-understanding abilities and perceived sound quality in wind noise. We also examined the effectiveness of a new strategy that adopts the microphone mode with lower wind noise level in each frequency channel. Design: A behind-the-ear digital hearing aid with multiple microphone modes was used to record testing materials for cochlear implant participants. It was adjusted to have linear amplification, flat frequency response when worn on a Knowles Electronic Manikin for Acoustic Research to remove the head-related transfer function of the manikin and to mimic typical microphone characteristics of hearing devices. Recordings of wind noise samples and hearing-in-noise test sentences were made when the hearing aid was programmed to four microphone modes, namely (1) OMNI; (2) adaptive directional microphone (ADM); (3) ADM with low-frequency roll-off; and (4) a combination of omnidirectional and directional microphone (COMBO). Wind noise samples were recorded in an acoustically treated wind tunnel from 0° to 360° in 10° increment at a wind velocity of 4.5, 9.0, and 13.5 m/s when the hearing aid was worn on the manikin. Two wind noise samples recorded at 90° and 300° head angles at the wind velocity of 9.0 m/s were chosen to take advantage of the spectral masking release effects of COMBO. The samples were then mixed with the sentences recorded using identical settings. Cochlear implant participants listened to the speech-in-wind testing materials and they repeated the sentences and compared overall sound quality preferences of different microphone modes using a paired-comparison categorical rating paradigm. The participants also rated their preferences of wind-only samples. Results: COMBO yielded the highest speech recognition scores among the four microphone modes, and it was also preferred the most often, likely due to the reduction of spectral masking. The speech recognition scores generated using ADM with low-frequency roll-off were either equal to or lower than those obtained using ADM because gain reduction decreased not only the level of wind noise but also the low-frequency energy of speech. OMNI consistently yielded speech recognition scores lower than COMBO, and it was often rated as less preferable than other microphone modes, suggesting the conventional strategy to switch to the omnidirectional mode in the wind was undesirable. Conclusions: Neither adopting an OMNI nor reducing low-frequency gain generated higher speech recognition scores or higher sound quality ratings than COMBO. Adopting the microphone with lower wind noise level in different frequency channels can provide spectral masking release, and it is a more effective wind noise reduction strategy. The natural 6 dB/octave low-frequency roll-off of first-order directional microphones should be compensated when speech is present. Signal detection and decision rules for wind noise reduction applications are discussed in hearing devices with and without binaural transmission capability.