Katherine Anne Hollywood
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Katherine Anne Hollywood has a total of 273 co-authors. Here are the top co-authors by number of shared publications:
- Adam Hurlstone
The University of Manchester
12 shared publications - Adam McMahon
Wolfson Molecular Imaging Centre, Division of Informatics, Imaging and Data Sciences, School of Health Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, UK
12 shared publications Andrew P. Badrock
12 shared publicationsB. Ewa Snaar-Jagalska
12 shared publications- Christos Evangelou
Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
12 shared publications Duncan Forster
12 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (33) , 49151-49162
Expanding the Biocatalytic Toolbox: A Singular P450 Enzyme Efficiently Produces Diverse Pharmaceutical Metabolites
P450 BM3 is a natural fusion protein with a P450 domain fused to its necessary redox partner and capable of binding a range of fatty acids at high catalytic rates. The flexibility of the active site and catalytic efficiency have led to extensive research aimed at modifying substrate and product profiles for its utilization as a biocatalyst. The introduction of a double mutation (DM) at the base of the active site (A82F/F87V) allows the binding of a broad range of structurally diverse small molecules, including pharmaceutical drugs. Herein, we describe screening with an FDA-approved drug compound library, and the results exhibit the promiscuous nature of the DM BM3 variant. Of the 978 compounds screened; 59% of the library elicited UV–vis spectral shifts indicative of binding with a range of structurally diverse drugs. The interaction of the DM BM3 variant with a range of structurally diverse drugs, with a particular focus on the antidiabetic glitazone (thiazolidinedione) class, was investigated to observe ligand binding modes and metabolite production. BM3-derived metabolites were successfully produced and structurally elucidated for several structurally diverse drugs in the steroid, glitazone, meglitinide, terpene lactone, retinoid, and fibrate classes. The range of modifications performed includes some that are human P450-derived metabolites. Structural elucidation of the troglitazone-bound DM variant P450 domain shows an unusually close crystallographic interaction between the substrate and heme cofactor. We report here the use of the DM BM3 variant as a model for the main human metabolizing P450 enzymes CYP1A1, CYP2B6, CYP2C8, CYP2C9, and CYP3A4, as well as a biotechnological tool for the production of metabolites with diverse functionality.
- 12 August 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (33) , 49151-49162
Open AccessExpanding the Biocatalytic Toolbox: A Singular P450 Enzyme Efficiently Produces Diverse Pharmaceutical Metabolites
P450 BM3 is a natural fusion protein with a P450 domain fused to its necessary redox partner and capable of binding a range of fatty acids at high catalytic rates. The flexibility of the active site and catalytic efficiency have led to extensive research aimed at modifying substrate and product profiles for its utilization as a biocatalyst. The introduction of a double mutation (DM) at the base of the active site (A82F/F87V) allows the binding of a broad range of structurally diverse small molecules, including pharmaceutical drugs. Herein, we describe screening with an FDA-approved drug compound library, and the results exhibit the promiscuous nature of the DM BM3 variant. Of the 978 compounds screened; 59% of the library elicited UV–vis spectral shifts indicative of binding with a range of structurally diverse drugs. The interaction of the DM BM3 variant with a range of structurally diverse drugs, with a particular focus on the antidiabetic glitazone (thiazolidinedione) class, was investigated to observe ligand binding modes and metabolite production. BM3-derived metabolites were successfully produced and structurally elucidated for several structurally diverse drugs in the steroid, glitazone, meglitinide, terpene lactone, retinoid, and fibrate classes. The range of modifications performed includes some that are human P450-derived metabolites. Structural elucidation of the troglitazone-bound DM variant P450 domain shows an unusually close crystallographic interaction between the substrate and heme cofactor. We report here the use of the DM BM3 variant as a model for the main human metabolizing P450 enzymes CYP1A1, CYP2B6, CYP2C8, CYP2C9, and CYP3A4, as well as a biotechnological tool for the production of metabolites with diverse functionality.
- 25 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (26) , 19471-19481
Benchmarking Lipid Quantitation from Skin Swab Sebum-Rich Samples to Establish Mass Spectrometry-Based Diagnostic Methodology
Skin swab sampling provides an accessible, noninvasive method for collecting lipid-rich material from the skin surface, with growing potential for biomarker discovery and diagnostic testing. However, quantitative sebum analysis remains challenging because of variability in the amount collected and the complexity of the lipid matrix. This study evaluates the robustness of skin swab sampling for lipid analysis and the feasibility of quantifying skin-surface components using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Multiple reaction monitoring was used to assess analytical linearity, matrix effects, and recovery following established protocols for swab collection, storage, and extraction. Robust linearity was observed for both spiked isotope-labeled internal standards (IS) and endogenous lipids across concentrations of 0.15-550 ng/mL (R2 > 0.97). IS recovery varied between lipid classes, with consistent under-recovery. Although IS corrected for analytical variability during extraction and analysis, it could not fully account for differences in the amount of material collected. Endogenous lipids were, therefore, evaluated as normalization markers. Ratios between selected triacylglycerol (TG) species were highly conserved across samples, with coefficients of variation below 15% for TG 45:1/TG 47:1, TG 46:1/TG 48:1, and TG 47:1/TG 48:1. These ratios were stable across individuals and were independent of disease status. The reproducibility of TG recovery and stability of TG ratios suggest that endogenous lipid normalization can mitigate sampling and extraction variability. This approach provides a framework for improving quantitative reliability in skin swab lipidomics and represents a big step toward the development of reproducible mass spectrometry workflows for skin-swat-based biomarker studies.
- 25 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (26) , 19471-19481
Benchmarking Lipid Quantitation from Skin Swab Sebum-Rich Samples to Establish Mass Spectrometry-Based Diagnostic Methodology
Skin swab sampling provides an accessible, noninvasive method for collecting lipid-rich material from the skin surface, with growing potential for biomarker discovery and diagnostic testing. However, quantitative sebum analysis remains challenging because of variability in the amount collected and the complexity of the lipid matrix. This study evaluates the robustness of skin swab sampling for lipid analysis and the feasibility of quantifying skin-surface components using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Multiple reaction monitoring was used to assess analytical linearity, matrix effects, and recovery following established protocols for swab collection, storage, and extraction. Robust linearity was observed for both spiked isotope-labeled internal standards (IS) and endogenous lipids across concentrations of 0.15-550 ng/mL (R2 > 0.97). IS recovery varied between lipid classes, with consistent under-recovery. Although IS corrected for analytical variability during extraction and analysis, it could not fully account for differences in the amount of material collected. Endogenous lipids were, therefore, evaluated as normalization markers. Ratios between selected triacylglycerol (TG) species were highly conserved across samples, with coefficients of variation below 15% for TG 45:1/TG 47:1, TG 46:1/TG 48:1, and TG 47:1/TG 48:1. These ratios were stable across individuals and were independent of disease status. The reproducibility of TG recovery and stability of TG ratios suggest that endogenous lipid normalization can mitigate sampling and extraction variability. This approach provides a framework for improving quantitative reliability in skin swab lipidomics and represents a big step toward the development of reproducible mass spectrometry workflows for skin-swat-based biomarker studies.
- Open Access
Label-Free Determination of Chondroitin Sulphate from Microgram Quantities of Human Milk
Human milk contains structurally diverse glycans with key roles in shaping infant development, yet analytical constraints limit characterisation from low–volume samples. Glycosaminoglycans (GAGs), including chondroitin sulphate (CS), are understudied due to existing protocols requiring sample volumes of at least 5 mL and lengthy extraction steps prior to instrumental analysis. This study establishes a workflow for quantifying CS disaccharides from 25 μL of human milk, enabling analysis of samples previously inaccessible to GAG profiling, such as those collected as salvage samples from neonatal intensive care units. For CS quantification, the CS is first enzymatically depolymerised using chondroitinase ABC to release repeating disaccharide units. Matrix complexity is reduced via two rounds of acetonitrile–based protein and lipid precipitation. Disaccharides are separated by hydrophilic interaction liquid chromatography and detected using a Triple Quadrupole Mass Spectrometer, providing robust sensitivity for all CS disaccharides. Method development and validation were performed using pooled mature human milk from term infants. This workflow facilitates detection of all CS disaccharides, with low but reproducible recoveries for total CS. Low– and high– level spike recoveries were 41.3% (RSD r 7.5%, RSD r 15.9%) and 43.7% (RSD r 24.4%, RSD r 27.9%), respectively. Despite modest absolute accuracy, precision remained sufficient to make relative comparison of CS concentrations between samples. This method expands the analytical toolkit for human milk glycomics, enabling same day preparation and CS profiling from sample volumes that are 200 times smaller than prior work, supporting future investigations into GAG–mediated functions in early life.
Open AccessLabel-Free Determination of Chondroitin Sulphate from Microgram Quantities of Human Milk
Human milk contains structurally diverse glycans with key roles in shaping infant development, yet analytical constraints limit characterisation from low–volume samples. Glycosaminoglycans (GAGs), including chondroitin sulphate (CS), are understudied due to existing protocols requiring sample volumes of at least 5 mL and lengthy extraction steps prior to instrumental analysis. This study establishes a workflow for quantifying CS disaccharides from 25 μL of human milk, enabling analysis of samples previously inaccessible to GAG profiling, such as those collected as salvage samples from neonatal intensive care units. For CS quantification, the CS is first enzymatically depolymerised using chondroitinase ABC to release repeating disaccharide units. Matrix complexity is reduced via two rounds of acetonitrile–based protein and lipid precipitation. Disaccharides are separated by hydrophilic interaction liquid chromatography and detected using a Triple Quadrupole Mass Spectrometer, providing robust sensitivity for all CS disaccharides. Method development and validation were performed using pooled mature human milk from term infants. This workflow facilitates detection of all CS disaccharides, with low but reproducible recoveries for total CS. Low– and high– level spike recoveries were 41.3% (RSD r 7.5%, RSD r 15.9%) and 43.7% (RSD r 24.4%, RSD r 27.9%), respectively. Despite modest absolute accuracy, precision remained sufficient to make relative comparison of CS concentrations between samples. This method expands the analytical toolkit for human milk glycomics, enabling same day preparation and CS profiling from sample volumes that are 200 times smaller than prior work, supporting future investigations into GAG–mediated functions in early life.
- Open Access
- 21 November 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Skin swab sampling for quantitative mass spectrometry-based diagnostics
Skin swab sampling offers an accessible and non-invasive sample collection approach with applications in biomarker discovery and diagnostic testing. This study investigates the robustness of skin swab sampling and the feasibility of quantifying skin surface components using Liquid Chromatography-Mass Spectrometry. A semi-quantitative analysis and tandem mass spectrometry with Multiple Reaction Monitoring (MRM) for targeted quantification were used. Skin swabs were collected, stored and extracted following established protocols. Robust linearity is observed for both spiked isotope-labelled internal standards (IS) and endogenous lipids with the square of correlation coefficient (R2) >0.97 across a concentration range from 0.15-550 ng/mL. This confirms the potential for accurate quantification despite the complex lipid-rich matrix. Matrix effects, including both signal suppression and enhancement, were mitigated using targeted MRM analyses, which improved precision and reduced interference. Recovery of IS showed variability between lipid classes with consistent under-recovery. To address this, endogenous lipids were evaluated for use in normalization. Ratioed abundances of triglyceride pairs provide consistency across samples, with coefficient of variation values below 15% for pairs such as; TG 45:1 and TG 47:1, TG 46:1 and TG 48:1, and TG 47:1 and TG 48:1. These TG pairs provide a robust normalization framework to account for variation in sample collection and extraction, which will assist with reliable quantitation of variant features between individuals.
- 21 November 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessSkin swab sampling for quantitative mass spectrometry-based diagnostics
Skin swab sampling offers an accessible and non-invasive sample collection approach with applications in biomarker discovery and diagnostic testing. This study investigates the robustness of skin swab sampling and the feasibility of quantifying skin surface components using Liquid Chromatography-Mass Spectrometry. A semi-quantitative analysis and tandem mass spectrometry with Multiple Reaction Monitoring (MRM) for targeted quantification were used. Skin swabs were collected, stored and extracted following established protocols. Robust linearity is observed for both spiked isotope-labelled internal standards (IS) and endogenous lipids with the square of correlation coefficient (R2) >0.97 across a concentration range from 0.15-550 ng/mL. This confirms the potential for accurate quantification despite the complex lipid-rich matrix. Matrix effects, including both signal suppression and enhancement, were mitigated using targeted MRM analyses, which improved precision and reduced interference. Recovery of IS showed variability between lipid classes with consistent under-recovery. To address this, endogenous lipids were evaluated for use in normalization. Ratioed abundances of triglyceride pairs provide consistency across samples, with coefficient of variation values below 15% for pairs such as; TG 45:1 and TG 47:1, TG 46:1 and TG 48:1, and TG 47:1 and TG 48:1. These TG pairs provide a robust normalization framework to account for variation in sample collection and extraction, which will assist with reliable quantitation of variant features between individuals.
- Open Access
- 2 September 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Development and translation of a method of clinical utility for LC-MS/MS analysis to detect SARS-CoV-2 antigens from ONP swabs and saliva
During the COVID-19 pandemic, development of diagnostic tests was vital to chart the course and to reduce the impact of the infection. Continued testing and surveillance of vaccine escape will continue for years to come which presents an opportunity to integrate such testing into clinical biochemistry laboratories that form part of integrated healthcare testing. Here we describe a protocol for a targeted mass spectrometry based proteomic assay (COVIDCAP) developed to detect SARS-CoV-2 peptides from oro-nasopharyngeal swabs (ONP) and saliva. This uses novel SISCAPA antibodies bound to magnetic beads and subsequent analysis of captured and purified SARS-CoV-2 nucleocapsid (NCAP) peptides. The method involves immediate deactivation of the sample using an ethanolic solution. This simultaneously inactivates the virus and denatures viral proteins at sampling in contrast to the approach for RT-PCR testing, with benefits for the assay as well as for downstream processing. A plate-based preparation of the samples involving acetone precipitation followed by a short tryptic digestion and subsequent immunocapture allows LC-MS detection and quantification of peptides from the NCAP protein, in a 3-minute inject-to-inject assay with an LOD of 20 attomoles from starting sample. For 576 ONP swab samples taken as exemplars here, the sensitivity and specificity of this analysis is shown to be 97.0% and 96.6% respectively.
- 2 September 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessDevelopment and translation of a method of clinical utility for LC-MS/MS analysis to detect SARS-CoV-2 antigens from ONP swabs and saliva
During the COVID-19 pandemic, development of diagnostic tests was vital to chart the course and to reduce the impact of the infection. Continued testing and surveillance of vaccine escape will continue for years to come which presents an opportunity to integrate such testing into clinical biochemistry laboratories that form part of integrated healthcare testing. Here we describe a protocol for a targeted mass spectrometry based proteomic assay (COVIDCAP) developed to detect SARS-CoV-2 peptides from oro-nasopharyngeal swabs (ONP) and saliva. This uses novel SISCAPA antibodies bound to magnetic beads and subsequent analysis of captured and purified SARS-CoV-2 nucleocapsid (NCAP) peptides. The method involves immediate deactivation of the sample using an ethanolic solution. This simultaneously inactivates the virus and denatures viral proteins at sampling in contrast to the approach for RT-PCR testing, with benefits for the assay as well as for downstream processing. A plate-based preparation of the samples involving acetone precipitation followed by a short tryptic digestion and subsequent immunocapture allows LC-MS detection and quantification of peptides from the NCAP protein, in a 3-minute inject-to-inject assay with an LOD of 20 attomoles from starting sample. For 576 ONP swab samples taken as exemplars here, the sensitivity and specificity of this analysis is shown to be 97.0% and 96.6% respectively.
- Open Access
- 9 January 2024
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 51
Uncovering the fragmentation and separation characteristics of sophorolipid biosurfactants with LC-MS-ESI
The application of liquid chromatography and mass spectrometry (MS) is a challenging area of research for structural identification of sophorolipids, owing to the large number of possible variations in structure and limited knowledge on the separation and fragmentation characteristics of the variants. The aims of this work was to provide a comprehensive analysis of the expected characteristics and fragmentation patterns of a wide range of sophorolipid biosurfactant congeners, providing a methodology and process alongside freely available data to inform and enable future research of commercial or novel sophorolipids. Samples of acidic and lactonic sophorolipid standards were tested using reverse-phase ultra-high performance liquid chromatography and identified using electrospray ionization MS. 37 sophorolipid variants were identified and compared for their elution order and fragmentation pattern under MS/MS. The retention time of sophorolipids was increased by the presence of lactonization, unsaturation, chain length, and acetylation as hydrophobic interactions with the C18 stationary phase increased. A key finding that acidic forms can elute later than lactonic variants was obtained when the fatty acid length and unsaturation and acetylation are altered, in contradiction to previous literature statements. Fragmentation pathways were determined for lactonic and acidic variants under negative [M–H]− and positive [M+NH4]+ ionization, and unique patterns/pathways were identified to help determine the structural components present. The first publicly available database of chromatograms and MS2 spectra has been made available to aid in the identification of sophorolipid components and provide a reliable dataset to accelerate future research into novel sophorolipids and shorten the time to innovation. This article describes the process and challenges in identifying different structures of eco-friendly biosurfactants, providing a novel database to compare results.
- 9 January 2024
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 51
Open AccessUncovering the fragmentation and separation characteristics of sophorolipid biosurfactants with LC-MS-ESI
The application of liquid chromatography and mass spectrometry (MS) is a challenging area of research for structural identification of sophorolipids, owing to the large number of possible variations in structure and limited knowledge on the separation and fragmentation characteristics of the variants. The aims of this work was to provide a comprehensive analysis of the expected characteristics and fragmentation patterns of a wide range of sophorolipid biosurfactant congeners, providing a methodology and process alongside freely available data to inform and enable future research of commercial or novel sophorolipids. Samples of acidic and lactonic sophorolipid standards were tested using reverse-phase ultra-high performance liquid chromatography and identified using electrospray ionization MS. 37 sophorolipid variants were identified and compared for their elution order and fragmentation pattern under MS/MS. The retention time of sophorolipids was increased by the presence of lactonization, unsaturation, chain length, and acetylation as hydrophobic interactions with the C18 stationary phase increased. A key finding that acidic forms can elute later than lactonic variants was obtained when the fatty acid length and unsaturation and acetylation are altered, in contradiction to previous literature statements. Fragmentation pathways were determined for lactonic and acidic variants under negative [M–H]− and positive [M+NH4]+ ionization, and unique patterns/pathways were identified to help determine the structural components present. The first publicly available database of chromatograms and MS2 spectra has been made available to aid in the identification of sophorolipid components and provide a reliable dataset to accelerate future research into novel sophorolipids and shorten the time to innovation. This article describes the process and challenges in identifying different structures of eco-friendly biosurfactants, providing a novel database to compare results.
- Open Access
- 9 January 2024
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 51
Determining the accuracy and suitability of common analytical techniques for sophorolipid biosurfactants
To determine the performance of a sophorolipid biosurfactant production process, it is important to have accurate and specific analytical techniques in place. Among the most popular are the anthrone assay, gravimetric quantification (hexane:ethyl acetate extraction), and high-performance liquid chromatography (HPLC). The choice of analytical tool varies depending on cost, availability, and ease of use; however, these techniques have never been compared directly against one another. In this work, 75 fermentation broths with varying product/substrate concentrations were comprehensively tested with the 3 techniques and compared. HPLC–ultraviolet detection (198 nm) was capable of quantifying C18:1 subterminal hydroxyl diacetylated lactonic sophorolipid down to a lower limit of 0.3 g/L with low variability (R2 = .658) when compared to HPLC but could not quantify lower than 11.06 g/L, even when no sophorolipids were detected in the sample, highlighting the non-specificity of the method to co-extract non-sophorolipid components in the final gravimetric measure. The anthrone assay showed no linearity (R2 = .129) and was found to cross-react with media components (rapeseed oil, corn steep liquor, glucose), leading to consistent overestimation of sophorolipid concentration. The appearance of poor biomass separation during sample preparation with centrifugation was noted and resolved with a novel sample preparation method with pure ethanol. Extensive analysis and comparisons of the most common sophorolipid quantification techniques are explored and the limitations/advantages are highlighted. The findings provide a guide for scientists to make an informed decision on the suitable quantification tool that meets their needs, exploring all aspects of the analysis process from harvest, sample preparation, and analysis.
- 9 January 2024
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 51
Open AccessDetermining the accuracy and suitability of common analytical techniques for sophorolipid biosurfactants
To determine the performance of a sophorolipid biosurfactant production process, it is important to have accurate and specific analytical techniques in place. Among the most popular are the anthrone assay, gravimetric quantification (hexane:ethyl acetate extraction), and high-performance liquid chromatography (HPLC). The choice of analytical tool varies depending on cost, availability, and ease of use; however, these techniques have never been compared directly against one another. In this work, 75 fermentation broths with varying product/substrate concentrations were comprehensively tested with the 3 techniques and compared. HPLC–ultraviolet detection (198 nm) was capable of quantifying C18:1 subterminal hydroxyl diacetylated lactonic sophorolipid down to a lower limit of 0.3 g/L with low variability (R2 = .658) when compared to HPLC but could not quantify lower than 11.06 g/L, even when no sophorolipids were detected in the sample, highlighting the non-specificity of the method to co-extract non-sophorolipid components in the final gravimetric measure. The anthrone assay showed no linearity (R2 = .129) and was found to cross-react with media components (rapeseed oil, corn steep liquor, glucose), leading to consistent overestimation of sophorolipid concentration. The appearance of poor biomass separation during sample preparation with centrifugation was noted and resolved with a novel sample preparation method with pure ethanol. Extensive analysis and comparisons of the most common sophorolipid quantification techniques are explored and the limitations/advantages are highlighted. The findings provide a guide for scientists to make an informed decision on the suitable quantification tool that meets their needs, exploring all aspects of the analysis process from harvest, sample preparation, and analysis.
- Open Access
- 13 December 2023
- Published by American Chemical Society (ACS) in ChemRxiv
TD GC-MS and UPLC-MS methods to discover differentially expressed metabolites in sebum
Sebum is a lipid-rich biofluid produced by the sebaceous glands which are found in high abundance in areas where hair is present, along the neckline, the ‘T’-area of the face and on the upper back. Recent work has shown that sebum can be used in mass spectrometry-based metabolomics experimental workflows to identify metabolic changes that occur in individuals who are infected with the SARS-CoV-2 virus, Parkinson’s disease and REM-sleep Behavioural Disorders (RBD) when compared to healthy non-disease controls. We describe here standard operating protocols that can be used to analyse sebum that has been collected on gauze or cotton buds using two common and applicable hyphenated mass spectrometry (MS) methods, namely Thermal Desorption Gas Chromatography-Mass Spectrometry (TD GC-MS) and Ultra High Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS). For TD GC-MS the sebum samples are analysed directly with no sample preparation requirements and for UPLC-MS we detail the extraction process for sebum prior to data acquisition. The methods are demonstrated with results from sebum obtained from in-lab healthy volunteers to permit experiments in laboratories with access to either or both of the utilised chromatography-mass spectrometry methods.
- 13 December 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessTD GC-MS and UPLC-MS methods to discover differentially expressed metabolites in sebum
Sebum is a lipid-rich biofluid produced by the sebaceous glands which are found in high abundance in areas where hair is present, along the neckline, the ‘T’-area of the face and on the upper back. Recent work has shown that sebum can be used in mass spectrometry-based metabolomics experimental workflows to identify metabolic changes that occur in individuals who are infected with the SARS-CoV-2 virus, Parkinson’s disease and REM-sleep Behavioural Disorders (RBD) when compared to healthy non-disease controls. We describe here standard operating protocols that can be used to analyse sebum that has been collected on gauze or cotton buds using two common and applicable hyphenated mass spectrometry (MS) methods, namely Thermal Desorption Gas Chromatography-Mass Spectrometry (TD GC-MS) and Ultra High Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS). For TD GC-MS the sebum samples are analysed directly with no sample preparation requirements and for UPLC-MS we detail the extraction process for sebum prior to data acquisition. The methods are demonstrated with results from sebum obtained from in-lab healthy volunteers to permit experiments in laboratories with access to either or both of the utilised chromatography-mass spectrometry methods.
- Open Access
- 12 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Does Storage Post Sampling Influence the Stability of Sebum when used for Mass Spectrometry Metabolomics Analysis?
Sebum is a biofluid excreted by sebaceous glands in the skin. In recent years sebum has been shown to contain endogenous metabolites diagnostic of disease, with remarkable results for Parkinson’s Disease. Given that sebum sampling is facile and non-invasive, its potential for use in clinical biochemistry diagnostic assays should be explored including the parameters for standard operating procedures around collection, transport, and storage. To this aim we have here investigated the reproducibility of mass spectrometry data from sebum in relation to both storage temperature and length of storage. Sebum samples were collected from volunteers and stored for up to four weeks at a range of temperatures: ambient (circa 17 ˚C), -20 ˚C and -80 ˚C. Established extraction protocols were employed and the samples were analysed by two chromatographic mass spectrometry techniques and data investigated using PCA, PLS-DA and ANOVA. We cannot discriminate samples as a function of storage temperature or time stored in unsupervised analysis using data acquired via TD-GC-MS and LC-IM-MS, although the sampling of volatiles was susceptible to batch effects. This study indicates that the requirements for storage and transport of sebum samples that may be used in clinical assays are far less stringent than for liquid samples and indicate that sebum is suitable for remote and at home sampling prior to analysis.
- 12 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessDoes Storage Post Sampling Influence the Stability of Sebum when used for Mass Spectrometry Metabolomics Analysis?
Sebum is a biofluid excreted by sebaceous glands in the skin. In recent years sebum has been shown to contain endogenous metabolites diagnostic of disease, with remarkable results for Parkinson’s Disease. Given that sebum sampling is facile and non-invasive, its potential for use in clinical biochemistry diagnostic assays should be explored including the parameters for standard operating procedures around collection, transport, and storage. To this aim we have here investigated the reproducibility of mass spectrometry data from sebum in relation to both storage temperature and length of storage. Sebum samples were collected from volunteers and stored for up to four weeks at a range of temperatures: ambient (circa 17 ˚C), -20 ˚C and -80 ˚C. Established extraction protocols were employed and the samples were analysed by two chromatographic mass spectrometry techniques and data investigated using PCA, PLS-DA and ANOVA. We cannot discriminate samples as a function of storage temperature or time stored in unsupervised analysis using data acquired via TD-GC-MS and LC-IM-MS, although the sampling of volatiles was susceptible to batch effects. This study indicates that the requirements for storage and transport of sebum samples that may be used in clinical assays are far less stringent than for liquid samples and indicate that sebum is suitable for remote and at home sampling prior to analysis.
- Open Access
- 9 September 2023
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 145 (37) , 20672-20682
Mapping the Initial Stages of a Protective Pathway that Enhances Catalytic Turnover by a Lytic Polysaccharide Monooxygenase
Oxygenase and peroxygenase enzymes generate intermediates at their active sites which bring about the controlled functionalization of inert C-H bonds in substrates, such as in the enzymatic conversion of methane to methanol. To be viable catalysts, however, these enzymes must also prevent oxidative damage to essential active site residues, which can occur during both coupled and uncoupled turnover. Herein, we use a combination of stopped-flow spectroscopy, targeted mutagenesis, TD-DFT calculations, high-energy resolution fluorescence detection X-ray absorption spectroscopy, and electron paramagnetic resonance spectroscopy to study two transient intermediates that together form a protective pathway built into the active sites of copper-dependent lytic polysaccharide monooxygenases (LPMOs). First, a transient high-valent species is generated at the copper histidine brace active site following treatment of the LPMO with either hydrogen peroxide or peroxyacids in the absence of substrate. This intermediate, which we propose to be a CuII-(histidyl radical), then reacts with a nearby tyrosine residue in an intersystem-crossing reaction to give a ferromagnetically coupled (S = 1) CuII-tyrosyl radical pair, thereby restoring the histidine brace active site to its resting state and allowing it to re-enter the catalytic cycle through reduction. This process gives the enzyme the capacity to minimize damage to the active site histidine residues "on the fly" to increase the total turnover number prior to enzyme deactivation, highlighting how oxidative enzymes are evolved to protect themselves from deleterious side reactions during uncoupled turnover.
- 9 September 2023
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 145 (37) , 20672-20682
Open AccessMapping the Initial Stages of a Protective Pathway that Enhances Catalytic Turnover by a Lytic Polysaccharide Monooxygenase
Oxygenase and peroxygenase enzymes generate intermediates at their active sites which bring about the controlled functionalization of inert C-H bonds in substrates, such as in the enzymatic conversion of methane to methanol. To be viable catalysts, however, these enzymes must also prevent oxidative damage to essential active site residues, which can occur during both coupled and uncoupled turnover. Herein, we use a combination of stopped-flow spectroscopy, targeted mutagenesis, TD-DFT calculations, high-energy resolution fluorescence detection X-ray absorption spectroscopy, and electron paramagnetic resonance spectroscopy to study two transient intermediates that together form a protective pathway built into the active sites of copper-dependent lytic polysaccharide monooxygenases (LPMOs). First, a transient high-valent species is generated at the copper histidine brace active site following treatment of the LPMO with either hydrogen peroxide or peroxyacids in the absence of substrate. This intermediate, which we propose to be a CuII-(histidyl radical), then reacts with a nearby tyrosine residue in an intersystem-crossing reaction to give a ferromagnetically coupled (S = 1) CuII-tyrosyl radical pair, thereby restoring the histidine brace active site to its resting state and allowing it to re-enter the catalytic cycle through reduction. This process gives the enzyme the capacity to minimize damage to the active site histidine residues "on the fly" to increase the total turnover number prior to enzyme deactivation, highlighting how oxidative enzymes are evolved to protect themselves from deleterious side reactions during uncoupled turnover.