WZWeichao Zhang

Weichao Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Weichao Zhang has a total of 75 co-authors. Here are the top co-authors by number of shared publications:

  • Qun Yu

    Key Laboratory of Engineering Dielectrics and Its Application, Ministry of Education, Heilongjiang Provincial Key Laboratory of Dielectric Engineering, School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, China

    7 shared publications
  • Hong Zhao

    Ministry of Education, Key Laboratory of Engineering Dielectric and Its Application, Harbin University of Science and Technology, Harbin, China

    6 shared publications
  • Jixian Qiao

    National Key Laboratory of Electrical Materials and Insulation, Xian Jiaotong University, Xian, China

    5 shared publications
  • Qi-Chao Chen

    Key Laboratory of Engineering Dielectrics and Its Application, Ministry of Education, Heilongjiang Provincial Key Laboratory of Dielectric Engineering, School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, China

    5 shared publications
  • Wei-Feng Sun

    School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore

    4 shared publications
  • Zhongyuan Li

    Electric Power Research Institute, State Grid Heilongjiang Electric Power Co., Ltd., Harbin 150030, China

    4 shared publications

Latest Publications

  • DFB-FL/Interferometer Composite Partial Discharge Ultrasonic Detection System

    by Weichao Zhang, Bokai Zhang, Qibing Shao, Xuan Wang, Tao Zhang

  • Sensitivity Enhancement Packaging Technology for Fabry-Perot Partial Discharge Sensors

    by Weichao Zhang, He Zhu, Qun Yu, Bakut Timothy Didam, Shihu Yu, Xin Yu

  • Open Access

    Quasi-Distributed Partial Discharge Monitoring System with Remote Demodulation Based on DFB-FL/Interferometer Hybrid Sensing

    by Yuelan Lu, Qibing Shao, Qun Yu, Hongliang Zhang, Xiaolong Zhang, Huagang Zhan, Weichao Zhang

    In the field of long-distance partial discharge (PD) detection for submarine cables, there is an urgent need for a remote demodulation distributed detection technology deployable at multiple critical locations to overcome the limitations of single-point measurement. Factory joints of high-voltage submarine cables are high-risk components for PD, and long-distance fiber optic acoustic sensing technology holds the greatest potential for online monitoring. However, due to the viscoelasticity of the joint’s polymer insulation structure, sound propagation distance is severely limited, and non-multi-point measurement cannot achieve effective coverage of the measurement area. This paper proposes a quasi-distributed remote demodulation sensing system, in which both the fiber optic interferometer and the distributed feedback fiber laser (DFB-FL) serve as sensors, enabling highly sensitive quasi-distributed PD detection. The DFB-FL itself is highly sensitive to strain, and the multiple fiber coils formed by the interferometer arms are also highly sensitive to strain. Both can be modulated by the micro-strain induced by the acoustic field generated from PD in the polymer solid, producing phase shifts of the optical waves, which are then intrinsically demodulated by the interferometer system to extract the vibration signals caused by the discharge. Theoretical analysis shows that the sensitivity increases with the length of the unbalanced arm, with the upper limit constrained by laser coherence and optical attenuation; for the PD frequency band, the optimal unbalanced length is below 200 m—this design rule is applicable to on-chip interferometric sensors. The interferometer coils employ bend-insensitive fibers to suppress optical loss and improve fringe visibility. Meanwhile, three fiber coil configuration schemes are constructed to enhance the detection sensitivity to acoustic signals. Simulation results generate frequency response contour maps based on Young’s modulus, indicating that the solid-wound coil achieves the highest amplitude and the broadest bandwidth, with an optimal response frequency of approximately 50 kHz. Experimental results demonstrate that among the three structure types, the solid-wound coil also achieves the largest response ratio. Finally, in tests performed on a 220 kV submarine cable intermediate joint (with the system installed inside the metallic sheath), the minimum detectable discharge level in the DFB-FL region reached 6.75 pC, while that for the fiber coil reached 12.66 pC; when installed outside the metallic sheath, the minimum detectable discharge levels were 53.2 pC for the grating region and 89.6 pC for the fiber coil.

  • Multiphysics Coupling Analysis of HVDC Submarine Cable Joints Considering Dynamic Thermal Contact Resistance at the XLPE-SiR Interface

    by Linheng Li, Weichao Zhang, Qixin Yuan, Qun Yu

    The cross-linked polyethylene (XLPE) and silicone rubber (SiR) interface in prefabricated high-voltage direct current (HVDC) submarine cable joints is a critical weak point for thermal-electrical reliability. Conventional finite-element models often assume ideal thermal contact, thereby neglecting the dynamic evolution of thermal contact resistance (TCR) during operation. A steady-state thermal-resistance platform is used to characterize TCR over 0.11-1.0 MPa and 30-70 °C. The results show that, at elevated temperature and pressure, silicone grease laterally migrates (“squeeze-out”), leading to a non-monotonic TCR rebound. Accordingly, a dynamic TCR model is developed by augmenting contact-mechanics behavior with a rheology-based correction; parameters n and m quantify asperity deformation and grease extrusion, respectively. The model is then implemented as a thermal boundary condition in electro-thermal-mechanical multiphysics simulations. Considering dynamic TCR yields an interfacial temperature jump up to 9.6 °C under overload, increasing the conductor temperature relative to the ideal-contact case. Although the DC field redistribution is moderate, the temperature-driven reduction in breakdown strength markedly decreases the insulation safety margin (K), to 1/11 of that predicted by the ideal-contact assumption. The results highlight the importance of dynamic TCR in reliability assessment and offer guidance for insulation design and maintenance of HVDC accessories.


  • Multiparameter Detection Technology for Temperature and Partial Discharge in Liquid–Solid Composite Dielectrics Based on DFB-FL

    by Jixian Qiao, Chao Du, Weichao Zhang, Lisheng Zhong, Qibing Shao, Hong Zhao

    Traditional fiber optic sensors used for operation and maintenance inspection of power equipment face challenges in achieving multi-parameter detection due to factors such as sensitivity, safety, detection range, reusability, and difficulty in spatial separation from the demodulation system. Distributed feedback fiber laser (DFB-FL) exhibit extremely high detection sensitivity to strain due to its ultra-narrow emission linewidth. Moreover, its small size, high safety, excellent reusability, and independent demodulation systems can effectively solve the aforementioned problems. Based on the ultimate frequency noise and acoustic pressure model, the minimum measurable acoustic pressure of DFB-FL in the partial discharge (PD) acoustic emission frequency band is derived. The relationship between the center wavelength of DFB-FL and external temperature changes is explored based on the temperature sensitivity characteristics of DFB-FL. A multi-parameter detection system for PD acoustic emission and temperature based on DFB-FL is developed. The results of 80 kVA oil-immersed transformer temperature and PD detection show that the developed DFB-FL multi-parameter detection system can be effectively applied to measure the top oil temperature and hot spot temperature of oil-immersed transformers. Meanwhile, under the same PD ultrasonic excitation source, the average maximum response SNR of the system is 13.71 dB higher than that of a piezoelectric transducer.

  • Open Access

    Enhanced Stability in Partial Discharge Detection: A Differential Matching Approach for Fabry-Perot Interferometric Sensors

    by Weichao Zhang, Bakut Timothy Didam, Qun Yu

    This paper proposes a white-light path-matched differential interferometry (WL-PMDI) system combined with phase-generated carrier (PGC) demodulation for ultrasonic detection of partial discharges using extrinsic Fabry-Perot interferometric (EFPI) sensors. By cascading the EFPI sensing unit with a Mach-Zehnder interferometer (MZI) as a reference and leveraging the low-coherence characteristics of broadband light sources, the system transforms traditional intensity demodulation (which is susceptible to operating point drift) into stable phase demodulation. This approach fundamentally addresses the reliability challenges of EFPI sensors in long-term monitoring within complex environments, while incorporating PGC technology to achieve high-sensitivity dynamic signal extraction. Experimental results demonstrate that the system exhibits excellent linearity and maintains output signal fluctuations below 10% under temperature variations from 30°C to 90°C and static pressure interference, showcasing superior stability. In simulated transformer oil partial discharge detection, the system clearly resolves microsecond-scale acoustic pulses with a signal-to-noise ratio exceeding 20 dB, and maintains stable performance (with only 0.5% SNR degradation) during a 180-minute continuous operation test—significantly outperforming conventional intensity demodulation schemes that fail due to operating point drift. This study provides an effective technical solution for reliable, long-term online monitoring of high-voltage equipment insulation status in strong electromagnetic interference environments.

  • Open Access

    Research on Partial Discharge Acoustic Emission Sensing Using Fiber Optic Sagnac Interferometer Based on Shaft–Type Multi–Order Resonant Mode Coupling

    by Qichao Chen, Mengze Xu, Zhongyuan Li, Cong Chen, Weichao Zhang

    In response to the key issues of complex internal structure, significant attenuation of partial discharge (PD) ultrasound signal propagation, and low sensor sensitivity in large oil–immersed power transformers, this paper analyzes the multi–order resonant mode vibration characteristics of the shaft–type fiber optic ultrasound sensor core structure. The displacement distribution patterns of the core structure in both transverse and longitudinal resonant modes are clarified. A strategy using oblique fiber winding rings is proposed to eliminate the problems of strain cancellation and non–accumulation of displacement in transverse and longitudinal resonant modes, which are common in traditional fiber optic ultrasound sensors with parallel fiber windings. Furthermore, design principles are provided to enhance the coverage of the free end and the high–strain regions with semi–high symmetry, as well as the vector–integrated response suitable for multi–order modes. Experimental results show that, in typical PD model detection, the oblique winding sensor exhibits a more prominent response near the high–order resonances of the core, with a detection sensitivity approximately 2.5 times higher than that of the parallel winding structure, and an overall sensitivity at least 7.4 times greater than that of traditional Piezoelectric (PZT) sensors. This demonstrates that the fiber winding method is a key design parameter determining the acoustic–solid coupling efficiency and high sensitivity performance of shaft–type fiber optic interferometric PD sensors, providing a feasible path for high–reliability fiber optic sensing solutions for online monitoring of transformer partial discharges.