Anders Michael Fredenslund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anders Michael Fredenslund has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Charlotte Scheutz
DTU Sustain, Technical University of Denmark, Bygningstorvet, Building 115, DK-2800 Kongens Lyngby, Denmark
19 shared publications - Peter Kjeldsen
DTU Sustain, Technical University of Denmark, Bygningstorvet, Building 115, DK-2800 Kongens Lyngby, Denmark
11 shared publications Charlotte Scheutz
5 shared publications- Antonio Delre
Department of Environmental Engineering, Technical University of Denmark (DTU), Lyngby, Denmark
4 shared publications Jonas Nedenskov
3 shared publications- Louise Anne Klotz
McGill University
3 shared publications
Latest Publications
- 2 September 2026
- Published by Elsevier in Waste Management
- Vol. 226
Methane and nitrous oxide formation and emissions at a full-scale garden waste windrow composting facility in Denmark
- 2 September 2026
- Published by Elsevier in Waste Management
- Vol. 226
Methane and nitrous oxide formation and emissions at a full-scale garden waste windrow composting facility in Denmark
- Open Access
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
Full-scale garden waste windrow composting: Methane and nitrous oxide emission processes
Even though composting has been presented as an environmentally favourable alternative to landfilling, greenhouse gas emissions remain. Methane (CH4) and nitrous oxide (N2O) emissions from a Danish full-scale central composting facility were quantified in four measurement campaigns using flux chambers and the tracer gas dispersion method (TDM). Surface fluxes, gas composition and temperature were measured at all piles present at the site, including composting windrows and storage piles of mature compost or biofuel, consisting of the coarse fraction of shredded garden waste, which is sent for incineration with energy recovery. The highest CH4 fluxes (2.1 g CH4 h-1 m-2) and concentrations (18% v/v) were measured at windrows composed of shredded and sorted materials under active composting, and the highest N2O fluxes (0.045 g N2O h-1 m-2) were found at a windrow composed of shredded but unsorted materials. Storage piles (shredded garden waste, biofuels and mature compost) exhibited smaller but non-negligible CH4 and N2O emissions. Even though CH4 concentrations inside the windrows increased in line with pile age, due to the decrease in O2 availability, CH4 surface fluxes remained constant, thus indicating a potential increase in CH4 oxidation capacity in the windrows’ surface layers. Total facility CH4 and N2O emissions, measured using the TDM, were between 4.6-13 kg CH4 h-1 and 0.048-0.13 kg N2O h-1, respectively. Sub-facility emission measurements, including emissions from storage piles, are necessary to identify emission sources, develop efficient mitigation strategies and optimise windrow composting practices.
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFull-scale garden waste windrow composting: Methane and nitrous oxide emission processes
Even though composting has been presented as an environmentally favourable alternative to landfilling, greenhouse gas emissions remain. Methane (CH4) and nitrous oxide (N2O) emissions from a Danish full-scale central composting facility were quantified in four measurement campaigns using flux chambers and the tracer gas dispersion method (TDM). Surface fluxes, gas composition and temperature were measured at all piles present at the site, including composting windrows and storage piles of mature compost or biofuel, consisting of the coarse fraction of shredded garden waste, which is sent for incineration with energy recovery. The highest CH4 fluxes (2.1 g CH4 h-1 m-2) and concentrations (18% v/v) were measured at windrows composed of shredded and sorted materials under active composting, and the highest N2O fluxes (0.045 g N2O h-1 m-2) were found at a windrow composed of shredded but unsorted materials. Storage piles (shredded garden waste, biofuels and mature compost) exhibited smaller but non-negligible CH4 and N2O emissions. Even though CH4 concentrations inside the windrows increased in line with pile age, due to the decrease in O2 availability, CH4 surface fluxes remained constant, thus indicating a potential increase in CH4 oxidation capacity in the windrows’ surface layers. Total facility CH4 and N2O emissions, measured using the TDM, were between 4.6-13 kg CH4 h-1 and 0.048-0.13 kg N2O h-1, respectively. Sub-facility emission measurements, including emissions from storage piles, are necessary to identify emission sources, develop efficient mitigation strategies and optimise windrow composting practices.
- 24 March 2026
- Published by SAGE Publications in Waste Management & Research: The Journal for a Sustainable Circular Economy
- Vol. 44 (8) , 1222-1231
Methane and nitrous oxide emission factors from full-scale garden waste composting facilities
Bio-waste composting is environmentally favourable to landfilling; however, this practice has been shown to emit methane (CH 4 ) and nitrous oxide (N 2 O), both of which contribute to climate change. Measurement-based studies are necessary to quantify these emissions accurately, define composting best practices and monitor mitigation strategies. Composting practices in Denmark rely on open windrow composting, with 90% of facilities solely treating garden waste. We measured CH 4 and N 2 O emissions at three full-scale garden waste facilities and one farm in Denmark during four campaigns spread over the course of a whole year. Whole-site CH 4 emissions were measured using the tracer gas dispersion method, whereas N 2 O emissions were derived based on CH 4 to N 2 O ratios from flux chambers measurements and the whole-site CH 4 emissions. Whole-site CH 4 and N 2 O emissions ranged from 0.065 to 29.5 kg CH 4 h −1 , and from ⩽10 −4 to 1.1 kg N 2 O h −1 , respectively. Combining our measurements at 4 sites with measurements from previous studies at 8 other Danish sites, we derived emission factors for open windrow garden waste composting of 2.56 kg CH 4 /Mg waste wet weight (ww) and 0.054 kg N 2 O/Mg waste ww from 11 facilities and 1 farm storing shredded and sorted garden waste. This resulted in a notable improvement in the representativeness of these emission factors compared to those previously used in the Danish National Inventory Report (NIR), which were based on measurements performed 20 years ago at a single Danish composting facility. As a result of this study, the CH 4 emission factor was updated in the 2024 Danish NIR.
- 24 March 2026
- Published by SAGE Publications in Waste Management & Research: The Journal for a Sustainable Circular Economy
- Vol. 44 (8) , 1222-1231
Methane and nitrous oxide emission factors from full-scale garden waste composting facilities
Bio-waste composting is environmentally favourable to landfilling; however, this practice has been shown to emit methane (CH 4 ) and nitrous oxide (N 2 O), both of which contribute to climate change. Measurement-based studies are necessary to quantify these emissions accurately, define composting best practices and monitor mitigation strategies. Composting practices in Denmark rely on open windrow composting, with 90% of facilities solely treating garden waste. We measured CH 4 and N 2 O emissions at three full-scale garden waste facilities and one farm in Denmark during four campaigns spread over the course of a whole year. Whole-site CH 4 emissions were measured using the tracer gas dispersion method, whereas N 2 O emissions were derived based on CH 4 to N 2 O ratios from flux chambers measurements and the whole-site CH 4 emissions. Whole-site CH 4 and N 2 O emissions ranged from 0.065 to 29.5 kg CH 4 h −1 , and from ⩽10 −4 to 1.1 kg N 2 O h −1 , respectively. Combining our measurements at 4 sites with measurements from previous studies at 8 other Danish sites, we derived emission factors for open windrow garden waste composting of 2.56 kg CH 4 /Mg waste wet weight (ww) and 0.054 kg N 2 O/Mg waste ww from 11 facilities and 1 farm storing shredded and sorted garden waste. This resulted in a notable improvement in the representativeness of these emission factors compared to those previously used in the Danish National Inventory Report (NIR), which were based on measurements performed 20 years ago at a single Danish composting facility. As a result of this study, the CH 4 emission factor was updated in the 2024 Danish NIR.
- Open Access
- 4 September 2025
- Published by Elsevier in Waste Management
- Vol. 206, 115087
Design and establishment of a biofilter for treatment of manure methane emissions
- 4 September 2025
- Published by Elsevier in Waste Management
- Vol. 206, 115087
Open AccessDesign and establishment of a biofilter for treatment of manure methane emissions
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Comparison of liquid phase and remote sensing measurements of nitrous oxide emission from biological nitrogen removal at a wastewater treatment facility
Direct emission of the greenhouse gases methane and nitrous oxide (N2O) constitute a significant fraction of the overall carbon footprint of wastewater treatment. Measurement methods to identify emission sources and to quantify emissions are key in mitigating these direct emissions. Nitrous oxide is formed in biological nitrogen removal process units, which are the main source of N2O emission from wastewater treatment.Liquid phase sensors (LPS) have recently been developed and installed at various Danish wastewater treatment plants to measure N2O concentrations in the liquid phase of biological nitrogen removal tanks. These sensors can be used to implement adjustments on the operation of the plant (for example duration of aeration), which affects N2O emission. In addition, LPS can be utilized to calculate N2O emission through mass transfer modelling. However, there is a need for validation of liquid-based modelled emission rates against measurement methods, which measure direct N2O emission rates. In this study, emission rates determined by two remote sensing methods, the tracer gas dispersion method (TDM) and Eddy covariance method (EC) were compared to LPS derived N2O emission rates.TDM relies on continuous, controlled release of a gaseous tracer at the source combined with downwind measurements of concentration of target gas (N2O here) and tracer gas (often acetylene - C2H2). This method is well-established, validated, and has been used to quantify fugitive emissions from various sources such as landfills, composting plants, biogas plants, etc. EC is a stationary method, which relies on high-frequency measurements of N2O concentration and wind vector on a tower near the source. EC can be set up for continuous monitoring, while TDM as applied here is a discrete measurement method.In the study, N2O emission rates were measured over a period of 1.5 years at a relatively large wastewater treatment plant in the greater Copenhagen area. TDM measurements were conducted on 15 measurement days covering both periods of relatively high and low N2O emission rates. TDM measurements were compared to LPS derived emission rates, where N2O emission was measured using sensors in four of eight process units for biological nitrogen removal. Overall, daily average emission rates between approximately 0.38 and 13.4 kg N2O h-1 were measured. High emission rates of 120 kg N2O h-1 were observed on a day, where plant maintenance is believed to be the cause of unusual high emission. Emission rates from simultaneous TDM measurements and LPS derived values (n=43) showed good correlation (R2=0.70). On average, emission rates from TDM were 35% higher than LPS rates. The model implementation to derive LPS determined emission rates was further developed during the study, and the listed results were the final values after some correction. Several factors can explain the difference – including liquid sensor drift, which for the specific sensors tends towards lower N2O concentration readings than actual concentrations. Continuous EC measurements showed the same emission dynamics as measured by the liquid sensors located inside the footprint of the station.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessComparison of liquid phase and remote sensing measurements of nitrous oxide emission from biological nitrogen removal at a wastewater treatment facility
Direct emission of the greenhouse gases methane and nitrous oxide (N2O) constitute a significant fraction of the overall carbon footprint of wastewater treatment. Measurement methods to identify emission sources and to quantify emissions are key in mitigating these direct emissions. Nitrous oxide is formed in biological nitrogen removal process units, which are the main source of N2O emission from wastewater treatment.Liquid phase sensors (LPS) have recently been developed and installed at various Danish wastewater treatment plants to measure N2O concentrations in the liquid phase of biological nitrogen removal tanks. These sensors can be used to implement adjustments on the operation of the plant (for example duration of aeration), which affects N2O emission. In addition, LPS can be utilized to calculate N2O emission through mass transfer modelling. However, there is a need for validation of liquid-based modelled emission rates against measurement methods, which measure direct N2O emission rates. In this study, emission rates determined by two remote sensing methods, the tracer gas dispersion method (TDM) and Eddy covariance method (EC) were compared to LPS derived N2O emission rates.TDM relies on continuous, controlled release of a gaseous tracer at the source combined with downwind measurements of concentration of target gas (N2O here) and tracer gas (often acetylene - C2H2). This method is well-established, validated, and has been used to quantify fugitive emissions from various sources such as landfills, composting plants, biogas plants, etc. EC is a stationary method, which relies on high-frequency measurements of N2O concentration and wind vector on a tower near the source. EC can be set up for continuous monitoring, while TDM as applied here is a discrete measurement method.In the study, N2O emission rates were measured over a period of 1.5 years at a relatively large wastewater treatment plant in the greater Copenhagen area. TDM measurements were conducted on 15 measurement days covering both periods of relatively high and low N2O emission rates. TDM measurements were compared to LPS derived emission rates, where N2O emission was measured using sensors in four of eight process units for biological nitrogen removal. Overall, daily average emission rates between approximately 0.38 and 13.4 kg N2O h-1 were measured. High emission rates of 120 kg N2O h-1 were observed on a day, where plant maintenance is believed to be the cause of unusual high emission. Emission rates from simultaneous TDM measurements and LPS derived values (n=43) showed good correlation (R2=0.70). On average, emission rates from TDM were 35% higher than LPS rates. The model implementation to derive LPS determined emission rates was further developed during the study, and the listed results were the final values after some correction. Several factors can explain the difference – including liquid sensor drift, which for the specific sensors tends towards lower N2O concentration readings than actual concentrations. Continuous EC measurements showed the same emission dynamics as measured by the liquid sensors located inside the footprint of the station.
- Open Access
- 20 November 2024
- Published by Elsevier in Waste Management
- Vol. 191, 253-263
Assessment of whole-site methane emissions from anaerobic digestion plants: Towards establishing emission factors for various plant configurations
- 20 November 2024
- Published by Elsevier in Waste Management
- Vol. 191, 253-263
Open AccessAssessment of whole-site methane emissions from anaerobic digestion plants: Towards establishing emission factors for various plant configurations
- Open Access
- 8 April 2024
- Published by Elsevier in Atmospheric Environment
- Vol. 328
Fast horizontal radial plume mapping of N2O using open-path absorption spectroscopy with a quantum-cascade laser
- 8 April 2024
- Published by Elsevier in Atmospheric Environment
- Vol. 328
Open AccessFast horizontal radial plume mapping of N2O using open-path absorption spectroscopy with a quantum-cascade laser
- Open Access
- 9 May 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-29
Intercomparison of detection and quantification methods for methane emissions from the natural gas distribution network in Hamburg, Germany
In August and September 2020, three different measurement methods for quantifying methane (CH4) emission from leaks in urban gas distribution networks were applied and compared in Hamburg, Germany: the “mobile”, “tracer release” and “suction” methods. The mobile and tracer release methods determine emission rates to the atmosphere from measurements of CH4 mole fractions in the ambient air, and the tracer release method also includes measurement of a gaseous tracer. The suction method determines emission rates by pumping air out of the ground using soil probes that are placed above the suspected leak location. The quantitative intercomparison of the emission rates from the three methods at a small number of locations is challenging because of limitations of the different methods at different types of leak locations. The mobile method was designed to rapidly quantify the average or total emission rate of many gas leaks in a city, but it yields a large emission rate uncertainty for individual leak locations. Emission rates determined for individual leak locations with the tracer release technique are more precise because the simultaneous measurement of the tracer released at a known rate at the emission source eliminates many of the uncertainties encountered with the mobile method. Nevertheless, care must be taken to properly collocate the tracer release and the leak emission points to avoid biases in emission rate estimates. The suction method could not be completed or applied at locations with widespread subsurface CH4 accumulation, or due to safety measures, and this sampling bias may be associated with a bias towards leak locations with low emission rates. The leak locations where the suction method could not be applied were the biggest emitters as confirmed by the emission rate quantifications using mobile and tracer methods and an engineering method based on leak’s diameter, pipeline overpressure and depth at which the pipeline is buried. The corresponding sampling bias for the suction technique led to a low bias in derived emission rates in this study. It is important that future studies using the suction method account for any leaks not quantifiable with this method in order to avoid biases, especially when used to inform emission inventories.
- 9 May 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-29
Open AccessIntercomparison of detection and quantification methods for methane emissions from the natural gas distribution network in Hamburg, Germany
In August and September 2020, three different measurement methods for quantifying methane (CH4) emission from leaks in urban gas distribution networks were applied and compared in Hamburg, Germany: the “mobile”, “tracer release” and “suction” methods. The mobile and tracer release methods determine emission rates to the atmosphere from measurements of CH4 mole fractions in the ambient air, and the tracer release method also includes measurement of a gaseous tracer. The suction method determines emission rates by pumping air out of the ground using soil probes that are placed above the suspected leak location. The quantitative intercomparison of the emission rates from the three methods at a small number of locations is challenging because of limitations of the different methods at different types of leak locations. The mobile method was designed to rapidly quantify the average or total emission rate of many gas leaks in a city, but it yields a large emission rate uncertainty for individual leak locations. Emission rates determined for individual leak locations with the tracer release technique are more precise because the simultaneous measurement of the tracer released at a known rate at the emission source eliminates many of the uncertainties encountered with the mobile method. Nevertheless, care must be taken to properly collocate the tracer release and the leak emission points to avoid biases in emission rate estimates. The suction method could not be completed or applied at locations with widespread subsurface CH4 accumulation, or due to safety measures, and this sampling bias may be associated with a bias towards leak locations with low emission rates. The leak locations where the suction method could not be applied were the biggest emitters as confirmed by the emission rate quantifications using mobile and tracer methods and an engineering method based on leak’s diameter, pipeline overpressure and depth at which the pipeline is buried. The corresponding sampling bias for the suction technique led to a low bias in derived emission rates in this study. It is important that future studies using the suction method account for any leaks not quantifiable with this method in order to avoid biases, especially when used to inform emission inventories.
- Open Access
- 4 March 2021
- Published by Copernicus GmbH
Maximising climate protection through minimising gas leakage – the Danish biogas measurement programme
The Danish voluntary methane monitoring programme for agricultural biogas producing facilities was launched by the Danish Biogas Association in autumn, 2016. The Danish Biogas Association had set a san overall goal of reducing the total methane loss from Danish biogas and upgrading plants on a national level to less than 1% of production by 2020.The Danish Government has allocated approximately 1.3 million € to monitor and reduce methane emissions from the biogas sector in the period 2019-2020, based on previous experiences. The funds are used to administer this new programme, method testing, validation of measurement service providers and to provide partial funding for the participation of biogas plants. Also, the project includes recommendations to the Danish Energy Agency regarding use of measurements in regulation based on the results of the programme. The programme includes agricultural biogas plants (both farm-scale and centralized plants), industrial biogas plants and biogas plants treating sludge from wastewater treatment. The biogas plants provide partial funding. Three levels of own-funding are used depending on the magnitude of gas production. Large biogas plants pay a larger fraction of expenses than smaller plants. This was chosen to ensure participation of smaller facilities.At each biogas plant, two or more of the following actions are performed:1. Initial agreement on services and expectations2. Development of self-monitoring programme3. Leakage search and mitigation recommendations4. Quantification of methane loss using remote sensing5. Draft project of emission reduction initiativesActions 1 and 4 are mandatory for the participating biogas plants. The leakage search (Action 3) is performed using Optical Gas Imaging (OGI). Here, a measurement technician uses OGI to identify leakages both outdoors on tanks, pipes etc., and indoors. The report lists and illustrates leakages (through video documentation) and provides advise on mitigation actions were applicable. Even though OGI is not used quantitatively, the leaks are categorized as low, medium and high emission rates based on the operator’s assessment from the OGI videos.Quantification of the biogas plants total methane emission (Action 4) is done using a tracer gas dispersion method. This remote sensing method includes the controlled, continuous release of a tracer gas (C2H2 in this case) combined with downwind, cross-plume measurements of methane and tracer gas. This method is described in Scheutz and Fredenslund (2019). It has been used to quantify emissions from biogas plants in the previous voluntary programme as well as to measure fugitive emissions from other area sources such as landfills, composting facilities and wastewater treatment plants.About 60 plants have signed up and measurement and consultation activities are currently ongoing. The plants include about 35 manure-based biogas plants, 2 industrial biogas plants and 22 wastewater treatment plants. All activities are to be completed by the end of February, 2021.This presentation will include a short introduction to the programme, observed emission rates and emission factors, typical sources of methane emission, mitigation options, recommendations regarding regulation and economic factors such as expenses for the monitoring activities.ReferenceScheutz, C., Fredenslund, A.M. 2019. Total methane emission rates and losses from 23 biogas plants. Waste Management, 97, 38-46.
- 4 March 2021
- Published by Copernicus GmbH
Open AccessMaximising climate protection through minimising gas leakage – the Danish biogas measurement programme
The Danish voluntary methane monitoring programme for agricultural biogas producing facilities was launched by the Danish Biogas Association in autumn, 2016. The Danish Biogas Association had set a san overall goal of reducing the total methane loss from Danish biogas and upgrading plants on a national level to less than 1% of production by 2020.The Danish Government has allocated approximately 1.3 million € to monitor and reduce methane emissions from the biogas sector in the period 2019-2020, based on previous experiences. The funds are used to administer this new programme, method testing, validation of measurement service providers and to provide partial funding for the participation of biogas plants. Also, the project includes recommendations to the Danish Energy Agency regarding use of measurements in regulation based on the results of the programme. The programme includes agricultural biogas plants (both farm-scale and centralized plants), industrial biogas plants and biogas plants treating sludge from wastewater treatment. The biogas plants provide partial funding. Three levels of own-funding are used depending on the magnitude of gas production. Large biogas plants pay a larger fraction of expenses than smaller plants. This was chosen to ensure participation of smaller facilities.At each biogas plant, two or more of the following actions are performed:1. Initial agreement on services and expectations2. Development of self-monitoring programme3. Leakage search and mitigation recommendations4. Quantification of methane loss using remote sensing5. Draft project of emission reduction initiativesActions 1 and 4 are mandatory for the participating biogas plants. The leakage search (Action 3) is performed using Optical Gas Imaging (OGI). Here, a measurement technician uses OGI to identify leakages both outdoors on tanks, pipes etc., and indoors. The report lists and illustrates leakages (through video documentation) and provides advise on mitigation actions were applicable. Even though OGI is not used quantitatively, the leaks are categorized as low, medium and high emission rates based on the operator’s assessment from the OGI videos.Quantification of the biogas plants total methane emission (Action 4) is done using a tracer gas dispersion method. This remote sensing method includes the controlled, continuous release of a tracer gas (C2H2 in this case) combined with downwind, cross-plume measurements of methane and tracer gas. This method is described in Scheutz and Fredenslund (2019). It has been used to quantify emissions from biogas plants in the previous voluntary programme as well as to measure fugitive emissions from other area sources such as landfills, composting facilities and wastewater treatment plants.About 60 plants have signed up and measurement and consultation activities are currently ongoing. The plants include about 35 manure-based biogas plants, 2 industrial biogas plants and 22 wastewater treatment plants. All activities are to be completed by the end of February, 2021.This presentation will include a short introduction to the programme, observed emission rates and emission factors, typical sources of methane emission, mitigation options, recommendations regarding regulation and economic factors such as expenses for the monitoring activities.ReferenceScheutz, C., Fredenslund, A.M. 2019. Total methane emission rates and losses from 23 biogas plants. Waste Management, 97, 38-46.