Spencer Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Spencer Cheng has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Guimarães Hourneaux de Moura
Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
6 shared publications Diogo T. de Moura
3 shared publicationsEduardo Moura
3 shared publicationsPaulo Sakai
3 shared publications- Tomazo Franzini
Gastrointestinal Endoscopy Unit, Division of Gastroenterology, Hospital das Clínicas of the Faculty of Medicine of the University of São Paulo - HC/FMUSP, Sao Paulo, Brazil
3 shared publications Aureo Delgado
2 shared publications
Latest Publications
- 7 July 2023
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 118 (10) , 1871-1879
Pure Cut or Endocut for Biliary Sphincterotomy? A Multicenter Randomized Clinical Trial
INTRODUCTION: Adverse events (AE) after endoscopic retrograde cholangiopancreatography (ERCP) are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger PEP or bleeding. Therefore, this study evaluated the outcomes of 2 electric current modes used during biliary sphincterotomy. METHODS: From October 2019 to August 2021, consecutive patients with native papilla undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation. RESULTS: A total of 550 patients were randomized (272 pure cut and 278 endocut). The overall PEP rate was 4.0% and significantly higher in the endocut group (5.8% vs 2.2%, P = 0.034). Univariate analysis revealed >5 attempts (P = 0.004) and endocut mode (P = 0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (P = 0.005) and a trend for endocut mode as risk factors for PEP (P = 0.052). Intraprocedural bleeding occurred more often with pure cut (P = 0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with endocut (P = 0.047). There was no difference in perforation (P = 1.0) or infection (P = 0.4999) between the groups. DISCUSSION: Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCT assessing the impact of electric current on AE with overlapping preventive measures such as rectal nonsteroidal anti-inflammatory drugs and hyperhydration are needed. The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.
- 7 July 2023
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 118 (10) , 1871-1879
Pure Cut or Endocut for Biliary Sphincterotomy? A Multicenter Randomized Clinical Trial
INTRODUCTION: Adverse events (AE) after endoscopic retrograde cholangiopancreatography (ERCP) are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger PEP or bleeding. Therefore, this study evaluated the outcomes of 2 electric current modes used during biliary sphincterotomy. METHODS: From October 2019 to August 2021, consecutive patients with native papilla undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation. RESULTS: A total of 550 patients were randomized (272 pure cut and 278 endocut). The overall PEP rate was 4.0% and significantly higher in the endocut group (5.8% vs 2.2%, P = 0.034). Univariate analysis revealed >5 attempts (P = 0.004) and endocut mode (P = 0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (P = 0.005) and a trend for endocut mode as risk factors for PEP (P = 0.052). Intraprocedural bleeding occurred more often with pure cut (P = 0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with endocut (P = 0.047). There was no difference in perforation (P = 1.0) or infection (P = 0.4999) between the groups. DISCUSSION: Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCT assessing the impact of electric current on AE with overlapping preventive measures such as rectal nonsteroidal anti-inflammatory drugs and hyperhydration are needed. The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.
- 9 June 2023
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 97 (6) , AB687-AB688
PURE CUT OR ENDOCUT FOR BILIARY SPHINCTEROTOMY? A MULTICENTER RANDOMIZED CLINICAL TRIAL
- 9 June 2023
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 97 (6) , AB687-AB688
PURE CUT OR ENDOCUT FOR BILIARY SPHINCTEROTOMY? A MULTICENTER RANDOMIZED CLINICAL TRIAL
- Open Access
- 15 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (8) , 1424
Endoscopic Ultrasound View of Pneumatosis Cystoides Intestinalis
Pneumatosis cystoid intestinalis (PCI) is a rare condition, with a worldwide incidence of 0.3–1.2%. PCI is classified into primary (idiopathic) and secondary forms, with 15% and 85% of presentations, respectively. This pathology was associated with a wide variety of underlining etiologies to explain the abnormal accumulation of gas within the submucosa (69.9%), subserosa (25.5%), or both layers (4.6%). Many patients endure misdiagnosis, mistreatment, or even inadequate surgical exploration. In this case, a patient presented acute diverticulitis, after treatment, a control colonoscopy was performed that found multiple rounds and elevated lesions. To further study the subepithelial lesion (SEL), a colorectal endoscopic ultrasound (EUS) was performed with an overtube in the same procedure. For safe insertion of the curvilinear array EUS, an overtube with colonoscopy was positioned through the sigmoid as described by Cheng et al. The EUS evaluation evidenced air reverberation in the submucosal layer. The pathological analysis was consistent with PCI’s diagnosis. The diagnosis of PCI is usually made by colonoscopy (51.9%), surgery (40.6%), and radiological findings (10.9%). Although the diagnosis can be made by radiological studies, a colorectal EUS and colonoscopy can be made in the same section without radiation and with high precision. As it is a rare disease, there are not enough studies to define the best approach, although colorectal EUS should be preferred for a reliable diagnosis.
- 15 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (8) , 1424
Open AccessEndoscopic Ultrasound View of Pneumatosis Cystoides Intestinalis
Pneumatosis cystoid intestinalis (PCI) is a rare condition, with a worldwide incidence of 0.3–1.2%. PCI is classified into primary (idiopathic) and secondary forms, with 15% and 85% of presentations, respectively. This pathology was associated with a wide variety of underlining etiologies to explain the abnormal accumulation of gas within the submucosa (69.9%), subserosa (25.5%), or both layers (4.6%). Many patients endure misdiagnosis, mistreatment, or even inadequate surgical exploration. In this case, a patient presented acute diverticulitis, after treatment, a control colonoscopy was performed that found multiple rounds and elevated lesions. To further study the subepithelial lesion (SEL), a colorectal endoscopic ultrasound (EUS) was performed with an overtube in the same procedure. For safe insertion of the curvilinear array EUS, an overtube with colonoscopy was positioned through the sigmoid as described by Cheng et al. The EUS evaluation evidenced air reverberation in the submucosal layer. The pathological analysis was consistent with PCI’s diagnosis. The diagnosis of PCI is usually made by colonoscopy (51.9%), surgery (40.6%), and radiological findings (10.9%). Although the diagnosis can be made by radiological studies, a colorectal EUS and colonoscopy can be made in the same section without radiation and with high precision. As it is a rare disease, there are not enough studies to define the best approach, although colorectal EUS should be preferred for a reliable diagnosis.
- 14 April 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 01) , S150-S151
OUTCOMES AND RISK FACTORS ASSOCIATED WITH GASTROINTESTINAL BLEEDING AMONG PATIENTS WITH SEVERE COVID-19
Aims The coronavirus disease 2019 (COVID-19) caused by the novel coronavirus (SARS-CoV-2), most commonly associated with being a respiratory illness may manifest with multi-organ involvement, including the gastrointestinal (GI) system. Given the ongoing pandemic, there is an urgent need to understand the impact of GIB among a population of patients with COVID-19. Therefore, we sought to evaluate patients with severe COVID-19 and assess outcomes and risk factors associated with GIB. Methods This was a single-center cohort study of a quaternary hospital in São Paulo, Brazil. Following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement, we retrospectively analyzed a cohort of hospitalized patients with severe COVID-19 who were admitted to the ICU from March 2020 to May 2021. Comparison of demographis, symptoms, laboratory data, and clinical outcomes were compared between GIB vs non-GIB groups. Multivariable regression analyses were performed to evaluate risk factors related to GIB and critical care outcomes, including in-hospital mortality. Results A total of 285 critically ill patients with COVID-19 were evaluated [29.82% with GIB vs 70.18% without GIB]. Patients with GIB were found to have increased in-hospital mortality (65.88% vs 37.00%;p=0.0001) and length of hospitalization (37.44±30.02 vs 19.88±11.60 days;p<0.0001). On multivariable regression, obesity was a significant risk factor for GIB [OR 66.09 (95% CI 3.80-1151.00); p=0.004)] ([Table 1]). Conclusions In conclusion, patients with severe COVID-19 and GIB had a significantly longer duration of hospitalization and increased mortality compared to patients without GIB. Notably, obesity was found to vastly increase the risk of GIB. Publication Date: 14 April 2022 (online) © 2022. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 01) , S150-S151
OUTCOMES AND RISK FACTORS ASSOCIATED WITH GASTROINTESTINAL BLEEDING AMONG PATIENTS WITH SEVERE COVID-19
Aims The coronavirus disease 2019 (COVID-19) caused by the novel coronavirus (SARS-CoV-2), most commonly associated with being a respiratory illness may manifest with multi-organ involvement, including the gastrointestinal (GI) system. Given the ongoing pandemic, there is an urgent need to understand the impact of GIB among a population of patients with COVID-19. Therefore, we sought to evaluate patients with severe COVID-19 and assess outcomes and risk factors associated with GIB. Methods This was a single-center cohort study of a quaternary hospital in São Paulo, Brazil. Following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement, we retrospectively analyzed a cohort of hospitalized patients with severe COVID-19 who were admitted to the ICU from March 2020 to May 2021. Comparison of demographis, symptoms, laboratory data, and clinical outcomes were compared between GIB vs non-GIB groups. Multivariable regression analyses were performed to evaluate risk factors related to GIB and critical care outcomes, including in-hospital mortality. Results A total of 285 critically ill patients with COVID-19 were evaluated [29.82% with GIB vs 70.18% without GIB]. Patients with GIB were found to have increased in-hospital mortality (65.88% vs 37.00%;p=0.0001) and length of hospitalization (37.44±30.02 vs 19.88±11.60 days;p<0.0001). On multivariable regression, obesity was a significant risk factor for GIB [OR 66.09 (95% CI 3.80-1151.00); p=0.004)] ([Table 1]). Conclusions In conclusion, patients with severe COVID-19 and GIB had a significantly longer duration of hospitalization and increased mortality compared to patients without GIB. Notably, obesity was found to vastly increase the risk of GIB. Publication Date: 14 April 2022 (online) © 2022. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 22 November 2021
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 65 (2) , e80-e84
Colonoscopic Ultrasound-Guided Fine-Needle Aspiration Using a Curvilinear Array Transducer: A Single-Center Retrospective Cohort Study
BACKGROUND: Curvilinear array ultrasound transducers enable tissue sampling and have therapeutic capabilities. Nevertheless, colonic intubation and maneuvering with these transducers is technically challenging and is therefore typically limited to the rectosigmoid area. This retrospective cohort study aimed to evaluate the safety, feasibility, and diagnostic yield of colonoscopic ultrasound-guided fine-needle aspiration in deep colonic intubation. IMPACT OF INNOVATION: The impact of this innovation is to enable tissue sampling of colonic and extracolonic lesions guided by endoscopic ultrasound. TECHNOLOGY, MATERIALS, AND METHODS: Curvilinear array ultrasound is used in the evaluation of luminal and extraluminal colonic diseases. Thirteen patients underwent colonoscopic ultrasound with a curvilinear array ultrasound endoscope in a single center for subepithelial lesions, cancer staging, and extracolonic lesions from July 2015 to February 2021. Endosonography was performed using an Olympus EU-ME1 and GF-UCT 180 with a 5-12MHz curvilinear array transducer. The primary outcome was the percentage of patients who were successfully scanned with the endoscopic ultrasound. The secondary outcomes included the success rate of fine-needle aspiration, the diagnostic yield of the tissue samples, and the adverse events related to the procedure. PRELIMINARY RESULTS: A total of 13 female patients underwent colonoscopic ultrasound. All patients (100%, 13/13) were successfully scanned. Fine-needle aspiration was deemed necessary and successfully performed in 100% (5/5) of the patients. Tissue samples collected by fine-needle aspiration resulted in a diagnostic yield of 60%, and no adverse events resulted from this intervention. CONCLUSIONS: This study demonstrates the feasibility of performing colonoscopic ultrasound with a curvilinear array transducer. Fine-needle aspiration for subepithelial, colonic, and extracolonic lesions is feasible and safe in this setting with no adverse events reported in our study. FUTURE DIRECTIONS: Future research should be directed toward validating colonoscopic ultrasound with a curvilinear array transducer technique in prospective randomized trials. Studies evaluating the feasibility and safety of endoscopic ultrasound-guided interventions in the colon, such as abscess drainage and enteral anastomosis, should be considered.
- 22 November 2021
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 65 (2) , e80-e84
Colonoscopic Ultrasound-Guided Fine-Needle Aspiration Using a Curvilinear Array Transducer: A Single-Center Retrospective Cohort Study
BACKGROUND: Curvilinear array ultrasound transducers enable tissue sampling and have therapeutic capabilities. Nevertheless, colonic intubation and maneuvering with these transducers is technically challenging and is therefore typically limited to the rectosigmoid area. This retrospective cohort study aimed to evaluate the safety, feasibility, and diagnostic yield of colonoscopic ultrasound-guided fine-needle aspiration in deep colonic intubation. IMPACT OF INNOVATION: The impact of this innovation is to enable tissue sampling of colonic and extracolonic lesions guided by endoscopic ultrasound. TECHNOLOGY, MATERIALS, AND METHODS: Curvilinear array ultrasound is used in the evaluation of luminal and extraluminal colonic diseases. Thirteen patients underwent colonoscopic ultrasound with a curvilinear array ultrasound endoscope in a single center for subepithelial lesions, cancer staging, and extracolonic lesions from July 2015 to February 2021. Endosonography was performed using an Olympus EU-ME1 and GF-UCT 180 with a 5-12MHz curvilinear array transducer. The primary outcome was the percentage of patients who were successfully scanned with the endoscopic ultrasound. The secondary outcomes included the success rate of fine-needle aspiration, the diagnostic yield of the tissue samples, and the adverse events related to the procedure. PRELIMINARY RESULTS: A total of 13 female patients underwent colonoscopic ultrasound. All patients (100%, 13/13) were successfully scanned. Fine-needle aspiration was deemed necessary and successfully performed in 100% (5/5) of the patients. Tissue samples collected by fine-needle aspiration resulted in a diagnostic yield of 60%, and no adverse events resulted from this intervention. CONCLUSIONS: This study demonstrates the feasibility of performing colonoscopic ultrasound with a curvilinear array transducer. Fine-needle aspiration for subepithelial, colonic, and extracolonic lesions is feasible and safe in this setting with no adverse events reported in our study. FUTURE DIRECTIONS: Future research should be directed toward validating colonoscopic ultrasound with a curvilinear array transducer technique in prospective randomized trials. Studies evaluating the feasibility and safety of endoscopic ultrasound-guided interventions in the colon, such as abscess drainage and enteral anastomosis, should be considered.
- 1 June 2018
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 87 (6) , AB427
Mo1278 A COMPARISON OF THE EFFICIENCY OF 22G VERSUS 25G NEEDLES IN EUS-FNA FOR SOLID PANCREATIC MASS ASSESSMENT: A SYSTEMATIC REVIEW AND META-ANALYSIS
- 1 June 2018
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 87 (6) , AB427
Mo1278 A COMPARISON OF THE EFFICIENCY OF 22G VERSUS 25G NEEDLES IN EUS-FNA FOR SOLID PANCREATIC MASS ASSESSMENT: A SYSTEMATIC REVIEW AND META-ANALYSIS
- 1 June 2018
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 87 (6) , AB453
Mo1339 EUS-FNA OF PANCREATIC SOLID MASSES: A PROSPECTIVE RANDOMIZED TRIAL COMPARING SUCTION WITH SLOW PULL
- 1 June 2018
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 87 (6) , AB453
Mo1339 EUS-FNA OF PANCREATIC SOLID MASSES: A PROSPECTIVE RANDOMIZED TRIAL COMPARING SUCTION WITH SLOW PULL
- Open Access
- 28 April 2018
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 24 (16) , 1803-1811
Papillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial
Papillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial
- 28 April 2018
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 24 (16) , 1803-1811
Open AccessPapillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial
Papillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial
- 11 November 2017
- Published by Colegio Brasileiro de Cirurgia Digestiva in Arquivos Brasileiros de Cirurgia Digestiva Express
- Vol. 28 (Supl.5) , 593
COLEDOCODUODENOSTOMIA ECOGUIADA: RELATO DE CASO.
- 11 November 2017
- Published by Colegio Brasileiro de Cirurgia Digestiva in Arquivos Brasileiros de Cirurgia Digestiva Express
- Vol. 28 (Supl.5) , 593
COLEDOCODUODENOSTOMIA ECOGUIADA: RELATO DE CASO.