Kevin Pratt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kevin Pratt has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Douglas N. Paulson
Tristan Technologies, Inc., San Diego, CA, USA
4 shared publications Anthony Mascarenas
Tristan Technologies, Inc., 6191 Cornerstone Court East, Suite 107, San Diego, California 92121, USA
2 shared publications- Ethan Y. Cho
Department of Electrical and Computer Engineering, University of California, Riverside, Riverside, CA, USA
2 shared publications - James Christopher Edgar
Lurie Family Foundations MEG Imaging Center, Department of Radiology The Children's Hospital of Philadelphia Philadelphia Pennsylvania USA
2 shared publications - Jay LeFebvre
Department of Electrical and Computer Engineering, University of California Riverside , Riverside, California 92521
2 shared publications - Limin Sun
State Key Laboratory of Functional Materials of Informatics, CAS Center for Excellence in Superconducting Electronics (CENSE), Shanghai Institute of Microsystem and Information Technology (SIMIT), Chinese Academy of Sciences
2 shared publications
Latest Publications
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (7) , 1-3
Portable Solid Nitrogen Cooling System for High Transition Temperature Superconductive Electronics
In this work we present a miniature solid nitrogen cooling system designed for high-transition temperature (high-Tc) superconductor Josephson devices operating in the temperature range of 40 K to 55 K. The system utilizes a small fiberglass Dewar and an external pump to solidify nitrogen in thermal contact with a circuit board insert. Our cooling tests of two different Dewars with 100 mL and 200 mL capacity, reveal that the systems can hold at their lowest base temperature of 42 K for 1.2 hours and 45 K for 4.7 hours for the 100 mL and 200 mL Dewars respectively. This can provide a low power, low weight cooling solution for ultra-portable superconductive electronics and other cryogenic sensors.
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (7) , 1-3
Portable Solid Nitrogen Cooling System for High Transition Temperature Superconductive Electronics
In this work we present a miniature solid nitrogen cooling system designed for high-transition temperature (high-Tc) superconductor Josephson devices operating in the temperature range of 40 K to 55 K. The system utilizes a small fiberglass Dewar and an external pump to solidify nitrogen in thermal contact with a circuit board insert. Our cooling tests of two different Dewars with 100 mL and 200 mL capacity, reveal that the systems can hold at their lowest base temperature of 42 K for 1.2 hours and 45 K for 4.7 hours for the 100 mL and 200 mL Dewars respectively. This can provide a low power, low weight cooling solution for ultra-portable superconductive electronics and other cryogenic sensors.
- Open Access
- 1 October 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (10) , 105215
Series arrays of planar long Josephson junctions for high dynamic range magnetic flux detection
We investigated series arrays of closely spaced, planar long Josephson junctions for magnetic field transduction in Earth’s field, with a linear response and high dynamic range. The devices were fabricated from thin film high-temperature superconductor YBa2Cu3O7−δ (YBCO) thin films, using focused helium ion beam irradiation to create the Josephson barriers. Four series arrays, each consisting of several hundreds of long junctions, were fabricated and electrically tested. From fits of the current-voltage characteristics, we estimate the standard deviation in critical current to be around 25%. Voltage-magnetic field measurements exhibit a transfer function of 42 mV/mT and a linear response over a range of 303 μT at 71 K, resulting in a dynamic range of 124 dB.
- 1 October 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (10) , 105215
Open AccessSeries arrays of planar long Josephson junctions for high dynamic range magnetic flux detection
We investigated series arrays of closely spaced, planar long Josephson junctions for magnetic field transduction in Earth’s field, with a linear response and high dynamic range. The devices were fabricated from thin film high-temperature superconductor YBa2Cu3O7−δ (YBCO) thin films, using focused helium ion beam irradiation to create the Josephson barriers. Four series arrays, each consisting of several hundreds of long junctions, were fabricated and electrically tested. From fits of the current-voltage characteristics, we estimate the standard deviation in critical current to be around 25%. Voltage-magnetic field measurements exhibit a transfer function of 42 mV/mT and a linear response over a range of 303 μT at 71 K, resulting in a dynamic range of 124 dB.
- 1 May 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (5) , 055110
Versatile synchronized real-time MEG hardware controller for large-scale fast data acquisition
Versatile controllers for accurate, fast, and real-time synchronized acquisition of large-scale data are useful in many areas of science, engineering, and technology. Here, we describe the development of a controller software based on a technique called queued state machine for controlling the data acquisition (DAQ) hardware, continuously acquiring a large amount of data synchronized across a large number of channels (>400) at a fast rate (up to 20 kHz/channel) in real time, and interfacing with applications for real-time data analysis and display of electrophysiological data. This DAQ controller was developed specifically for a 384-channel pediatric whole-head magnetoencephalography (MEG) system, but its architecture is useful for wide applications. This controller running in a LabVIEW environment interfaces with microprocessors in the MEG sensor electronics to control their real-time operation. It also interfaces with a real-time MEG analysis software via transmission control protocol/internet protocol, to control the synchronous acquisition and transfer of the data in real time from >400 channels to acquisition and analysis workstations. The successful implementation of this controller for an MEG system with a large number of channels demonstrates the feasibility of employing the present architecture in several other applications.
- 1 May 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (5) , 055110
Versatile synchronized real-time MEG hardware controller for large-scale fast data acquisition
Versatile controllers for accurate, fast, and real-time synchronized acquisition of large-scale data are useful in many areas of science, engineering, and technology. Here, we describe the development of a controller software based on a technique called queued state machine for controlling the data acquisition (DAQ) hardware, continuously acquiring a large amount of data synchronized across a large number of channels (>400) at a fast rate (up to 20 kHz/channel) in real time, and interfacing with applications for real-time data analysis and display of electrophysiological data. This DAQ controller was developed specifically for a 384-channel pediatric whole-head magnetoencephalography (MEG) system, but its architecture is useful for wide applications. This controller running in a LabVIEW environment interfaces with microprocessors in the MEG sensor electronics to control their real-time operation. It also interfaces with a real-time MEG analysis software via transmission control protocol/internet protocol, to control the synchronous acquisition and transfer of the data in real time from >400 channels to acquisition and analysis workstations. The successful implementation of this controller for an MEG system with a large number of channels demonstrates the feasibility of employing the present architecture in several other applications.
- 1 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (9) , 094301
BabyMEG: A whole-head pediatric magnetoencephalography system for human brain development research
We developed a 375-channel, whole-head magnetoencephalography (MEG) system (“BabyMEG”) for studying the electrophysiological development of human brain during the first years of life. The helmet accommodates heads up to 95% of 36-month old boys in the USA. The unique two-layer sensor array consists of: (1) 270 magnetometers (10 mm diameter, ∼15 mm coil-to-coil spacing) in the inner layer, (2) thirty-five three-axis magnetometers (20 mm × 20 mm) in the outer layer 4 cm away from the inner layer. Additionally, there are three three-axis reference magnetometers. With the help of a remotely operated position adjustment mechanism, the sensor array can be positioned to provide a uniform short spacing (mean 8.5 mm) between the sensor array and room temperature surface of the dewar. The sensors are connected to superconducting quantum interference devices (SQUIDs) operating at 4.2 K with median sensitivity levels of 7.5 fT/√Hz for the inner and 4 fT/√Hz for the outer layer sensors. SQUID outputs are digitized by a 24-bit acquisition system. A closed-cycle helium recycler provides maintenance-free continuous operation, eliminating the need for helium, with no interruption needed during MEG measurements. BabyMEG with the recycler has been fully operational from March, 2015. Ongoing spontaneous brain activity can be monitored in real time without interference from external magnetic noise sources including the recycler, using a combination of a lightly shielded two-layer magnetically shielded room, an external active shielding, a signal-space projection method, and a synthetic gradiometer approach. Evoked responses in the cortex can be clearly detected without averaging. These new design features and capabilities represent several advances in MEG, increasing the utility of this technique in basic neuroscience as well as in clinical research and patient studies.
- 1 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (9) , 094301
BabyMEG: A whole-head pediatric magnetoencephalography system for human brain development research
We developed a 375-channel, whole-head magnetoencephalography (MEG) system (“BabyMEG”) for studying the electrophysiological development of human brain during the first years of life. The helmet accommodates heads up to 95% of 36-month old boys in the USA. The unique two-layer sensor array consists of: (1) 270 magnetometers (10 mm diameter, ∼15 mm coil-to-coil spacing) in the inner layer, (2) thirty-five three-axis magnetometers (20 mm × 20 mm) in the outer layer 4 cm away from the inner layer. Additionally, there are three three-axis reference magnetometers. With the help of a remotely operated position adjustment mechanism, the sensor array can be positioned to provide a uniform short spacing (mean 8.5 mm) between the sensor array and room temperature surface of the dewar. The sensors are connected to superconducting quantum interference devices (SQUIDs) operating at 4.2 K with median sensitivity levels of 7.5 fT/√Hz for the inner and 4 fT/√Hz for the outer layer sensors. SQUID outputs are digitized by a 24-bit acquisition system. A closed-cycle helium recycler provides maintenance-free continuous operation, eliminating the need for helium, with no interruption needed during MEG measurements. BabyMEG with the recycler has been fully operational from March, 2015. Ongoing spontaneous brain activity can be monitored in real time without interference from external magnetic noise sources including the recycler, using a combination of a lightly shielded two-layer magnetically shielded room, an external active shielding, a signal-space projection method, and a synthetic gradiometer approach. Evoked responses in the cortex can be clearly detected without averaging. These new design features and capabilities represent several advances in MEG, increasing the utility of this technique in basic neuroscience as well as in clinical research and patient studies.
- Open Access
- 16 October 2015
- Published by Frontiers Media SA in Frontiers in Neuroanatomy
- Vol. 9, 131
The maturation of auditory responses in infants and young children: a cross-sectional study from 6 to 59 months
Background: An understanding of the maturation of auditory cortex responses in typically developing infants and toddlers is needed to later identify auditory processing abnormalities in infants at risk for neurodevelopmental disorders. The availability of infant and young child magnetoencephalography (MEG) systems may now provide near optimal assessment of left and right hemisphere auditory neuromagnetic responses in young populations. To assess the performance of a novel whole-head infant MEG system, a cross-sectional study examined the maturation of left and right auditory cortex responses in children 6- to 50-months of age. Methods: Blocks of 1000Hz (1st and 3rd blocks) and 500Hz tones (2nd block) were presented while MEG data were recorded using an infant/young child biomagnetometer (Artemis 123). Data were obtained from 29 children (11 males; 6 months to 59 months). Latency measures were obtained for the first positive-to-negative evoked response waveform complex in each hemisphere. Latency and age associations as well as frequency and hemisphere latency differences were examined. For the 1000 Hz tone, measures of reliability were computed. Results: For the first response - a response with a ‘P2m’ topography - latencies decreased as a function of age. For the second response - a response with a ‘N2m’ topography - no N2m latency and age relationships were observed. A main effect of tone frequency showed earlier P2m responses for 1st 1000 Hz (150 ms) and 2nd 1000 Hz (148 ms) versus 500 Hz tones (162 ms). A significant main effect of hemisphere showed earlier N2m responses for 2nd 1000 Hz (226 ms) versus 1st 1000 Hz (241 ms) versus 500 Hz tones (265 ms). P2m and N2m interclass correlation coefficient latency findings were as follows: left P2m (0.72, p < 0.001), right P2m (0.84, p < 0.001), left N2m (0.77, p < 0.001), and right N2m (0.77, p < 0.01). Conclusions: Findings of strong age and latency associations, sensitivity to tone frequency, and good test-retest reliability support the viability of longitudinal infant MEG studies that include younger as well as older participants as well as studies examining auditory processing abnormalities in infants at risk for neurodevelopmental disorders.
- 16 October 2015
- Published by Frontiers Media SA in Frontiers in Neuroanatomy
- Vol. 9, 131
Open AccessThe maturation of auditory responses in infants and young children: a cross-sectional study from 6 to 59 months
Background: An understanding of the maturation of auditory cortex responses in typically developing infants and toddlers is needed to later identify auditory processing abnormalities in infants at risk for neurodevelopmental disorders. The availability of infant and young child magnetoencephalography (MEG) systems may now provide near optimal assessment of left and right hemisphere auditory neuromagnetic responses in young populations. To assess the performance of a novel whole-head infant MEG system, a cross-sectional study examined the maturation of left and right auditory cortex responses in children 6- to 50-months of age. Methods: Blocks of 1000Hz (1st and 3rd blocks) and 500Hz tones (2nd block) were presented while MEG data were recorded using an infant/young child biomagnetometer (Artemis 123). Data were obtained from 29 children (11 males; 6 months to 59 months). Latency measures were obtained for the first positive-to-negative evoked response waveform complex in each hemisphere. Latency and age associations as well as frequency and hemisphere latency differences were examined. For the 1000 Hz tone, measures of reliability were computed. Results: For the first response - a response with a ‘P2m’ topography - latencies decreased as a function of age. For the second response - a response with a ‘N2m’ topography - no N2m latency and age relationships were observed. A main effect of tone frequency showed earlier P2m responses for 1st 1000 Hz (150 ms) and 2nd 1000 Hz (148 ms) versus 500 Hz tones (162 ms). A significant main effect of hemisphere showed earlier N2m responses for 2nd 1000 Hz (226 ms) versus 1st 1000 Hz (241 ms) versus 500 Hz tones (265 ms). P2m and N2m interclass correlation coefficient latency findings were as follows: left P2m (0.72, p < 0.001), right P2m (0.84, p < 0.001), left N2m (0.77, p < 0.001), and right N2m (0.77, p < 0.01). Conclusions: Findings of strong age and latency associations, sensitivity to tone frequency, and good test-retest reliability support the viability of longitudinal infant MEG studies that include younger as well as older participants as well as studies examining auditory processing abnormalities in infants at risk for neurodevelopmental disorders.
- Open Access
- 1 January 2014
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 8, 99
Artemis 123: development of a whole-head infant and young child MEG system
Background: A major motivation in designing the new infant and child magnetoencephalography (MEG) system described in this manuscript is the premise that electrophysiological signatures (resting activity and evoked responses) may serve as biomarkers of neurodevelopmental disorders, with neuronal abnormalities in conditions such as autism spectrum disorder potentially detectable early in development. Whole-head MEG systems are generally optimized/sized for adults. Since magnetic field produced by neuronal currents decreases as a function of distance^2 and infants and young children have smaller head sizes, whole-head adult MEG systems do not provide optimal signal-to-noise in younger individuals. This spurred development of a whole-head infant and young child MEG system – Artemis 123. Methods: In addition to describing the instrument design, the focus of this manuscript is use of Artemis 123 to obtain auditory evoked and resting-state neuromagnetic data in young children. Data were collected from a 14-month female, an 18-month female, and a 48-month male. Phantom data are also provided to show localization accuracy. Results: Artemis 123 auditory data showed generalizability and reproducibility, with auditory responses observed in all participants. The auditory MEG measures were found to be manipulable, exhibiting sensitivity to tone frequency. Furthermore, there appeared to be a predictable sensitivity of evoked components to development, with latencies decreasing with age. Resting-state showed characteristic oscillatory activity. Finally, phantom data showed that dipole sources could be localized with an errorConclusions: Artemis 123 allows efficient recording of whole-head MEG in infants four years and younger. Future work will examine the feasibility of obtaining somatosensory and visual recordings in similar-age children as well as obtaining recordings from younger infants. Thus, Artemis 123 offers the promise of detecting earlier diagnostic signatures
- 1 January 2014
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 8, 99
Open AccessArtemis 123: development of a whole-head infant and young child MEG system
Background: A major motivation in designing the new infant and child magnetoencephalography (MEG) system described in this manuscript is the premise that electrophysiological signatures (resting activity and evoked responses) may serve as biomarkers of neurodevelopmental disorders, with neuronal abnormalities in conditions such as autism spectrum disorder potentially detectable early in development. Whole-head MEG systems are generally optimized/sized for adults. Since magnetic field produced by neuronal currents decreases as a function of distance^2 and infants and young children have smaller head sizes, whole-head adult MEG systems do not provide optimal signal-to-noise in younger individuals. This spurred development of a whole-head infant and young child MEG system – Artemis 123. Methods: In addition to describing the instrument design, the focus of this manuscript is use of Artemis 123 to obtain auditory evoked and resting-state neuromagnetic data in young children. Data were collected from a 14-month female, an 18-month female, and a 48-month male. Phantom data are also provided to show localization accuracy. Results: Artemis 123 auditory data showed generalizability and reproducibility, with auditory responses observed in all participants. The auditory MEG measures were found to be manipulable, exhibiting sensitivity to tone frequency. Furthermore, there appeared to be a predictable sensitivity of evoked components to development, with latencies decreasing with age. Resting-state showed characteristic oscillatory activity. Finally, phantom data showed that dipole sources could be localized with an errorConclusions: Artemis 123 allows efficient recording of whole-head MEG in infants four years and younger. Future work will examine the feasibility of obtaining somatosensory and visual recordings in similar-age children as well as obtaining recordings from younger infants. Thus, Artemis 123 offers the promise of detecting earlier diagnostic signatures
- 1 February 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (2) , 024301
BabySQUID: A mobile, high-resolution multichannel magnetoencephalography system for neonatal brain assessment
We developed a prototype of a mobile, high-resolution, multichannel magnetoencephalography (MEG) system, called babySQUID, for assessing brain functions in newborns and infants. Unlike electroencephalography, MEG signals are not distorted by the scalp or the fontanels and sutures in the skull. Thus, brain activity can be measured and localized with MEG as if the sensors were above an exposed brain. The babySQUID is housed in a moveable cart small enough to be transported from one room to another. To assess brain functions, one places the baby on the bed of the cart and the head on its headrest with MEG sensors just below. The sensor array consists of 76 first-order axial gradiometers, each with a pickup coil diameter of and a baseline of , in a high-density array with a spacing of center-to-center. The pickup coils are below the outer surface of the headrest. The short gap provides unprecedented sensitivity since the scalp and skull are thin (as little as altogether) in babies. In an electromagnetically unshielded room in a hospital, the field sensitivity at was . The noise was reduced from at using a reference cancellation technique and further to using a gradient common mode rejection technique. Although the residual environmental magnetic noise interfered with the operation of the babySQUID, the instrument functioned sufficiently well to detect spontaneous brain signals from babies with a signal to noise ratio (SNR) of as much as 7.6:1. In a magnetically shielded room, the field sensitivity was at and at without implementation of reference or gradient cancellation. The sensitivity was sufficiently high to detect spontaneous brain activity from a old baby with a SNR as much as 40:1 and evoked somatosensory responses with a bandwidth after as little as four averages. We expect that both the noise and the sensor gap can be reduced further by approximately half with a gain in SNR of about four. Thus, we conclude from the performance of the prototype that it should be feasible to improve the babySQUID to detect cortical activity in infants in real time with high spatial resolution.- 1 February 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (2) , 024301
BabySQUID: A mobile, high-resolution multichannel magnetoencephalography system for neonatal brain assessment
We developed a prototype of a mobile, high-resolution, multichannel magnetoencephalography (MEG) system, called babySQUID, for assessing brain functions in newborns and infants. Unlike electroencephalography, MEG signals are not distorted by the scalp or the fontanels and sutures in the skull. Thus, brain activity can be measured and localized with MEG as if the sensors were above an exposed brain. The babySQUID is housed in a moveable cart small enough to be transported from one room to another. To assess brain functions, one places the baby on the bed of the cart and the head on its headrest with MEG sensors just below. The sensor array consists of 76 first-order axial gradiometers, each with a pickup coil diameter of and a baseline of , in a high-density array with a spacing of center-to-center. The pickup coils are below the outer surface of the headrest. The short gap provides unprecedented sensitivity since the scalp and skull are thin (as little as altogether) in babies. In an electromagnetically unshielded room in a hospital, the field sensitivity at was . The noise was reduced from at using a reference cancellation technique and further to using a gradient common mode rejection technique. Although the residual environmental magnetic noise interfered with the operation of the babySQUID, the instrument functioned sufficiently well to detect spontaneous brain signals from babies with a signal to noise ratio (SNR) of as much as 7.6:1. In a magnetically shielded room, the field sensitivity was at and at without implementation of reference or gradient cancellation. The sensitivity was sufficiently high to detect spontaneous brain activity from a old baby with a SNR as much as 40:1 and evoked somatosensory responses with a bandwidth after as little as four averages. We expect that both the noise and the sensor gap can be reduced further by approximately half with a gain in SNR of about four. Thus, we conclude from the performance of the prototype that it should be feasible to improve the babySQUID to detect cortical activity in infants in real time with high spatial resolution.- 6 April 2004
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 17 (5) , S324-S327
High temperature superconductor dc SQUID micro-susceptometer for room temperature objects
- 6 April 2004
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 17 (5) , S324-S327
High temperature superconductor dc SQUID micro-susceptometer for room temperature objects