MTM. Joan Taylor

M. Joan Taylor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


M. Joan Taylor has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Synthesis and Identification of Biologically Active Mono-Labelled FITC-Insulin Conjugate

    by Tam Vu, M. Joan Taylor, Harprit Singh, Jay Bilmoria, Andrew Bottrill, Tarsem Sahota

    Fluorescently labelling proteins such as insulin have wide ranging applications in a pharmaceutical research and drug delivery. Human insulin (Actrapid®) was labelled with fluorescein isothiocyanate (FITC) and the synthesised conjugate identified using reverse phase high performance liquid chromatography (RP-HPLC) on a C18 column and a gradient method with mobile phase A containing 0.1% trifluoroacetic acid (TFA) in Millipore water and mobile phase B containing 90% Acetonitrile, 10% Millipore water and 0.1% TFA. Syntheses were carried out at varying reaction times between 4 and 20 h. Mono-labelled FITC-insulin conjugate was successfully synthesised with labelling at the B1 position on the insulin chain using a molar ratio of 2:1 (FITC:insulin) at a reaction time of 18 h and confirmed by electrospray mass spectroscopy. Reactions were studied across a pH range of 7–9.8 and the quantities switch from mono-labelled to di-labelled FITC-insulin conjugates at a reaction time of 2 h (2:1 molar ratio) at pH > 8. The conjugates isolated from the studies had biological activities in comparison to native insulin of 99.5% monoB1, 78% monoA1, 51% diA1B1 and 0.06% triA1B1B29 in HUVEC cells by examining AKT phosphorylation levels. MonoB1 FITC-insulin conjugate was also compared to native insulin by examining cell surface GLUT4 in C2C12 skeletal muscle cells. No significant difference in the cellular response was observed for monoB1 produced in-house compared to native insulin. Therefore mono-labelled FITC-insulin at the B1 position showed similar biological activity as native insulin and can potentially be used for future biomedical applications.


  • Glucose lowering strategies with insulin

    by M Joan Taylor, Krishan P Chauhan, Tarsem S Sahota

    People with type 1 diabetes must use insulin and a large fraction of those with type 2 condition also do so. Many therefore struggle with the unpredictable balancing of insulin dose with calorie intake and utility. A healthy pancreas makes meticulous adjustment on a continuous basis that present therapeutic insulin administration cannot match. However, much progress has been made to make it simpler to inject both background and fast-acting boost insulins with a view to better mimicking normal pancreatic output. The present fast insulins are reviewed with accent on the primary amino acid structures of the biosynthetic types that diffuse more quickly than regular insulin that associates in hexamers. This makes boost doses kinetically and clinically more effective, allowing people to inject better estimated boost and corrective doses. Formulation advances are discussed for their present and potential contributions. The newer slow-acting insulins are also described and compared, their advantage also being kinetic with a lower likelihood of inducing overnight hypoglycaemia when used optimally. Finally, the appreciation of the advantages of alternative routes of administration such as oral and peritoneal are included in this review because of the possibility of altering the hepatic to peripheral ratio, the reasons for which are more effective but less obesogenic insulin activity. The logistics of oral insulin are summarised in terms of the risks to the insulin structure, the facilitation of paracellular uptake at the apical surface and the paradoxically advantageous hepatic first pass. Other non-invasive routes are also included in the review.

  • Open Access

    Insulin Solution Stability and Biocompatibility with Materials Used for an Implantable Insulin Delivery Device Using Reverse Phase HPLC Methods

    by Dolly Jacob, M. Joan Taylor, Paul Tomlins, Tarsem Sahota

    Insulin (Humulin® R IU500) has been delivered from an implantable artificial pancreas in diabetic rats and pigs. The artificial pancreas which was implanted in the peritoneum was fabricated from several biocompatible materials such as polycarbonate, stainless steel, polyurethane, titanium and a polyurethane resin. The device also contains a glucose responsive smart gel which controls the diffusion of insulin dependent on the surrounding glucose environment. As the insulin reservoir is refillable and in contact with the device materials, assessing its biocompatibility with these various device component materials was conducted. Insulin can undergo chemical degradation mainly via a deamidation reaction on glutamine and asparagine residues rendering its biological hormone functionality. Two Reverse Phase High Performance Liquid Chromatography (RP-HPLC) methods were developed and validated for detection of insulin and degradant Asn A21 desamido insulin (method A) and insulin and degradant Asn B3 desamido insulin (method B). Material biocompatibility studies show that stainless steel and titanium are suitable for an implantable insulin delivery device design over a 31-day period. The use of polycarbonate and polyurethane could be considered if the insulin reservoir in the device was only to remain in the device for less than 11 days after which time there is a loss in cresol which acts in a protective capacity for insulin stability.


  • Open Access

    Thermoresponsive Gels

    by M. Joan Taylor, Paul Tomlins, Tarsem S. Sahota

    Thermoresponsive gelling materials constructed from natural and synthetic polymers can be used to provide triggered action and therefore customised products such as drug delivery and regenerative medicine types as well as for other industries. Some materials give Arrhenius-type viscosity changes based on coil to globule transitions. Others produce more counterintuitive responses to temperature change because of agglomeration induced by enthalpic or entropic drivers. Extensive covalent crosslinking superimposes complexity of response and the upper and lower critical solution temperatures can translate to critical volume temperatures for these swellable but insoluble gels. Their structure and volume response confer advantages for actuation though they lack robustness. Dynamic covalent bonding has created an intermediate category where shape moulding and self-healing variants are useful for several platforms. Developing synthesis methodology—for example, Reversible Addition Fragmentation chain Transfer (RAFT) and Atomic Transfer Radical Polymerisation (ATRP)—provides an almost infinite range of materials that can be used for many of these gelling systems. For those that self-assemble into micelle systems that can gel, the upper and lower critical solution temperatures (UCST and LCST) are analogous to those for simpler dispersible polymers. However, the tuned hydrophobic-hydrophilic balance plus the introduction of additional pH-sensitivity and, for instance, thermochromic response, open the potential for coupled mechanisms to create complex drug targeting effects at the cellular level.


  • Open Access

    Insulin pump users would not rule out using an implantable artificial pancreas

    by Mj Taylor, R Gregory, H Mitchell, M Alblihed, A Alsabih, P Tomlins, Ts Sahota

    The aim of this survey was to establish the limitations of open loop continuous subcutaneous insulin infusion (CSII) as perceived by current users of the technology, and to ascertain their interest in and requirements for a non‐electronic implantable closed loop insulin pump, INSmart, currently under development for the treatment of type 1 diabetes. INSmart has been surgically implanted in the peritoneum in animal models and continuously restored normoglycaemia. A bottom‐up survey design was used to determine both positive and negative experiences of patients currently using CSII to define the performance characteristics they would require from a non‐electronic, implantable closed loop insulin pump. A total of 360 insulin pump users completed the survey. All respondents had type 1 diabetes, were predominantly from English‐speaking countries and had been diagnosed before age 34 years. Most had well controlled blood glucose (BG) according to their self‐reported HbA 1c results. They reported a reduction in this value after transferring to CSII from multi‐dose injections. However, 70% of pump users had more than three hypoglycaemic episodes per week. Eighty percent reported self‐measured BG values >10mmol/L three or more times per month; 94% of respondents considered a (non‐electronic implantable) closed loop insulin pump would make their BG management easier and improve their quality of life. The majority of respondents felt there were still many disadvantages to current external insulin pumps such as their constant visible presence, rotation of insertion sites and skin inflammation. These shortfalls could be overcome by a device, such as INSmart, that provides a relatively instant feedback mechanism for controlling insulin release due to its proposed location in the peritoneal cavity. Copyright © 2014 John Wiley & Sons.


  • Open Access

    New technologies in insulin delivery

    by Mj Taylor, Ts Sahota

    The electronic age is bringing advances in the treatment of diabetes, and this is important because the complications of diabetes remain despite the availability of effective therapeutic tools such as insulin. These developments focus on the need to deliver accurately timed and sized doses for predicted blood glucose levels.In this review, blood monitoring methods are discussed since, although the chemistry remains based on the enzymic oxidation of glucose, the display, storage and manipulation of data have transformed recently to engage with smartphone users. Continuous glucose monitoring sensing (CGMS) types are described along with an appreciation of the shortcomings of sensor technology. The discussion includes responses to other barriers to CGMS use for reducing the HbA1c value safely so that hypoglycaemia can be avoided. The newer pumps and the emergence of the minimalised patch pumps and patch pens are described. This includes the moves to attract more type 2 users to pump use, addresses the perceived obtrusiveness noted by younger users, and reviews the obstacles to rolling out pump use more widely in the UK. Penultimately, after reference to islet implants, the combination of the continuous sensing and conventional pump strategies to form a closed loop system is described, including a summary of the electronic algorithms and the clinical performance of systems in research settings. The review closes with an explanation of how other closed loop systems have been developed including the peritoneal Medtronic and the DiaPort and a smart gel, non‐electronic design. Copyright © 2013 John Wiley & Sons.


  • Glucose-sensitive gel rheology of dextran-concanavalin A mixtures suitable for self-regulating insulin delivery

    by M. Joan Taylor, Sangeeta Tanna, Tarsem S. Sahota

    Aqueous concentrated plain mixtures of dextran and concanavalin A (con A) were examined for their rheological response to glucose for comparison with previously studied partially photopolymerized acrylic derivatives. Non-destructive oscillatory tests were undertaken within the linear viscoelastic range to examine the relationship between the rheometry and the stoichiometry of the interactive materials and to examine rheological parameters as affected by molecular weight, component ratio, temperature and glucose concentrations between 0 and 1% w/w. These simple formulations were studied at 1 and 10 Hz at 0.5% strain at both 20 and 37°C. A second simplified rheological test was undertaken to demonstrate gel-sol reversibility and to produce a measure of equilibria created between these gels and glucose solutions with which they are in contact. This mimics the conditions in which the gel acts as a responsive gateway in the insulin delivery device. It proved that the gels equilibrate with glucose solutions, rather than indiscriminately removing glucose. This is important in terms of producing a delivery device that can respond in a reversible, glucose concentration-dependent manner. The method used for this is capable of relative values only but provides information not obtainable from conventional rheometry.