Omid Nematollahi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Omid Nematollahi has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad R. Sedaghat
Department of Otolaryngology–Head and Neck Surgery University of Cincinnati College of Medicine Cincinnati Ohio USA
3 shared publications - Mehdi Jahangiri
Energy and Environment Research Center, ShK.C., Islamic Azad University, Shahrekord, Iran
3 shared publications Kyung Chun Kim
2 shared publicationsMahdi Nili-Ahmadabadi
2 shared publications- Mohammad Karimi Firozjaei
College of Management, University of Tehran, Tehran 14179-35840, Iran
2 shared publications Mohammad Reza Assari
2 shared publications
Latest Publications
- Top Cited Papers
- 1 December 2019
- Published by Elsevier in Renewable Energy
- Vol. 143, 958-973
A risk-based multi-criteria spatial decision analysis for solar power plant site selection in different climates: A case study in Iran
- 1 December 2019
- Published by Elsevier in Renewable Energy
- Vol. 143, 958-973
Top Cited PapersA risk-based multi-criteria spatial decision analysis for solar power plant site selection in different climates: A case study in Iran
- 5 October 2019
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 16 (15) , 1422-1435
An optimization of energy cost of clean hybrid solar-wind power plants in Iran
Given the available capacities in Iran in terms of wind and solar renewable energies and regarding the fact that, to achieve a high economic growth, Iran needs to rise its power generation capacity, as well as considering that Iran suffers from severe shortage of water sources and necessarily needs to produce electricity without consuming water, this study aimed to find the lowest cost of energy generation by hybrid solar-wind system in 103 stations in Iran, using data taken from NASA and HOMER. Since building sector accounts for 45% of energy consumption in Iran, our purpose was to supply the electricity of an off-grid residential building. Results revealed that there is a high potential for using solar and wind renewable energies in Iran, so that the lowest and highest percentages of using renewables were recorded at Darab with 87% and Jask stations with 100% usage. Furthermore, the highest and lowest price per kWh of power generated were associated with a solar-diesel generator-battery system at Darab station with a price of $0.75/kWh and a wind-diesel generator-battery system at Bandarabbass station with a price of $0.586/kWh. Authors hope these results could play an effective role in development of using renewable energies in Iran.
- 5 October 2019
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 16 (15) , 1422-1435
An optimization of energy cost of clean hybrid solar-wind power plants in Iran
Given the available capacities in Iran in terms of wind and solar renewable energies and regarding the fact that, to achieve a high economic growth, Iran needs to rise its power generation capacity, as well as considering that Iran suffers from severe shortage of water sources and necessarily needs to produce electricity without consuming water, this study aimed to find the lowest cost of energy generation by hybrid solar-wind system in 103 stations in Iran, using data taken from NASA and HOMER. Since building sector accounts for 45% of energy consumption in Iran, our purpose was to supply the electricity of an off-grid residential building. Results revealed that there is a high potential for using solar and wind renewable energies in Iran, so that the lowest and highest percentages of using renewables were recorded at Darab with 87% and Jask stations with 100% usage. Furthermore, the highest and lowest price per kWh of power generated were associated with a solar-diesel generator-battery system at Darab station with a price of $0.75/kWh and a wind-diesel generator-battery system at Bandarabbass station with a price of $0.586/kWh. Authors hope these results could play an effective role in development of using renewable energies in Iran.
- Open Access
- 1 June 2019
- Published by Elsevier in Chinese Journal of Aeronautics
- Vol. 32 (6) , 1367-1379
Effects of coarse riblets on air flow structures over a slender delta wing using particle image velocimetry
- 1 June 2019
- Published by Elsevier in Chinese Journal of Aeronautics
- Vol. 32 (6) , 1367-1379
Open AccessEffects of coarse riblets on air flow structures over a slender delta wing using particle image velocimetry
- 13 February 2019
- Published by Taylor & Francis in International Journal of Remote Sensing
- Vol. 40 (13) , 5230-5260
An evaluation of energy balance parameters, and the relations between topographical and biophysical characteristics using the mountainous surface energy balance algorithm for land (SEBAL)
Energy balance parameters are very important in various applications such as energy global cycle, environment, climatic change monitoring, weather forecast, agriculture. The present study evaluates the influence of topographical conditions on the amount of downward shortwave radiation (SWD) of the surface, as well as the relation between surface Net radiation with biophysical characteristics and region’s land use’s. For this purpose, Landsat images, Digital Elevation Model (DEM), and a set of sample points have been used. To calculate the downward shortwave radiation and Net radiation fluxes, it has employed the mountainous SEBAL algorithm. Greenness, Brightness, Wetness, Normalization Difference Built-up Index (NDBI), Normalization Difference Vegetation Index (NDVI) and Albedo parameters considered as surface biophysical characteristics. Brightness, NDBI and Albedo information shows the percentage of impervious surfaces while Greenness and NDVI information is related to vegetation percentage and Wetness information concerns water-related rates as well as the wetness of the soil, plant, and built-up lands. Statistical analysis has been used to study the relationship between different parameters. Results show that the slope is the most influential topographical parameters on the amount of SWD of the surface. There is a reverse relation between the variants of SWD of the surface, and the slope of the surface, in second-degree polynomial form with a Pearson’s correlation coefficient (r) of 0.82. North aspect receive the minimum SWD average with a 681 W m–2 while flat lands receive the maximum SWD average with a 783 W m–2. Areas with the highest elevation, lowest slope, and flatlands, receive the highest SWD. Built-up lands have the lowest Net radiation flux average with a 595 W m–2 while water has the highest Net radiation flux average with a 761 W m–2. Net radiation flux is directly related with NDVI, Greenness and Wetness parameters, while it is reversely related to NDBI, Albebo and Brightness with a high r.
- 13 February 2019
- Published by Taylor & Francis in International Journal of Remote Sensing
- Vol. 40 (13) , 5230-5260
An evaluation of energy balance parameters, and the relations between topographical and biophysical characteristics using the mountainous surface energy balance algorithm for land (SEBAL)
Energy balance parameters are very important in various applications such as energy global cycle, environment, climatic change monitoring, weather forecast, agriculture. The present study evaluates the influence of topographical conditions on the amount of downward shortwave radiation (SWD) of the surface, as well as the relation between surface Net radiation with biophysical characteristics and region’s land use’s. For this purpose, Landsat images, Digital Elevation Model (DEM), and a set of sample points have been used. To calculate the downward shortwave radiation and Net radiation fluxes, it has employed the mountainous SEBAL algorithm. Greenness, Brightness, Wetness, Normalization Difference Built-up Index (NDBI), Normalization Difference Vegetation Index (NDVI) and Albedo parameters considered as surface biophysical characteristics. Brightness, NDBI and Albedo information shows the percentage of impervious surfaces while Greenness and NDVI information is related to vegetation percentage and Wetness information concerns water-related rates as well as the wetness of the soil, plant, and built-up lands. Statistical analysis has been used to study the relationship between different parameters. Results show that the slope is the most influential topographical parameters on the amount of SWD of the surface. There is a reverse relation between the variants of SWD of the surface, and the slope of the surface, in second-degree polynomial form with a Pearson’s correlation coefficient (r) of 0.82. North aspect receive the minimum SWD average with a 681 W m–2 while flat lands receive the maximum SWD average with a 783 W m–2. Areas with the highest elevation, lowest slope, and flatlands, receive the highest SWD. Built-up lands have the lowest Net radiation flux average with a 595 W m–2 while water has the highest Net radiation flux average with a 761 W m–2. Net radiation flux is directly related with NDVI, Greenness and Wetness parameters, while it is reversely related to NDBI, Albebo and Brightness with a high r.
- 1 October 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 173, 37-45
Experimental study of the effect of brazed compact metal-foam evaporator in an organic Rankine cycle performance: Toward a compact ORC
- 1 October 2018
- Published by Elsevier in Energy Conversion and Management
- Vol. 173, 37-45
Experimental study of the effect of brazed compact metal-foam evaporator in an organic Rankine cycle performance: Toward a compact ORC
- 1 October 2016
- Published by Elsevier in Renewable Energy
- Vol. 96, 295-304
Improvement of ventilation and heat transfer in Shavadoon via numerical simulation: A traditional HVAC system
- 1 October 2016
- Published by Elsevier in Renewable Energy
- Vol. 96, 295-304
Improvement of ventilation and heat transfer in Shavadoon via numerical simulation: A traditional HVAC system
- 1 May 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 58, 1357-1365
Clearness index predicting using an integrated artificial neural network (ANN) approach
- 1 May 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 58, 1357-1365
Clearness index predicting using an integrated artificial neural network (ANN) approach
- Top Cited Papers
- 1 February 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 54, 1172-1181
Energy demands and renewable energy resources in the Middle East
- 1 February 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 54, 1172-1181
Top Cited PapersEnergy demands and renewable energy resources in the Middle East
- 1 March 2015
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 7 (2) , 023123
Techno-economical assessment of renewable energies integrated with fuel cell for off grid electrification: A case study for developing countries
One of the development parameters of each country is the accessibility of its different regions to energy resources, especially electrical energy. Therefore, construction of new power plants is inevitable. Nevertheless, limited fossil fuel energy resources and environmental pollutant emissions further proves the necessity toward renewable energy use. To overcome intermittent nature of renewable energies such as solar and wind, development of hybrid energy systems has been proposed. In this study, the feasibility of wind and solar renewable energies was investigated for Khorramabad city as an example of a city in a developing country using HOMER (hybrid optimization model for electric renewable) software. First, data for wind and solar energies were collected from renewable energy organization of Iran. Second, Geographic Information System (GIS) maps were plotted for solar and wind energies of the country and Lorestan Province where the city of Khorramabad is located. Third for Khorramabad city, the amount of electricity generated by wind, solar, and fuel cell sources were investigated in different months of a year, the contribution of each unit in costs, the amount of costs associated to different power plants, and the amount of pollutant emissions from fuel cell using HOMER. The results indicate that the use of fuel-cell system is not recommended for Khorramabad or similar cities in developing countries due to low performance and high initial costs. On the other hand, using a combined system of wind energy, solar energy, and diesel generator will be economical and is recommended.
- 1 March 2015
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 7 (2) , 023123
Techno-economical assessment of renewable energies integrated with fuel cell for off grid electrification: A case study for developing countries
One of the development parameters of each country is the accessibility of its different regions to energy resources, especially electrical energy. Therefore, construction of new power plants is inevitable. Nevertheless, limited fossil fuel energy resources and environmental pollutant emissions further proves the necessity toward renewable energy use. To overcome intermittent nature of renewable energies such as solar and wind, development of hybrid energy systems has been proposed. In this study, the feasibility of wind and solar renewable energies was investigated for Khorramabad city as an example of a city in a developing country using HOMER (hybrid optimization model for electric renewable) software. First, data for wind and solar energies were collected from renewable energy organization of Iran. Second, Geographic Information System (GIS) maps were plotted for solar and wind energies of the country and Lorestan Province where the city of Khorramabad is located. Third for Khorramabad city, the amount of electricity generated by wind, solar, and fuel cell sources were investigated in different months of a year, the contribution of each unit in costs, the amount of costs associated to different power plants, and the amount of pollutant emissions from fuel cell using HOMER. The results indicate that the use of fuel-cell system is not recommended for Khorramabad or similar cities in developing countries due to low performance and high initial costs. On the other hand, using a combined system of wind energy, solar energy, and diesel generator will be economical and is recommended.