PLPeng Li

Peng Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peng Li has a total of 364 co-authors. Here are the top co-authors by number of shared publications:

  • Jinhua Ye

    Hebei University

    58 shared publications
  • Tao Wang

    Centre for Hydrogenergy College of Materials Science and Technology Nanjing University of Aeronautics and Astronautics Nanjing P. R. China

    26 shared publications
  • Tetsuya Kako

    International Center for Materials Nanoarchitectonics (WPI-MANA), 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan

    18 shared publications
  • Shuxin Ouyang

    TU-NIMS Joint Research Center, School of Materials Science and Engineering, Tianjin University, Nankai District, P. R. China

    17 shared publications
  • Xianguang Meng

    Hebei Provincial Laboratory of Inorganic Nonmetallic Materials, College of Materials Science and Engineering North China University of Science and Technology Tangshan China

    17 shared publications
  • Guigao Liu

    School of Chemistry and Chemical Engineering Nanjing University of Science and Technology Nanjing P. R. China

    16 shared publications

Latest Publications

  • Corrosion detection method of reinforcement in the concrete pole tower based on microwave imaging

    by Lulu Cao, Peng Li, Zijin Li, Baoliang Cao, Jianhong Jiang, Shenhua Wang, Boming Zhang


  • Open Access

    Analysis of Defect Detection for 10 kV Composite Insulator Based on the Microwave Method

    by Peng Li, Longsheng Song, Yuna Fan, Boming Zhang, Zijin Li, Ziheng Pu, Tian Wu

    During the long-term operation of composite insulators in transmission lines, they are easily affected by harsh environments, resulting in hidden defects such as surface contamination, shed damage, and adhesive failure. A defect detection method based on microwave for composite insulators was proposed, and a corresponding numerical simulation model was established. A large-aperture horn antenna model with a wide frequency band and high gain was built, the accuracy of which was verified. In the simulation, shed crack defects were selected as representative probes to model typical defects in the sheds, sheath, and core rod of composite insulators. This study investigated defects with varying severity levels and spatial distributions while also exploring optimal placement configurations for detection antennas. An experimental platform was built for testing, and it was found that the experimental results showed a similar changing trend to the simulation results, which further verified the accuracy of the simulation model and the feasibility of simulating defects.

  • Fault Diagnosis of Motor Bearing under Variable Operating Conditions Based on CDAN-SM

    by Peng Li, Yuxin Wang, Xiaochuan Jing, Haichao Du, Qingwei Meng

    The vibration signal data distribution varies greatly when the motor bearing fails under different working conditions and the signal acquisition is also susceptible to noise interference. These two factors often lead to low accuracy of the cross-domain fault diagnosis task. In order to handle these problems, a novel motor bearing fault diagnosis method based on conditional domain adversarial network with smoothing optimization and minimum class confusion is proposed in this paper. First, the conditional adversarial domain adaptation regulates the domain discriminator and reduces the feature distribution differences between the source and target domains. Second, smoothing optimization is introduced into the network to make the classifier task loss converge to the smoothed minimum value, which stabilizes the adversarial training. Finally, the minimum class confusion is utilized to further improve the classifier’s ability to discriminate different classes of samples in the target domain. Based on the minimum class confusion loss and the smoothed classification loss, the network parameters can be updated via backpropagation progress to effectively reduce the target risk of the classifier. Extensive experiments are conducted on the public Case Western Reserve University (CWRU) dataset, and experimental results show that the proposed method outperforms the compared methods in solving the problem of electric motor bearing fault diagnosis under variable operating conditions.


  • Open Access

    Impact Characteristic Analysis of Tower Foundation Under Concealed Conductive Paths with Grounding Grid Based on a Scaled Model

    by Ziheng Pu, Ruize Qin, Peng Li, Tian Wu

    Concealed conductive connections between a transmission tower’s grounding grid and its foundation can cause a portion of the lightning strike current to enter the foundation and concentrate at the concealed conduction locations, thereby increasing the risk of foundation deterioration. To investigate the impact characteristics of such currents on the foundation under this operating condition, this study first establishes an electro-thermal-mechanical coupled finite-element model of the tower foundation that incorporates a subsurface concealed conductive loop, and compares the foundation’s temperature rise and mechanical characteristics under lightning currents and under power-frequency follow currents. The results indicate that power-frequency follow current poses a substantially greater hazard to the foundation than lightning current. Based on similarity theory, scaling laws for the foundation subjected to the impacts of power-frequency follow current are then derived. Considering that the intrinsic electro-thermal properties of the foundation cannot be altered in the scaled model, a parameter correction method is proposed according to quasi-similarity criteria. The corrected scaled-model results are compared with those of the prototype in simulation, and principal indicators exhibit deviations within 3%. A physical scaled model was subsequently designed and fabricated for impact testing, and ultrasonic inspection was used to assess potential damage in the concealed conduction region. The results show that under the action of power-frequency follow currents, the maximum temperature at the concealed conductive region reaches 124 °C, with deviations of 2.83% from the prototype simulation and 3.58% from the scaled-model simulation. The tower foundation was subjected to 20 power-frequency follow current impacts. After each impact and subsequent cooling, ultrasonic measurements of wave propagation velocity at the concealed conduction center decreased from 3.797 km/s to 3.571 km/s. The observed reduction in wave speed indicates a loss of local concrete structural integrity and suggests the risk of performance degradation and initiation of microcracks. These findings provide a reference basis for assessing the safety of tower foundations under concealed conduction conditions.


  • Prediction of DC breakdown voltage of a vegetation flame insulation gap

    by Ziheng Pu, Chao Liu, Hui Li, Peng Li, Tian Wu, Chunhua Fang, Yaoqiang Wang

  • Open Access

    The Progress and Prospect of Gap Breakdown Characteristics and Discharge Mechanisms of Overhead Transmission Lines Under Vegetation Fire Conditions

    by Haohua Hu, Peng Li, Daochun Huang

    Wildfires frequently occur, posing a significant threat to the operational stability of transmission lines across mountainous forest areas. Therefore, this paper reviews numerous studies conducted by domestic and international scholars on the gap breakdown tests and discharge mechanisms of transmission lines under simulated wildfire conditions. It analyses and summarizes the physical parameter measurement methods commonly used in current experiments. Combining the results of existing experiments, this study analyzes the discharge mechanisms, including the research progress made in numerical simulations. The conclusion is that existing tests are limited in their measurement methods of the physical quantities related to breakdown characteristics, and it is not easy to strictly control experimental variables when considering complex factors. Numerical simulations mainly focus on multi-physical field simulations, which consider the characteristics of vegetation fires in short gaps. The synergistic mechanism of environmental factors on gap breakdown characteristics remains unclear. This paper points out the breakdown characteristics and discharge mechanisms derived from existing experiments and numerical simulations under various influencing factors, highlighting their applicability and limitations, which differ from complex actual transmission lines in the environment. Then, we look forward to the future development of simulation test platforms that could better reflect the actual transmission line corridor environment, incorporating multi-parameter measurement and in-depth numerical simulation works that consider climate and terrain factors.


  • Open Access

    Self-Assembly Strategy for Synthesis of WO3@TCN Heterojunction: Efficient for Photocatalytic Degradation and Hydrogen Production via Water Splitting

    by Li Zhou, Wenjie Zhang, Zezhao Huang, Feng Hu, Peng Li, Xiaoquan Yao

    Herein, a WO3@TCN photocatalyst was successfully synthesized using a self-assembly method, which demonstrated effectiveness in degrading organic dyestuffs and photocatalytic evolution of H2. The synergistic effect between WO3 and TCN, along with the porous structure of TCN, facilitated the formation of a heterojunction that promoted the absorption of visible light, accelerated the interfacial charge transfer, and inhibited the recombination of photogenerated electron–hole pairs. This led to excellent photocatalytic performance of 3%WO3@TCN in degrading TC and catalyzing H2 evolution from water splitting under visible-light irradiation. After modulation, the optimal 3%WO3@TCN exhibited a maximal degradation rate constant that was twofold higher than that of TCN alone and showed continuous H2 generation in the photocatalytic hydrogen evolution. Mechanistic studies revealed that •O2− constituted the major active species for the photocatalytic degradation of tetracycline. Experimental and DFT results verified the electronic transmission direction of WO3@TCN heterojunction. Overall, this study facilitates the structural design of green TCN-based heterojunction photocatalysts and expands the application of TCN in the diverse photocatalytic processes. Additionally, this study offers valuable insights into strategically employing acid regulation modulation to enhance the performance of carbon nitride-based photocatalysts by altering the topography of WO3@TCN composite material dramatically.