Cynthia Owsley

Cynthia Owsley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cynthia Owsley has a total of 255 co-authors. Here are the top co-authors by number of shared publications:

  • Gerald McGwin

    Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States

    50 shared publications
  • Gerald McGwin

    Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, USA

    20 shared publications
  • Christine A. Curcio

    Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States

    14 shared publications
  • Mark E. Clark

    Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA

    14 shared publications
  • Carrie Huisingh

    AbbVie Inc., North Chicago, USA

    10 shared publications
  • Thomas A. Swain

    Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL, United States

    9 shared publications

Latest Publications

  • Open Access

    Reliability-Weighted Multimodal Deep Learning for Glaucoma Detection Across Heterogeneous Clinical Sites

    by Akram Belghith, Donald C. Hood, Emmanouil Tsamis, Ruben Gonzalez, Christopher Bowd, Jalil Jalil, Massimo A. Fazio, Christopher A. Girkin, Cynthia Owsley, Robert N. Weinreb, et al.

  • Open Access

    Patient preferences for portable versus table-mounted visual field devices in rural Alabama: A mixed methods study within a telemedicine setting

    by Ellen K. Antwi-Adjei, Sourav Datta, Christopher A. Girkin, Cynthia Owsley, Lindsay A. Rhodes, Matthew Fifolt, Lyne Racette

    Purpose: To evaluate patient satisfaction and preferences for portable versus table-mounted visual field (VF) devices in a rural telemedicine setting and identify influencing factors. Methods: We conducted a sequential explanatory mixed methods study at three Federally Qualified Health Centers (FQHCs) within the Alabama Screening and Intervention for Glaucoma and eye Health through Telemedicine (AL-SIGHT) study. Participants completed VF testing with table-mounted Humphrey Field Analyzer (HFA), tablet-based Melbourne Rapid Fields (MRF), and virtual reality (VR)-based VisuALL perimeters. Participants rated satisfaction, comfort, ease of use, and future testing preference. Chi-square tests assessed differences in device preferences. Twelve participants completed semi-structured interviews to explore reasons underlying preferences. Qualitative data were analyzed in NVivo 14 using reflexive thematic analysis. Results: Among 271 respondents (mean age 60.4 years; 62.4% women), 50.6% preferred VR-based, 35.1% tablet-based, and 14.4% table-mounted for future testing (χ 2 (2) = 53.52, p < 0.001, Cramér’s V = 0.31). Satisfaction was highest for VR-based (56.9% very satisfied), followed by tablet-based (49.4%), and HFA (38.0%). VR-based perimeter was most frequently selected as the most comfortable (55.7%; χ 2 (2) = 63.33, p < 0.001, V = 0.34) and easiest to use (54.6%; χ 2 (2) = 71.96, p < 0.001, V = 0.36). Preferences did not vary significantly across demographic variables (all p > 0.05). Qualitative themes identified four key drivers: comfort and physical experience, visual experience, ease of use and interaction, and psychological and motivational factors. Portability and community suitability were valued. Conclusion: Rural underserved patients strongly preferred portable visual field devices, particularly VR-based, over table-mounted HFA. Comfort, ergonomic flexibility, immersive visual experience, and simplicity of interaction were central determinants of preference. Portable perimetry may enhance patient-centered glaucoma monitoring within telemedicine programs and access in resource-limited settings.

  • Open Access

    Impaired Rod-Mediated Vision is the Functional Hallmark of Ageing and Early and Intermediate Age-Related Macular Degeneration

    by Cynthia Owsley, Christine A. Curcio

    Laboratory and patient-oriented research on photoreceptors and vision in ageing and early and intermediate age-related macular degeneration (AMD) were conducted in parallel starting in the 1990s by Christine Curcio and Cynthia Owsley, respectively. They joined forces in two longitudinal observation studies, the Alabama Study on Age-related Macular Degeneration (ALSTAR) in 2009 and in ALSTAR2 in 2019, together involving >1100 participants. These studies established rod-mediated dark adaptation (RMDA) measured close to the fovea as the first functional biomarker for incident early AMD and the progression of AMD. These studies used standardised grading of colour fundus photography and prioritised large samples for statistical power. RMDA is a global measure of dysregulated transport between the circulation and photoreceptors, involving at least seven different steps in a retinoid re-supply route especially needed by rods, and a surrogate for the delivery of other essentials across this route. The choice of functional and imaging outcome measures was informed by a model of AMD pathophysiology based on drusen biology, as discovered in the laboratory using high-quality human donor eyes. Specifically, high-risk drusen in the central retina were thought to result from large lipoproteins constitutively made by the retinal pigment epithelium and impaired in transit to circulation by ageing changes in Bruch’s membrane and choriocapillaris. Imaging studies in ALSTAR/2 thus included optical coherence tomography (OCT) angiography assessments of choriocapillaris flow signal and OCT assessments of outer bands involved in intercellular transfer (interdigitation zone). Of seven vision tests utilised in ALSTAR2, only RMDA achieved a Minimum Clinically Important Difference at 3 years follow-up. This research highlights the importance of developing functionally valid structural endpoints for use in early and intermediate AMD intervention trials. Research to date supports the idea that functional changes emerge earlier than structural changes in early and intermediate AMD. Clinicaltrials.gov # NCT04112667 (registration date October 7, 2019)


  • Open Access

    Patient preferences for portable versus table-mounted visual field devices in rural Alabama: a mixed methods study within a telemedicine setting

    by Ellen Konadu Antwi-Adjei, Sourav Datta, Christopher A. Girkin, Cynthia Owsley, Lindsay A. Rhodes, Matthew Fifolt, Lyne Racette

    Purpose To evaluate patient satisfaction and preferences for portable versus table-mounted visual field (VF) devices in a rural telemedicine setting and identify influencing factors. Methods We conducted a sequential explanatory mixed methods study at three Federally Qualified Health Centers (FQHCs) within the Alabama Screening and Intervention for Glaucoma and eye Health through Telemedicine (AL-SIGHT) study. Participants completed VF testing with table-mounted Humphrey Field Analyzer (HFA), tablet-based Melbourne Rapid Fields (MRF), and virtual reality (VR)-based VisuALL perimeters. Participants rated satisfaction, comfort, ease of use, and future testing preference. Chi-square tests assessed differences in device preferences. Twelve participants completed semi-structured interviews to explore reasons underlying preferences. Qualitative data were analyzed in NVivo 14 using reflexive thematic analysis. Results Among 271 respondents (mean age 60.4 years; 62.4% women), 50.6% preferred VR-based, 35.1% tablet-based, and 14.4% table-mounted for future testing (χ2 (2) = 53.52, p<0.001, Cramér’s V = 0.31). Satisfaction was highest for VR-based (56.9% very satisfied), followed by tablet-based (49.4%), and HFA (38.0%). VR-based perimeter was most frequently selected as the most comfortable (55.7%; χ2 (2) = 63.33, p<0.001, V = 0.34) and easiest to use (54.6%; χ2 (2) = 71.96, p0.05). Qualitative themes identified four key drivers: comfort and physical experience, visual experience, ease of use and interaction, and psychological and motivational factors. Portability and community suitability were valued. Conclusion Rural underserved patients strongly preferred portable visual field devices, particularly VR-based, over table-mounted HFA. Comfort, ergonomic flexibility, immersive visual experience, and simplicity of interaction were central determinants of preference. Portable perimetry may enhance patient-centered glaucoma monitoring within telemedicine programs and access in resource-limited settings.

  • Open Access

    A Manual of Procedures for the Generation of the AI-Ready and Exploratory Atlas for Diabetes Insights (AI-READI) Database

    by Dawn S. Matthies, Jeffrey C. Edberg, Sally L. Baxter, Aaron Y. Lee, Cecilia S. Lee, Gerald McGwin, Julia P. Owen, Linda M. Zangwill, Cynthia Owsley

    The ability to understand and affect the course of complex, multi-system diseases like diabetes has been limited by a lack of well-designed, high-quality and large multimodal datasets. The NIH Bridge2AI AI-READI project ( aireadi.org ) aims to address this shortfall by generating an AI-ready dataset to support AI discoveries in type 2 diabetes mellitus (T2DM). This manual of procedures provides a detailed description of the AI-READI protocol.

  • Top Cited Papers
    Open Access

    The Science of Rod-Mediated Dark Adaptation, an Outcome Measure for Age-Related Macular Degeneration: The 2025 Proctor Medal Lecture

    by Christine A. Curcio, Cynthia Owsley

    Age-related macular degeneration (AMD) degrades central vision in older adults worldwide. To enable precision prevention and early intervention, the longitudinal Alabama Study of Age-related Macular Degeneration 2 (ALSTAR2) seeks functional and imaging outcomes at the aging-AMD interface. ALSTAR2 relies on accurate two-dimensional maps of photoreceptor and retinal pigment epithelium (RPE) distributions and a histology-informed, deposit-driven progression sequence involving dysregulated bi-directional transport between photoreceptors and circulation. This transport is globally assessed by rod-mediated dark adaptation (RMDA), a dynamic measure of rod sensitivity recovery after exposure to a bright light. RMDA measured at the rim of the high-risk macula lutea is affected earlier and is more predictive of AMD onset and progression than steady-state functional measures of rods, cones, and neural circuitry, in both tested and fellow eyes. Delayed RMDA incorporates the Oil Spill hypothesis of drusen formation, which posits that lipoprotein particles constitutively released by RPE are trapped by aged Bruch's membrane and choriocapillaris. Subretinal drusenoid deposit, associated with poor RMDA and risk for advanced AMD, may represent a late-appearing barrier to transport at the level of the RPE. Although RMDA slowing is already underway before routinely visible AMD pathology, some structural and metabolic imaging technologies may assist early detection.


  • Standardizing Measurement of Complete Retinal Pigment Epithelial and Outer Retinal Atrophy: Classification of Atrophy Meeting Report 8

    by David Sarraf, Federico Corvi, Philip J. Rosenfeld, Thomas Ach, Barbara Blodi, Ferdinando Bottoni, Mariano Cozzi, Usha Chakravarthy, Emily Y. Chew, Karl Csaky, et al.


  • Open Access

    Preserved Contrast Sensitivity in Early and Intermediate Age-Related Macular Degeneration and Marked Loss in Late Stage: ALSTAR2

    by Cynthia Owsley, Liyan Gao, Lindsay Gooden, Tracy N. Thomas, Jiaxin Pu, Jason N. Crosson, Christine A. Curcio, Gerald McGwin, MiYoung Kwon

    To cross-sectionally compare parameters from the quick contrast sensitivity function (qCSF)-area under the log CSF (AULCSF) and sensitivity at each spatial frequency-in older eyes with normal macular health and early, intermediate, and late AMD. Our purpose was to determine whether qCSF could be a promising functional outcome measure in interventions designed to slow AMD progression from aging to late AMD. qCSF contrast sensitivity was measured at 1.0 to 18 cycles per degree (cyc/deg). Models evaluated the impact of diagnostic group on the AULCSF and individual spatial frequencies, adjusting for age and lens status. The AREDS nine-step classification system defined AMD presence and severity. Eight hundred twenty-three eyes were studied: 383 normal macular health, 203 early AMD, 208 intermediate AMD, and 29 late AMD (23 geographic atrophy, six neovascular AMD). AULCSF decreased with increasing AMD severity; this was mostly attributable to the late AMD eyes having lower AULCSF than other groups. Late AMD eyes had significantly worse sensitivity at 1 and 1.5 cyc/deg compared to all other groups, with other groups having similar sensitivity. At frequencies near or just beyond the CSF peak (3-12 cyc/deg), late AMD eyes again had the worst sensitivity, with intermediate AMD eyes having slightly worse sensitivity than early AMD eyes. There were no group differences at 18 cyc/deg. The qCSF will be most useful in trials studying the transition from intermediate AMD to late-stage AMD, rather than in studying the transition from aging to early and intermediate AMD.


  • Open Access

    Natural History of Visual Function Changes Over Three Years in Normal Aging and in Early and Intermediate Age-Related Macular Degeneration: ALSTAR2

    by Cynthia Owsley, Gerald McGwin, Liyan Gao, Mark E. Clark, Lindsay Gooden, Tracy N. Thomas, Lukas Goerdt, Christine A. Curcio

    The purpose of this study was to evaluate change in visual functions over 3 years in normal macular health, and early and intermediate age-related macular degeneration (AMD) including tests of rod-, cone-, and mixed rod-cone-mediated visions; and to evaluate whether visual function change over 3 years meets the minimal clinically important difference (MCID), defined as meaningful to patients in everyday life. Eight visual functions were evaluated at baseline and 3-year follow-up (acuity, low luminance acuity, photopic and mesopic contrast sensitivity, mesopic and scotopic light sensitivity, and rod-mediated dark adaptation [RMDA] at 5 degrees and 12 degrees). The Age-Related Eye Disease Study (AREDS) 9-step classification system defined AMD severity. In normal aging and intermediate AMD, 6 of 8 visual functions had statistically significant worsening over 3 years; mesopic contrast sensitivity and mesopic light sensitivity, respectively, showed no change. In early AMD, five of eight visual functions showed worsening over time, with photopic and mesopic contrast sensitivity and scotopic sensitivity unchanged. The largest percentage of eyes in each group meeting MCID was RMDA at 5 degrees or 12 degrees (38%-55%). The lowest percentage of eyes meeting MCID was visual acuity and photopic contrast sensitivity (0%-10%). Whereas most visual functions evaluated have statistically significant worsening over 3 years in normal aging to intermediate eyes, the percentage of eyes reaching MCID was low for most visual functions except RMDA, which met MCID for almost half the eyes. The natural history of change in visual function over time in normal aging to intermediate AMD should be characterized in terms of MCID, not only statistical significance.


  • Hypertransmission and Vision in Aging and Age-Related Macular Degeneration: Longitudinal Data From ALSTAR2

    by Will Johnston, Sarah S. Kim, Deepayan Kar, Liyan Gao, Mark E. Clark, Gerald McGwin Jr., Kenneth R. Sloan, Cynthia Owsley, Christine A. Curcio, Lukas Goerdt