Chung-Chih Hung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chung-Chih Hung has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Tien-Yu Lo
Mediatek Inc
5 shared publications - Chia-Min Chen
National Chiao Tung University
4 shared publications - Chung-Yu Wu
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu City, Taiwan
4 shared publications - Ming-Dou Ker
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
4 shared publications - Fang-Ting Chou
National Chiao Tung University
3 shared publications - Chi-Wei Huang
Biomedical Electronics Translational Research Center, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
2 shared publications
Latest Publications
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 718-719
Guest Editorial: Special Issue on Selected Articles From IEEE BioCAS 2023
The 12 articles in this special issue were presented at the 2023 IEEE Biomedical Circuits and Systems Conference (BioCAS) in Toronto, Canada, from October 19–21, 2023. BioCAS 2023 was jointly sponsored by the IEEE Circuits and Systems (CAS) Society, IEEE Solid-State Circuits (SSC) Society, and the IEEE Engineering in Medicine and Biology (EMB) Society.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 718-719
Guest Editorial: Special Issue on Selected Articles From IEEE BioCAS 2023
The 12 articles in this special issue were presented at the 2023 IEEE Biomedical Circuits and Systems Conference (BioCAS) in Toronto, Canada, from October 19–21, 2023. BioCAS 2023 was jointly sponsored by the IEEE Circuits and Systems (CAS) Society, IEEE Solid-State Circuits (SSC) Society, and the IEEE Engineering in Medicine and Biology (EMB) Society.
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 539-551
Design of CMOS Analog Front-End Local-Field Potential Chopper Amplifier With Stimulation Artifact Tolerance for Real-Time Closed-Loop Deep Brain Stimulation SoC Applications
A CMOS analog front-end (AFE) local-field potential (LFP) chopper amplifier with stimulation artifact tolerance, improved right-leg driven (RLD) circuit, and improved auxiliary path is proposed. In the proposed CMOS AFE LFP chopper amplifier, common-mode artifact voltage (CMAV) and differential-mode artifact voltage (DMAV) removal using the analog template removal method are proposed to achieve good signal linearity during stimulation. An improved auxiliary path is employed to boost the input impedance and allow the negative stimulation artifact voltage passing through. The common-mode noise is suppressed by the improved RLD circuit. The chip is implemented in 0.18-μm CMOS technology and the total chip area is 5.46-mm2. With the improved auxiliary path, the measured input impedance is larger than 133 MΩ in the signal bandwidth and reaches 8.2 GΩ at DC. With the improved RLD circuit, the measured CMRR is 131 – 144 dB in the signal bandwidth. Under 60-μs pulse width and 130-Hz constant current stimulation (CCS) with ±1-V CMAV and ±50-mV DMAV, the measured THD at the SC Amp output of fabricated AFE LFP chopper amplifier is 1.28%. The measurement results of In vitro agar tests have shown that with ±1.6-mA CCS pulses injecting to agar, the measured THD is 1.69%. Experimental results of both electrical and agar tests have verified that the proposed AFE LFP chopper amplifier has good stimulation artifact tolerance. The proposed CMOS AFE LFP chopper amplifier with analog template removal method is suitable for real-time closed-loop deep drain stimulation (DBS) SoC applications
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 539-551
Design of CMOS Analog Front-End Local-Field Potential Chopper Amplifier With Stimulation Artifact Tolerance for Real-Time Closed-Loop Deep Brain Stimulation SoC Applications
A CMOS analog front-end (AFE) local-field potential (LFP) chopper amplifier with stimulation artifact tolerance, improved right-leg driven (RLD) circuit, and improved auxiliary path is proposed. In the proposed CMOS AFE LFP chopper amplifier, common-mode artifact voltage (CMAV) and differential-mode artifact voltage (DMAV) removal using the analog template removal method are proposed to achieve good signal linearity during stimulation. An improved auxiliary path is employed to boost the input impedance and allow the negative stimulation artifact voltage passing through. The common-mode noise is suppressed by the improved RLD circuit. The chip is implemented in 0.18-μm CMOS technology and the total chip area is 5.46-mm2. With the improved auxiliary path, the measured input impedance is larger than 133 MΩ in the signal bandwidth and reaches 8.2 GΩ at DC. With the improved RLD circuit, the measured CMRR is 131 – 144 dB in the signal bandwidth. Under 60-μs pulse width and 130-Hz constant current stimulation (CCS) with ±1-V CMAV and ±50-mV DMAV, the measured THD at the SC Amp output of fabricated AFE LFP chopper amplifier is 1.28%. The measurement results of In vitro agar tests have shown that with ±1.6-mA CCS pulses injecting to agar, the measured THD is 1.69%. Experimental results of both electrical and agar tests have verified that the proposed AFE LFP chopper amplifier has good stimulation artifact tolerance. The proposed CMOS AFE LFP chopper amplifier with analog template removal method is suitable for real-time closed-loop deep drain stimulation (DBS) SoC applications
- 17 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 31 (12) , 1939-1949
A Low-Noise Area-Efficient Column-Parallel ADC With an Input Triplet for a 120-dB High Dynamic Range CMOS Image Sensor
This article presents and demonstrates the design of a high dynamic range (HDR) CMOS image sensor (CIS). Detailed operation of various comparator circuits is analyzed. A low-noise, area-efficient, wide-input range comparator is proposed for HDR applications. Based on the analysis, a six-transistor (6T) comparator is proposed with a p-type metal oxide semiconductor (PMOS) input triplet, which effectively increases the input range of a conventional PMOS-input type comparator and compensates the charge injection and kT/C noise introduced from pixels switching between high-conversion-gain (HCG) and low-conversion-gain (LCG) modes. The proposed scheme achieves an extra high dynamic range (DR). A full HD (1920 $\times$ 1080) HDR image sensor with 2.9 $\mu $ m pixel pitches is fabricated in a 55 nm one-ploy five-metal (1P5M) CIS process. The incorporated analog-to-digital conversion (ADC) demonstrates a 12-bit resolution, a noise of 96 $\mu_{\mathrm{VRMS}}$ , a power consumption of 25 $\mu $ W, an area of 2.9 $\times$ 400 $\mu$ m, and its integral non-linearity (INL) and differential non-linearity (DNL) are $-$ 0.43/ $+$ 7.22 and $-$ 0.30/ $+$ 0.29 LSB, respectively. The sensor achieves a 120-dB DR at 30 frames/sec and a temporal noise of 0.91e-.
- 17 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 31 (12) , 1939-1949
A Low-Noise Area-Efficient Column-Parallel ADC With an Input Triplet for a 120-dB High Dynamic Range CMOS Image Sensor
This article presents and demonstrates the design of a high dynamic range (HDR) CMOS image sensor (CIS). Detailed operation of various comparator circuits is analyzed. A low-noise, area-efficient, wide-input range comparator is proposed for HDR applications. Based on the analysis, a six-transistor (6T) comparator is proposed with a p-type metal oxide semiconductor (PMOS) input triplet, which effectively increases the input range of a conventional PMOS-input type comparator and compensates the charge injection and kT/C noise introduced from pixels switching between high-conversion-gain (HCG) and low-conversion-gain (LCG) modes. The proposed scheme achieves an extra high dynamic range (DR). A full HD (1920 $\times$ 1080) HDR image sensor with 2.9 $\mu $ m pixel pitches is fabricated in a 55 nm one-ploy five-metal (1P5M) CIS process. The incorporated analog-to-digital conversion (ADC) demonstrates a 12-bit resolution, a noise of 96 $\mu_{\mathrm{VRMS}}$ , a power consumption of 25 $\mu $ W, an area of 2.9 $\times$ 400 $\mu$ m, and its integral non-linearity (INL) and differential non-linearity (DNL) are $-$ 0.43/ $+$ 7.22 and $-$ 0.30/ $+$ 0.29 LSB, respectively. The sensor achieves a 120-dB DR at 30 frames/sec and a temporal noise of 0.91e-.
- Open Access
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 650-652
Guest Editorial Special Issue on Selected Papers from IEEE BioCAS 2022
The 16 papers in this special issue were presented at the 2022 IEEE Biomedical Circuits and Systems Conference (BioCAS) in Taipei, Taiwan, from October 13–15, 2022. BioCAS 2022 was jointly sponsored by the IEEE Circuits and Systems (CAS) Society, IEEE Solid-State Circuits (SSC) Society, and the IEEE Engineering in Medicine and Biology (EMB) Society.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 650-652
Open AccessGuest Editorial Special Issue on Selected Papers from IEEE BioCAS 2022
The 16 papers in this special issue were presented at the 2022 IEEE Biomedical Circuits and Systems Conference (BioCAS) in Taipei, Taiwan, from October 13–15, 2022. BioCAS 2022 was jointly sponsored by the IEEE Circuits and Systems (CAS) Society, IEEE Solid-State Circuits (SSC) Society, and the IEEE Engineering in Medicine and Biology (EMB) Society.
- 17 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70 (6) , 2257-2270
A CMOS Synchronized Sample-and-Hold Artifact Blanking Analog Front-End Local Field Potential Acquisition Unit With ±3.6-V Stimulation Artifact Tolerance and Monopolar Electrode-Tissue Impedance Measurement Circuit for Closed-Loop Deep Brain Stimulation SoCs
In this paper, an analog front-end (AFE) local-field potential (LFP) acquisition unit with real-time stimulation artifact removal is proposed and verified for closed-loop deep brain stimulation (DBS) applications. The proposed acquisition unit is called the synchronized sample-and-hold stimulation artifact blanking (SSAB) AFE LFP acquisition unit. Both right-leg-driven (RLD) circuit and monopolar electrode-tissue impedance (ETI) measurement circuit associated with the AFE amplifier are also proposed. During closed-loop stimulations, the artifact removal is realized through the SSAB-IPC by blanking the AR-CCIA with a clock synchronized to the stimulation-enable signal and holding the amplifier at its state before stimulation through a sample-and-hold operation. After stimulation, the acquisition unit can quickly recover from the holding state back to the LFP recording state to reduce the discontinuity in LFP recording. The proposed acquisition unit was fabricated in 0.18-um CMOS technology. With the RLD circuit, the measured CMRR is 124 – 145 dB in the signal bandwidth. The fabricated monopolar ETI measurement circuit has a measurement error less than 8.3% with an extra power consumption of 2.65 $\mu $ W. The experimental results have shown that the proposed SSAB AFE LFP acquisition unit is feasible for the integration of SoCs in real-time closed-loop DBS systems for various applications.
- 17 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70 (6) , 2257-2270
A CMOS Synchronized Sample-and-Hold Artifact Blanking Analog Front-End Local Field Potential Acquisition Unit With ±3.6-V Stimulation Artifact Tolerance and Monopolar Electrode-Tissue Impedance Measurement Circuit for Closed-Loop Deep Brain Stimulation SoCs
In this paper, an analog front-end (AFE) local-field potential (LFP) acquisition unit with real-time stimulation artifact removal is proposed and verified for closed-loop deep brain stimulation (DBS) applications. The proposed acquisition unit is called the synchronized sample-and-hold stimulation artifact blanking (SSAB) AFE LFP acquisition unit. Both right-leg-driven (RLD) circuit and monopolar electrode-tissue impedance (ETI) measurement circuit associated with the AFE amplifier are also proposed. During closed-loop stimulations, the artifact removal is realized through the SSAB-IPC by blanking the AR-CCIA with a clock synchronized to the stimulation-enable signal and holding the amplifier at its state before stimulation through a sample-and-hold operation. After stimulation, the acquisition unit can quickly recover from the holding state back to the LFP recording state to reduce the discontinuity in LFP recording. The proposed acquisition unit was fabricated in 0.18-um CMOS technology. With the RLD circuit, the measured CMRR is 124 – 145 dB in the signal bandwidth. The fabricated monopolar ETI measurement circuit has a measurement error less than 8.3% with an extra power consumption of 2.65 $\mu $ W. The experimental results have shown that the proposed SSAB AFE LFP acquisition unit is feasible for the integration of SoCs in real-time closed-loop DBS systems for various applications.
- 21 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (10) , 3062-3076
Design of a Bone-Guided Cochlear Implant Microsystem With Monopolar Biphasic Multiple Stimulations and Evoked Compound Action Potential Acquisition and Its In Vivo Verification
A CMOS bone-guided cochlear implant (BGCI) microsystem is proposed and verified. In the implanted System on Chip (SoC) of the proposed BGCI, the evoked compound action potential (ECAP) acquisition and electrode–tissue impedance measurement (EAEIM) circuit is integrated to measure both ECAP and electrode–tissue impedance for clinical diagnoses. Both positive-/negative-voltage charge pumps and monopolar biphasic constant-current stimulation (CCS) stimulator are designed on-chip to realize monopolar biphasic CCS or double-electrode multiple stimulations with a maximum stimulation current of 1.2 mA and a step of 10 $\mu \text{A}$ . With the double-electrode multiple stimulations, the electric field can be shifted and localized under the stimulating electrode to stimulate the auditory nerves. The wireless bilateral data telemetry circuits with a full-wave active rectifier and the pulsed load-shift keying (PLSK) modulators/demodulators are designed for power and data transmission. In vivo animal tests on guinea pigs have shown that the Wave III of electrically evoked auditory brainstem responses (EABRs) can be evoked successfully by electrical stimulation. Moreover, the decreasing latency gradient of evoked Wave III has been measured under the double-electrode multiple stimulations where the location of peak electric field can be shifted to the stimulating electrode in the apical site to stimulate the auditory nerves. Thus, the desired frequency resolution and spatial specificity of stimulation can be achieved. Both electrical measurement and in vivo animal tests have verified that the proposed BGCI microsystem is a feasible solution to eliminate the symptoms for patients with high-frequency hearing loss.
- 21 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (10) , 3062-3076
Design of a Bone-Guided Cochlear Implant Microsystem With Monopolar Biphasic Multiple Stimulations and Evoked Compound Action Potential Acquisition and Its In Vivo Verification
A CMOS bone-guided cochlear implant (BGCI) microsystem is proposed and verified. In the implanted System on Chip (SoC) of the proposed BGCI, the evoked compound action potential (ECAP) acquisition and electrode–tissue impedance measurement (EAEIM) circuit is integrated to measure both ECAP and electrode–tissue impedance for clinical diagnoses. Both positive-/negative-voltage charge pumps and monopolar biphasic constant-current stimulation (CCS) stimulator are designed on-chip to realize monopolar biphasic CCS or double-electrode multiple stimulations with a maximum stimulation current of 1.2 mA and a step of 10 $\mu \text{A}$ . With the double-electrode multiple stimulations, the electric field can be shifted and localized under the stimulating electrode to stimulate the auditory nerves. The wireless bilateral data telemetry circuits with a full-wave active rectifier and the pulsed load-shift keying (PLSK) modulators/demodulators are designed for power and data transmission. In vivo animal tests on guinea pigs have shown that the Wave III of electrically evoked auditory brainstem responses (EABRs) can be evoked successfully by electrical stimulation. Moreover, the decreasing latency gradient of evoked Wave III has been measured under the double-electrode multiple stimulations where the location of peak electric field can be shifted to the stimulating electrode in the apical site to stimulate the auditory nerves. Thus, the desired frequency resolution and spatial specificity of stimulation can be achieved. Both electrical measurement and in vivo animal tests have verified that the proposed BGCI microsystem is a feasible solution to eliminate the symptoms for patients with high-frequency hearing loss.
- 30 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. PP (19324545) , 1
A 0.3V 10b 3MS/s SAR ADC with Comparator Calibration and Kickback Noise Reduction for Biomedical Applications
This paper presents a 10-bit successive approximation analog-to-digital converter (ADC) that operates at an ultralow voltage of 0.3 V and can be applied to biomedical implants. The study proposes several techniques to improve the ADC performance. A pipeline comparator was utilized to maintain the advantages of dynamic comparators and reduce the kickback noise. Weight biasing calibration was used to correct the offset voltage without degrading the operating speed of the comparator. The incorporation of a unity-gain buffer improved the bootstrap switch leakage problem during the hold period and reduced the effect of parasitic capacitances on the digital-to-analog converter. The chip was fabricated using 90-nm CMOS technology. The data measured at a supply voltage of 0.3 V and sampling rate of 3 MSps for differential nonlinearity and integral nonlinearity were ±0.83/-0.54 and ±0.84/-0.89, respectively, and the signal-to-noise plus distortion ratio and effective number of bits were 56.42 dB and 9.08 b, respectively. The measured total power consumption was 6.6 μW at a figure of merit of 4.065 fJ/conv.-step.
- 30 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. PP (19324545) , 1
A 0.3V 10b 3MS/s SAR ADC with Comparator Calibration and Kickback Noise Reduction for Biomedical Applications
This paper presents a 10-bit successive approximation analog-to-digital converter (ADC) that operates at an ultralow voltage of 0.3 V and can be applied to biomedical implants. The study proposes several techniques to improve the ADC performance. A pipeline comparator was utilized to maintain the advantages of dynamic comparators and reduce the kickback noise. Weight biasing calibration was used to correct the offset voltage without degrading the operating speed of the comparator. The incorporation of a unity-gain buffer improved the bootstrap switch leakage problem during the hold period and reduced the effect of parasitic capacitances on the digital-to-analog converter. The chip was fabricated using 90-nm CMOS technology. The data measured at a supply voltage of 0.3 V and sampling rate of 3 MSps for differential nonlinearity and integral nonlinearity were ±0.83/-0.54 and ±0.84/-0.89, respectively, and the signal-to-noise plus distortion ratio and effective number of bits were 56.42 dB and 9.08 b, respectively. The measured total power consumption was 6.6 μW at a figure of merit of 4.065 fJ/conv.-step.
- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1759-1770
A 0.35-V 240-μW Fast-Lock and Low-Phase-Noise Frequency Synthesizer for Implantable Biomedical Applications
For implantable frequency synthesizers, realizing ultra-low voltage (ULV) and low power in addition to meeting PLL targets, fast lock and low phase noise, poses a difficult challenge. This paper presents techniques to achieve PLL targets as well as ULV and low power in the same chip through the use of a regular CMOS technology node. A curvature-PFD technique achieves both faster locking and lower jitter compared with conventional techniques. A two-step switching technique substantially reduces the power consumption in current mirrors and reduce noise when switching from a charge pump. Leakage analysis and subthreshold-leakage-reduction technique reduce reference spur and jitter to the voltage-controlled oscillator (VCO). A dither technique randomizes and averages reference spurs. The proposed chip was implemented in 90-nm CMOS technology; the 0.35-V medical-band frequency synthesizer consumes 238 μW power while generating output clock of 401.8 to 431.31-MHz and exhibiting a phase noise of −105.7 dBc/Hz at 1-MHz frequency offset with 20 μS locking time.
- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1759-1770
A 0.35-V 240-μW Fast-Lock and Low-Phase-Noise Frequency Synthesizer for Implantable Biomedical Applications
For implantable frequency synthesizers, realizing ultra-low voltage (ULV) and low power in addition to meeting PLL targets, fast lock and low phase noise, poses a difficult challenge. This paper presents techniques to achieve PLL targets as well as ULV and low power in the same chip through the use of a regular CMOS technology node. A curvature-PFD technique achieves both faster locking and lower jitter compared with conventional techniques. A two-step switching technique substantially reduces the power consumption in current mirrors and reduce noise when switching from a charge pump. Leakage analysis and subthreshold-leakage-reduction technique reduce reference spur and jitter to the voltage-controlled oscillator (VCO). A dither technique randomizes and averages reference spurs. The proposed chip was implemented in 90-nm CMOS technology; the 0.35-V medical-band frequency synthesizer consumes 238 μW power while generating output clock of 401.8 to 431.31-MHz and exhibiting a phase noise of −105.7 dBc/Hz at 1-MHz frequency offset with 20 μS locking time.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 25, 738-741
Current-Voltage-Dual-Mode DC-DC Buck Converter with Adaptive Clock Control
This paper presents a novel high-efficiency and fast-transient current-voltage-dual-mode (CVDM) dc-dc buck converter using adaptive clock controller (ACC). The proposed CVDM control can stably switch the control method between current mode and voltage mode to improve the performance according to different situations. By using the ACC technique, the circuit can dynamically and smoothly adjust the switching frequency during the transient response to improve the undershoot, overshoot voltage, and recovery time. In this work, only an output inductor, capacitor, and feedback resistors are outside the system on chip (SoC). The transient recovery time and undershoot voltage are less than 5μs and 60mV, respectively, for the load current change from 50mA to 500mA. The maximum conversion efficiency is 95% at 100mA load current. Above 90% conversion efficiency can be achieved for load current from 30mA to 600mA. With the proposed techniques, the performance of the dc-dc converter is improved significantly.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 25, 738-741
Current-Voltage-Dual-Mode DC-DC Buck Converter with Adaptive Clock Control
This paper presents a novel high-efficiency and fast-transient current-voltage-dual-mode (CVDM) dc-dc buck converter using adaptive clock controller (ACC). The proposed CVDM control can stably switch the control method between current mode and voltage mode to improve the performance according to different situations. By using the ACC technique, the circuit can dynamically and smoothly adjust the switching frequency during the transient response to improve the undershoot, overshoot voltage, and recovery time. In this work, only an output inductor, capacitor, and feedback resistors are outside the system on chip (SoC). The transient recovery time and undershoot voltage are less than 5μs and 60mV, respectively, for the load current change from 50mA to 500mA. The maximum conversion efficiency is 95% at 100mA load current. Above 90% conversion efficiency can be achieved for load current from 30mA to 600mA. With the proposed techniques, the performance of the dc-dc converter is improved significantly.
- 19 July 2019
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 101 (3) , 573-584
Dual active capacitive feedbacks for output capacitor-less low-dropout regulator
- 19 July 2019
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 101 (3) , 573-584
Dual active capacitive feedbacks for output capacitor-less low-dropout regulator