Ali Sarrami-Foroushani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Sarrami-Foroushani has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Federico Frangi
University of Manchester
9 shared publications - Toni Lassila
Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
7 shared publications - Mohsen Nasr Esfahany
Department of Chemical Engineering, Isfahan University of Technology, Isfahan, Iran
3 shared publications Ali Gooya
Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), Department of Electronic and Electrical Engineering, The University of Sheffield, Pam Liversidge Building, Mappin Street, Sheffield S1 3JD, UK
2 shared publicationsHamidreza Saligheh Rad
Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
2 shared publicationsHossein Ghanaati
Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences, Tehran, Iran
2 shared publications
Latest Publications
- Open Access
- 14 February 2024
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 21 (211) , 20230565
Accelerated simulation methodologies for computational vascular flow modelling
Vascular flow modelling can improve our understanding of vascular pathologies and aid in developing safe and effective medical devices. Vascular flow models typically involve solving the nonlinear Navier–Stokes equations in complex anatomies and using physiological boundary conditions, often presenting a multi-physics and multi-scale computational problem to be solved. This leads to highly complex and expensive models that require excessive computational time. This review explores accelerated simulation methodologies, specifically focusing on computational vascular flow modelling. We review reduced order modelling (ROM) techniques like zero-/one-dimensional and modal decomposition-based ROMs and machine learning (ML) methods including ML-augmented ROMs, ML-based ROMs and physics-informed ML models. We discuss the applicability of each method to vascular flow acceleration and the effectiveness of the method in addressing domain-specific challenges. When available, we provide statistics on accuracy and speed-up factors for various applications related to vascular flow simulation acceleration. Our findings indicate that each type of model has strengths and limitations depending on the context. To accelerate real-world vascular flow problems, we propose future research on developing multi-scale acceleration methods capable of handling the significant geometric variability inherent to such problems.
- 14 February 2024
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 21 (211) , 20230565
Open AccessAccelerated simulation methodologies for computational vascular flow modelling
Vascular flow modelling can improve our understanding of vascular pathologies and aid in developing safe and effective medical devices. Vascular flow models typically involve solving the nonlinear Navier–Stokes equations in complex anatomies and using physiological boundary conditions, often presenting a multi-physics and multi-scale computational problem to be solved. This leads to highly complex and expensive models that require excessive computational time. This review explores accelerated simulation methodologies, specifically focusing on computational vascular flow modelling. We review reduced order modelling (ROM) techniques like zero-/one-dimensional and modal decomposition-based ROMs and machine learning (ML) methods including ML-augmented ROMs, ML-based ROMs and physics-informed ML models. We discuss the applicability of each method to vascular flow acceleration and the effectiveness of the method in addressing domain-specific challenges. When available, we provide statistics on accuracy and speed-up factors for various applications related to vascular flow simulation acceleration. Our findings indicate that each type of model has strengths and limitations depending on the context. To accelerate real-world vascular flow problems, we propose future research on developing multi-scale acceleration methods capable of handling the significant geometric variability inherent to such problems.
- Open Access
- 7 July 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (3) , 036102
Hemodynamics of thrombus formation in intracranial aneurysms: An in silico observational study
How prevalent is spontaneous thrombosis in a population containing all sizes of intracranial aneurysms? How can we calibrate computational models of thrombosis based on published data? How does spontaneous thrombosis differ in normo- and hypertensive subjects? We address the first question through a thorough analysis of published datasets that provide spontaneous thrombosis rates across different aneurysm characteristics. This analysis provides data for a subgroup of the general population of aneurysms, namely, those of large and giant size (>10 mm). Based on these observed spontaneous thrombosis rates, our computational modeling platform enables the first in silico observational study of spontaneous thrombosis prevalence across a broader set of aneurysm phenotypes. We generate 109 virtual patients and use a novel approach to calibrate two trigger thresholds: residence time and shear rate, thus addressing the second question. We then address the third question by utilizing this calibrated model to provide new insight into the effects of hypertension on spontaneous thrombosis. We demonstrate how a mechanistic thrombosis model calibrated on an intracranial aneurysm cohort can help estimate spontaneous thrombosis prevalence in a broader aneurysm population. This study is enabled through a fully automatic multi-scale modeling pipeline. We use the clinical spontaneous thrombosis data as an indirect population-level validation of a complex computational modeling framework. Furthermore, our framework allows exploration of the influence of hypertension in spontaneous thrombosis. This lays the foundation for in silico clinical trials of cerebrovascular devices in high-risk populations, e.g., assessing the performance of flow diverters in aneurysms for hypertensive patients.
- 7 July 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (3) , 036102
Open AccessHemodynamics of thrombus formation in intracranial aneurysms: An in silico observational study
How prevalent is spontaneous thrombosis in a population containing all sizes of intracranial aneurysms? How can we calibrate computational models of thrombosis based on published data? How does spontaneous thrombosis differ in normo- and hypertensive subjects? We address the first question through a thorough analysis of published datasets that provide spontaneous thrombosis rates across different aneurysm characteristics. This analysis provides data for a subgroup of the general population of aneurysms, namely, those of large and giant size (>10 mm). Based on these observed spontaneous thrombosis rates, our computational modeling platform enables the first in silico observational study of spontaneous thrombosis prevalence across a broader set of aneurysm phenotypes. We generate 109 virtual patients and use a novel approach to calibrate two trigger thresholds: residence time and shear rate, thus addressing the second question. We then address the third question by utilizing this calibrated model to provide new insight into the effects of hypertension on spontaneous thrombosis. We demonstrate how a mechanistic thrombosis model calibrated on an intracranial aneurysm cohort can help estimate spontaneous thrombosis prevalence in a broader aneurysm population. This study is enabled through a fully automatic multi-scale modeling pipeline. We use the clinical spontaneous thrombosis data as an indirect population-level validation of a complex computational modeling framework. Furthermore, our framework allows exploration of the influence of hypertension in spontaneous thrombosis. This lays the foundation for in silico clinical trials of cerebrovascular devices in high-risk populations, e.g., assessing the performance of flow diverters in aneurysms for hypertensive patients.
- Open Access
- 23 June 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-12
In-silico trial of intracranial flow diverters replicates and expands insights from conventional clinical trials
The cost of clinical trials is ever-increasing. In-silico trials rely on virtual populations and interventions simulated using patient-specific models and may offer a solution to lower these costs. We present the flow diverter performance assessment (FD-PASS) in-silico trial, which models the treatment of intracranial aneurysms in 164 virtual patients with 82 distinct anatomies with a flow-diverting stent, using computational fluid dynamics to quantify post-treatment flow reduction. The predicted FD-PASS flow-diversion success rates replicate the values previously reported in three clinical trials. The in-silico approach allows broader investigation of factors associated with insufficient flow reduction than feasible in a conventional trial. Our findings demonstrate that in-silico trials of endovascular medical devices can: (i) replicate findings of conventional clinical trials, and (ii) perform virtual experiments and sub-group analyses that are difficult or impossible in conventional trials to discover new insights on treatment failure, e.g. in the presence of side-branches or hypertension.
- 23 June 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-12
Open AccessIn-silico trial of intracranial flow diverters replicates and expands insights from conventional clinical trials
The cost of clinical trials is ever-increasing. In-silico trials rely on virtual populations and interventions simulated using patient-specific models and may offer a solution to lower these costs. We present the flow diverter performance assessment (FD-PASS) in-silico trial, which models the treatment of intracranial aneurysms in 164 virtual patients with 82 distinct anatomies with a flow-diverting stent, using computational fluid dynamics to quantify post-treatment flow reduction. The predicted FD-PASS flow-diversion success rates replicate the values previously reported in three clinical trials. The in-silico approach allows broader investigation of factors associated with insufficient flow reduction than feasible in a conventional trial. Our findings demonstrate that in-silico trials of endovascular medical devices can: (i) replicate findings of conventional clinical trials, and (ii) perform virtual experiments and sub-group analyses that are difficult or impossible in conventional trials to discover new insights on treatment failure, e.g. in the presence of side-branches or hypertension.
- 5 November 2019
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (1) , e3271
Population‐specific modelling of between/within‐subject flow variability in the carotid arteries of the elderly
Computational fluid dynamics models are increasingly proposed for assisting the diagnosis and management of vascular diseases. Ideally, patient‐specific flow measurements are used to impose flow boundary conditions. When patient‐specific flow measurements are unavailable, mean values of flow measurements across small cohorts are used as normative values. In reality, both the between‐subjects and within‐subject flow variabilities are large. Consequently, neither one‐shot flow measurements nor mean values across a cohort are truly indicative of the flow regime in a given person. We develop models for both the between‐subjects and within‐subject variability of internal carotid flow. A log‐linear mixed effects model is combined with a Gaussian process to model the between‐subjects flow variability, while a lumped parameter model of cerebral autoregulation is used to model the within‐subject flow variability in response to heart rate and blood pressure changes. The model parameters are identified from carotid ultrasound measurements in a cohort of 103 elderly volunteers. We use the models to study intracranial aneurysm flow in 54 subjects under rest and exercise and conclude that OSI, a common wall shear‐stress derived quantity in vascular CFD studies, may be too sensitive to flow fluctuations to be a reliable biomarker.
- 5 November 2019
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (1) , e3271
Population‐specific modelling of between/within‐subject flow variability in the carotid arteries of the elderly
Computational fluid dynamics models are increasingly proposed for assisting the diagnosis and management of vascular diseases. Ideally, patient‐specific flow measurements are used to impose flow boundary conditions. When patient‐specific flow measurements are unavailable, mean values of flow measurements across small cohorts are used as normative values. In reality, both the between‐subjects and within‐subject flow variabilities are large. Consequently, neither one‐shot flow measurements nor mean values across a cohort are truly indicative of the flow regime in a given person. We develop models for both the between‐subjects and within‐subject variability of internal carotid flow. A log‐linear mixed effects model is combined with a Gaussian process to model the between‐subjects flow variability, while a lumped parameter model of cerebral autoregulation is used to model the within‐subject flow variability in response to heart rate and blood pressure changes. The model parameters are identified from carotid ultrasound measurements in a cohort of 103 elderly volunteers. We use the models to study intracranial aneurysm flow in 54 subjects under rest and exercise and conclude that OSI, a common wall shear‐stress derived quantity in vascular CFD studies, may be too sensitive to flow fluctuations to be a reliable biomarker.
- Open Access
- 15 December 2017
- Published by The Royal Society in Interface Focus
- Vol. 8 (1) , 20170019
Subject-specific multi-poroelastic model for exploring the risk factors associated with the early stages of Alzheimer's disease
There is emerging evidence suggesting that Alzheimer's disease is a vascular disorder, caused by impaired cerebral perfusion, which may be promoted by cardiovascular risk factors that are strongly influenced by lifestyle. In order to develop an understanding of the exact nature of such a hypothesis, a biomechanical understanding of the influence of lifestyle factors is pursued. An extended poroelastic model of perfused parenchymal tissue coupled with separate workflows concerning subject-specific meshes, permeability tensor maps and cerebral blood flow variability is used. The subject-specific datasets used in the modelling of this paper were collected as part of prospective data collection. Two cases were simulated involving male, non-smokers (control and mild cognitive impairment (MCI) case) during two states of activity (high and low). Results showed a marginally reduced clearance of cerebrospinal fluid (CSF)/interstitial fluid (ISF), elevated parenchymal tissue displacement and CSF/ISF accumulation and drainage in the MCI case. The peak perfusion remained at 8 mm s −1 between the two cases.
- 15 December 2017
- Published by The Royal Society in Interface Focus
- Vol. 8 (1) , 20170019
Open AccessSubject-specific multi-poroelastic model for exploring the risk factors associated with the early stages of Alzheimer's disease
There is emerging evidence suggesting that Alzheimer's disease is a vascular disorder, caused by impaired cerebral perfusion, which may be promoted by cardiovascular risk factors that are strongly influenced by lifestyle. In order to develop an understanding of the exact nature of such a hypothesis, a biomechanical understanding of the influence of lifestyle factors is pursued. An extended poroelastic model of perfused parenchymal tissue coupled with separate workflows concerning subject-specific meshes, permeability tensor maps and cerebral blood flow variability is used. The subject-specific datasets used in the modelling of this paper were collected as part of prospective data collection. Two cases were simulated involving male, non-smokers (control and mild cognitive impairment (MCI) case) during two states of activity (high and low). Results showed a marginally reduced clearance of cerebrospinal fluid (CSF)/interstitial fluid (ISF), elevated parenchymal tissue displacement and CSF/ISF accumulation and drainage in the MCI case. The peak perfusion remained at 8 mm s −1 between the two cases.
- Open Access
- 1 December 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (16) , 3815-3823
Uncertainty quantification of wall shear stress in intracranial aneurysms using a data-driven statistical model of systemic blood flow variability
- 1 December 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (16) , 3815-3823
Open AccessUncertainty quantification of wall shear stress in intracranial aneurysms using a data-driven statistical model of systemic blood flow variability
- 2 October 2016
- Published by Springer Nature
- p. 201-209
Direct Estimation of Wall Shear Stress from Aneurysmal Morphology: A Statistical Approach
- 2 October 2016
- Published by Springer Nature
- p. 201-209
Direct Estimation of Wall Shear Stress from Aneurysmal Morphology: A Statistical Approach
- Open Access
- 2 January 2016
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 13 (1) , e18217
Effects of Variations of Flow and Heart Rate on Intra-Aneurysmal Hemodynamics in a Ruptured Internal Carotid Artery Aneurysm During Exercise
Background: Hemodynamics is thought to play an important role in the mechanisms responsible for initiation, growth, and rupture of intracranial aneurysms. Computational fluid dynamic (CFD) analysis is used to assess intra-aneurysmal hemodynamics. Objectives: This study aimed to investigate the effects of variations in heart rate and internal carotid artery (ICA) flow rate on intra-aneurysmal hemodynamics, in an ICA aneurysm, by using computational fluid dynamics. Patients and Methods: Computed tomography angiography (CTA) was performed in a 55 years old female case, with a saccular ICA aneurysm, to create a patient-specific geometrical anatomic model of the aneurysm. The intra-aneurysmal hemodynamic environments for three states with different flow and heart rates were analyzed using patient-specific image-based CFD modeling. Results: Results showed significant changes for the three simulated states. For a proportion of the states examined, results were counterintuitive. Systolic and time-averaged wall shear stress and pressure on the aneurysm wall showed a proportional evolution with the mainstream flow rate. Conclusion: Results reinforced the pivotal role of vascular geometry, with respect to hemodynamics, together with the importance of performing patient-specific CFD analyses, through which the effect of different blood flow conditions on the aneurysm hemodynamics could be evaluated. Keywords: Fluid Dynamics; Internal Carotid Artery; Aneurysm; Heart Rate
- 2 January 2016
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 13 (1) , e18217
Open AccessEffects of Variations of Flow and Heart Rate on Intra-Aneurysmal Hemodynamics in a Ruptured Internal Carotid Artery Aneurysm During Exercise
Background: Hemodynamics is thought to play an important role in the mechanisms responsible for initiation, growth, and rupture of intracranial aneurysms. Computational fluid dynamic (CFD) analysis is used to assess intra-aneurysmal hemodynamics. Objectives: This study aimed to investigate the effects of variations in heart rate and internal carotid artery (ICA) flow rate on intra-aneurysmal hemodynamics, in an ICA aneurysm, by using computational fluid dynamics. Patients and Methods: Computed tomography angiography (CTA) was performed in a 55 years old female case, with a saccular ICA aneurysm, to create a patient-specific geometrical anatomic model of the aneurysm. The intra-aneurysmal hemodynamic environments for three states with different flow and heart rates were analyzed using patient-specific image-based CFD modeling. Results: Results showed significant changes for the three simulated states. For a proportion of the states examined, results were counterintuitive. Systolic and time-averaged wall shear stress and pressure on the aneurysm wall showed a proportional evolution with the mainstream flow rate. Conclusion: Results reinforced the pivotal role of vascular geometry, with respect to hemodynamics, together with the importance of performing patient-specific CFD analyses, through which the effect of different blood flow conditions on the aneurysm hemodynamics could be evaluated. Keywords: Fluid Dynamics; Internal Carotid Artery; Aneurysm; Heart Rate
- Open Access
- 17 October 2015
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 12 (4) , e18286
Velocity Measurement in Carotid Artery: Quantitative Comparison of Time-Resolved 3D Phase-Contrast MRI and Image-based Computational Fluid Dynamics
Background: Understanding hemodynamic environment in vessels is important for realizing the mechanisms leading to vascular pathologies. Objectives: Three-dimensional velocity vector field in carotid bifurcation is visualized using TR 3D phase-contrast magnetic resonance imaging (TR 3D PC MRI) and computational fluid dynamics (CFD). This study aimed to present a qualitative and quantitative comparison of the velocity vector field obtained by each technique. Subjects and Methods: MR imaging was performed on a 30-year old male normal subject. TR 3D PC MRI was performed on a 3 T scanner to measure velocity in carotid bifurcation. 3D anatomical model for CFD was created using images obtained from time-of-flight MR angiography. Velocity vector field in carotid bifurcation was predicted using CFD and PC MRI techniques. A statistical analysis was performed to assess the agreement between the two methods. Results: Although the main flow patterns were the same for the both techniques, CFD showed a greater resolution in mapping the secondary and circulating flows. Overall root mean square (RMS) errors for all the corresponding data points in PC MRI and CFD were 14.27% in peak systole and 12.91% in end diastole relative to maximum velocity measured at each cardiac phase. Bland-Altman plots showed a very good agreement between the two techniques. However, this study was not aimed to validate any of methods, instead, the consistency was assessed to accentuate the similarities and differences between Time-resolved PC MRI and CFD. Conclusion: Both techniques provided quantitatively consistent results of in vivo velocity vector fields in right internal carotid artery (RCA). PC MRI represented a good estimation of main flow patterns inside the vasculature, which seems to be acceptable for clinical use. However, limitations of each technique should be considered while interpreting results. Keywords: Fluid Dynamics; Time-Resolved Three-Dimensional Phase-Contrast Magnetic Resonance Imaging (TR 3D PC MRI); Carotid Bifurcation
- 17 October 2015
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 12 (4) , e18286
Open AccessVelocity Measurement in Carotid Artery: Quantitative Comparison of Time-Resolved 3D Phase-Contrast MRI and Image-based Computational Fluid Dynamics
Background: Understanding hemodynamic environment in vessels is important for realizing the mechanisms leading to vascular pathologies. Objectives: Three-dimensional velocity vector field in carotid bifurcation is visualized using TR 3D phase-contrast magnetic resonance imaging (TR 3D PC MRI) and computational fluid dynamics (CFD). This study aimed to present a qualitative and quantitative comparison of the velocity vector field obtained by each technique. Subjects and Methods: MR imaging was performed on a 30-year old male normal subject. TR 3D PC MRI was performed on a 3 T scanner to measure velocity in carotid bifurcation. 3D anatomical model for CFD was created using images obtained from time-of-flight MR angiography. Velocity vector field in carotid bifurcation was predicted using CFD and PC MRI techniques. A statistical analysis was performed to assess the agreement between the two methods. Results: Although the main flow patterns were the same for the both techniques, CFD showed a greater resolution in mapping the secondary and circulating flows. Overall root mean square (RMS) errors for all the corresponding data points in PC MRI and CFD were 14.27% in peak systole and 12.91% in end diastole relative to maximum velocity measured at each cardiac phase. Bland-Altman plots showed a very good agreement between the two techniques. However, this study was not aimed to validate any of methods, instead, the consistency was assessed to accentuate the similarities and differences between Time-resolved PC MRI and CFD. Conclusion: Both techniques provided quantitatively consistent results of in vivo velocity vector fields in right internal carotid artery (RCA). PC MRI represented a good estimation of main flow patterns inside the vasculature, which seems to be acceptable for clinical use. However, limitations of each technique should be considered while interpreting results. Keywords: Fluid Dynamics; Time-Resolved Three-Dimensional Phase-Contrast Magnetic Resonance Imaging (TR 3D PC MRI); Carotid Bifurcation
- 13 August 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (1) , 207-221
Modeling of the Acute Effects of Primary Hypertension and Hypotension on the Hemodynamics of Intracranial Aneurysms
Hemodynamics is a risk factor in intracranial aneurysms (IA). Hypertension and pharmacologically induced hypotension are common in IA patients. This study investigates how hypertension and hypotension may influence aneurysmal hemodynamics. Images of 23 IAs at typical locations were used to build patient-specific Computational Fluid Dynamics models. The effects of hypotension and hypertension were simulated through boundary conditions by modulating the normotensive flow and pressure waveforms, in turn produced by a 1D systemic vascular model. Aneurysm location and flow pattern types were used to categorize the influence of hypotension and hypertension on relevant flow variables (velocity, pressure and wall shear stress). Results indicate that, compared to other locations, vertebrobasilar aneurysms (VBA) are more sensitive to flow changes. In VBAs, space-averaged velocity at peak systole increased by 30% in hypertension (16–21% in other locations). Flow in VBAs in hypotension decreased by 20% (10–13% in other locations). Momentum-driven hemodynamic types were also more affected by hypotension and hypertension, than shear-driven types. This study shows how patient-specific modeling can be effectively used to identify location-specific flow patterns in a clinically-relevant study, thus reinforcing the role played by modeling technologies in furthering our understanding of cardiovascular disease, and their potential in future healthcare.
- 13 August 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (1) , 207-221
Modeling of the Acute Effects of Primary Hypertension and Hypotension on the Hemodynamics of Intracranial Aneurysms
Hemodynamics is a risk factor in intracranial aneurysms (IA). Hypertension and pharmacologically induced hypotension are common in IA patients. This study investigates how hypertension and hypotension may influence aneurysmal hemodynamics. Images of 23 IAs at typical locations were used to build patient-specific Computational Fluid Dynamics models. The effects of hypotension and hypertension were simulated through boundary conditions by modulating the normotensive flow and pressure waveforms, in turn produced by a 1D systemic vascular model. Aneurysm location and flow pattern types were used to categorize the influence of hypotension and hypertension on relevant flow variables (velocity, pressure and wall shear stress). Results indicate that, compared to other locations, vertebrobasilar aneurysms (VBA) are more sensitive to flow changes. In VBAs, space-averaged velocity at peak systole increased by 30% in hypertension (16–21% in other locations). Flow in VBAs in hypotension decreased by 20% (10–13% in other locations). Momentum-driven hemodynamic types were also more affected by hypotension and hypertension, than shear-driven types. This study shows how patient-specific modeling can be effectively used to identify location-specific flow patterns in a clinically-relevant study, thus reinforcing the role played by modeling technologies in furthering our understanding of cardiovascular disease, and their potential in future healthcare.